• Title/Summary/Keyword: Radiographers

Search Result 22, Processing Time 0.018 seconds

Radiographers: Responsible Medical Professional or Detached Employee? (방사선사: 전문 의료직인가? 단순 기술직인가?)

  • Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.10
    • /
    • pp.234-240
    • /
    • 2008
  • This article examines the professional status of radiographers in an attempt to answer the question "Radiographers: responsible medical professional or detached employee?" Comparisons are made on the past and present views of radiography with thoughts given into the possible change for the future. It can be clearly seen that the professional rights have been taken away as a result of overwhelming medical dominance but changes are slowly taking to place which are attempting to replace the lost autonomy to place radiography as a profession once again.

The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions

  • Chang, Young Jae;Kim, Ah Na;Oh, In Su;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.162-167
    • /
    • 2014
  • Background: Although a physician may be the nearest to the radiation source during C-arm fluoroscope-guided interventions, the radiographer is also near the fluoroscope. We prospectively investigated the radiation exposure of radiographers relative to their location. Methods: The effective dose (ED) was measured with a digital dosimeter on the radiographers' left chest and the side of the table. We observed the location of the radiographers in each procedure related to the mobile support structure of the fluoroscope (Groups A, M and P). Data about age, height, weight, sex, exposure time, radiation absorbed dose (RAD), and the ED at the radiographer's chest and the side of the table was collected. Results: There were 51 cases for Group A, 116 cases for Group M and 144 cases for Group P. No significant differences were noted in the demographic data such as age, height, weight, and male to female ratio, and exposure time, RAD and ED at the side of the table. Group P had the lowest ED ($0.5{\pm}0.8{\mu}Sv$) of all the groups (Group A, $1.6{\pm}2.3{\mu}Sv$; Group M, $1.3{\pm}1.9{\mu}Sv$; P < 0.001). The ED ratio (ED on the radiographer's chest/ED at the side of the table) of Group A was the highest, and the ED radio of Group P was the lowest of all the groups (Group A, $12.2{\pm}21.5%$; Group M, $5.7{\pm}6.5%$; Group P, $2.5{\pm}6.7%$; P < 0.001). Conclusions: Radiographers can easily reduce their radiation exposure by changing their position. Two steps behind the mobile support structure can effectively decrease the exposure of radiographers by about 80%.

A Survey of the Radiographic Cassettes Disinfection of University Hospitals in Seoul (서울지역 대학병원의 방사선과 카세트 소독에 관한 연구)

  • Kweon, Dae-Cheol;Kim, Moon-Sun;Kim, Dong-Sung;Park, Peom
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.65-70
    • /
    • 2001
  • The purpose of this study is to prevent nosocomial infection in patients through contact of radiographic cassettes. Data were collected from radiographers working in 29 university hospitals in Seoul in February and March 2001. Radiographic cassettes were disinfected daily in 5 hospitals, weekly in 4 hospitals, monthly in 5 hospitals, bimonthly in 1 hospital and once every three months in another hospital. 12 other hospitals do not practice regular disinfections of radiographic cassettes. Gauze soaked in disinfectant solution is used in 7 hospitals while 11 hospitals used cotton and cloth soaked in disinfectant solution to clean the radiographic cassettes. 26 hospitals used 99% alcohol based disinfectant solutions while 3 hospitals used 75% alcohol based disinfectant. 26 hospitals use of intercourse cassettes outpatients and in patients. In 26 hospitals, all patients shared the same set of radiographic cassettes used in the hospitals, or in 26 hospitals, separate sets of radiographic cassettes are used for outpatients and inpatients. Separate sets of cassettes are used for ICU and inpatients in 6 others hospitals. 23 hospitals used the same sets of radiographic cassettes for all their patients. radiographic cassettes are cleaned in wash area in the study room of the radiographic department in 17 hospitals. 12 other hospitals do not have designated cleaning areas for the cassettes. All radiographers practiced hands washing with soap. All 29 hospitals surveyed have infection control committee. However, only 9 out of the 29 hospitals surveyed provided Infection disinfections control education to radiographers. Only 3 hospitals have radiographers sitting in the infection control committee. Infection management education is conducted in 63 hospitals annually, twice a year in 1 hospital and once every 3 months in 2 hospitals.

  • PDF

Convergence factor Influencing Job Satisfaction of Radiographer (방사선사의 직무만족도에 영향을 미치는 융복합요인)

  • Lee, Mi-Hwa
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.357-368
    • /
    • 2015
  • This cross-sectional study was performed to offer radiographer who registered to the Korean Association of Radiographers as a basic material promote job satisfaction and lower job stress. A total of 213 radiographer were surveyed using a self-administered questionnaire. The 105 questionnaires consist of general characteristics, job characteristics, job stress, and job satisfaction. The job satisfaction was categorized into 3 sub-scales; psychological variables, environmental variables, and structural variables. The job stress insufficient job control, interpersonal conflict, job insecurity, organizational system, lack of reward, and occupational climate. Job satisfaction in psychological variables of radiographer was higher in the radiographers who have a high level of education, work in seoul,have a high sense of mission, don't have job leaving attitude, have a lower job insecurity. Job satisfaction in environmental variables of radiographer was higher in the radiographers who get lower salary. Job satisfaction in structural variables of radiographer was higher in the radiographers who have a high sense of mission, don't have job leaving attitude, have a lower organizational system, lack of reward, and occupational climate. Job satisfaction of radiographer was higher in th radiographers who don't have job leaving attitude, have a high sense of mission, have a lower lack of reward, and occupational climate.

