• Title/Summary/Keyword: Radiographic film

Search Result 122, Processing Time 0.029 seconds

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

COMPARISON OF JAW BONE DENSITY IN YOUNG ADULTS AND POSTMENOPAUSAL WOMEN (젊은 성인과 폐경 여성간의 악골 골밀도에 관한 비교 연구)

  • Kim, Tae-Sung;Lee, Dong-Keun;Lee, Byung-Do;Jung, Sun-Kwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.2
    • /
    • pp.107-114
    • /
    • 2001
  • Objectives : To compare jaw bone density of young adults (control group) and post-menopausal women(experimental group) in periapical and panoramic film. Materials and Methods : The bone mineral density values of lumbar and femur were measured by dual-energy X-ray absorptiometry(DEXA) and T scores of lumbar were obtained. T scores were classified into 3 group (T<-2.5, $-2.5{\leqq}T<-1$, $-1{\leqq}T$). Radiographic densities of alveolar bones were measured from interdental bones of premolar, molar areas in the maxilla and mandible and expressed into copper step wedge thickness by Scion $Image^{(R)}$ program. We considered these values of step wedge thickness as bone density of alveolar bone. Panorama mandibular index(PMI) was calculated by the method that the height of the inferior cortex of the mandible was divided by the height from the lower border of the mandible to the superior edge of the mental foramen. Bone density of alveolar bone and PMI were analysed statistically. Results : There were significant differences in bone mineral density of lumbar and femoral neck between control and experimental groups. There were also significant differences in bone density of premolar and molar area of jaw between control and experimental groups by MANOVA test. When considered lumbar T variables, there was only difference in interdental bone density of maxillary molar area between control and experimental group, but there was interaction. Interdental bone density of experimental group was appeared higher in $-1{\leqq}T$ group and lower in T<-2.5 group than control group. There was significant difference in PMI between control and experimental groups, but there was also inter action, thus, PMI of experimental group was appeared higher in $-1{\leqq}T$ group and lower in T<-2.5 group than control group. Conclusion : There were significant differences of alveolar density and cortical bone thickness between young men and post-menopausal women in periapical and panoramic film. These differences were dependent on lumbar T.

  • PDF

A Study on the Digital Mammography for Breast Cancer Patients (유방암 환자의 Digital Mammography에 관한 연구)

  • Lim, Cheong-Hwan;Lee, Sang-Ho;Jung, Hong-Ryang;Mo, Eun-Hui
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.63-71
    • /
    • 2012
  • This study aimed to evaluate the accuracy of breast cancer diagnosis of digital mammography which is in the highest interest of breast imaging test, and to investigate the characteristics of breast cancer patients. For this purpose, 57 breast cancer patients who underwent breast imaging test were examined between May 2010 and June 2011. The average age of the breast cancer patients was 50.8 years old, and the most frequently occurring location was the upper outer quadrant (UOQ), accounting for 33.3%. By age, the highest occurrence rate of breast cancer was the age group of 40~49, accounting for 42.1%. As for the breast composition of the breast cancer patients, fatty breast accounted for 31.6% (18/57) and dense breast for 68.4% (39/57), indicating that nearly 70% of the breast cancer patients have dense breast. It was found that the detection rate of breast cancer was the highest (45.3%) when both microcalcification and mass are simultaneously present in the radiographic lesion of the breast imaging. In dense breast, the mass without microcalcification was lower in detection rate than fatty breast. Accordingly, the mass is the cause of raising the false negative rate in dense breast. The findings show that the false negative rate of digital mammography was 7.0% and the sensitivity 93.0%. Also, the false negative rate of dense breast was 12.8%, and the sensitivity 87.2%, indicating that the sensitivity to breast cancer in this study was higher than the dense breast of previously reported screen film mammography.

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

Radiographic evaluation of alveolar bone profile of maxillary anterior teeth in Korean young adult (한국인 성인의 상악 전치부 치조골 형태에 관한 방사선학적 연구)

