• 제목/요약/키워드: Radiographic results

검색결과 1,354건 처리시간 0.023초

보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究) (Survery on Business of the Departments of Radiology in Health Centers)

  • 최종학;전만진;허준;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

방사선 치료 후 폐암환자의 운동부하 심.폐 기능의 초기변화 (Early Response of Cardiopulmonary Exercise Test(CPET) in Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Radiation)

  • 신경철;이덕희;이관호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제49권4호
    • /
    • pp.466-473
    • /
    • 2000
  • 연구배경 : 수술로 절제하기 어려운 국소진행성 제3기 비소세포 암은 주로 방사선 치료 단독 혹은 방사선 치료와 전신 항암화학요법을 병행하게 된다. 이 두 치료 방법은 잠재적으로 폐 기능을 손상시킬 수 있으며 기존의 폐 기능을 더욱 악화시키게 된다. 저자들은 국소진행성 폐암환자들에 대하여 방사선 치료 전 후 안정시 폐 기능과 운동시 심 폐 기능을 동시에 평가하여 방사선 치료가 실제 운동부하 심 폐 기능에 미치는 영향을 평가하였다. 대상 및 방법 : 수술로 절제할 수 없는 편평상피세포암을 가진 남자 11명에 대하여 방사선 치료 전과 치료 후 4주에 각각 흉부 X-선 검사 및 안정시 폐 기능 검사 그리고 운동부하 심 폐 기능 검사를 시행하였다. 운동부하 심 폐 기능 검사로 운동능력과 심 혈관계기능, 환기기능, 그리고 가스교환기능에 대하여 측정하였다. 방사선 치료는 일일 1.8Gy로 일 주일에 5회 시행하여, 8주 동안 70Gy를 시행하였다. 결과 : 저자들의 연구로 방사선 치료 전 후 다음과 같은 결과를 얻었다. 1) 최대산소섭취량($VO_2$max), 이산화탄소생성량($VCO_2$), 운동지속시간 그리고 운동수행능력의 차이는 없었다. 2) 산소맥($O_2$ pulse) 및 심박동수, 그리고 예비심박동수(heart rate reserve)의 변화도 없었다. 3) 최대분당환기량(VEmax) 및 상시호흡량 그리고 예비호흡의 변화도 없었다. 4) 운동부하 심 폐 기능 검사 중 대부분의 환자는 호흡곤란과 다리근육의 피로로 더 이상 운동을 할 수 없었다. 5) 안정시 폐 기능 검사 결과 노력성 폐활량(FVC) 과 1초간 노력성 호기량($FEV_1$)의 변화는 없었으나 폐확산능(DLCO)은 치료 전 후 각각 85%, 74%로 약 11%의 감소가 있었지만 통계적으로 유의 하지는 않았다. 결론 : 방사선 치료 후 4주에 평가한 국소진행성 폐암환자의 운동부하 심 폐 기능 검사 결과 치료 전에 비하여 운동능력 및 심 혈관계기능, 환기기능, 그리고 폐포의 가스교환기능의 차이는 없었다. 결론적으로 폐암환자는 방사선 치료 후 운동부하 심 폐 기능의 저하는 단기간 내 일어나지 않는 것으로 생각된다.

  • PDF

기관지 폐포암의 임상적 특성 (Clinical Study of Bronchioloalveolar Cell Carcinoma)

