• Title/Summary/Keyword: Radiography, Panoramic

Search Result 298, Processing Time 0.024 seconds

Spontaneous bone regeneration in resected non-continuous mandible due to medication-related osteonecrosis of the jaw

  • Esen, Alparslan;Gurses, Gokhan;Akkulah, Sebne
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.6
    • /
    • pp.465-470
    • /
    • 2021
  • Few cases of spontaneous bone regeneration after extensive resection of the jaw bone have been reported, but it is more common in young adults or children. In this case, we report spontaneous bone healing in a 73-year-old female patient. On radiological examination, necrotic regions were seen in the right mandible. She was diagnosed with medication-related osteonecrosis of the jaw due to previous bisphosphonate use. After segmental resection, stabilization achieved using a reconstruction plate. The periosteum was preserved during the procedure. Twelve months later, panoramic radiography was taken and bone formation was seen both horizontally and vertically around the plate. If the periosteum is preserved and stabilization is achieved after resection in benign lesions, the bone may regenerate spontaneously regardless of age. Therefore, instead of simultaneous autogenous bone application, such patients may be followed to determine whether spontaneous bone healing will occur. This should improve patient comfort and reduce surgical cost.

Dental radiology reporting status and recording frequency of reporting items in Korea

  • Jinwoo Choi
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.35-42
    • /
    • 2023
  • Purpose: This study investigated the current dental radiology reporting methods and the recording rate of 10 mandatory reporting items in Korea. Materials and Methods: An original online survey created using Google Forms was distributed to dental practitioners. The survey asked about the participants' age, experience, workplace, use of radiologic equipment, radiology reporting methods, and recording reporting items. Results: In total, 354 responses were analyzed. Radiologic reporting in dental charts was the most commonly used method for each modality. Four out of 10 mandatory items were recorded at a high rate, but the remaining 6 items had substantially lower recording rates, often below 50%. The participants who reported radiographic findings through other separate methods had higher item scores than those who wrote findings in dental charts(P<0.05). Conclusion: Radiologic societies and dental associations should encourage the use of separate reports for radiographic examinations. Education regarding radiology reports and the justification for reporting items should be reinforced in dental schools, training courses on radiology, and the continuing education curriculum.

Simple bone cyst recurred in adjacent areas: A case report

  • Jin-Soo Kim
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.383-388
    • /
    • 2023
  • Simple bone cyst is a pseudocyst that typically occurs in patients during their second and third decades of life. This benign entity is an empty or fluid-filled cavity that lacks a true epithelial lining. Simple bone cysts are often asymptomatic and are commonly found in mandibular body, predominantly in the posterior region. The treatment of simple bone cysts can be influenced by factors such as the patient's age, the size of the lesion, and the presence or absence of symptoms. In the case of a simple bone cyst in the mandible that is small and symptomless, a watchful waiting approach may be appropriate. However, if the cyst is large and symptomatic, surgical treatment is recommended. This report presents a radiological examination of a simple bone cyst that developed around the root of the mandibular first molar in a 36-year-old female patient. The cyst recurred in adjacent areas despite surgical treatment.

Pediatric mandibular chronic nonbacterial osteomyelitis: A case report with 12 years of radiologic follow-up

  • Sehyun Choi;Min-Ji Kim;Sang-Hoon Kang;In-Woo Park
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.93-104
    • /
    • 2024
  • Chronic nonbacterial osteomyelitis(CNO) is histologically characterized by nonspecific osteitis. This inflammatory disorder, which lacks an infectious origin, typically presents with chronic pain and swelling at the affected site that can persist for months or even years. However, it is rare for CNO to affect the mandible. A 10-year-old girl presented with a primary complaint of pain in her left mandible. She had no significant medical or dental history. On examination, swelling was visible on the left buccal side, and imaging revealed radiolucent bone deterioration within the left mandible. This case report presents the radiological changes observed over a 12-year follow-up period. Variations in radiopacity, radiolucency, and periosteal reactions were noted periodically. This case highlights the radiological characteristics and findings that are crucial for the diagnosis of CNO, a condition for which no clear diagnostic criteria are currently available.

