Decomposition Characteristics of Benzene by Microwave

  • Kim, Dong-Sik;Kim, Jeong-Young;Lee, Dong-Kyu
    • Carbon letters
    • /
    • v.1 no.3_4
    • /
    • pp.143-147
    • /
    • 2001
  • Under the irradiation of radiofrequency wave, the dipole materials vibrate as microwave phase changes. This causes friction between adjacent molecules and enables an unique characteristics of interior heating of the materials. Using this principle, when harmful material pass through anthracite- bed which play a role as a absorber of radiofrequency wave, the material can be easily decomposed by the microwave energy. To remove benzene vapour and other solvents in the process of industry, we examined decomposition of benzene in this manner. It was found that benzene was decomposed to the methane, ethane, propane and butane, etc. during passing through the carbon-bed under the microwave impingement and distribution of methane in the products reached about 85 vol.%. The decomposition rate of benzene was high within 5 minutes from start of reaction. For a lower concentration of benzene gas, general cases in the field of industry, almost complete decomposition of benzene is believed possible and this method is surely expected to be useful for the prevention of air pollution and improvement of ambient condition.

  • PDF

The Characteristics of Sour Gas Decomposition by Microwave (Microwave에 의한 산성가스 분해 특성)

  • Kim, Dong-Sik;Kim, Jae-Surl;Lee, Dong-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1027-1033
    • /
    • 1996
  • Under the Irradiation of the radiofrequency wave, the dipole materials vibrate as microwavic phase change. This causes friction between adjacent molecules and enables an unique charateristics of interior heating of the materials. When dipole gases are adsorbed inside of a solid radiofrequency wave absorber, the gases can be decomposed easily by the microwave energy. The decomposition of sour gases was successfully tested in this manner to develop a sour gas removal process from the combustion flue gas. The standard gas bearing NO and $SO_2$ was passed through and microwave was applied on the calcined char bed as the wave absorber and the gas adsorbent. It was found that more then 95% of NO and 70 % of $SO_2$ was decomposed to the environmentally clean elements during the passage through the 20 gram char bed under the microwave impingement. The surface area and the porosity of char increased because the oxygen radicals produced from decomposed gas attacked carbon in the char capillaries and formed $CO_2$. For a lower concentration of sour gas, general cases in the commercial combustion processes, almost complete decomposion is believed possible and this method is surely expected to be useful for the prevention of air pollutions.

  • PDF

Flexible Engineering Tool for Radiofrequency Parameter Identification of RF-MEMS BAW Filters

  • Mabrouk, Mohamed;Boujemaa, Mohamed-Ali;Choubani, Fethi
    • ETRI Journal
    • /
    • v.38 no.5
    • /
    • pp.988-995
    • /
    • 2016
  • In this paper, we present a new specific and customized interface tool with parameter identification of Modified Butterworth-Van Dyke models for ladder bulk acoustic wave filters. The aforementioned tool is easy to use and flexible because it allows simulations and reengineering to be conducted in an application. A modular design approach is applied to simplify the extension of the proposed tool for different topologies. The proposed tool was validated using measurements from an aluminum-nitride based ladder BAW filter dedicated to the frequency ranges of the Universal Mobile Telecommunications Service and standards and Wideband Code Division Multiple Access.

A Study on the Permeation Properties of Permanent Gases and condensable Vapors through Hexamethyldisiloxane Plasma-Polymerized Membranes (Hexamethyldisiloxane 플라즈마 중합막을 통한 영구기체 및 응축성 증기의 투과특성에 관한 연구)

  • Oh, Sae-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.699-706
    • /
    • 2018
  • The permeation properties of plasma polymer membranes were studied for permanent gases such as He, $H_2$, $O_2$, $N_2$, $CH_4$ and condensable vapors such as $CO_2$, $C_2H_4$, $C_3H_8$. The plasma polymers were prepared by the discharge of microwave or radiofrequency(RF) wave. Hexamethyldisiloxane (HMDS) vapor was used as a monomer for plasma polymerization. In HMDS plasma-polymerized membranes prepared under microwave discharge, the permeability coefficient was dependent of the kinetic molecular diameter of the permeate gases. Additionally the membranes showed higher $O_2/N_2$ permselectivity compared to the plasma polymers from radiofrequency discharge. On the contrary, in the HMDS plasma-polymerized membranes prepared under radiofrequency discharge, the permeability coefficient was dependent of the critical temperature of the permeant gases. The membranes showed high selectivities of $C_2H_4$ and $C_3H_8$ over $N_2$. The permeability coefficient of plasma polymerized membranes prepared under microwave discharge was dependent of the molecular diameter of permeant gases because of high crosslinking density of the membrane. However, the crosslinking density of the plasma polymerized membranes prepared under RF discharge was lower because the energy density of RF wave is weaker than that of microwave. Hence, the permeability of RF plasma polymerized membranes became dependent of the critical temperature rather than molecular diameter of the gases.