  • Seo, Hyo-Seok;Chung, Chin-Hyung;Lim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.461-471
    • /
    • 2006
  • In order to achieve a satisfactory esthetic result of periodontal surgery or implant in maxillary anterior area, periodontists must be aware of normal alveolar bone anatomy. The purpose of this study was to evaluate the relationship of alveolar bone morphology to tooth shape and form. 78(mean age : 25 yrs) periodontally healthy volunteers participated in this study. Two maxillary central incisor and one lateral incisor were selected to study. With minimal local anesthesia, gutta-percha cone inserted to labial gingival sulcus of selected teeth just after bone sounding with periodontal probe. Metal ball (4mm diameter) attached to palatal fossa of central incisor. Then, periapical radiograph was taken according to long cone paralleling technique. After film scan, labial alveolar bone profile reproduced along interproximal bone and apical ends of gutta-percha cones on computer screen. By utilizing computer program, the distance from height of interproximal bone to the labial bone crest in central incisor-central incisor and central incisor-lateral incisor area was measured and converted to real distance by using vertical length of metal ball on film. After measuring crown length & width of central incisor, the 10 individuals ranked lowest GW/L ratio (crown width/length ratio) and the 10 ranked highest were selected as having a long-narrow(group N), or a short-wide(group W) form of the central incisors. Means of the distance from height of interproximal bone to the labial bone crest of group N, W were calculated and compared by means of independent t-test. The results were as follows: 1. Mean distance from the height of the interproximal bone to the labial bone crest was $3.5{\pm}0.7mm$ between two central incisor, and $2.8{\pm}0.6mm$ between central and lateral incisor. 2. Mean GW/L ratio of group N was 0.57, and group W was 0.8. Mean distance from the height of the interproximal bone to the labial bone crest of group N was higher than group W in both measured area(measurements of group N, W were $3.9{\pm0.2mm$ and $3.5{\pm}0.2mm$ between two central incisor, $3.0{\pm}0.2mm$ and $2.8{\pm}0.2mm$ between central and lateral incisor), but there were no statistically significant differences when the groups were compared. Within the limits of the present study, there was a tendency that subjects with long-narrow teeth have more scalloped alveolar bone profile than subjects with short-wide teeth in upper anterior area, but no statistically significant differences were found.

Survery on Business of the Departments of Radiology in Health Centers (보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

AUGMENTED BONY CHANGE FOLLOWING PLATELET RICH PLASMA(PRP) APPLICATION ON MAXILLARY DEFECT (악골결손부에 PRP적용후 획득된 골의 변화량)

  • Kim, Uk-Kyu;Kim, Yong-Deok;Byun, June-Ho;Shin, Sang-Hun;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.219-225
    • /
    • 2003
  • Purpose: Platelet Rich Plasma(PRP) application is increasing with sinus inlay bone graft, but there is few research with radiographic ananlysis on effect of PRP in maxillary sinus. The author investigated the amount of bony changes of maxillary sinus for dental implantation among the patients with maxillary inlay graft. Materials and Methods: With 10 patients who were treated with sinus inlay autologous bone grafting combined with PRP technique, and with 5 patients who were treated with sinus inlay grafting only without PRP, the panoramic radiographys which were taken at preoperation, immediate postoperation, 3months postoperation, and 4 months postoperation(a month after dental implantation)periods were analysed. The films had been scanned, and then proceeded throughout image analysis system. The bone density of maxillary grafted sites was compared with adjacent tooth enamel density and remeasured according to density luminosity of each film. The density changes on PRP group and bone graft only group were analysed with non-parameteric statistics method. Results: In PRP combined patients group, bone density on postoperation periods was increased totally. The remarkable enhanced change of bone density was observed on 3 months postoperation period, thereafter the increasing rate was slightly reduced. In only bone graft patients group, bone density on postoperation periods was also increased compared with preoperation period, but the bone density of 4 months postoperation period was decreased compared with 3 months postoperation period. The amount of bone density on PRP group was significantly changed according to periods in contrast to bone graft only group. Conclusion: The bone density on PRP group was remarkably increased at 3 months postoperation compared to bone graft only group and it was seemed to be associated with more new bone formation, less grafted bone resorption at bone grafted sites with PRP.

Dose Verification of Intensity Modulated Radiation Therapy with Beam Intensity Scanner System

  • Vahc, Young-Woo;Park, Kwangyl;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.248-251
    • /
    • 2002
  • The intensity modulated radiation therapy (IMRT) with a multileaf collimator (MLC) requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC during radiation treatment of patients. Patient dose verification is clinically one of the most important parts in the treatment delivery of the radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to the target helps to verify patient dose and to determine the physical characteristics of beams used in IMRT. A new method is presented for the pretreatment dosimetric verification of two dimensional distributions of photon intensity by means of Beam Intensity Scanner System (BISS) as a radiation detector with a custom-made software for dose calculation of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The BISS reproduces 3D- relative dose distribution from the digitized fluoroscopic signals obtained by digital video camera-based scintillator(DVCS) device in the IMRT. For the intensity modulated beams (IMBs), the calculations of absorbed dose are performed in absolute beam fluence profiles which are used for calculation of the patient dose distribution. The 3D-dose profiles of the IMBs with the BISS were demonstrated by relative measurements of photon beams and shown good agreement with radiographic film. The mechanical and dosimetric properties of the collimating of dynamic and/or step MLC system alter the generated intensity. This is mostly due to leaf transmission, leaf penumbra and geometry of leaves. The variations of output according to the multileaf opening during the irradiation need to be accounted for as well. These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

COMPARATIVE STUDY OF DIGITAL AND CONVENTIONAL RADIOGRAPHY FOR THE DIAGNOSTIC ABILITY OF ARTIFICIAL PROXIMAL SURFACE CARIES (디지털방사선사진과 구내방사선사진의 인접면 인공우식진단능에 관한 비교연구)

