• 제목/요약/키워드: Radiographic Test

검색결과 292건 처리시간 0.028초

Intentional passive eruption combined with scaling and root planing of teeth with moderate chronic periodontitis and traumatic occlusion

  • Joo, Ji-Young;Kwon, Eun-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • 제44권1호
    • /
    • pp.20-24
    • /
    • 2014
  • Purpose: The aim of this clinical trial was to explore the impact of intentional passive eruption (IPE) using occlusal reduction on the periodontal parameters of teeth with moderate chronic periodontitis and traumatic occlusion. Methods: This study was performed on 40 teeth from 16 subjects. At baseline, 4 weeks after initial periodontal treatment, and 6 months after IPE, clinical and radiographic examinations were performed. The 20 teeth in the test group underwent IPE using occlusal reduction, whereas the 20 control teeth did not undergone occlusal reduction. Results: All the periodontal parameters were improved by the initial periodontal treatment. The teeth in the test group showed a significantly greater decrease in pocket depth, tooth mobility, and marginal bone loss than did the control group (P<0.05), but there were no significant changes in the attachment level. Significantly greater improvements in all the parameters were observed in the test group after 6 months of IPE compared to 4 weeks after the initial periodontal treatment (P<0.05). Conclusions: Within the limits of this study, performing initial periodontal therapy combined with IPE using occlusal reduction was shown to be very simple and effective. Moreover, IPE would be helpful in improving periodontal parameters.

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

Derivation of External Exposure Characteristics of Industrial Radiography Based on Empirical Evidence

  • Cho, Junik;Kim, Euidam;Kwon, Tae-Eun;Chung, Yoonsun
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.93-98
    • /
    • 2022
  • Background: This study aims to derive the characteristics of each work type for industrial radiography based on empirical evidence through expert advice and a survey of radiation workers of various types of industrial radiography. Materials and Methods: According to a Korean report, work types of industrial radiography are classified into indoor tests, underground pipe tests, tests in a shielded room (radiographic testing [RT] room test), outdoor field tests, and outdoor large structure tests. For each work type, exposure geometry and radiation sources were mainly identified through the expert advice and workers' survey as reliable empirical evidence. Results and Discussion: The expert advice and survey results were consistent as the proportion of the work types were high in the order of RT room test, outdoor large structure test, underground pipe test, outdoor field test, and indoor test. The outdoor large structure test is the highest exposure risk work type in the industrial radiography. In most types of industrial radiography, radiation workers generally used 192Ir as the main source. In the results of the survey, the portion of sources was high in the order of 192Ir, X-ray generator, 60Co, and 75Se. As the exposure geometry, the antero-posterior geometry is dominant, and the rotational and isotropic geometry should be also considered with the work type. Conclusion: In this study, through expert advice and a survey, the external exposure characteristics for each work type of industrial radiography workers were derived. This information will be used in the reconstruction of organ dose for health effects assessment of Korean radiation workers.

Radiographic study of the distribution of maxillary intraosseous vascular canal in Koreans

  • Lee, JuHyon;Kang, Nara;Moon, Young-Mi;Pang, Eun-Kyoung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.1.1-1.4
    • /
    • 2016
  • Background: This study aimed to investigate the distribution and prevalence of intraosseous loop (anastomosis between posterior superior alveolar artery and infraorbital artery) in Koreans detected on computed tomography (CT) images taken prior to sinus augmentation surgery. Methods: From the 177 patients who underwent sinus augmentation with lateral approach at Ewha Womans University Department of Implant Dentistry, 284 CT scans were evaluated. The canal height (CH), ridge height (RH), and canal height from the sinus floor (CHS) were measured on para-axial views at the first premolar, first molar, and second molar. The horizontal positions of the bony canals in the lateral wall were also classified. One-way analysis of variance (ANOVA) and t test were used to estimate the statistical differences (p < 0.05). Results: The intraosseous loops were detected in 92 CT scans (32 %). The mean vertical height of the bony canals from the alveolar crest (CH) was $23.45{\pm}2.81$, $15.92{\pm}2.65$, and $16.61{\pm}2.92mm$ at the second premolar, first molar, and second molar, respectively. In the horizontal positions of the bony canals, intraosseous type was the most predominant. The canal heights more than 15 mm and less than 17 mm were most prevalent (33.7 %) and those under 13 mm were 12.0 %. Conclusions: The radiographic findings in this study could be used to decide the lateral osteotomy line avoiding potential vascular complication. However, only one third of the canals could be detected in CT scans; a precaution should be taken for the possibility of severe bleeding during lateral osteotomy.