  • 최진원;박익수;김진호;윤호주;신동호;김태화;박성수;이정희
    • Tuberculosis and Respiratory Diseases
    • /
    • 제41권1호
    • /
    • pp.26-35
    • /
    • 1994
  • 연구배경 : 기관지 폐포암의 발생빈도가 타 원발성 폐암의 발생속도보다 빠르게 증가하고 있는 추세이고 조기진단 및 이에 따른 적절한 수술적 치료가 이루어진 경우 뛰어난 예후를 기대할 수 있다. 그러나 국내에 기관지 폐포암에 대한 보고가 적고 무엇보다도 이 암의 임상양상이나 방사선학적 소견이 우리 주변의 흔한 다른 폐질환과 유사한 양상을 나타내 감별진단이 어려우므로 적절한 수술시기를 놓칠 수 있어 이에 저자들은 기관지 폐포암 환자의 임상적 양상, 방사선학적 소견, 치료 및 그에 따른 예후등을 분석해 보고자 하였다. 방법 : 5년간 발생한 기관지 폐포암 환자 24예를 대상으로 환자의 성별, 연령분포, 주 증세 발현시기, 흡연력, 선행 폐질환의 유무 등을 조사하였고 내원당시 환자의 자각증상 및 이학적 소견을 분석하고 치료를 받은 환자에 있어 예후를 조사하였으며 각각의 방사선학적 소견에 따른 예후를 후향적으로 분석해 보았다. 결과: 1) 5년간 진단받은 기관지 24예는 폐포함 24예는 동 기간 발생한 원발성 폐암의 1.3%였다. 2) 대상 환자의 남녀비는 1:1.4이였고 50대가 13예(54.1%)로 빈도가 가장 높았다. 대상 환자중 1~3개월전 주 증세가 발현한 경우가 8예(33.3%)로 가장 많았고 주 증세로 기침이 15예(65%), 객담 및 흉통이 각각 7예(29.2%)이였다. 3) 방사선학적소견상 고립성 결절형이 13예(54.2%)로 가장 많은 빈도를 보였고 다발성 결절형 6예(25%), 침윤성 4예(16.7%), 공동을 동반한 결절형 1예(4%)의 순이였다. 4) 기관지 폐포암의 진단은 미세침 폐생검을 통해 14예(58.3%), 객담 세포검사를 통해 11예(45.8%)에서 확진을 얻었으며 경기관지 폐생검으로 7예(29.2%), 개흉 폐생검으로 2예에서 확진을 얻었다. 5) 진단시 환자들의 병기는 stage IIIb 이상이 14예(58.3%)로 수술적 치료를 할 수 없는 경우가 대부분이었다. 6) 대상 환자중 stage IIIa이하인 7예와 stage IV 1예, 총 8예에서 폐절제술, 폐엽절제술, 설절제술등의 수술적 치료를 시행하였다. 이 중 타 질환으로 사망한 1예를 제외하고 4예에서 최고 61개월간 재발의 증거 없이 생존하고 있으며 4예 모두 고립성 결절형이거나 국소적인 병변을 가진 stage I, II의 환자들이였다. 방사선학적 소견에 따른 예후를 비교해 보았을 때 고립성 결절형인 경우 6개월, 12개월 누적 생존율이 각각 66.6%, 58.3%로 66.6%, 1.67%의 다발성 결정형인 경우 보다 뛰어난 예후를 보임을 알 수 있었다. 결론 : 이상의 결과로 미루어 보아 기관지 폐포암의 치료를 위해서는 임상의사의 적극적인 노력과 환자의 협조로 기관지 폐포암을 조기발견하여 가능한한 초기에 수술을 시행하여야 한다고 사료되며 특히 병변이 고립성 결절형이거나 국소적일 경우 폐절제술 및 폐엽절제술 등의 수술적 치료를 시행하여야 좋은 예후를 기대할 수 있으리라 사료된다.

  • PDF

가을철 유행하는 급성열성질환의 폐침범과 CRP와의 연관관계 (A Correlation between Pulmonary Involvement of Acute Febrile Illness with High Incidence during the Fall and C-reactive Protein)

  • 김고운;이우진;홍원기;이성화;이창률;이명구;현인규;정기석
    • Tuberculosis and Respiratory Diseases
    • /
    • 제66권2호
    • /
    • pp.116-121
    • /
    • 2009
  • 연구배경: 쯔쯔가무시병, 렙토스피라병, 신증후출혈열은 우리나라에서 흔한 급성열성질환으로 최근 발병과 유행성의 보고가 있음에도 불구하고 열성질환에 있어서 폐침범에 대한 연구는 부족한 상태이다. 열성질환에 있어서 폐합병증이 있을 때 임상적으로 더 심한 경과를 보이고 CRP 수치도 더 높게 측정되는 경우가 있어 입원 시 측정한 CRP값이 조기에 적극적인 치료 대상에 대한 예측인자가 될 수 있는지 알아보고자 하였다. 방 법: 2002년 1월부터 2008년 5월까지 한림대학교 춘천성심병원에서 혈청학적 검사에서 양성이거나 임상적으로 진단을 받았던 환자를 대상으로 후향적 연구를 하였다. 결 과: 총 105명의 환자가 대상이 되었고 쯔쯔가무시병 63명(63%), 신증후출혈열 32명(30.5%), 렙토스피라병 10명(9.5%)이었고 폐침범은 42명(40%)에서 관찰되었으며 폐부종 20명(19%), 가슴막삼출 20명(19%), 간질폐렴 2명(2%)이었다. CRP는 평균 8.87${\pm}$7.29 mg/dl였고 20 mg/dl 이상의 높은 값을 보였던 환자도 8명 있었고 폐침범 중 간질폐렴 형태에서 가장 높은 평균값을 보였다(p=0.027). 폐합병증을 보였던 환자군에서 임상적으로 심한 경과를 보였으며 중환자실 입원치료와 인공호흡기 치료를 동반하고 있었고 더 높은 CRP값을 보였다(p=0.0073). 결 론: 급성열성질환에 있어서 폐합병증을 보인 군에서 더 높은 CPR 수치가 측정되었으며 입원 시 CRP측정을 통해 조기에 더 적극적인 치료가 필요한 환자군을 선택할 수 있고 폐침범에 의한 사망률과 치명률의 감소에도 도움이 될 것으로 추정된다.

