• Title/Summary/Keyword: Radiographic Test

Search Result 286, Processing Time 0.026 seconds

Correlation between sagittal condylar guidance angles obtained using radiographic and protrusive occlusal record methods

  • Kwon, Oh-Kyun;Yang, Seung-Won;Kim, Jee-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.302-307
    • /
    • 2017
  • PURPOSE. This study compared the SCGAs measured in three types of radiographic images (panoramic, CBCT panoramic-section, and CBCT cross-section images) with values measured using the protrusive occlusal record. MATERIALS AND METHODS. SCGAs were measured in 20 patients on a semi-adjustable articulator using the protrusive interocclusal record. Panoramic and CBCT images were obtained. SCGAs were measured on CBCT images in panoramic and cross sections. In all of the radiographic images, SCGAs were measured using the Frankfort horizontal reference line and the mean curvature line. The most-superior and most-inferior points of the curvatures were identified to determine the mean curvature line. Each measurement was performed twice by two operators independently. The data were analyzed by the t-test, Pearson's correlation test, and Cronbach's ${\alpha}$ using SPSS (${\alpha}=.05$). RESULTS. The mean right and left SCGAs were as follows: protrusive occlusal record (30.1 and 30.2 degrees, respectively), panoramic (38.9 and 38.7 degrees), CBCT panoramic sections (35.4 and 36.8 degrees), and CBCT cross sections (35.3 and 36.1 degrees). The SCGAs differed significantly among the groups. The Pearson coefficients for the correlations with the protrusive occlusal record measurements on the left and right sides were as follows: panoramic (0.834 and 0.791, respectively), CBCT panoramic-section (0.918 and 0.837), and CBCT cross-section (0.918 and 0.845) images. CONCLUSION. Strong correlations were found between SCGAs obtained using radiographic images and the protrusive occlusal record.

Retrospective clinical and radiographic evaluation of restored endodontically treated teeth

  • Paula Pontes Garcia ;Aline Cappoani ;Ricardo Susin Schelbauer ;Gisele Maria Correr ;Carla Castiglia Gonzaga
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.49.1-49.11
    • /
    • 2020
  • Objectives: The aim of this study was to perform a clinical and radiographic analysis of endodontically treated teeth (ETT) restored with cast metal posts (CMPs) or prefabricated glass fiber posts (GFPs) and crowns. Materials and Methods: Fifty ETT were restored with 25 CMPs and 25 GFPs at a private dental clinic between 2001 and 2016. The restorations consisted of 12 all-ceramic crowns, 31 metal-ceramic crowns, and 7 composite resin crowns. Demographic data, type of teeth, type of post-and-core system, time of placement, crown restorations, the number of proximal contacts, the type of antagonist, and reports of any complications after post-and-core placement were recorded for each patient. Assessments were performed at baseline (radiographic) and follow-up (radiographic and clinical). Data were analyzed by the McNemar test, the Pearson χ2 test, and Kaplan-Meier survival curves (α = 0.05). The mean follow-up was 67.6 months. Results: No significant difference was observed for any of the radiographic parameters when the baseline and final radiographs were compared. In the clinical evaluation, anatomical form (p = 0.009) and occlusion (p = 0.001) showed significant differences according to the type of crown restoration; specifically, metal-ceramic and all-ceramic crowns outperformed composite resin crowns. Conclusions: CMPs and GFPs showed favorable results for restoring ETT after 6 years of follow-up. All-ceramic and metal-ceramic crowns showed higher survival rates and better clinical outcomes.

Porcine-derived soft block bone substitutes for the treatment of severe class II furcation-involved mandibular molars: a prospective controlled follow-up study