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

Diagnosis and prediction of periodontally compromised teeth using a deep learning-based convolutional neural network algorithm

  • Lee, Jae-Hong;Kim, Do-hyung;Jeong, Seong-Nyum;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제48권2호
    • /
    • pp.114-123
    • /
    • 2018
  • Purpose: The aim of the current study was to develop a computer-assisted detection system based on a deep convolutional neural network (CNN) algorithm and to evaluate the potential usefulness and accuracy of this system for the diagnosis and prediction of periodontally compromised teeth (PCT). Methods: Combining pretrained deep CNN architecture and a self-trained network, periapical radiographic images were used to determine the optimal CNN algorithm and weights. The diagnostic and predictive accuracy, sensitivity, specificity, positive predictive value, negative predictive value, receiver operating characteristic (ROC) curve, area under the ROC curve, confusion matrix, and 95% confidence intervals (CIs) were calculated using our deep CNN algorithm, based on a Keras framework in Python. Results: The periapical radiographic dataset was split into training (n=1,044), validation (n=348), and test (n=348) datasets. With the deep learning algorithm, the diagnostic accuracy for PCT was 81.0% for premolars and 76.7% for molars. Using 64 premolars and 64 molars that were clinically diagnosed as severe PCT, the accuracy of predicting extraction was 82.8% (95% CI, 70.1%-91.2%) for premolars and 73.4% (95% CI, 59.9%-84.0%) for molars. Conclusions: We demonstrated that the deep CNN algorithm was useful for assessing the diagnosis and predictability of PCT. Therefore, with further optimization of the PCT dataset and improvements in the algorithm, a computer-aided detection system can be expected to become an effective and efficient method of diagnosing and predicting PCT.

Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up

  • Alrabiah, Mohammed;Deeb, Modhi Al;Alsahhaf, Abdulaziz;AlFawaz, Yasser F.;Al-Aali, Khulud Abdulrahman;Vohra, Fahim;Abduljabbar, Tariq
    • Journal of Periodontal and Implant Science
    • /
    • 제50권2호
    • /
    • pp.97-105
    • /
    • 2020
  • Purpose: The present retrospective clinical study aimed to evaluate and compare the clinical and radiographic parameters, complications, and satisfaction in patients who received fixed prostheses supported by narrow-diameter implants (NDIs) in the anterior and posterior jaw. Methods: Patients aged ≥30 years who had NDI-supported fixed prostheses in the anterior or posterior region of either jaw for at least 2 years were included. Complications such as chipping of the crown; loosening or fracture of the screw, crown abutment, or implant; and loss of retention were recorded. Clinical peri-implant outcomes and crestal bone loss (CBL) were measured. A questionnaire was used to record responses regarding the aesthetics and function of the fixed restorations. Analysis of variance was used to assess the significance of between-group mean comparisons. The log-rank test was performed to analyze the influence of location and prosthesis type on technical complications. Results: Seventy-one patients (mean age: 39.6 years) provided informed consent with a mean follow-up duration of 53 months. Only bleeding on probing showed a statistically significant difference between NDIs in the anterior and posterior regions. The complication rate for NDIs in the posterior region was significantly higher than that for NDIs in the anterior region (P=0.041). For NDIs, CBL was significantly higher around splinted crowns than single crowns (P=0.022). Overall mean patient satisfaction was 10.34±3.65 on a visual analogue scale. Conclusions: NDIs in the anterior and posterior jaws functioned equally well in terms of periimplant soft and hard tissue health and offered acceptable patient satisfaction and reasonable complication rates.

Implant-supported overdentures with different bar designs: A retrospective evaluation after 5-19 years of clinical function

  • Rinke, Sven;Rasing, Hajo;Gersdorff, Nikolaus;Buergers, Ralf;Roediger, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.338-342
    • /
    • 2015
  • PURPOSE. This retrospective study evaluated the outcome of implant-retained overdentures (IODs) after 5-19 years of clinical function. MATERIALS AND METHODS. A retrospective analysis of patient files was performed referring to 27 patients who received 36 IODs with 3 different bar designs (group A=prefabricated round bars, n=7; group B=one-piece anterior milled bars, n=20; and group C=two bilaterally placed milled bars, n=9) in the mandible (n=24) and/or in the maxilla (n=12). The analysis focused on the survival and success rates (according to Kaplan-Meier) of the implants and prostheses. Technical complication rates for each type of restoration were analyzed and compared via one-way ANOVA and the Chi-squared test. The prevalence of peri-implantitis (radiographic bone loss ${\geq}3.5mm$) was evaluated by digital analysis of panoramic radiographs taken postoperative (baseline) and after 5-19 years of clinical function (follow-up). RESULTS. The mean observational time was 7.3 years. The survival rates of the prostheses and implants were 100% and 97.7%, respectively. Technical complications occurred more frequently in group A (mean: 3.5 during observational time) than in the other two groups (B: 0.8; C: 1.0). However, this difference was not statistically significant (P=0.58). Peri-implantitis was diagnosed for 12.4% of the implants in 37% of the patients. CONCLUSION. Bar-retained IODs are an adequate treatment option for edentulous jaws. These restorations may exhibit high implant/prosthesis survival rates (>97%), and a limited incidence of technical complications after a mean observational period of >7 years. Nevertheless, peri-implantitis was identified as a frequent and serious biological complication for this type of reconstruction.