토끼모델에서 저강도 맥동초음파가 골절치유에 미치는 영향 (The Effect of Low-Intensity Pulsed Ultrasound on Fracture Healing in the Rabbit Model)

  • 김종만;이충휘;조상현;박정미;권혁철;황태선
    • 한국전문물리치료학회지
    • /
    • 제9권1호
    • /
    • pp.81-96
    • /
    • 2002
  • The purpose of this research was to determine the effects on the healing of fibular fractures in rabbits of low-intensity pulsed ultrasound (50 $mW/cm^2$ and 500 $mW/cm^2$) applied for periods of 4, 14 and 24 days following fibular osteotomy. Thirty-six male Japanese white rabbits were randomly divided into three groups of twelve for three treatment protocols: (1) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 4th day following fibular osteotomy, (2) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 14th day following fibular osteotomy, and (3) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 24th day following fibular osteotomy. The low-intensity pulsed ultrasound was applied to only one fibula of each rabbit (these served as the experimental group). The other fibula of each rabbit served as the control group. The selection of which fibula was to be treated was made randomly. The animals were sacrificed on the 4th, 14th and 24th day after the start of ultrasound treatments. Percent of trabecular bone area and fibular radiography were carried out to compare the degree of fibular bone healing. A microscope was also used to determine any histologic changes. For statistical differences in radiological changes due to length of treatment period (4, 14 and 24 days respectively), the Wilcoxon signed-ranks test was used to compare the experimental and control groups. For statistical differences in fracture healing due to differences in ultrasound intensity, radiological studies were compared using the Mann-Whitney Test. And, to compute percentage differences in areas of trabecular bone, Two-way analysis of variance (ultrasound intensity x each group) was used. Experiment results were as follows: 1. In animals sacrificed on the 4th day, no difference was found in the radiological studies of the fibulae in the experimental and control groups (p>.05). However, experimental groups showed more rapid bone repair than control group. 2. Both radiographic and percent of trabecular bone area studies showed significant differences in rabbits sacrificed after 14 days. Fracture healing was significantly increased in the experimental group (p<.05) 3. In the animals sacrificed on the 24th day, histologic study showed rapid bone repair but fibular radiologic studies did not show statistical differences between the two groups (p>.05). 4. On the 14th day, bone union on radiograph was significantly more rapid in the treatment group with pulsed ultrasound of 50 $mW/cm^2$ than the group with 500 $mW/cm^2$ (p<.05). Histologic studies showed that both the 14 and 24 days groups had more rapid bone repair in animals treated with 50 $mW/cm^2$ ultrasound intensity than those treated with 500 $mW/cm^2$ intensity. In conclusion, it has been shown that the low-intensity pulsed ultrasound has a positive effect on bone fracture healing in the early stage and the range of pulse ultrasound from 50 $mW/cm^2$ to 500 $mW/cm^2$ is effective for fracture healing. Further study is needed to investigate the influence of pulsed ultrasound on delayed union and non-union in bone fractures and also for the clinical use of low-intensity pulsed ultrasound for bone healing in humans.