  • Jae-Hong Lee;Ji-Hoo Han;Seong-Nyum Jeong
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.6
    • /
    • pp.406-416
    • /
    • 2023
  • Purpose: No evidence exists regarding the advantages of periodontal regeneration treatment for furcation defects using soft block bone substitutes. Therefore, this randomized controlled trial aimed to assess the clinical and radiographic outcomes of regenerative therapy using porcine-derived soft block bone substitutes (DPBM-C, test group) compared with porcine-derived particulate bone substitutes (DPBM, control group) for the treatment of severe class II furcation defects in the mandibular molar regions. Methods: Thirty-five enrolled patients (test group, n=17; control group, n=18) were available for a 12-month follow-up assessment. Clinical (probing pocket depth [PPD] and clinical attachment level [CAL]) and radiographic (vertical furcation defect; VFD) parameters were evaluated at baseline and 6 and 12 months after regenerative treatment. Early postoperative discomfort (severity and duration of pain and swelling) and wound healing outcomes (dehiscence, suppuration, abscess formation, and swelling) were also assessed 2 weeks after surgery. Results: For both treatment modalities, significant improvements in PPD, CAL, and VFD were found in the test group (PPD reduction of 4.1±3.0 mm, CAL gain of 4.4±2.9 mm, and VFD reduction of 4.1±2.5 mm) and control group (PPD reduction of 2.7±2.0 mm, CAL gain of 2.0±2.8 mm, and VFD reduction of 2.4±2.5 mm) 12 months after the regenerative treatment of furcation defects (P<0.05). However, no statistically significant differences were found in any of the measured clinical and radiographic parameters, and no significant differences were observed in any early postoperative discomfort and wound healing outcomes between the 2 groups. Conclusions: Similar to DPBM, DPBM-C showed favorable clinical and radiographic outcomes for periodontal regeneration of severe class II furcation defects in a 12-month follow-up period.

In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

  • Tampelini, Fernanda Garcia;Coelho, Marcelo Santos;de Azevedo Rios, Marcos;Fontana, Carlos Eduardo;Rocha, Daniel Guimaraes Pedro;Pinheiro, Sergio Luiz;da Silveira Bueno, Carlos Eduardo
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.200-205
    • /
    • 2017
  • Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a ${\times}25$ magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.

Comparative Reliability of Nondestructive Testing for Weld: Water Wall Tube in Thermal Power Plant Boiler Case Study (용접부 비파괴 검사의 신뢰성 비교: 화력 발전소의 보일러 수냉벽 배관 사례연구)

  • Choi, Chang Deok;Lim, Ik Sung
    • Journal of Applied Reliability
    • /
    • v.18 no.3
    • /
    • pp.240-249
    • /
    • 2018
  • Purpose: The purpose of this research is to find which technique, between the PAUT (Phased array ultrasonic test) that has been used widely in practice and RT (Radiographic test) that was used widely in the past, has the higher reliability as a non-destructive testing of welding points in water wall tubes. Methods: To evaluated the reliability of non-destructive testing, eleven test pieces that were fabricated intentionally, which have the most frequently occurred defect types in water wall tubes and then both the PAUT and RT were performed on those eleven test pieces to compare their reliability. Results: The differences of type of defect, length are occurred due to the characteristics of nondestructive testing. The RT could not detect the lack of fusion defect type in specimen #4 and #8 while PAUT could not detect the lateral crack and 1 mm size small porosity in specimen #11. Conclusion: It is concluded that applying both the RT and PAUT result the best reliability rather than applying only one test method, if it is possible, in nondestructive testing of weld water wall tube in thermal power plant boiler case.

Automatic Safety Inspection Technique for Ammunition Fuzes using Radiographic Images (방사선 영상을 이용한 탄약신관 안전상태 자동인식기술 개발)

  • An, Ji Yeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.283-292
    • /
    • 2015
  • This paper presents the development of the automatic safety inspection technique for the ammunition fuzes using radiography images. The technique inspects 49-ammunition fuze by detecting the X-ray or neutron radiographic images to check whether the fuze is unintendedly armed or/and some major assembled parts are at right place. To execute the program, we loads the image(s) for under test. After reading images, the program conducts a series of pre-image processing, and then starts inspecting input images by using the detection algorithms which are designed distinctively for each fuze. After completing the detection process, the program displays the final result of the fuze status: "safety or danger." Through this program, we can cut off the fuzes which have any doubt about safety, and can only provide absolutely safe fuzes, compared with the current naked eye inspection method.

A Special Pre-Service-Inspection Using Radiographic Testing(RT) for Brazing Fitting Uused in Aircraft Hydraulic System

  • Kim, Gyu-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.3
    • /
    • pp.271-281
    • /
    • 2010
  • Brazing fitting which is one of the aircraft hydraulic power system components is widely used for saving weight and achieving higher reliability. Any inherent defects or damage of fitting can cause system failure and/or physical damage of human body due to highly pressurized fluid. Radiographic testing(RT) technique and additional micro-structure investigation on cut-away surfaces have been accomplished to find out some defect-like-inhomogeneity in the fittings. The radiography results showed that some defect-like-inhomogeneity existed inside body. Additional micro-structure investigation on cut-away surface reveals that the inhomogeneity is due to internal voids. In this study, it can be is said that RT technique can be a useful tool for field acceptance test of hydraulic brazing fitting in short time.

