• Title/Summary/Keyword: Radioactivity measurement

Search Result 131, Processing Time 0.023 seconds

Simulation of Counting Efficiencies of Portable NaI Detector for Rapid Screening of Internal Exposure in Radiation Emergencies (방사선비상시 내부피폭 신속 분류를 위한 휴대용 NaI 검출기의 계측효율 전산모사)

  • Ha, Wi-Ho;Yoo, Jaeryong;Yoon, Seokwon;Pak, Min Jung;Kim, Jong Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.211-215
    • /
    • 2015
  • In case of radiation emergencies, radioactive materials released into environments can cause internal exposure of members of the public. Even though whole body counters are widely used for direct measurement of internally deposited radionuclides, those are not likely to be used at the field to rapidly screen internal exposure. In this study, we estimated the counting efficiencies of portable NaI detector for different size BOMAB phantoms using Monte Carlo transport code to apply handheld gamma spectrometers for rapid screening of internal exposure following radiological accidents. As a result of comparison for two counting geometries, counting efficiencies for sitting model were about 1.1 times higher than those for standing model. We found, however, that differences of counting efficiencies according to different size are higher than those according to counting geometry. Therefore, we concluded that when we assess internal exposure of small size people compared to the reference male, the body size should be considered to estimate more accurate radioactivity in the human body because counting efficiencies of 4-year old BOMAB phantom were about 2.4~3.1 times higher than those of reference male BOMAB phantom.

Research on Measurement Condition Establishment of a Liquid Scintillation Counter System (액체섬광계수기 장비의 계측조건 확립에 관한 연구)

  • Park, Eung-Seop;Han, Sang-Jun;Lee, Seung-Jin;Kim, Hee-Gang;Lee, Na-Young;Mun, Ji-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.155-164
    • /
    • 2006
  • It is judged that there could be certainty in every process of analyzing environmental samples using Liquid Scintillation Counter. Therefore, this study focuses on quantitative evaluation on uncertainty in an effort to analyze comparatively accurately environmental samples. For this, after parameters which can have an effect on uncertainty was derived, the evaluation on each parameter was tamed out. The results of analysis of each parameter showed that the effect according to the weight difference of Teflon vial did not appear, and that standard deviations of SQP(E) averages reached saturation point at $75{\sim}90$ sec at the result of making increases step by step the irradiation time of External standard, and that values measured by repeat method produces good results compared with replicate. Also, conclusion was derived that analysis on sample after it is left in cold and dark room at least above 1,000 minutes have to be carried out, and the result of carrying out verification on results measured as well as equipment itself using radioactivity-error-analysis and chi-square test, resonable result was derived.

Measurement of Uptake Rates of Internal Organs Including Thyroid Gland and Daily Urinary Excretion Rates for Adult Korean Males (한국남자 성인을 대상으로 한 방사성옥소($^{131}I$)의 갑상선 및 각 장기별 잔류율과 소변 일일배설률 측정)

  • Kim, Jung-Hoon;Kim, Hee-Geun;Whang, Joo-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.2
    • /
    • pp.45-50
    • /
    • 2007
  • In this study, uptake rates of internal organs and daily urinary excretion rates were measured to get more reliable estimation results for Korean. Radioactive iodine($^{131}I$) of $100{\mu}Ci$ was administered by ingestion to 28 adult males for the experiment and then the radioactivity in thyroid gland, liver, stomach, small intestine, kidneys, and urine was measured after time intervals of 2, 4, 6 and 24 hours. Uptake rates of each organ and daily urinary excretion rates were calculated on the basis of these experimental results. As a result, uptake rates of 19.70% for thyroid and daily urinary excretion rates of 71.12%, on the average, were indicated. The maximum of uptake rates and daily urinary excretion rates were recorded after 2 hours of administration of $^{131}I$, but those rates were decreased gradually later. It was also found that uptake rates were the highest in stomach, followed by the left kidney, liver, small intestine and right kidney except for thyroid gland. In this experiment, the calculated uptake change rate in thyroid gland after 24 hours of administration of $^{131}I$ was different from that of ICRP-54/67(30%) and ICRP-78(25%). Thus, it is necessary to apply more reliable approach, reflecting the characteristic of Korean physiology and to obtain the basic data of results using this approach for calculation of the internal adsorbed dose. In the future, this approach can be helpful for the internal dose assessment of radiation workers in a nuclear power plant or in a hospital.

