• Title/Summary/Keyword: Radiographic Testing

Search Result 71, Processing Time 0.022 seconds

Comparison Research of SNR and SRb with Bright Calibration and Multi Frame Images in Digital Radiography of Welded Test Components (용접 시험편의 디지털 방사선 검사에서 밝기 교정과 중첩 영상에 따른 SNR 및 SRb 비교 연구)

  • Nam, Mun-Ho;Yang, Jin-Wook;Cho, Kap-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.731-739
    • /
    • 2021
  • This work compared the bright calibration of digital radiation with signal-to-noise ratio and basic spatial resolution according to multi frame to enable effective inspection of welding parts of structures at industrial sites. A total of 130 images were obtained by using a 75Se radiation source for flat weld test pieces and segmenting bright calibration and multi frame prior to shooting. The study confirms that the signal-to-noise ratio improves as the number of bright calibrations and the number of multi frame increases. The basic spatial resolution satisfied the baseline for both radiographic images. It was confirmed that the number of signal-to-noise ratio was similar by comparing images taken after installing lead shielding for scattering radiation. Although signal-to-noise ratio increases as multi frame increases, it is believed that good quality digital radiographs can be obtained if appropriate radiographic techniques are devised because exposure time of radiation affects workers' exposure and work efficiency.

Vertical Space Analysis for Gradient Radiating Steel-tube Radiographic Image (경사조사(傾斜照射) 강판튜브 방사선 관측영상의 수직 방향 공간분석)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.29-31
    • /
    • 2007
  • In this paper we propose an directional analytic approach in image data space for X-ray image which is detected from the X-ray projection system. Such a radiographic nondestructive testing has long been used for steel-tube inspection and weld monitoring. The welded area and thickness of steel-tube are detected from gradient radiating mechanism based on the evaluation of biased X-ray source position. The welded area is an ellipse type on low contrast X-ray image including noise. Noise originates from most of elements of the system. such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc.. Projection incorrectness and noise influence on imaging quality is to be represented by vertical pixels' distribution. Space analysis due to vertical direction also shows the segmental possibility between regions by visual edge evaluation.

  • PDF

Segmentation of Welding Defects using Level Set Methods

  • Mohammed, Halimi;Naim, Ramou
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.1001-1008
    • /
    • 2012
  • Non-destructive testing (NDT) is a technique used in science and industry to evaluate the properties of a material without causing damage. In this paper we propose a method for segmenting radiographic images of welding in order to extract the welding defects which may occur during the welding process. We study different methods of level set and choose the model adapted to our application. The methods presented here take the property of local segmentation geodesic active contours and have the ability to change the topology automatically. The computation time is considerably reduced after taking into account a new level set function which eliminates the re-initialization procedure. Satisfactory results are obtained after applying this algorithm both on synthetic and real images.

Method of Radiographic Examination for Welded Joints in Steel(KS B 0845) - Explanation (강 용접이음의 방사선투과시험 방법(KS B 0845) 해설)

  • Chung, Ku-Pom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.223-240
    • /
    • 1998
  • 본 고는 1997년 12월 31일 개정된 "강 용접부의 방사선투과시험 방법 및 투과 사진의 등급분류 방법" (한국산업규격 KS B 0845)을 이해하는데 참고가 될 수 있도록 일본공업규격 JIS Z 3104의 해설부분을 번역한 것으로 KS B 0845의 모체가 되는 JIS Z 3104의 본래취지를 정확히 전달하기 위하여 편집하거나 가감하지 않고 원문 그대로 기술하였으며 KS B 0845와는 일부 용어나 항목구성에 차이가 있으나 번호에 관계없이 각항목의 제목을 보고 이해하게 하였다. 특히 일부 부속 규격의 미 제정상태에서 개정판이 발표되어 적용에 혼란을 초래할 수도 있겠으나 부분적인 적용은 가능할 것으로 판단된다.