Correlation of bone quality in radiographic images with clinical bone quality classification (방사선사진에서의 골질과 임상적으로 평가한 골질 분류의 상관관계)

  • Kim Hyun-Woo;Huh Kyung-Hoe;Park Kwan-Soo;Kim Jeong-Hwa;Yi Won-Jin;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.25-32
    • /
    • 2006
  • Purpose : To investigate the validity of digital image processing on panoramic radiographs in estimating bone quality before endosseous dental implant installation by correlating bone quality in radiographic images with clinical bone quality classification. Materials and Methods : An experienced surgeon assessed and classified bone quality for implant sites with tactile sensation at the time of implant placement. Including fractal dimension eighteen morphologic features of trabecular pattern were examined In each anatomical sites on panoramic radiographs. Finally bone quality of 67 implant sites were evaluated in 42 patients. Results : Pearson correlation analysis showed that three morphologic parameters had weak linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.276, -0.280, and - 0.289, respectively (p<0.05). And other three morphologic parameters had obvious linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.346, -0.488, and -0.343 respectively (p<0.05). Fractal dimension also had a linear correlation with clinical bone quality classification with correlation coefficients -0.506 significantly (p<0.05). Conclusion : This study suggests that fractal and morphometric analysis using digital panoramic radiographs can be used to evaluate bone quality for implant recipient sites.

  • PDF

Benign Tumor-Like Developmental Salivary Gland Defect (양성 종양과 유사한 형태를 가진 발육성 타액선 골결손)

  • An, Seo-Young;Kim, Yong-Gun;Jung, Jae-Kwang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.301-307
    • /
    • 2012
  • 50-year-old female and 50-year-old male were referred to the department of the oral and maxillofacial surgery of Kyungpook national university dental hospital with asymptomatic lesions on their posterior mandibular body areas. They were discovered incidentally on panoramic radiographs during routine dental examination. Physical examination revealed no remarkable findings. Each panoramic radiograph showed well defined radiolucent lesions without hyperostotic border on their posterior mandibular body area. At first they were diagnosed as benign tumors because they looked like multilocular pattern and one of the patient showed discontinuity of mandibular canal within the lesion. CT scans demonstrated well demarcated and irregular lingual depression filled with fat tissue and they were diagnosed as developmental salivary gland defects. One of the lesion showed no change on follow-up panoramic radiograph after 4 months. Developmental salivary gland defects resembling benign tumor are atypical cases and it is suggested that confirmatory imaging using CT or MRI should be taken.

Comparison of autogenous tooth bone graft and synthetic bone graft materials used for bone resorption around implants after crestal approach sinus lifting: a retrospective study

  • Kim, Young-Kyun;Lee, Junho;Yun, Ji-Young;Yun, Pil-Young;Um, In-Woong
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.216-221
    • /
    • 2014
  • Purpose: This retrospective study compares the amount of bone resorption around implants between an autogenous tooth bone graft (AutoBT) and a synthetic bone graft after a bone-added crestally approached sinus lift with simultaneous implant placements. Methods: In all, 37 patients participated in this study. Seventeen patients were grouped as group I and underwent an AutoBT-added sinus lift using the crestal approach. The remaining 20 patients were grouped as group II and underwent synthetic bone grafting. Both groups received the implant placements simultaneously. Of the 37 participating patients, only 22 patients were included in the final results: Eleven patients of group I and 11 patients of group II. Before the surgery, the distance from the alveolar crest to the sinus floor was measured using panoramic radiography. After the surgery, the distance was measured again from the neck of the implant thread to the most superior border of the added graft materials. Then, the amount of sinus lift was calculated by comparing the two panoramic radiographs. After a year, a panoramic radiograph was taken to calculate the resorption of the bone graft material from the radiograph that was taken after the surgery. The significance of the resorption amount between the two types of graft materials was statistically analyzed. Results: The bone height was increased to an average of 4.89 mm in group I and 6.22 mm in group II. The analysis of panoramic radiographs 1 year after the surgery showed an average bone resorption of 0.76 mm and 0.53 mm, respectively. However, the degree of lifting (P=0.460) and the amount of bone-grafted material resorption (P=0.570) showed no statistically significant difference. Conclusions: Based on this limited study, AutoBT can be considered a good alternative bone graft to a synthetic bone graft in a bone-added sinus lift, when extraction is necessary prior to the surgery.