Reliability and Validity of the Manual Measurement Method for Patellar Height (무릎뼈 높이에 대한 도수측정방법의 신뢰도와 타당도)

  • Kim, Moon-Hwan;Yun, Sung-Joon;Weon, Jong-Hyuck
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.54-61
    • /
    • 2013
  • This study was to determine the reliability and validity of manual measurements of patellar height to standard radiographic measurements in 30 knees of 15 subjects. Patellar height was measured using manual and radiographic methods. The manual measurements were performed by two examiners using digital vernier calipers with the subject sitting and the knees in $30^{\circ}$ of flexion. The radiographic measurements were performed in the same position. The reliability of the manual measurements was assessed by means of intraclass correlation coefficients [ICC(3,1)], and the validity was investigated using the Pearson's product-moment correlation coefficient and an independent t-test. The intra- and inter-rater reliabilities of the manual measurement of patellar height were excellent (ICC=.86 and .88 respectively). The validity of patellar height measured manually compared to the radiographic method was good (Pearson's r=.69). In conclusion, the manual method is an objective, qualitative measurement of patella height.

Evaluation of the clinical and radiographic effectiveness of treating peri-implant bone defects with a new biphasic calcium phosphate bone graft: a prospective, multicenter randomized controlled trial

  • Jae-Hong Lee;Hyun-wook An;Jae-Seung Im;Woo-Joo Kim;Dong-Won Lee ;Jeong-Ho Yun
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.4
    • /
    • pp.306-317
    • /
    • 2023
  • Purpose: Biphasic calcium phosphate (BCP), a widely used biomaterial for bone regeneration, contains synthetic hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP), the ratio of which can be adjusted to modulate the rate of degradation. The aim of this study was to evaluate the clinical and radiographic benefits of reconstructing peri-implant bone defects with a newly developed BCP consisting of 60% β-TCP and 40% HA compared to demineralized bovine bone mineral (DBBM). Methods: This prospective, multicenter, parallel, single-blind randomized controlled trial was conducted at the periodontology departments of 3 different dental hospitals. Changes in clinical (defect width and height) and radiographic (augmented horizontal bone thickness) parameters were measured between implant surgery with guided bone regeneration (GBR) and re-entry surgery. Postoperative discomfort (severity and duration of pain and swelling) and early soft-tissue wound healing (dehiscence and inflammation) were also assessed. Data were compared between the BCP (test) and DBBM (control) groups using the independent t-test and the χ2 test. Results: Of the 53 cases included, 27 were in the test group and 26 were in the control group. After a healing period of 18 weeks, the full and mean resolution of buccal dehiscence defects were 59.3% (n=16) and 71.3% in the test group and 42.3% (n=11) and 57.9% in the control group, respectively. There were no significant differences between the groups in terms of the change in mean horizontal bone augmentation (test group: -0.50±0.66 mm vs. control groups: -0.66±0.83 mm, P=0.133), postoperative discomfort, or early wound healing. No adverse or fatal complications occurred in either group. Conclusions: The GBR procedure with the newly developed BCP showed favorable clinical, radiographic, postoperative discomfort-related, and early wound healing outcomes for peri-implant dehiscence defects that were similar to those for DBBM.

Comparative study of two collagen membranes for guided tissue regeneration therapy in periodontal intrabony defects: a randomized clinical trial

  • Chung, Young-Mi;Lee, Jue-Yeon;Jeong, Seong-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.4
    • /
    • pp.194-200
    • /
    • 2014
  • Purpose: The purpose of this study was to assess and compare the clinical and radiographic outcomes of guided tissue regeneration therapy for human periodontal intrabony defects using two different collagen membranes: a porous nonchemical cross-linking collagen membrane (NC) and a bilayer collagen membrane (BC). Methods: Thirty subjects were randomly assigned and divided into the following 3 groups: a test group (NC+BM), in which a NC was used with xenograft bone mineral (BM), a positive control group (BC+BM), in which a BC was used with xenograft BM, and a negative control group (BM), in which only xenograft BM was used. The following clinical measurements were taken at baseline and 3 months after surgery: plaque index, gingival index, probing pocket depth, gingival recession, and clinical attachment level. Radiographic analysis was performed at baseline, 1 week and 3 months after surgery. Results: Membrane exposure was not observed in any cases. Significant probing depth reduction, attachment-level gain and bone fill were observed for both test and control groups compared to baseline at 3 months after surgery (P<0.05). However, there were no statistically significant differences in clinical improvement and radiographic bone fill between treatment protocols (P>0.05). Conclusions: Within the limitations of this study, the results suggest that both NC and BC were comparable in terms of clinical and radiographic outcomes for the treatment of periodontal intrabony defects in human subjects.