  • PDF

Image Processing Algorithms for Non-destructive Testing

  • Lee, SangBock
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.9
    • /
    • pp.45-49
    • /
    • 2016
  • In this study, an image processing algorithm was developed to increase readability of the images of specific parts of a KTX train acquired by using a mobile digital radiographic testing device in a situation where a running train is stopped. The image processing algorithm was realized by using a Visual C++ development tool. The algorithm developed in this study allows to select an interested region in the acquired images when the interested region is suspected to cause a problem, and applies a thinning process based Sobel operators to the selected region. The experimental results show that the readability of defect parts that are not visible to naked eyes was increased through edge detector. Application of the algorithm developed in this study may help to accurately read non-destructive inspection images.

Comparison of the Incidence and Risk Factors for Developing Osteoarthritis after ACL Reconstruction - Patellar Versus a Hamstring Autograft - (전방 십자 인대 재건술 후 골관절염의 발생 빈도 및 위험 인자들에 대한 비교 - 자가 슬개건과 자가 슬괴건을 이용한 방법 -)

  • Song, Eun-Kyoo;Seon, Jong-Keun;Kim, Hyung-Soon;Kang, Kyung-Do;Byun, Jae-Wook
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.9 no.1
    • /
    • pp.48-57
    • /
    • 2010
  • Purpose: To compare the incidence and risk factors for osteoarthritis after anterior cruciate ligament (ACL) reconstruction between two groups using bone-patellar tendon-bone (BPTB) and hamstring tendon (HT) autograft. Materials and Methods: 53 cases of ACL reconstruction using patellar tendon and 40 cases using hamstring tendon were followed up at least 8 years. Radiographic evaluation was done according to the Kellgren and Lawrence's classification. Clinical functional testing (Lysholm Knee Scores, the Tegner activity scores) and laxity testing (Lachman, pivot shift tests), and the instrumented laxity testing with $Telos^{(R)}$ were all examined in relation to the development of osteoarthritis. Results: Radiographic osteoarthritic changes were detected in 24 patients (45.3%) in BPTB group and 14 patients (35.0%) in HT group. Accompanying meniscal injury (BPTB p<0.001; HT p=0.091), intervals from the injury to reconstruction of > 12 months (BPTB p=0.037; HT p=0.021), and patient's age at reconstruction of > 25 years (BPTB p=0.003; HT p=0.048) were found to be significant independent predictors of osteoarthritis. However, no statistically significant correlations were found between the development of osteoarthritis and the clinical outcome or the radiographic stability in both groups. Conclusion: Although ACL reconstruction using BPTB or HT autograft had good clinical results at an average follow-up of 10 years, considerable incidence of radiographic osteoarthritic changes were noted. Various factors such as accompanying meniscal injury, protracted time from injury to reconstruction, more than 25 years old at the time of reconstruction were related to radiographic osteoarthritic changes.

  • PDF

The Basic Study on the Method of Acoustic Emission Signal Processing for the Failure Detection in the NPP Structures (원전 구조물 결함 탐지를 위한 음향방출 신호 처리 방안에 대한 기초 연구)

  • Kim, Jong-Hyun;Korea Aerospace University, Jae-Seong;Lee, Jung;Kwag, No-Gwon;Lee, Bo-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.485-492
    • /
    • 2009
  • The thermal fatigue crack(TFC) is one of the life-limiting mechanisms at the nuclear power plant operating conditions. In order to evaluate the structural integrity, various non-destructive test methods such as radiographic test, ultrasonic test and eddy current are used in the industrial field. However, these methods have restrictions that defect detection is possible after the crack growth. For this reason, acoustic emission testing(AET) is becoming one of powerful inspection methods, because AET has an advantage that possible to monitor the structure continuously. Generally, every mechanism that affects the integrity of the structure or equipment is a source of acoustic emission signal. Therefore the noise filtering is one of the major works to the almost AET researchers. In this study, acoustic emission signal was collected from the pipes which were in the successive thermal fatigue cycles. The data were filtered based on the results from previous experiments. Through the data analysis, the signal characteristics to distinguish the effective signal from the noises for the TFC were proven as the waveform difference. The experiment results provide preliminary information for the acoustic emission technique to the continuous monitoring of the structure failure detection.