Delivery of Ti Plasmid into Nicotiana sanderae Protoplasts via Liposomes (Liposome을 이용한 Ti Plasmid의 꽃담배 원형질체내 도입)

  • Lim, Myung-Ho;Jeong, Jae-Dong;Kim, In-Soo
    • Applied Biological Chemistry
    • /
    • v.37 no.5
    • /
    • pp.343-348
    • /
    • 1994
  • Ti plasmid of A. tumefaciens was labeled with $^3H-thymidine$, purified and encapsulated into phosphatidylserine (PS) and PS-cholesterol (Chol; 1 : 1 molar ratio) liposomes by lyophilization-rehydration method. PS was supplemented with 1 mole percent octadecyl rhodamine B for fluorometric measurement of PS. Liposomes entrapping $^3H-Ti plasmid$ were fused with Nicotiana sanderae protoplasts by treating with 5 mM $CaCl_2$ and 10% PEG. The fusion was evidenced by fluorescence microscopic technique. The amounts of Ti plasmid and PS associated with protoplasts were assayed by the radioactivity of $^3H-Ti plasmid$ and by the fluorescence of rhodamine B. About 7.9% of the PS liposome and 7.2% of PS-Chol liposome were fused with protoplasts. During the fusion process, about 30% of the liposomal contents of PS-Chol liposome was leaked, in contrast to about 60% leakage of its contents in PS liposome. Accounting the number of liposomes fused with protoplasts together with the encapsulation efficiency and the leakage of liposomal contents, it was calculated that ca. 1,700 Ti plasmid was transfered into one protoplast by the present method. This result may indicates that the present method transfers enough Ti plasmid into plant protoplast to elicit genetic transformation of plants.

  • PDF

Marinelli Beaker Measurement and Self Absorption Correction and Application for Various Environmental Samples in Monte Carlo Simulation (몬테카를로 시뮬레이션에서의 다양한 환경 샘플에 대한 Marinelli 비이커 측정 및 자기 흡수 보정과 적용)

  • Jang, Eun-Sung;Gim, Yang-Soo;Lee, Sun-Young
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.605-611
    • /
    • 2017
  • The structure of the actual detector was computed using the code of the PENELOPE. Using the standard mixed sources (450, 1,000 ml), compare the effectiveness of each energy according to various densities and height of the PENELOPE computer simulation, and calculate the effectiveness of the various environmental specimens and apply them to various environmental specimens to determine the lower limit. The values obtained by the obtained value were obtained by applying the obtained efficiency to the actual environmental specimens and obtaining the lower limit values. The density correction factor is 1.155 g of the density correction factor of $0.4g/cm^3$ (59.54keV), 1.153 (661 keV), $1.06g/cm^3$ 1.064 (1,836.04keV), 1.03, and 1.033. It was confirmed that the radioactivity concentration of environmental samples decreased as the amount of specimen was measured increases, and the MDA value decreased as time measured increases.

Photostimulated Luminescence-Thermoluminescence Application to Detection of Irradiated White Ginseng Powder (방사선 조사 백삼분말의 PSL-TL 다중검지법)

  • Chung, Hyung-Wook;Delincee, Henry;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.265-270
    • /
    • 2000
  • White ginseng powder, permitted to be irradiated in Korea for the purpose of microbial decontamination, was treated with electron beam at doses of $0{\sim}15\;kGy$ for a detection trial whether it is irradiated or not by measuring photostimulated luminescence for whole samples first and then (TL) for the mineral adhering to the samples. PSL values were less than threshold value (700, $T_{1}$) and were negative for nonirradiated samples but more than 5000 $(T_2)$ and were positive for irradiated ones. After PSL measurement mineral was separated from the whole samples using density separation. Mineral of nonirradiated samples was characterized by glow curves which have low intensity and were situated at the high temperature region (about $300^{\circ}C$) by the low level of natural radioactivity. Glow curves of minerals for all irradiated samples were observed at about $200^{\circ}C$. TL ratio by normalization was 0.01 for nonirradiated sample and more than 0.78 for irradiated samples, and it was possible to detect whether white ginseng powders were irradiated or not.

  • PDF

MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil (지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가)

  • Lee, Jun-Ho;Kim, Bong-Gi;Lee, Dong Myung;Byun, Jong-In
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • The detection performances of the NaI(Tl), $LaBr_3$(Ce) and $CeBr_3$ scintillation detectors, which can be used to rapidly evaluate the major artificial radionuclides deposited on the soil surface in a nuclear accident or radiological emergency, were compared. Detection performance was assessed by calculating the minimum detectable activity (MDA). The detection efficiency of each detector for artificial radionuclides was semi-empirically determined using mathematical modelling and point-like sources having certified radioactivity. The background gamma-ray energy spectrum for MDA evaluation was obtained from relatively wide and flat grassland, and the MDA values of each detector for the major artificial radionuclides that could be released in nuclear accidents were calculated. As a result, the relative MDA values of each detector regarding surface deposition distribution at normal environmental radiation level were evaluated as high in the order of the NaI(Tl), $LaBr_3$(Ce), and $CeBr_3$ detectors. These results were compared based on each detector's intrinsic and measurement environment background, detection efficiency, and energy resolution for the gamma-ray energy region of the radionuclide of interest.

A Study on the Measurement of the Relative Nuclear Reaction Cross-Section of the natW(p,xn)176Re Reaction using 100 MeV Proton (100 MeV 양성자를 이용한 natW(p,xn)176Re 핵반응의 상대 핵반응단면적 측정에 대한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.257-263
    • /
    • 2021
  • This study derives the relative cross-section for the natW(p,xn)176Re nuclear reaction by measuring the gamma rays generated from the nuclear reaction with natural tungsten using a 100 MeV linear accelerator of the Korea Multi-purpose Accelerator Complex in the Korea Atomic Energy Research Institute. In general, research on isotopes with a short half-life always shows a tendency that the intensity of radioactivity decreases rapidly within a short period of time, making it very difficult to measure itself. In particular, 176Re is one of the relatively short radionuclides with a half-life of 5.3 minutes. In this study, 109.08 keV gamma rays generated from the 176Re isotope having such a short half-life were measured using a high-purity Ge detector(HPGe detector). The obtained relative measurements were the results in the 8 to 14 MeV proton energy domain published by Richard G. in 1967, and the TENDL-2019 value, which was the result of A. J. Koning in 2019, which evaluated the nuclear reaction cross-section by calculation based on this comparative analysis was performed. The results of this study are expected to be usefully applied to the design of nuclear fusion reactor which is known as future energy sources, elements ratio for the nuclear synthesis of astrophysics.

Quality Control of Dose Calibrator using 3D Printery (3D 프린터를 이용한 Dose Calibrator의 품질관리)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.307-312
    • /
    • 2021
  • In nuclear medicine, radioactive isotope tracers are administered to the human body to obtain and evaluate disease morphological information and biological function information. Dose calibrator is a device used to measure the radioactivity of a single nuclide in medical institutions. Administration of the correct dose to the human body acts as an important factor in diagnosis and treatment, and measurement through a dose calibrator before administration is the most important factor. Dose calibrator performs daily quality control after installation in each medical institution. Quality control is a means of guaranteeing quality control after installation, and is essential for improving the quality of treatment and promoting patient safety. Therefore, accurate and standardized performance evaluation methods should be established. In this study, 3D printing was used for quantitative evaluation of quality control by increasing the accuracy and standardization of quality control. When the 3D printer was installed and reproducibility was tested, the error range of the expected value and reading value decreased by 0.302% in the F-18 nuclide and 0.09% in the 99mTc-pertechnate nuclide than when the 3D printer was installed. The error rate for other nuclides was also found to have a low error rate for reproducibility tests when 3D printing was installed.

Radon Hazard Review of Spilled Groundwater and Tap Water in Incheon Metropolitan City Subway Station (인천광역시 지하철 역사 내 지하수 및 수돗물의 라돈 위해성 검토)

  • Lee, Yoo-Sang;Lee, Sang-Bok;Kang, Min-Seok;Jeong, Dong-Ha;Kim, Jin-Hong;Oh, Yoon-Sik;Choi, Se-Rin;Park, Jeong-Soo;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.671-677
    • /
    • 2021
  • Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.