  • PDF

방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석 (The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System)

  • 나병식;정웅기;안성자;남택근;윤미선;송주영
    • 한국의학물리학회지:의학물리
    • /
    • 제16권2호
    • /
    • pp.82-88
    • /
    • 2005
  • 상용화된 방사선 치료계획 장치에서 제공하는 선량보상체(compensator) 설계 기능의 타당성 을 검증하고자 Cerrobend 재료를 대상으로 한 고밀도의 선량보상체 설계 및 제작과 동적다엽콜리메이터를 활용한 전자 선량보상체(Electronic Compensator)의 구현을 통해 그 기능을 분석하였다. 5개의 두께가 다른 영역으로 구성한 팬텀을 대상으로 전산화단층촬영(CT) 영상을 획득하고, 기준 깊이에서 균일한 선량분포를 형성하도록 방사선치료계획장치(RTP)에서 선량보상체를 설계하였다. Cerrobend 선량보상체 주조 틀을 제작하기 위해 컴퓨터로 자동 제어되는 스티로폼 절삭기를 사용하였고, 전자선량보상체를 구현하기 위해 다엽콜리메이터를 사용하였으며, 선량분포의 측정을 위해서 선량측정용 필름을 사용하였다. 선량보상체를 적용하지 않았을 경우, 선량분포에서 $\pm13.93 cGy$의 편차를 보였으나, Cerrobend 선량보상체와 전자선량보상체를 적용하였을 경우, 각각 $\pm0.99 cGy$$\pm1.82cGy$의 편차를 보여 선량분포의 균일도를 높이는 선량보상체로서 기능을 구현함을 증명하였다. 방사선치료계획장치에서 계획된 기준 선량값과의 평균 오차를 분석한 결과, Cerrobend 선량보상체는 $+3.83\%$, 전자 선량보상체는 $-4.37\%$의 오차를 보였으며, 이는 Cerrobend 선량보상체 제조과정에서의 오차와 절대 선량측정 도구로서 필름이 갖고 있는 한계성을 고려할 때, 선량보상체 기능의 정확도 입증에 타당성 있는 결과로 생각한다.

  • PDF

진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구 (A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea)

  • 김유현;최종학;김성수;이창엽;조평곤;이영배;김철민
    • 한국의학물리학회지:의학물리
    • /
    • 제16권1호
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA는 영상의 질에 영향을 주지 않는 범위에서 피부흡수선량의 기준선량을 제시하였다. 이러한 개념은 점차적으로 국제적인 기준으로 사용하게 되었다. 이 기준선량은 강제사항이 아니며 권고사항이지만 방사선촬영에서 아주 훌륭한 기준이 된다. 그러나 IAEA에서 제공한 선량기준은 서양 사람을 기준으로 개발된 것이어서 우리나라 사람에게는 맞지 않고, 상대적으로 우리나라의 환자선량은 적으리라 예상된다. 따라서 방사선촬영 시 촬영부위에 따른 환자 피폭선량에 대한 기준을 따로 개발해야 할 필요가 있다. 본 연구팀은 병원협회에 등록되어 있는 종합병원 278개를 대상으로 환자 피폭에 대한 설문조사를 실시하였다. 설문회수율은 57.9%였으며 각 병원에서 답한 촬영조건을 기초로 NDD법을 이용하여 환자 피폭선량을 계산하였고 방사선장치의 이용현황을 분석한 결과는 다음과 같다 1) 방사선장치의 현황은 일반촬영장치가 42.0%, 투시촬영장치가 29.4%, 치과장치가 13.2%, CT 장치가 8.1% 그리고 유방촬영장치가 7.2%로 나타났다. 2) 방사선장치의 정류방식에 따른 분류는 삼상장치가 29.9%, 인버터장치가 29.5%, 단상장치가 25.5%, 콘덴서방식이 9.0% 그리고 무응답이 6.0%였다. 3) 방사선장치의 수광방식에 따른 분류는 F/S 방식이 46.8%, CR 방식이 26.6%, DR 방식이 17.7% 그리고 무응답이 8.9%로 나타났다. 4) 방사선 촬영건수는 흉부가 49.2%, 척추가 16.8% 그리고 복부가 12.7%순으로 나타났다. 5) 환자 피폭선량은 두부 전후방향촬영 2.23 mGy, 복부 전후방향촬영 3.20 mGy 그리고 흉부 후전방향촬영 0.28 mGy로 나타났다.