Diagnostic imaging analysis of the impacted mesiodens (매복 정중치의 진단영상분석)

  • Noh, Jeong-Jun;Choi, Bo-Ram;Jeong, Hwan-Seok;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.2
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose : The research was performed to predict the three dimensional relationship between the impacted mesiodens and the maxillary central incisors and the proximity with the anatomic structures by comparing their panoramic images with the CT images. Materials and Methods : Among the patients visiting Seoul National University Dental Hospital from April 2003 to July 2007, those with mesiodens were selected (154 mesiodens of 120 patients). The numbers, shapes, orientation and positional relationship of mesiodens with maxillary central incisors were investigated in the panoramic images. The proximity with the anatomical structures and complications were investigated in the CT images as well. Results : The sex ratio (M : F) was 2.28 : 1 and the mean number of mesiodens per one patient was 1.28. Conical shape was 84.4% and inverted orientation was 51.9%. There were more cases of anatomical structures encroachment, especially on the nasal floor and nasopalatine duct, when the mesiodens was not superimposed with the central incisor. There were, however, many cases of the nasopalatine duct encroachment when the mesiodens was superimpoised with the apical 1/3 of central incisor (52.6%). Delayed eruption (55.6%), crown rotation (66.7%) and crown resorption (100%) were observed when the mesiodens was superimposed with the crown of the central incisor. Conclusion : It is possible to predict three dimensional relationship between the impacted mesiodens and the maxillary central incisors in the panoramic images, but more details should be confirmed by the CT images when necessary.

Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality

  • Choi, Da-Hye;Choi, Bo-Ram;Choi, Jin-Woo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.43 no.1
    • /
    • pp.7-15
    • /
    • 2013
  • Purpose: This study was performed to suggest reference line-pair values of panoramic images with clinically desirable qualities using an arch-form phantom stand. Materials and Methods: The line-pair test phantom was chosen. A real skull model was selected for setting the arch-form model of the phantom stand. The phantom stand had slits in four regions (incisor, premolar, molar, TMJ). Four raw images of the test phantom in each region and one raw image of the real skull were converted into 50 test phantom images and 50 skull phantom images with various line-pair values. 50 post-processed real skull phantom images were divided into 4 groups and were randomly submitted to 14 evaluators. Image quality was graded on a 4 point scale (1. good, 2. normal, 3. poor but interpretable, and 4. not interpretable). The reference line pair was determined as the first line-pair value scored less than 2 points. Result: The mean scores tended to decrease as the line-pair values increased. The reference line-pair values were 3.19 LP/mm in the incisor, 2.32 LP/mm in the premolar and TMJ, and 1.88 LP/mm in the molar region. Conclusion: Image quality evaluation methods and criteria should be able to assess various regions considering the characteristics of panoramic systems. This study suggested overall and regional reference line-pair values and established a set of standard values for them.

The Effects of a Thyroid Shield Made of a Tissue-Equivalent Material on the Reduction of the Thyroid Exposure Dose in Panoramic Radiography (파노라마촬영 시 조직등가물질을 이용한 갑상선보호대의 갑상선피폭선량 감소효과)

  • Lee, Hye-Lim;Kim, Hyun-Yung;Choi, Hyung-Wook;Lee, Hye-Mi;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2278-2284
    • /
    • 2012
  • Exposure-dose reducing effect was measured by using bolus, a tissue-equivalent material as a shield to obtain useful diagnostic images while minimizing the radiation exposure of thyroid which is highly sensitive to radiation during panoramic radiography. The experiment was performed within the period of 1 June 2001 through 30 June 2011 by measuring entrance surface dose and deep dose at the thyroid-corresponding site of a head and neck phantom. As a result, the entrance surface dose in the thyroid for using no shield was 43.84 ${\mu}Gy$ on the average, and the thyroid shield of bolus 10 mm in thickness reduced the dose by 15.45 ${\mu}Gy$(35.24%) to 28.39 ${\mu}Gy$ on the average. The use of a 20 mm thyroid shield resulted in the dose of 25.38 ${\mu}Gy$ on the average, a 18.46 ${\mu}Gy$(42.10%) drop from 43.84 ${\mu}Gy$ for using no shield. On the site 20 mm below the surface, a thyroid shield 10 mm in thickness had no dose-reducing effect, while a 20 mm thyroid shield reduced the dose by 0.06 mSv(20%).