PURPOSE. This study compared the SCGAs measured in three types of radiographic images (panoramic, CBCT panoramic-section, and CBCT cross-section images) with values measured using the protrusive occlusal record. MATERIALS AND METHODS. SCGAs were measured in 20 patients on a semi-adjustable articulator using the protrusive interocclusal record. Panoramic and CBCT images were obtained. SCGAs were measured on CBCT images in panoramic and cross sections. In all of the radiographic images, SCGAs were measured using the Frankfort horizontal reference line and the mean curvature line. The most-superior and most-inferior points of the curvatures were identified to determine the mean curvature line. Each measurement was performed twice by two operators independently. The data were analyzed by the t-test, Pearson's correlation test, and Cronbach's ${\alpha}$ using SPSS (${\alpha}=.05$). RESULTS. The mean right and left SCGAs were as follows: protrusive occlusal record (30.1 and 30.2 degrees, respectively), panoramic (38.9 and 38.7 degrees), CBCT panoramic sections (35.4 and 36.8 degrees), and CBCT cross sections (35.3 and 36.1 degrees). The SCGAs differed significantly among the groups. The Pearson coefficients for the correlations with the protrusive occlusal record measurements on the left and right sides were as follows: panoramic (0.834 and 0.791, respectively), CBCT panoramic-section (0.918 and 0.837), and CBCT cross-section (0.918 and 0.845) images. CONCLUSION. Strong correlations were found between SCGAs obtained using radiographic images and the protrusive occlusal record.
Sangjin Ahn;Woojin Shin;Yujin Han;Sohwon Bae;Chea-Un Cho;Sooyoung Choi;Jong-Taek Kim
한국임상수의학회지
/
제40권2호
/
pp.119-123
/
2023
Although various imaging evaluation methods have been developed and utilized, thoracic radiography remains essential and is the top priority for diagnosing and managing cardiac diseases. Thoracic radiographic measurements associated with the vertebral heart scale (VHS) and caudal vena cava (CVC) can objectively diagnose cardiac disease in many animals. In particular, VHS measurement is primarily used to evaluate the dimensions of the heart size on thoracic radiographs and can measure cardiomegaly more objectively. Additionally, the value of the CVC compared with the aorta (Ao) and the length of vertebrae (VL) can be used as valuable parameters in right congestive heart failure. To describe the CVC/Ao and CVC/VL ratios in 10 long-tailed gorals (Naemorhedus caudatus) without subjective radiographic evidence of cardiac diseases. The VHS, CVC, Ao, and VL of gorals were measured in the right lateral (RL) view of the thoracic radiographs. In the RL view of 10 gorals, the VHS was 9.31 ± 0.55 vertebrae (v), the CVC/Ao ratio was 0.84 ± 0.13, and the CVC/VL ratio was 0.67 ± 0.09. Additionally, the thoracic morphology of gorals was determined to be intermediate (thoracic depth-to-width ratio, 1.04 ± 0.09, 0.75-1.25). This study confirmed that VHS was significantly correlated with CVC and Ao, and measuring and comparing each value would help diagnose cardiac diseases in gorals. The radiographic measurements in this study will allow veterinarians to diagnose several cardiac diseases in gorals.
Song-In Lee;Han-Joon Lee;Joong-Hyun Song;Kun-Ho Song
한국임상수의학회지
/
제39권6호
/
pp.287-293
/
2022
Radiographic left atrial dimension (RLAD) is a useful measurement to assess left atrial enlargement in dogs. There are studies on the use of RLAD on various breeds of dogs, but no study on a specific breed with myxomatous mitral valve disease (MMVD). This study was conducted to compare RLAD measurements in Maltese dogs with MMVD ACVIM stage B1 and B2, and also to investigate the correlation of RLAD with the LA:Ao ratio. A total of 29 Maltese dogs were the subjects of this study. Each dog was diagnosed with MMVD ACVIM stage B1 or B2 based on physical examination, thoracic radiography, and echocardiography. The vertebral heart size (VHS), RLAD, LVIDDn, and LA:Ao ratio were measured and compared to evaluate the differences. There were significant differences in the RLAD, LVIDDn, and LA:Ao ratio between dogs with MMVD ACVIM stage B1 and those with stage B2. There was a significant correlation between the LA:Ao ratio and both the RLAD and VHS measurements, but the correlation coefficient was higher for RLAD. The RLAD scores exhibited a significant difference between dogs with ACVIM Stage B1 and with those with B2, and these scores had a higher correlation with the LA:Ao ratio measured by echocardiography than with VHS.