  • Cho, Young-Gon;Park, Si-Seung
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.113-121
    • /
    • 2002
  • Conventional intraoral radiography continues to be the most widely used image modality for the diagnosis of dental caries. But, conventional intraoral radiography has several shortcomings, including the difficulty of exposing and processing intraoral film of consistently acceptable quality. In addition, radiographic retaking that was the result of processing errors, may result in increased discomfort and radiation dose to the patient. Recently, various digital radiographies substitute for conventional intraoral radiography to overcome these disadvantages. The advantages of digital radiography are numerous. One of advantages Is the elimination of processing errors. In addition, the radiation dose for digital system is approximately 20% to 25% of that required for conventional intraoral radiography Another potential advantage of digital imaging is the ability to perform image quality enhancements such as contrast and density modulation, which may increase diagnostic accuracy. The purpose of this study was to compare the diagnostic ability of artificial proximal defects to conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). Artificial defects were made in proximal surfaces of 60 extracted human molars using #1/2, #1, #2 round bur. Five dentists assessed proximal defects on conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). ROC(Receiver Operating Characteristic) analysis and Two-way ANOVA test were used for the evaluation of detectability, and following results were acquired. 1. The mean ROC area of conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital Image(Digora$^{\circledR}$) were 0.6766, 0.7538, 0.6791(Grade I), 0.7176, 0.7594, 0.7361(Grade II), and 0.7449, 0.7608, 0.7414(Grade III), respectively. 2. Diagnostic ability of direct digital image was higher than other image modalities. But, there was no statistically significant difference among other imaging modalities for Grade I, II, III lesion(p>0.05). In conclusion, when direct and indirect digital system are comparable with conventional intraoral radiography. these systems may be considered an alternative of conventional intraoral radiography for the diagnosis of proximal surface caries.

Effect of Type I Collagen on Hydroxyapatite and Tricalcium Phosphate Mixtures in Rat Calvarial Bony Defects

  • Kim, Jung-Hwan;Kim, Soung-Min;Kim, Ji-Hyuck;Kwon, Kwang-Jun;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.1
    • /
    • pp.36-48
    • /
    • 2008
  • To repair bone defects in the oral and maxillofacial field, bone grafts including autografts, allografts, and artificial bone are used in clinical dentistry despite several disadvantages. The purpose of this study was to evaluate new bone formation and healing in rat calvarial bone defects using hydroxyapatite (HA, $Ca_{10}[PO_4]_6[OH]_2,\;Bongros^{(R)}$, Bio@ Co., KOREA) and tricalcium phosphate (${\beta}-TCP,\;Ca_3[PO_4]_2$, Sigma-Aldrich Co., USA) mixed at various ratios. Additionally, this study evaluated the effects of type I collagen (Rat tail, BD Biosciences Co., Sweden) as a basement membrane organic matrix. A total of twenty, 8-week-old, male Sprague-Dawley rats, weighing 250-300g, were divided equally into a control group (n=2) and nine experimental groups (n=2, each). Bilateral, standardized transosseous circular calvarial defects, 5.0 mm in diameter, were created. In each experimental group, the defect was filled with HA and TCP at a ratio of 100:0, 80:20, 70:30, 60:40, 50:50, 40:60, 30:70, 20:80, and 0:100 with or without type I collagen. Rats were sacrificed 4 and 8 weeks post-operation for radiographic (standardized plain film, Kodak Co., USA), histomorphologic (H&E [Hematoxylin and Eosin], MT [Masson Trichrome]), immunohistochemical staining (for BMP-2, -4, VEGF, and vWF), and elementary analysis (Atomic absorption spectrophotometer, Perkin Elmer AAnalyst $100^{(R)}$). As the HA proportion increased, denser radiopacity was seen in most groups at 4 and 8 weeks. In general radiopacity in type I collagen groups was greater than the non-collagen groups, especially in the 100% HA group at 8 weeks. No new bone formation was seen in calvarial defects in any group at 4 weeks. Bridging bone formation from the defect margin was marked at 8 weeks in most type I collagen groups. Although immunohistochemical findings with BMP-2, -4, and VEGF were not significantly different, marked vWF immunoreactivity was present. vWF staining was especially strong in endothelial cells in newly formed bone margins in the 100:0, 80:20, and 70:30 ratio type I collagen groups at 8 weeks. The calcium compositions from the elementary analysis were not statistically significant. Many types of artificial bone have been used as bone graft materials, but most of them can only be applied as an inorganic material. This study confirmed improved bony regeneration by adding organic type I collagen to inorganic HA and TCP mixtures. Therefore, these new artificial bone graft materials, which are under strict storage and distribution systems, will be suggested to be available to clinical dentistry demands.