Prognostic Value of Inferior Shift of P wave Axis after Catheter Ablation for Longstanding Persistent Atrial Fibrillation based on Dallas Lesion Set Including Anterior Line

  • Shin, Dong Geum;Kim, Tae-Hoon;Jeong, Hyunmin;Kim, Alexander;Uhm, Jae-Sun;Joung, Boyoung;Lee, Moon-Hyoung;Hwang, Chun;Pak, Hui-Nam
    • International Journal of Arrhythmia
    • /
    • 제18권2호
    • /
    • pp.66-76
    • /
    • 2017
  • Background and Objectives: Although an anterior linear ablation is an effective lesion set in radiofrequency catheter ablation (RFCA) for longstanding persistent atrial fibrillation (L-PeAF), its durability for bidirectional block (BDB) is only about 60% at repeat procedure. We hypothesized that changes in electrocardiogram (ECG) may predict an anterior line block state and the clinical outcome of L-PeAF ablation. Subjects and Methods: We studied 304 L-PeAF patients (77% male, $60{\pm}10yrs$), who consistently underwent RFCA Dallas lesion set (circumferential pulmonary vein isolation, posterior box lesion, and anterior line) protocol with subsequent comparison of pre-procedural and post-procedural P wave axes, and one year follow-up (n=205) sinus rhythm (SR) ECGs. Results: 1. P wave axis shifted inferiorly at immediate post-procedure (p<0.001), and was independently correlated with BDB of anterior line (${\ss}=10.4$, 95% confidence interval [CI] 2.79-17.94, p=0.008). 2. The degree of post-procedural inferior shift of P wave axis did not reflect clinical recurrence within one-year (n=205, p=0.923), potentially due to conduction recovery of an anterior line. However, among 160 patients without clinical recurrence within one-year, P wave axis at one-year ECG was independently associated with very late recurrence of AF after one-year (n=160, hazard ratio [HR] 0.98; 95% CI 0.97-0.99, p=0.001), during $45.6{\pm}16.7$ months of follow-up. 3. Among 22 patients who underwent repeat procedures, P wave axis shift was more significant in patients with maintained BDB of an anterior line than in those without (p=0.015). Conclusion: An inferior shift of P wave axis reflects the achievement and the maintenance of an anterior line BDB, and is associated with better long-term clinical outcome after catheter ablation for L-PeAF based on Dallas lesion set.

A Study For Optimizing Input Waveforms In Radiofrequency Liver Tumor Ablation Using Finite Element Analysis (유한 요소 해석을 이용한 고주파 간 종양 절제술의 입력 파형 최적화를 위한 연구)