The X-ray projection system has long been used for steel-tube inspection and weld monitoring. The thickness of tubes and welded areas is based on the evaluation of radiographic shadow projections. The traditional tangential measurement estimates the distance of border lines of the projected wall shadows of a tube onto a radiographic image detector. The detected image in which although there is a variety of noise may be sectioned into several partitions according to its specific blocks. Imaging noise originates from most of elements of the system, such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc. The tangential projection incorrectness and noise influence on imaging quality. In this paper we first sectionalize the X-ray image on the basis of vertical contrast difference. And next functional and statistic analysis are carried on at each region. Geometrical distance and unsharpness of the edge caused by visual evaluation uncertainties are also discussed.
The present study was performed to compare cranial tibial wedge osteotomy (CTWO) and tibial plateau leveling osteotomy (TPLO) through radiographic evaluation. The experiment was conducted with five cadaver dogs [mean (± SD) weight, 32.9 ± 4.1 kg; mean (± SD) age, 6 ± 2 years; three males and two females] euthanized for reasons unrelated to this study. The cadaver dogs consisted of German Shepherd (n = 3), Belgian Malinois (n = 1), and mixed breed (n = 1). CTWO and TPLO were carried out by the standard surgical method. Radiographic evaluation was performed by comparing several factors, including the flexion and extension angles, the anatomical mechanical axis angle (AMA-angle), tibial length, patellar height measurement using the Labelle-Laurin method, mechanical medial proximal tibial angle (mMPTA), mechanical medial distal tibial angle (mMDTA), and frontal plane alignment (FPA). Both the CTWO and the TPLO groups showed significantly increased flexion angles after surgery. Only the CTWO group had significantly increased extension angle. Although both groups showed significant decreases in the AMA-angle, the mechanical axis moved cranially against the anatomical axis only in the CTWO group. The patellar height was significantly lowered in the CTWO group. No significant differences were found in mMPTA, mMDTA, or FPA. In conclusion, radiographic comparison revealed more changes in CTWO group than in TPLO group.
Jessica Gabriele da Rocha;Isabella Marian Lena;Jessica Lopes Trindade;Gabriela Salatino Liedke;Renata Dornelles Morgental;Carlos Alexandre Souza Bier
Restorative Dentistry and Endodontics
/
제47권3호
/
pp.34.1-34.12
/
2022
Objectives: This study aimed to evaluate the success rate of endodontic treatments performed by undergraduate students and the factors associated with the outcome. Materials and Methods: A follow-up of 3 to 8 years after root canal filling was carried out in 91 patients. At the follow-up visits, medical and dental history questionnaires were applied along with clinical and radiographic examinations. Data collected in the clinical exam included: the presence of pain, swelling, sinus tract, mobility, tenderness to palpation and percussion, periodontal probing profile, and type/quality of coronal restoration. Postoperative and follow-up radiographs were digitalized and analyzed by 2 trained and calibrated examiners to assess periapical healing. The treatment outcome was based on strict clinical and radiographic criteria and classified as success (absence of any clinical and radiographic sign of apical periodontitis) or failure (other combination). Logistic regression was used to investigate the impact of clinical and radiographic variables on endodontic treatment outcomes at a 5% significance level. Results: The success rate of endodontic treatments was 60.7%. The only risk factor significantly associated with failure was the presence of a periapical lesion on the postoperative radiograph (odds ratio, 3.35; 95% confidence interval, 1.17-9.54). Conclusions: The success rate of endodontic treatments performed by undergraduate students was low and was jeopardized by the presence of a periapical lesion on the postoperative radiograph.