  • PDF

방광요관역류의 진단에 있어서 자기공명 배뇨성 방광조영술의 유용성: 태뇨성 요도방광조영술과의 비교연구 (Magnetic Resonance Voiding Cystography in the Diagnosis of Vesicoureteral Reflux: Comparative Study with Voiding Cystourethrography)

  • Lee, Sang-Kwon;Chang, Yong-Min;Koo, Ja-Hoon;Ko, Cheol-Woo;Chung, Sung-Kwang;Kim, Tae-Hun;Sohn, Kyung-Sik;Lee, Chang-Hyun;Kim, Young-Hwan
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권2호
    • /
    • pp.85-93
    • /
    • 2000
  • 목적 : 방광요관역류의 진단에 있어서 자기공명 배뇨성 방광조영술의 유용성을 알아보고, 방광요관역류의 진단에 있어서 자기공명 배뇨성 방광조영술과 배뇨성 요도방광조영술의 민감도를 비교하고자 하였다. 대상 및 방법 : 방광요관역류가 의심되어 자기공명 배뇨성 방광조영술을 시행한 20명의 환아를 대상으로 하였다. 자기공명 배뇨성 방광조영술의 펄스 시권스는 생리식염수와 Gd-DTPA의 혼합액을 주입하기 전 후 및 배뇨직후의 관상면 spin-echo T1 강조영상 또는 gradient-echo 영상으로하였다. 자기공명 배뇨성 방광조영술의 소견은 최근 6개월이내에 시행한 배뇨성 요도방광조영술의 소견과 비교하였다. 결과: 방광요도역류는 23 신장요관단위에서 관찰되었으며, 16예에서는 두 가지 검사에서, 5예에서는 배뇨성 요도방광조영술에서만, 2예에서는 자기공명 배뇨성 방광조영술에서만 방광요관역류가 관찰되었다. 방광요관역류의 진단에있어서 배뇨성 요도방광조영술 및 자기공명 배뇨성 방광조영술의 민감도는 각각 91,3% (21/23)와 78.3% (18/23)였다. 신 피질 신티그래피로 진단된 17예의 신 손상중 15예에서 자기공명 배뇨성 방광조영술에서 신 손상의 소견이 관찰되었다. 결론: 자기공명 배뇨성 방광조영술은 방광요관역류의 진단에 있어서 배뇨성 요도방광조영술에 비해 민감도는 떨어지나, 방광요관역류와 신 손상 유무를 동시에 평가하기 위하여 이용되어질 수 있으며 , 따라서 반복적인 방사선 조사의 위험을 줄일 수 있다는 장점이 있다.

  • PDF

디지털 방사선사진술을 이용한 치아색 수복물의 방사선불투과도 비교 (RADIOPACITY COMPARISON OF TOOTH COLORED RESTORATIVE MATERIALS WITH DIGITAL RADIOGRAPHY)

  • 김효정;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.499-508
    • /
    • 2000
  • 본 연구에서는 이종의 디지털 방사선사진술이 수복물의 방사선불투과성 비교에 적절하게 이용될 수 있는지의 여부를 평가하고, 이 기법을 이용하여 수종의 compomer 및 유동성 레진의 방사선불투과도를 측정, 비교하고자 하였다. Aluminum step wedge를 방사선사진촬영 하여 기 존의 transmission densitometer와 CD-Dent (phosphor scanning system) 및 RVG$^{(R)}$ (CCD system) 등 두 종류의 디지털 방사선사진술과의 광학밀도 상관관계를 평가하였고, 두께 2mm, 지름 5mm인 원형의 금속주형을 이용하여 Dyract$^{(R)}$ AP, Compoglass$^{(R)}$ 및 Dyract flow$^{(R)}$ 등 3종의 compomer와 Ultraseal-XT$^{(R)}$ plus$^{TM}$, Revolution$^{TM}$, Aeliteflo$^{TM}$ 및 Tetric-flow$^{(R)}$ 등 4종의 유동성 레진의 시편을 각각 5개씩 제작후 방사선불투과성을 측정하고 비교, 평가하여 다음과 같은 결과를 얻었다. 1. Aluminum step wedge를 사용한 광학밀도 측정곡선을 비교한 바, 통상적인 방사선사진술로 얻은 필름의 상에서 transmission densitometer로 방사선불투과도를 측정 한 곡선과 CD-Dent 및 RVG$^{(R)}$ 등 디지털 방사선사진술로 얻은 상에서 CADIA로 불투과도를 측정한 곡선들 사이에서 각각 매우 높은 역상관관계가 나타났다(${\gamma}$=-0.95, ${\gamma}$=-0.98 ; p<0.05). 2. 모든 수복채 공히 상아질과 유사하거나 높은 방사선불투과도를 나타내었고 (p<0.05), compomer인 Dyract$^{(R)}$ AP와 Compoglass$^{(R)}$, 그리고 유동성 레진인 Tetric-flow$^{(R)}$는 통상적인 방사선사진술 및 2종의 디지털 방사선사진술에서 공히 유동성 레진인 Revolution$^{TM}$과 Aeliteflo$^{TM}$, 그리고 상아질에 비해 유의하게 높은 방사선불투과도를 나타내었다 (p<0.05). 3. Compomer인 Dyract$^{(R)}$ AP와 Compoglass$^{(R)}$, 그리고 유동성 레진인 Tetric-flow$^{(R)}$는 통상적인 방사선사진술 및 CD-Dent 디지털 방사선사진술에서 공히 법랑질에 비해 높은 방사선불투과도를 나타내었고(p<0.05), compomer인 Dyract flow$^{(R)}$는 통상적인 방사선사진술에서만 법랑질에 비해 높은 방사선불투과도를 나타내었다(p<0.05).