The hidden X suture: a technical note on a novel suture technique for alveolar ridge preservation

  • Park, Jung-Chul;Koo, Ki-Tae;Lim, Hyun-Chang
    • Journal of Periodontal and Implant Science
    • /
    • 제46권6호
    • /
    • pp.415-425
    • /
    • 2016
  • Purpose: The present study investigated the impact of 2 different suture techniques, the conventional crossed mattress suture (X suture) and the novel hidden X suture, for alveolar ridge preservation (ARP) with an open healing approach. Methods: This study was a prospective randomized controlled clinical trial. Fourteen patients requiring extraction of the maxillary or mandibular posterior teeth were enrolled and allocated into 2 groups. After extraction, demineralized bovine bone matrix mixed with 10% collagen (DBBM-C) was grafted and the socket was covered by porcine collagen membrane in a double-layer fashion. No attempt to obtain primary closure was made. The hidden X suture and conventional X suture techniques were performed in the test and control groups, respectively. Cone-beam computed tomographic (CBCT) images were taken immediately after the graft procedure and before implant surgery 4 months later. Additionally, the change in the mucogingival junction (MGJ) position was measured and was compared after extraction, after suturing, and 4 months after the operation. Results: All sites healed without any complications. Clinical evaluations showed that the MGJ line shifted to the lingual side immediately after the application of the X suture by $1.56{\pm}0.90mm$ in the control group, while the application of the hidden X suture rather pushed the MGJ line slightly to the buccal side by $0.25{\pm}0.66mm$. It was demonstrated that the amount of keratinized tissue (KT) preserved on the buccal side was significantly greater in the hidden X suture group 4 months after the procedure (P<0.05). Radiographic analysis showed that the hidden X suture had a significant effect in preserving horizontal width and minimizing vertical reduction in comparison to X suture (P<0.05). Conclusions: Our study provided clinical and radiographic verification of the efficacy of the hidden X suture in preserving the width of KT and the dimensions of the alveolar ridge after ARP.

Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study

  • De Molon, Rafael Scaf;Morais-Camillo, Juliana Aparecida Najarro Dearo;Sakakura, Celso Eduardo;Ferreira, Mauricio Goncalves;Loffredo, Leonor Castro Monteiro;Scaf, Gulnara
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.243-247
    • /
    • 2012
  • Purpose: This study was performed to compare the inverted digital images and film-based images of dry pig mandibles to measure the periodontal bone defect depth. Materials and Methods: Forty 2-wall bone defects were made in the proximal region of the premolar in the dry pig mandibles. The digital and conventional radiographs were taken using a Schick sensor and Kodak F-speed intraoral film. Image manipulation (inversion) was performed using Adobe Photoshop 7.0 software. Four trained examiners made all of the radiographic measurements in millimeters a total of three times from the cementoenamel junction to the most apical extension of the bone loss with both types of images: inverted digital and film. The measurements were also made in dry mandibles using a periodontal probe and digital caliper. The Student's t-test was used to compare the depth measurements obtained from the two types of images and direct visual measurement in the dry mandibles. A significance level of 0.05 for a 95% confidence interval was used for each comparison. Results: There was a significant difference between depth measurements in the inverted digital images and direct visual measurements (p>|t|=0.0039), with means of 6.29 mm ($IC_{95%}$:6.04-6.54) and 6.79 mm ($IC_{95%}$:6.45-7.11), respectively. There was a non-significant difference between the film-based radiographs and direct visual measurements (p>|t|=0.4950), with means of 6.64mm($IC_{95%}$:6.40-6.89) and 6.79mm($IC_{95%}$:6.45-7.11), respectively. Conclusion: The periodontal bone defect measurements in the inverted digital images were inferior to film-based radiographs, underestimating the amount of bone loss.