Purpose: The purpose of this study was to investigate the validity and reproducibility of a method based on cone-beam computed tomography (CBCT) technology for the visualization and measurement of gingival soft-tissue dimensions. Material and Methods: A total of 66 selected points in soft-tissue of the ex vivo head of an adult pig were investigated in this study. For the measurement of radiographic thickness (RT), wet soft-tissue surfaces were lightly covered with barium sulfate powder using a powder spray. CBCT was taken and DICOM files were assessed for soft-tissue thickness measurement at reference points. A periodontal probe and a rubber stop were used for the measurement of trans-gingival probing thickness (TPT). After flap elevation, actual thickness of soft-tissue (actual thickness, AT) was measured. Correlation analysis and intraclass correlation coefficients analysis (ICC) were performed for AT, TPT, and RT. Results: All variables were distributed normally. Strong significant correlations of AT with RT and TPT values were found. The two ICC values between TPT vs. AT and RT vs. AT differed significantly. Conclusion: Our results indicated that correlation of RT was stronger than that of TPT with AT. We concluded that soft tissue measurement with CBCT could be a reliable method, compared to the trans-gingival probing measurement method.
Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
Imaging Science in Dentistry
/
제43권3호
/
pp.185-190
/
2013
Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
제32권3호
/
pp.230-234
/
2006
Purpose: This study presents radiographic and laboratory analysis and comparison of bone resorption rate of grafted endochondral bone and intramembranous bone on the aspect of height and volumetric change. Patients and Methods: 18 partially edentulous patients who needed alveolar ridge augmentation for implant placement during the years 2002 to 2004 were selected for this study. Group A consisted of 5 males & 3 females who were treated with intraoral(intramembranous) bone and Group B consisted of 8 males & 2 females who were treated with iliac(endochondral) bone. Non-standard periapical X-ray was taken at day 1, 2 month, 4 months, 8 months after the surgery. Resorption rate of grafted bone were measured on these X-rays and compared. Also we calculated volume of grafted bone with models which was fabricated at 1.5 months, 6 months. Results: There was bone resorption in both groups. Group B showed more bone resorption than Group A. In Group A, the resorption rate according to the radiographic measurements was 9.81 %, and resorption rate according to volumetric measurement was 16.5 %. In group B, the resorption rate according to the radiographic measurements was 15.9 %, and resorption rate according to volumetric measurement was 30.6 %. Significant difference is on radiographic resorption of post-op 2, 4, 8 months on two groups (P < 0.05). Also significant difference is on volume resorption on two groups (P < 0.05). Conclusion: We found that more bone resorption occurred with iliac(endochondral) bone and when we use intraoral bone, that bone can maintain their vitality for alveolar ridge augmentation.
이 연구의 목적은 Philips Oralix Pan BC, GE Panelipse, SS White Panorex 1, SS White Panorex 2의 4종의 X-선기기로 촬영한 파노라마 방사선사진상에서 치아장축 각도측정시 오차 허용도에 따른 정확도를 비교 평가하는 것이다. 파노라마 방사선사진 촬영기에서 건조두개골을 (1)정확한 촬영위치, (2) 전방 5㎜이동, (3) 후방 5㎜이동, (4) 전방 10/sup 0/ 기울인 위치, (5) 두개골을 후방 10/sup 0/ 기울인 위치 (6) 두개골을 좌측으로 5㎜ 이동시킨 위치 등 촬영 위치를 6가지로 변화시켜서 임의로 정한 평면 기준선과 협측의 치아장축과의 각도를 측정하여 건조두개골에서의 실측치와 비교하였다. 그 결과는 다음과 같았다. 1.치아장축의 각도 측정결과는 파노라마X-선 촬영기의 종류 및 촬영위치에 관계없이 건조두개골에서의 측정치와 방사선사진상의 측정치의 유의성 있는 상관관계를 갖었다. (p<0.05) 2. 건조두개골에서의 치아장축 각도 측정치를 기준으로 정확한 촬영위치에서 촬영한 파노라마 방사선 사진상의 오차 허용도를 +/-3/sup 0/로 하였을 때, SS White Panorex 1은 측정치의 74%, GE Panelipse는 측정치의 67%, Philips Oralix Pan DC와 SS White panorex 2는 측정치의 64%가 이 오차의 범위내에 있었다. 3. 건조두개골에서의 치아장축 각도 측정치를 기준으로 정확한 촬영위치에서 촬영한 파노라마 방사선 사진상에서의 오차 허용도를 +/-5/sup 0/로 하였을 때, SS White Panorex 1 과 GE Panelipse는 측정치의 89%, Philips Oralix Pan DC는 측정치의 85%, SS White Panorex 2 는 측정치의 81% 가 이 오차의 범위내에 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.