  • PDF

수종의 섬유 강화 레진 포스트의 방사선 불투과도와 식별도 평가 (EVALUATION OF RADIOPACITY AND DISCRIMINABILITY OF VARIOUS FIBER REINFORCED COMPOSITE POSTS)

  • 이은혜;최항문;박세희;김진우;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제35권3호
    • /
    • pp.188-197
    • /
    • 2010
  • 본 연구의 목적은 수종의 섬유 강화 레진 포스트의 방사선 불투과도와 식별도를 비교하고자 하는 것이다. 이번 실험을 위해 1) FRC Postec Plus (Ivoclar Vivadent AG, Schaan, Liechtenstein) 2) Snowlight (Carbotech, Lewis center, OH, USA) 3) Dentin Post (Komet Brasseler, Lamgo, Germany) 4) Rely-X Fiber Post (3M ESPE, St.paul, MN, USA) 5) D.T.-Light Post (BISCO, Schaumburg, IL,USA ) 6) Luxapost (DMG, Hamburg, Germany) 등 6종의 섬유 강화 레진 포스트를 사용하였다. 각 포스트를 참고 기준으로 사용한 1 mm, 2 mm 간격의 알루미늄 step-wedge와 함께 디지털센서를 사용하여 방사선 촬영하였다. 방사선 불투과도는 각 포스트의 다섯 지점에서 $10{\times}10$ 화소의 평균 회색조 값으로 계산하였고 동일 두께의 알루미늄 당량으로 비교하였다. 치아 시편으로 비슷한 방사선 불투과도를 보이는 상악 전치 6개에 포스트를 식립 후 건조 하악골의 설측에 위치시켜 방사선 사진을 촬영하였다. 포스트만을 촬영한 사진과 치아 시편의 방사선 사진들을 구강악안면방사선과 전공자 3명, 치과보존과 전공자 3명, 일반 치과 의사 3명에게 보여주고 설문지를 작성하도록 요청하였다. 설문지는 포스트와 포스트가 식립된 치아 시편 사진에서 방사선 불투과도가 가장 높은 포스트와 낮은 포스트를 고르는 문항, 치근단과 치관부 끝에서 인접 상아질과 가장 식별이 잘되는 포스트를 고르는 문항을 포함하였다. 실험의 결과는 다음과 같았다. 1. 각 FRC-Post는 다양한 방사선 불투과도를 보였다. 2. 가장 높은 방사선 불투과도와 가장 낮은 방사선 불투과도를 가지는 포스트를 고르는 질문에서 포스트만 나열한 경우 실험군 모두 100%의 정답률을 보였으나 포스트를 치아에 넣고 치조골을 중첩시킨 경우 정답률의 변화를 보였다. 3. 포스트 주변 상아질과 구분되는 정도를 묻는 질문에 대해 시편의 조합 순서를 바꾸자 일관된 식별 결과를 보이지 않았다. 이에 본 연구에 사용한 포스트는 다양한 방사선 불투과도를 보이나 식별 능력에 영향을 미칠 정도의 방사선 불투과도 차이를 보이지 않는 것으로 사료된다.