• Title/Summary/Keyword: Radiographic Images

Search Result 338, Processing Time 0.034 seconds

A Study of Radiation Incidence Angle in Cervical Vertebra Anteroposterior(AP) Examination by Position (자세에 따른 목뼈 정면 입사각에 대한 연구)

  • Kwak, Jonghyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.101-107
    • /
    • 2015
  • In anteroposterior radiation test for cervical vertebra, it is general that the incidence angle of X-ray is $15^{\circ}$ to $20^{\circ}$ degrees to head regardless of position. So this study suggests appropriate incidence angle of cervical vertebra depended on the position. From 1 January 2013 to 31 December 2013, cervical spine radiographys and magnetic resonance imaging was performed in 107 people who visited P Hospital located in Pusan. Among them, 39 people(men 24, women 15) were below 80 above 20 years old(average age 54 years) with normal cervical lordosis(normal $40^{\circ}{\pm}5^{\circ}$). In erect position, the incidence angle of cervical vertebra is measured from lateral radiographic images. And in supine position, it measured from MRI sagittal images. Results based on gender, the incidence angle of cervical vertebra in erect position was $25.9^{\circ}$ for men, women was $23.1^{\circ}$, showed statistically significant (p<0.05). And the angle in supine was $11.6^{\circ}$ for men, women was $12.6^{\circ}$, showed not statistically significant (p>0.05) An analysis of age group shows, the incidence angle of cervical vertebra in erect position was $24.6^{\circ}$ under 50, and $25.0^{\circ}$ over 50. The angle in supine was $12.0^{\circ}$ under 50, and $11.9^{\circ}$ over 50. And all of them showed not statistically significant (p>0.05). At all ages, the average of incidence angles in erect position were $24.8^{\circ}$, and the angle in supine was $12.0^{\circ}$, showed statistically significant (p<0.05). The cervical vertebra incidence angle for X-ray was $15^{\circ}$ to $20^{\circ}$ degrees to head in general. But, through the results, it is recommended that the angle is $24.8^{\circ}$ in erect and $12.0^{\circ}$ in supine position. It could be shown true anteroposterior(AP) view of cervical vertebra and accurate intervertebral fusion fixing devices.

Biodistribution of Iodine-131-Iodomisonidazole and Imaging of Tumor Hypoxia in Mice bearing CT-26 Adenocarcinoma (CT-26 선암을 접종한 마우스에서 Iodine-131-Iodomisonidazole의 생체분포 및 종양저산소증의 영상화)

  • Kim, Hye-Won;Kim, Chang-Guhn;Yoon, Kwon-Ha;Kim, Hyun-Jeong;Juhng Seon-Kwan;Roh, Byung-Suk;Yang, David J.;Kim, E.Edmund;Lee, Hyun-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.289-297
    • /
    • 1999
  • Purpose: Misonidazole is a radiosensitizer that binds in hypoxic cells. The purpose of this study was to find out the feasibility of I-131-Iodomisonidazole (IMISO) for imaging of tumor hypoxia. Materials and Methods: Tosyl precursor was dissolved in acetonitrile and I-131-NaI was added to synthesize IMISO. Balb/c mice inoculated with CT-26 adenocarcinoma were injected with IMISO. Mice were sacrificed at 1, 2, 4, 24 hr and % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy and MRI, mouse bearing CT-26 adenocarcinoma was administered with IMISO and imaging was performed 4 hr after. Then, mouse body was fixed and microtomized slice was placed on radiographic film for autoradiography Results: %ID/g of tumor was 1.64 (1h), 0.98 (2h), 0.85 (4h) and 0.20 (24h), respectively. At 24h, %ID/g of tumor was higher than that of all other tissues except thyroid. Tumor to muscle ratio increased with time and tumor to blood ratio also increased with time and reached 1.53 at 24 hr. On autoradiogram, tumor was well visualized as an increased activity in central hypoxic area of the tumor which corresponds to the area of high signal intensity on T2-weighted MR image. On scintigraphy, tumor uptake was visualized. Conclusion: This results suggest that IMISO may have a potential for tumor hypoxia imaging in mouse model. However, further study is needed to improve it's localization in tumor tissue and to achieve acceptable images of tumor hypoxia.

  • PDF

A Correlation between Pulmonary Involvement of Acute Febrile Illness with High Incidence during the Fall and C-reactive Protein (가을철 유행하는 급성열성질환의 폐침범과 CRP와의 연관관계)

  • Kim, Go Woon;Lee, Woo Jin;Hong, Won Ki;Lee, Sung Hoa;Lee, Chang Youl;Lee, Myung Goo;Hyun, In Gyu;Jung, Ki Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.2
    • /
    • pp.116-121
    • /
    • 2009
  • Background: Tsutsugamushi, leptospirosis and hemorrhagic fever with renal syndrome (HFRS) are the prevalent diseases among the acute febrile illnesses in Korea. Pulmonary involvement in the patients with these diseases remains poorly recognized in endemic regions, and this is despite reports of recent outbreaks and epidemic episodes. Pulmonary involvement and a higher CRP level as clinical manifestations show a more severe form of infection. The aim of this study is to analyze the correlation of pulmonary involvement and the CRP level in patients with acute febrile illnesses. Methods: We retrospectively reviewed the clinical records of 105 patients who were diagnosed with tsutsugamushi, HFRS and leptospirosis from January 2002 to May 2008 in Chuncheon Sacred Heart Hospital. The radiographic images were retrospectively analyzed by two radiologists. We analyzed the pulmonary complications of the patients with these febrile diseases and we checked the CRP level at admission. Results: The study included 105 patients who were diagnosed with febrile diseases. Of these patients, 32 patients had hantaan, 10 patients had leptospirosis and 63 patients had tsutsugamushi disease. 42 (40%) patients had pulmonary complications, 20 patients had pulmonary edema, 20 patients had pleural effusion and 2 patients had interstitial pneumonitis. The patients with pulmonary involvement showed a more severe form of infection and a higher CRP level than that of those patients without pulmonary involvement (p=0.0073). Conclusion: Pulmonary involvement in patients with acute febrile diseases might be correlated with a higher CRP level. Identification of this factor on admission might provide useful selection criteria for the patients who need early intensive care.

The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System (방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석)

  • Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Nam Taek-keun;Yoon Mi-Sun;Song Ju-Young
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.82-88
    • /
    • 2005
  • In this study, the physical compensator made with the high density material, Cerrobend, and the electronic compensator realized by the movement of a dynamic multileaf collimator were analyzed in order to verify the properness of a design function in the commercial RTP (radiation treatment planning) system, Eclipse. The CT images of a phantom composed of the regions of five different thickness were acquired and the proper compensator which can make homogeneous dose distribution at the reference depth was designed in the RTP. The frame for the casting of Cerrobend compensator was made with a computerized automatic styrofoam cutting device and the Millennium MLC-120 was used for the electronic compensator. All the dose values and isodose distributions were measured with a radiographic EDR2 film. The deviation of a dose distribution was $\pm0.99 cGy\;and\;\pm1.82cGy$ in each case of a Cerrobend compensator and a electronic compensator compared with a $\pm13.93 cGy$ deviation in an open beam condition. Which showed the proper function of the designed compensators in the view point of a homogeneous dose distribution. When the absolute dose value was analyzed, the Cerrobend compensator showed a $+3.83\%$ error and the electronic compensator showed a $-4.37\%$ error in comparison with a dose value which was calculated in the RTP. These errors can be admtted as an reasonable results that approve the accuracy of the compensator design in the RTP considering the error in the process of the manufacturing of the Cerrobend compensator and the limitation of a film in the absolute dosimetry.

  • PDF

Magnetic Resonance Voiding Cystography in the Diagnosis of Vesicoureteral Reflux: Comparative Study with Voiding Cystourethrography (방광요관역류의 진단에 있어서 자기공명 배뇨성 방광조영술의 유용성: 태뇨성 요도방광조영술과의 비교연구)

  • Lee, Sang-Kwon;Chang, Yong-Min;Koo, Ja-Hoon;Ko, Cheol-Woo;Chung, Sung-Kwang;Kim, Tae-Hun;Sohn, Kyung-Sik;Lee, Chang-Hyun;Kim, Young-Hwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.85-93
    • /
    • 2000
  • Purpose: To evaluate the availability of magnetic resonance (MRI voiding cystography for the diagnosis of vesicoureteral reflux (VUR) and to compare the sensitivity of MR voiding cystography (MRVC) with that of radiographic voiding cystourethrography (VCUG) in the detection of VUR. Material and Methods : MRVC was performed upon 20 children referred for investigation of VUR. Either coronal T1-weighted spin-echo or spoiled gradient-echo images were obtained before and after transurethral administration of a mixture of normal saline and gadopentetate dimeglumine, and immediately after voiding. The findings of MRVC were compared with those of VCUG performed within 6 months of MRVC. Results 1 VUR was detected in 23 ureterorenal units f16 VUR's by both methods, five VUR's by VCUG, and two VUR's by MRVC). The sensitivity of VCUG and MRVC in detecting VUR was 91.3% (21/23) and 78.3% (18/23), respectively. MRVC detected renal scarring in 15 out of 17 kidneys with scintigraphically detected renal scarring. Conclusion : Although MRVC is slightly less sensitive than VCUG in the detection of VUR, it can be used for the diagnosis of VUR and renal scarring simultaneouslyl and thus will reduce the radiation hazard.

  • PDF

The effect of PostGraft$^{TM}$ on implants were installed at the tibia of ovariectomized rats (난소절제술한 백서에 식립한 임플란트에 대한 PostGraft$^{TM}$의 경구 투여 효과)

  • Cho, Chun-Il;Kim, Se-Won;Choi, Yu-Sung;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.300-307
    • /
    • 2011
  • Purpose: This study evaluated PostGraft$^{TM}$ which enhances implant stability and bone density. Materials and methods: Forty eight implants were installed at the tibia of ovariectomized rats. The group administrated with PostGraft$^{TM}$ was the experimental group, and the control group was not administrated. Implant stability was evaluated at the $2^{nd}$, $4^{th}$ and $6^{th}$ week by Periotest value, bone mineral density, bone-to-implant contact. These values were analyzed statistically with Mann-Whitney U test (P<.05). Histological analysis was evaluated at the $2^{nd}$, $4^{th}$ and $6^{th}$ week. Results: According to the Periotest$^{(R)}$ measurement, both experimental and control groups showed decrease in values as time elapsed. Greater decrease was observed in the experimental group but there was no significant difference. By examining the radiographic images, both experimental and control groups showed tendency of increase in bone density. Greater increase was seen in the experimental group but there was no significant difference. According to the bone-to-implant contact measurement, both experimental and control groups showed increase in values as time elapsed. Greater increase was seen in the experimental group. At the $2^{nd}$ and $4^{th}$ week, there was no significant difference. But at the $6^{th}$ week, there was significant difference (P<.05). By histological analysis, both experimental and control groups showed increase in bone formation as time elapsed. In addition, greater increase was seen in the experimental group. Conclusion: It could be concluded that the PostGraft$^{TM}$ medicated group showed better results in the bone density and osseointegration.

Measurement of shoulder motion fraction and motion ratio (견관절 운동 분율의 측정)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2006
  • Purpose : This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. Materials and Methods : We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR(computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was $15^{\circ},\;19^{\circ},\;22^{\circ}$ to the cephald for the parallel scapular spine, and the tilting of torso was external oblique $40^{\circ},\;36^{\circ},\;22^{\circ}$ for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age(20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, $90^{\circ}$ and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. Results : While the arm elevation was $90^{\circ}$, the shoulder motion fraction was 1.22(M), 1.70(W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84, and left was 1.57, 1.32. In right dominant arm(78%), $90^{\circ} and Full motion fraction was 1.58, 1.43, in left(22%) 1.82, 1.94. In generation 20, $90^{\circ} and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28, 60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. Conclusion : The criterior of motion fraction was useful reference for clinical dignosis the shoulder instability.

  • PDF

Clinical and Radiological Results of Treating Unstable Distal Radial Fractures with a Domestically Developed Volar Locking Plate That Has the Characteristic of Double-Tiered Subchondral Support (불안정성 원위 요골 골절의 치료에 있어 한국형 이중 연골하지지고정 전방 금속판의 임상적 및 방사선학적 결과)

  • Lee, Chul-Hyung;Jung, Deukhee;An, Chung-Han;Jeong, Uitak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.495-502
    • /
    • 2020
  • Purpose: The aim of this study was to assess the effectiveness of domestically developed volar locking plate which has the concept of double-tiered subchondral support (DSS) in maintaining the reduction after distal radial fracture surgery. Materials and Methods: From July 2017 to December 2018, 54 patients were assessed. Plain radiographs were obtained immediately after surgery and at the last follow-up, and the radiographic parameters were measured in those images: radial length, radial inclination, volar tilt, ulnar variance, and distal dorsal cortical distance. The patients were subdivided into their age, type of fracture, and the position of the plate to evaluate the influence of each factors on the reduction maintenance. Results: Distal dorsal cortical distance in radiographs after the surgery was 5.91 mm (standard deviation, ±1.95 mm) on average. Significant differences in the radial length (p=0.038) and ulnar variance (p=0.001) were observed between immediately after surgery and at the last follow-up. When the parameters were evaluated by dividing the patients into subgroups according to the three specific factors, the ulnar variance showed a significant increase at the last follow-up when the patients were included 65-years-old or older. AO/OTA type C3 fracture, and Soong classification grade 0 plate position (p=0.007, p=0.012, p=0.046, respectively). Conclusion: Using the domestically developed DSS-type volar locking plate, significant reduction after distal radial fracture surgery could be maintained successfully. On the other hand, further study will be needed to determine about the reduction loss of the lunate facet identified in special cases that deal with fractures in elderly patients, unstable AO/OTA type C3 distal radial fractures, and Soong classification grade 0 plate position.