  • Lim, Do-Hyung;NamGung, Bum-Seok;Lee, Tae-Woo;Choi, Jin-Seung;Tack, Gye-Rae;Kim, Han-Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.235-243
    • /
    • 2007
  • Hepatocellular carcinoma is significant worldwide public health problem with an estimated annually mortality of 1,000,000 people. Radiofrequency (RF) ablation is an interventional technique that in recent years has come to be used for treatment of the hepatocellualr carcinoma, by destructing tumor tissues in high temperatures. Numerous studies have been attempted to prove excellence of RF ablation and to improve its efficiency by various methods. However, the attempts are sometimes paradox to advantages of a minimum invasive characteristic and an operative simplicity in RF ablation. The aim of the current study is, therefore, to suggest an improved RF ablation technique by identifying an optimum RF pattern, which is one of important factors capable of controlling the extent of high temperature region in lossless of the advantages of RF ablation. Three-dimensional finite element (FE) model was developed and validated comparing with the results reported by literature. Four representative Rf patterns (sine, square, exponential, and simulated RF waves), which were corresponding to currents fed during simulated RF ablation, were investigated. Following parameters for each RF pattern were analyzed to identify which is the most optimum in eliminating effectively tumor tissues. 1) maximum temperature, 2) a degree of alteration of maximum temperature in a constant time range (30-40 second), 3) a domain of temperature over $47^{\circ}C$ isothermal temperature (IT), and 4) a domain inducing over 63% cell damage. Here, heat transfer characteristics within the tissues were determined by Bioheat Governing Equation. Developed FE model showed 90-95% accuracy approximately in prediction of maximum temperature and domain of interests achieved during RF ablation. Maximum temperatures for sine, square, exponential, and simulated RF waves were $69.0^{\circ}C,\;66.9^{\circ}C,\;65.4^{\circ}C,\;and\;51.8^{\circ}C$, respectively. While the maximum temperatures were decreased in the constant time range, average time intervals for sine, square, exponential, and simulated RE waves were $0.49{\pm}0.14,\;1.00{\pm}0.00,\;1.65{\pm}0.02,\;and\;1.66{\pm}0.02$ seconds, respectively. Average magnitudes of the decreased maximum temperatures in the time range were $0.45{\pm}0.15^{\circ}C$ for sine wave, $1.93{\pm}0.02^{\circ}C$ for square wave, $2.94{\pm}0.05^{\circ}C$ for exponential wave, and $1.53{\pm}0.06^{\circ}C$ for simulated RF wave. Volumes of temperature domain over $47^{\circ}C$ IT for sine, square, exponential, and simulated RF waves were 1480mm3, 1440mm3, 1380mm3, and 395mm3, respectively. Volumes inducing over 63% cell damage for sine, square, exponential, and simulated RF waves were 114mm3, 62mm3, 17mm3, and 0mm3, respectively. These results support that applying sine wave during RF ablation may be generally the most optimum in destructing effectively tumor tissues, compared with other RF patterns.

A Review on the RF Coil Designs and Trends for Ultra High Field Magnetic Resonance Imaging

  • Hernandez, Daniel;Kim, Kyoung-Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.95-122
    • /
    • 2020
  • In this article, we evaluated the performance of radiofrequency (RF) coils in terms of the signal-to-noise ratio (S/N) and homogeneity of magnetic resonance images when used for ultrahigh-frequency (UHF) 7T magnetic resonance imaging (MRI). High-quality MRI can be obtained when these two basic requirements are met. However, because of the dielectric effect, 7T magnetic resonance imaging still produces essentially a non-uniform magnetic flux (|B1|) density distribution. In general, heterogeneous and homogeneous RF coils may be designed using electromagnetic (EM) modeling. Heterogeneous coils, which are surface coils, are used in consideration of scalability in the |B1| region with a high S/N as multichannel loop coils rather than selecting a single loop. Loop coils are considered state of the art for their simplicity yet effective |B1|-field distribution and intensity. In addition, combining multiple loop coils allows phase arrays (PA). PA coils have gained great interest for use in receiving signals because of parallel imaging (PI) techniques, such as sensitivity encoding (SENSE) and generalized autocalibrating partial parallel acquisition (GRAPPA), which drastically reduce the acquisition time. With the introduction of a parallel transmit coil (pTx) system, a form of transceiver loop arrays has also been proposed. In this article, we discussed the applications and proposed designs of loop coils. RF homogeneous coils for volume imaging include Alderman-Grant resonators, birdcage coils, saddle coils, traveling wave coils, transmission line arrays, composite right-/left-handed arrays, and fusion coils. In this article, we also discussed the basic operation, design, and applications of these coils.