A Study on Radiologic Technologist's License System and Primary Pathway Education Curriculum in the United States American : Focused on One Case of College in Texas (미국 방사선사 면허제도와 기본 교육과정에 대한 고찰 : 텍사스주 일개 대학 사례를 중심으로)

  • Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.43 no.1
    • /
    • pp.35-43
    • /
    • 2020
  • The purpose of this study was to study on radiologic technologist's license system and primary pathway education curriculum in the United States American (USA), focused on one case of college in Texas. We were collected and analyzed through class participation at a community college in Tarrant, interviews with professors of radiologic science and clinical radiographers, field trips, an internet search, and literature reviews. As a result, first, the American radiologic technologists license system is composed of fifteen chapters, and the professional education courses for each field are being carried out through three courses of a primary pathway, a post primary pathway and a physician extender. Second, the primary pathway courses consisted the radiography, the radiation therapy, the nuclear medicine, the magnetic resonance imaging, the sonography. Third, the USA had about 30 times more clinical practice time than Korea. In clinical practice, students had done actually examination through X-ray exposure on patients. Last radiographers in the USA was able to perform intravenous injection of radiopharmaceutical agents on patient, so that he could perform rapid examination and efficient manpower operation. This study could be used as basic data for the globalization of radiologic technologists license system in Korea.

A Study on the Setting of Examination Limits for Radiographers in Medical Institutions (의료기관 내 방사선사의 검사 한도 설정에 관한 연구)

  • Jeong-Ho Kim;Gap-Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.401-410
    • /
    • 2023
  • A radiographer is a job in charge of diagnostic imaging equipment, and must contribute to the promotion of public health by suggesting an appropriate level of work. To this end, we intend to present an appropriate level of work through evaluation of human harm according to work, statistical evaluation through questionnaires, and domestic and international trends. In the case of human harm evaluation, considering radiation exposure, 42.6%, shield work, 69.7%, and in the case of magnetic resonance imaging, the maximum length of stay in the examination room should be adjusted to 15 minutes and not exceed 30 times. According to the survey statistics, it was confirmed that the physical and mental burden increased due to the high workload and difficulty compared to working hours. Based on domestic and international trends, it is necessary to adjust the examination standards for domestic radiographers to 36.8% to promote national health through qualitative improvement of radiological examinations. something to do.

Disinfection Efficacy of an Ultraviolet Light on Film Cassettes for Preventive of the Nosocomial Infection (병원감염 예방을 위한 Film Cassette의 자외선 소독 효과)

  • Kweon, Dae-Cheol;Jeon, Yong-Woong;Cho, Am
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2001
  • The bacteria infection on film cassette contact surface was examined at the diagnostic radiology department of the S. hospital. The objective of this study was to assess the contamination level on film cassette contact surface as a predictor of patient prevention from nosocomial infection and for improvement of the hospital environment. The laboratory result was identified non-pathologic bacterial in the five different cassette size of the contact surface. Film cassettes were exposed to ultraviolet light for 1, 2 and 3 minutes. Ultraviolet light disinfection is proven suitable for bacteria. The study concludes that presence of a bacterial infection will prevent a using antiseptic technique on film cassette contact surface. In addition education of nosocomial infection for radiographers will be required. In conclusion, ultraviolet is considered effective to irradate bacteria. Additionally, two minutes are required to sterilize film cassettes.

  • PDF

Imaging Characteristics of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors (비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징)

  • Jeong, Hoi-Woun;Kim, Jung-Min;Jeong, Man-Hee;Im, Eun-Kyung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

X-Rays through the Looking Glass: Mobile Imaging Dosimetry and Image Quality of Suspected COVID-19 Patients

  • Schelleman, Alexandra;Boyd, Chris
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.120-126
    • /
    • 2021
  • Background: This paper aims to evaluate the clinical utility and radiation dosimetry, for the mobile X-ray imaging of patients with known or suspected infectious diseases, through the window of an isolation room. The suitability of this technique for imaging coronavirus disease 2019 (COVID-19) patients is of particular focus here, although it is expected to have equal relevance to many infectious respiratory disease outbreaks. Materials and Methods: Two exposure levels were examined, a "typical" mobile exposure of 100 kVp/1.6 mAs and a "high" exposure of 120 kVp/5 mAs. Exposures of an anthropomorphic phantom were made, with and without a glass window present in the beam. The resultant phantom images were provided to experienced radiographers for image quality evaluation, using a Likert scale to rate the anatomical structure visibility. Results and Discussion: The incident air kerma doubled using the high exposure technique, from 29.47 µGy to 67.82 µGy and scattered radiation inside and outside the room increased. Despite an increase in beam energy, high exposure technique images received higher image quality scores than images acquired using lower exposure settings. Conclusion: Increased scattered radiation was very low and can be further mitigated by ensuring surrounding staff are appropriately distanced from both the patient and X-ray tube. Although an increase in incident air kerma was observed, practical advantages in infection control and personal protective equipment conservation were identified. Sites are encouraged to consider the use of this technique where appropriate, following the completion of standard justification practices.

A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index (Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구)

  • Kim, Jae-In;Lee, Yang-Sub;Jang, Dong-Soo;Jung, Min-Cheol;Bae, Seung-Ho;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF