• Title/Summary/Keyword: Radioactive Source

Search Result 285, Processing Time 0.028 seconds

Neutron Count Rate Measurement of $UO_2$ powder by Neutron Source

  • Kang Hee-Young;Koo Gil-Mo;Ha Jang-Ho;Kim Ho-Dong;Yang Myung-Seung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.344-349
    • /
    • 2005
  • Neutron count rate measurements to assay fissile content of uranium powder have been carried out in a neutron counter. The induced fission neutrons by Cf-252 neutron source are counted as the variation of fissile material in fuel material. The measured counts are compared with equivalent results obtained from calculation. It shows that the measured neutron counts versus quantity of $UO_2$ powder enrichment agreed reasonably well with the calculated values.

  • PDF

Remote handling systems for the Selective Production of Exotic Species (SPES) facility

  • Giordano Lilli ;Lisa Centofante ;Mattia Manzolaro ;Alberto Monetti ;Roberto Oboe;Alberto Andrighetto
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.378-390
    • /
    • 2023
  • The SPES (Selective Production of Exotic Species) facility, currently under development at Legnaro National Laboratories of INFN, aims at the production of intense RIB (Radioactive Ion Beams) employing the Isotope Separation On-Line (ISOL) technique for interdisciplinary research. The radioactive isotopes of interest are produced by the interaction of a multi-foil uranium carbide target with a 40 MeV 200 μA proton beam generated by a cyclotron proton driver. The Target Ion Source (TIS) is the core of the SPES project, here the radioactive nuclei, mainly neutron-rich isotopes, are stopped, extracted, ionized, separated, accelerated and delivered to specific experimental areas. Due to efficiency reasons, the TIS unit needs to be replaced periodically during operation. In this highly radioactive environment, the employment of autonomous systems allows the manipulation, transport, and storage of the TIS unit without the need for human intervention. A dedicated remote handling infrastructure is therefore under development to fulfill the functional and safety requirement of the project. This contribution describes the layout of the SPES target area, where all the remote handling systems operate to grant the smooth operation of the facility avoiding personnel exposure to a high dose rate or contamination issues.

Study of Classification and Disposal Method for Disused Sealed Radioactive Source in Korea (국내 폐밀봉선원 분류체계 및 처분방식 연구)

  • Kim, Sukhoon;Kim, Juyoul;Lee, Seunghee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.253-266
    • /
    • 2016
  • In accordance with the classification system of radioactive waste in Korea, all the disused sealed radioactive sources (DSRSs) fall under the category of EW, VLLW or LILW, and should be managed in compliance with the restrictions for the disposal method. In this study, the management and disposal method are drawn in consideration of half-life of radionuclides contained in the source and A/D value (i.e. the activity A of the source dividing by the D value for the relevant radionuclide, which is used to provide an initial ranking of relative risk for sources) in addition to the domestic classification scheme and disposal method, based on the characteristic analysis and review results of the management practices in IAEA and foreign countries. For all the DSRSs that are being stored (as of March 2015) in the centralized temporary disposal facility for radioisotope wastes, applicability of the derivation result is confirmed through performing the characteristic analysis and case studies for assessing quantity and volume of DSRSs to be managed by each method. However, the methodology derived from this study is not applicable to the following sources; i) DSRSs without information on the radioactivity, ii) DSRSs that are not possible to calculate the specific activity and/or the source-specific A/D value. Accordingly, it is essential to identify the inherent characteristics for each of DSRSs prior to implementation of this management and disposal method.

Measurement and Estimation for the Clearance of Radioactive Waste with Patients of Thyroid Treatment (갑상선 진료환자 관련 방사성폐기물의 처분을 위한 방사능 측정 및 평가)

  • Kim, Chang-Bum;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.6
    • /
    • pp.255-261
    • /
    • 2014
  • The generation amount of radioactive waste has been rapidly increased by increase of the usage of radioisotope source in medical field. Especially, the use of the radioactive source of I-131 with short half-life of 8.02 days used in treatment of thyroid has been increased, and all of the wastes concerned have been disposed by means of the self-disposal method. IAEA proposed criteria for clearance level of waste which depends on the individual (10 ${\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, various radioactive wastes in medical fields are collected and measured for establishing the disposal methods and procedures of radioactive wastes. In addition, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and analytical half-life is considered. With comparing the theoretical half-life and the effective half life(7.72 days) which was based on the decay equation of measured data, it is resulted in the theoretical half-life is longer than effective half-life. The storage period of radioactive waste for self-disposal may be curtailed. The result of this study will be proposed as ISO standard.

A Study of Radioactive Contamination in Hospital Toilet (병원 화장실의 방사성 오염에 관한 연구)

  • Kim, Ki-Jin;Kim, Gha-Jung
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.241-246
    • /
    • 2015
  • Generally a patient who was injected radiopharmaceuticals for nuclear medicine examination is not an object of isolation. Therefore, when the patient uses toilet, we expect surface contamination of a toilet by radioisotope. The measured value is $25.69Bq/cm^2$(a restroom near admission and administration), $19.39Bq/cm^2$(a toilet near department of radiology). The study shows that 9 of 24 locations in controlled area exceed over surface contamination limit. From now on, we should find source of contamination through measurement radioactive nuclide to apply radiation safety management.

The Assessment of Exposure Dose of Radiation Workers for Decommissioning Waste in the Radioactive Waste Inspection Building of Low and Intermediate-Level Radioactive Waste Disposal Facility (경주 중·저준위방사성폐기물 처분시설의 방폐물검사건물에서 해체 방사성폐기물 대상 방사선작업종사자의 피폭선량 평가 및 작업조건 도출)

  • Kim, Rin-Ah;Dho, Ho-Seog;Kim, Tae-Man;Cho, Chun-Hyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.317-325
    • /
    • 2020
  • The Korea Radioactive Waste Agency plans to expand the storage capacity of radioactive waste by constructing a radioactive waste inspecting building to solve the problem of the lack of inspection space and drum-handling space in the radioactive waste receipt and storage building for the first-stage disposal facility. In this study, the exposure doses of radiation workers that handle new disposal containers for decommissioning waste in the storage areas of the radioactive waste inspecting building were calculated using the Monte Carlo N-particle transport code. The annual collective dose was calculated as a total of 84.8 man-mSv for 304 new disposal containers and an estimated annual 306 working hours for the radiation work. When the 304 new disposal containers (small/medium type) were stored in the storage areas, it was found that 25 radiation workers should be involved in acceptance/disposal inspection, and the estimated exposure dose per worker was calculated as an average annual value of 3.39 mSv. When the radiation workers handle the small containers in high-radiation dose areas, the small containers should be shielded further by increasing the concrete liner thickness to improve the work efficiency and radiation safety of the radiation workers. The results of this study will be useful in establishing the optimal radiation working conditions for radiation workers using the source term and characteristics of decommissioning waste based on actual measurements.

Determination of Self-Disposal date by the Analysis of Radioactive Waste Contamination for 1131I Therapy Ward (131I 치료입원실 폐기물 방사능 오염도 분석 및 자체처분가능일자 산출)

  • Kim, Gi-sub;Jung, Haijo;Park, Min-seok;Jeon, Gjin-seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.3-6
    • /
    • 2013
  • Purpose: The treatment of thyroid cancer patients was continuously increased. According to the increment of thyroid cancer patients, the establishment of iodine therapy site was also increased in each hospital. This treatment involves the administration of radioactive iodine, which will be given in the form of a capsule. Therefore, protections and managements for radioactive source pollution and radiation exposure should be necessary for radiation safety. Among the many problems, the problem of disposing the radioactive wastes was occurred. In this study, The date for self-disposal for radioactive wastes, which were contaminated in clothes, bedclothes and trash, were calculated. Materials and Methods: The number of iodine therapy ward was 15 in Korea Institute of Radiological Medical and Sciences. Recently, 8 therapy wards were operated for iodine therapy patients and others were on standby for emergency treatment ward of any radiation accidents. Radioactive wastes, which were occurred in therapy ward, were clothes, bedclothes, bath cover for patients washing water and food and drink which was leftover by patients. Each sample was hold into the marinelli beaker (clothes, bedclothes, bath covers) and 90 ml beaker (food, drink, and washing water). The activities of collected samples were measured by HpGe MCA device (Multi Channel Analysis, CANBERRA, USA) Results: The storage period for the each kind of radioactive wastes was calculated by equation of storage periods based on the measurement outcomes. The average storage period was 60 days for the case of clothes, and the maximum storage period was 93 days for patient bottoms. The average storage period and the maximum storage period for the trash were 69 days and 97 days, respectively. The leftover foods and drinks had short storage period (the average storage period was 25 days and maximum storage period was 39 days), compared with other wastes. Conclusion: The proper storage period for disposing the radioactive waste (clothes, bedclothes and bath cover) was 100 days by the regulation on self-disposal of radioactive waste. In addition, the storage period for disposing the liquid radioactive waste was 120 days. The current regulation for radioactive waste self-disposing was not suitable for the circumstances of each radioactive therapy facility. Therefore, it was necessary to reduce the leftover food and drinks by adequate table setting for patients, and improve the process and regulation for disposing the short-half life radioactive wastes.

  • PDF

Implementation of a Coded Aperture Imaging System for Gamma Measurement and Experimental Feasibility Tests

  • Kim, Kwangdon;Lee, Hakjae;Jang, Jinwook;Chung, Yonghyun;Lee, Donghoon;Park, Chanwoo;Joung, Jinhun;Kim, Yongkwon;Lee, Kisung
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.1
    • /
    • pp.66-70
    • /
    • 2017
  • Radioactive materials are used in medicine, non-destructive testing, and nuclear plants. Source localization is especially important during nuclear decommissioning and decontamination because the actual location of the radioactive source within nuclear waste is often unknown. The coded-aperture imaging technique started with space exploration and moved into X-ray and gamma ray imaging, which have imaging process characteristics similar to each other. In this study, we simulated $21{\times}21$ and $37{\times}37$ coded aperture collimators based on a modified uniformly redundant array (MURA) pattern to make a gamma imaging system that can localize a gamma-ray source. We designed a $21{\times}21$ coded aperture collimator that matches our gamma imaging detector and did feasibility experiments with the coded aperture imaging system. We evaluated the performance of each collimator, from 2 mm to 10 mm thicknesses (at 2 mm intervals) using root mean square error (RMSE) and sensitivity in a simulation. In experimental results, the full width half maximum (FWHM) of the point source was $5.09^{\circ}$ at the center and $4.82^{\circ}$ at the location of the source was $9^{\circ}$. We will continue to improve the decoding algorithm and optimize the collimator for high-energy gamma rays emitted from a nuclear power plant.

The Study for the Fast Detection of the Stereo Radiation Detector using the Image Processing (영상처리기반 스테레오 감마선 탐지장치의 고속탐지에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1103-1105
    • /
    • 2015
  • Leaked Radioactive source in nuclear power station, radiation related facilities and the aging nuclear power plant for the dismantling must need to detect and remove early to prevent major accidents. In this paper, we implemented a single sensor-based gamma-ray detectors stereo which can provide the distance to the radiation source, a direction and doserate information for fast and efficient decontamination work the radiation source. And we have carried out an algorithm development for high-speed detection of the detection equipment. Two detectors are required for stereo structure for obtaining the distance information of the radioactive source, but we designed the only sensor-based detection device for the weight reduction. We have extracted the region of interest and obtained the distance calculation result and distribution of radiation source in order to minimize a stereo image acquisition time. Detection time of the algorithm showed a shorter time of about 41%.

  • PDF