The Expression changes of AMPK, ERK-1/2, and p38 protein associated with Exercise in the Mouse hippocampus exposed to Radiofrequency Radiation (전자파(電磁波)에 노출된 생쥐의 해마에서 운동이 AMPK, ERK-1/2, p38 단백 발현 변화에 미치는 생체 영향)

  • Lee, Min-Sun;Park, Oak Jin;Kim, Hyun Taeg;Kim, Myeung Ju
    • Journal of Digital Convergence
    • /
    • v.18 no.3
    • /
    • pp.267-273
    • /
    • 2020
  • To determine the biological effects of exercise on hippocampus in mice brain exposed to radiofrequency radiaton (RF), the expression of AMPKα, p-AMPKα, ERK1/2, p-ERK1/2, p38, and p-p38 protein in the mouse exposed to RF were investigated in the hippocampal tissues, Western blot method was used to compare the protein expression levels for each molecule. Significant increases in protein expression of individual and phosphorylated molecules were observed in the spontaneous exercise group, and the expression of these molecules was notably decreased in the RF exposure and spontaneous exercise group. This study shows that neuroplasticity can be increased by exercise in hippocampus that is responsible for memory, but memory and cognitive function may be affected by exposure to RF. We may expect clinically interesting results on dementia or Alzheimer disease if we proceed further investigation on the effect of RF.

Prevalence and Characteristics of Atrial Tachycardia From Noncoronary Aortic Cusp During Atrial Fibrillation Catheter Ablation

  • Myung-Jin Cha;Jun Kim;Yoon Jung Park;Min Soo Cho;Hyoung-Seob Park;Soonil Kwon;Young Soo Lee;Jinhee Ahn;Hyung-Oh Choi;Jong-Sung Park;YouMi Hwang;Jin Hee Choi;Ki-Won Hwang;Yoo-Ri Kim;Seongwook Han;Seil Oh;Gi-Byoung Nam;Kee-Joon Choi;Hui-Nam Pak
    • Korean Circulation Journal
    • /
    • v.52 no.7
    • /
    • pp.513-526
    • /
    • 2022
  • Background and Objectives: Atrial tachycardias (ATs) from noncoronary aortic cusp (NCC) uncovered after radiofrequency ablation for atrial fibrillation (AF) are rarely reported. This study was conducted to investigate the prevalence and clinical characteristics of NCC ATs detected during AF ablation and compare their characteristics with de novo NCC ATs without AF. Methods: Consecutive patients who underwent radiofrequency catheter ablation for AF were reviewed from the multicenter AF ablation registry of 11 tertiary hospitals. The clinical and electrophysiological characteristics of NCC AT newly detected during AF ablation were compared with its comparators (de novo NCC AT ablation cases without AF). Results: Among 10,178 AF cases, including 1,301 redo ablation cases, 8 (0.08%) NCC AT cases were discovered after pulmonary vein isolation (PVI; 0.07% in first ablation and 0.15% in redo ablation cases). All ATs were reproducibly inducible spontaneously or with programmed atrial stimulation without isoproterenol infusion. The P-wave morphological features of tachycardia were variable depending on the case, and most cases exhibited 1:1 atrioventricular conduction. AF recurrence rate after PVI and NCC AT successful ablation was 12.5% (1 of 8). Tachycardia cycle length was shorter than that of 17 de novo ATs from NCC (303 versus 378, p=0.012). No AV block occurred during and after successful AT ablation. Conclusions: Uncommon NCC ATs (0.08% in AF ablation cases) uncovered after PVI, showing different characteristics compared to de-novo NCC ATs, should be suspected irrespective of P-wave morphologies when AT shows broad propagation from the anterior interatrial septum.

Assessment for Ingredients and Amount of Radiofrequency Electromagnetic Field Exposure for Indoor Environment in an Institution for the Aged of Downtown (도심지역 노인복지시설 실내 환경에 대한 RF 전자파 노출량의 정성.정량 평가에 관한 연구)

  • Choi, Jung-Hun;Kim, Nam;Hong, Seung-Cheol;Kim, Yoon-Shin;Choi, Sung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.268-274
    • /
    • 2006
  • In this study in order to evaluate the growth of RF propagation exposure rate generated according to the enhancement of its use, it is proposed for the ground to be able to examine and to contemplate the correlation between the human health and RF propagation exposure rate by measuring and analyzing the RF exposure source and exposure rate in an indoor environment. As a result of research, it is analyzed that the main exposure source of critically making effect in indoor environment is the frequency hand if radio broadcasting, mobile communication, wireless LAN, digital broadcasting, home appliance, etc., including the TV broadcasting. Among these, it is shown that the TV broadcasting and mobile communication band are the highest. And it is the concluded that RF exposure rate of the environmental sensitive equipment, like an institution for the aged, has lower possibility to exceed the human RF protection criteria by this evaluation.