Evaluation of thermal shock resistance and thermal shock fracture toughness using $CO_2$ laser for ATJ graphite (ATJ 그라파이트의 $CO_2$ 레이저를 이용한 열충격 강도 및 열충격 파괴인성 평가)

  • Kim, Jae-Hoon;Lee, Young-Sin;Park, No-Seok;Kim, Duk-Hoi;Han, Young-Wook;Seo, Jung;Kim, Jung-Oh
    • Laser Solutions
    • /
    • v.6 no.1
    • /
    • pp.17-24
    • /
    • 2003
  • The purpose of this study is to evaluate thermal shock resistance and thermal shock fracture toughness for ATJ graphite. Thermal shock resistance and thermal shock fracture toughness of ATJ graphite are evaluated by using CO$_2$ laser irradiation technique. The laser heat source is irradiated at the center of specimens. Temperature distribution on the specimen surface is measured using the thermocouples of type K and C. SEM and radiographic images are used to observe the cracks which are formed at the thermal shock specimens.

  • PDF

Voxel-Based Thickness Analysis of Intricate Objects

  • Subburaj, K.;Patil, Sandeep;Ravi, B.
    • International Journal of CAD/CAM
    • /
    • v.6 no.1
    • /
    • pp.105-115
    • /
    • 2006
  • Thickness is a commonly used parameter in product design and manufacture. Its intuitive definition as the smallest dimension of a cross-section or the minimum distance between two opposite surfaces is ambiguous for intricate solids, and there is very little reported work in automatic computation of thickness. We present three generic definitions of thickness: interior thickness of points inside an object, exterior thickness for points on the object surface, and radiographic thickness along a view direction. Methods for computing and displaying the respective thickness values are also presented. The internal thickness distribution is obtained by peeling or successive skin removal, eventually revealing the object skeleton (similar to medial axis transformation). Another method involves radiographic scanning along a viewing direction, with minimum, maximum and total thickness options, displayed on the surface of the object. The algorithms have been implemented using an efficient voxel based representation that can handle up to one billion voxels (1000 per axis), coupled with a near-real time display scheme that uses a look-up table based on voxel neighborhood configurations. Three different types of intricate objects: industrial (press cylinder casting), sculpture (Ganesha idol), and medical (pelvic bone) were used for successfully testing the algorithms. The results are found to be useful for early evaluation of manufacturability and other lifecycle considerations.

A Study on the Radiograph Inspection of Specimen in Welding Pass Using ATOS 80 High-strength Steel (ATOS 80 고장력강의 용접 패스에 따른 용접부 방사선검사에 관한 연구)

  • Baek, Jung-Hwan;Choi, Byung-Ky
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.915-919
    • /
    • 2012
  • In constructing all kinds of equipment and steel structure, parts with discontinuities such as weld defects formed in the welded structure can generate fatigue cracks that results in damage or accidents. In this study, weld zones are investigated with X-rays and the latent images are put on film. Weld zone defects can be verified by developing the film. As weld defects are investigated by radiographic testing and correlated with the welding condition, more appropriate welding conditions can be found. According to the result of X-ray radiographic inspection of butt welding ATOS 80 high-strength steel with a thickness of 12mm, the best conditions for welding without creating weld defects are 4 weld-passes, a protective gas of 20% $CO_2$ and 80% Ar, a protective gas flow of 20L/min, a welding current of 200A, an arc voltage of 24V, a welding speed of 14.4cm/min, a welding rod angle of $50^{\circ}$, a welding gap of 5 mm with a ceramic base, and sand pre-heating to $160^{\circ}$ Celsius prior to welding.