• Title/Summary/Keyword: Radioactive Contamination

Search Result 187, Processing Time 0.029 seconds

Borehole Disposal Concept: A Proposed Option for Disposal of Spent Sealed Radioactive Sources in Tanzania (보어홀 처분 개념: 탄자니아의 폐밀봉선원 처분을 위한 제안)

  • Salehe, Mikidadi;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.4
    • /
    • pp.293-301
    • /
    • 2013
  • Borehole Disposal Concept (BDC) was initiated by the South African Nuclear Energy Corporation (NECSA) with the view to improve the radioactive waste management practices in Africa. At a time when geological disposal of radioactive waste is being considered, the need to protect ground water from possible radioactive contamination and the investigation of radionuclides migration through soil and rocks of zone of aeration into ground water has becomes very imperative. This is why the Borehole Disposal Concept (BDC) is being suggested to address the problem. The concept involves the conditioning and emplacement of disused sealed radioactive sources in an engineered facility of a relatively narrow diameter borehole (260 mm). Tanzania is operating a Radioactive Waste Management Facility where a number of spent sealed radioactive sources with long and short half lives are stored. The activity of spent sealed radioactive sources range from (1E-6 to 8.8E+3 Ci). However, the long term disposal solution is still a problem. This study therefore proposing the country to adopt the BDC, since the repository requires limited land area and has a low probability of human intrusion due to the small footprint of the borehole.

AN INTEGRATED APPROACH TO RISK-BASED POST-CLOSURE SAFETY EVALUATION OF COMPLEX RADIATION EXPOSURE SITUATIONS IN RADIOACTIVE WASTE DISPOSAL

  • Seo, Eun-Jin;Jeong, Chan-Woo;Sato, Seichi
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.6-11
    • /
    • 2010
  • Embodying the safety of radioactive waste disposal requires the relevant safety criteria and the corresponding stylized methods to demonstrate its compliance with the criteria. This paper proposes a conceptual model of risk-based safety evaluation for integrating complex potential radiation exposure situations in radioactive waste disposal. For demonstrating compliance with a risk constraint, the approach deals with important exposure scenarios from the viewpoint of the receptor to estimate the resulting risk. For respective exposure situations, it considers the occurrence probabilities of the relevant exposure scenarios as their probability of giving rise to doses to estimate the total risk to a representative person by aggregating the respective risks. In this model, an exposure scenario is simply constructed with three components:radionuclide release, radionuclide migration and environment contamination, and interaction between the contaminated media and the receptor. A set of exposure scenarios and the representative person are established from reasonable combinations of the components, based on a balance of their occurrence probabilities and the consequences. In addition, the probability of an exposure scenario is estimated on the assumption that the initiating external factors influence release mechanisms and transport pathways, and its effect on the interaction between the environment and the receptor may be covered in terms of the representative person. This integrated approach enables a systematic risk assessment for complex exposure situations of radioactive waste disposal and facilitates the evaluation of compliance with risk constraints.

Remote handling systems for the Selective Production of Exotic Species (SPES) facility

  • Giordano Lilli ;Lisa Centofante ;Mattia Manzolaro ;Alberto Monetti ;Roberto Oboe;Alberto Andrighetto
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.378-390
    • /
    • 2023
  • The SPES (Selective Production of Exotic Species) facility, currently under development at Legnaro National Laboratories of INFN, aims at the production of intense RIB (Radioactive Ion Beams) employing the Isotope Separation On-Line (ISOL) technique for interdisciplinary research. The radioactive isotopes of interest are produced by the interaction of a multi-foil uranium carbide target with a 40 MeV 200 μA proton beam generated by a cyclotron proton driver. The Target Ion Source (TIS) is the core of the SPES project, here the radioactive nuclei, mainly neutron-rich isotopes, are stopped, extracted, ionized, separated, accelerated and delivered to specific experimental areas. Due to efficiency reasons, the TIS unit needs to be replaced periodically during operation. In this highly radioactive environment, the employment of autonomous systems allows the manipulation, transport, and storage of the TIS unit without the need for human intervention. A dedicated remote handling infrastructure is therefore under development to fulfill the functional and safety requirement of the project. This contribution describes the layout of the SPES target area, where all the remote handling systems operate to grant the smooth operation of the facility avoiding personnel exposure to a high dose rate or contamination issues.

Filtration System and its Efficiency of Exhaust System at Post Irradiation Examination Facility (조사후시험시설에서의 방사성 오염배기체의 포집장치 및 여과효율)

  • 황용화;이형권;전용범;민덕기;엄성호;홍권표
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.96-100
    • /
    • 2003
  • Filtering system is installed at post irradiation examination facility(PIEF) to maintain optimized operating condition of the facility by keeping different negative pressure condition depending on contamination level in the PIEF due to its treatment of radioactive materials. Inspection on each system, filter leak test and other related test are periodically performed as the performance test for increasing operational efficiency and safety.

  • PDF

Study on Radioactive Contamination of Plant Nearby Nuclear Power Plant - Focused on Pinus thunbergii Parl. and Viburnum awabuki K. KOCH - (원전주변 지역 식물의 방사능 오탁에 관한 연구 - 해송과 아왜나무를 대상으로 -)

  • Kang, Tai-Ho;Zhao, Hong-Xia;Jeong, Jin-Wook;Kook, Seong-Do
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.3
    • /
    • pp.55-62
    • /
    • 2013
  • Generally, the radioactivity from NPP(Nuclear Power Plants) operation can be released below 3% of DRLs(Derived Release Limits) to environment. It was tried to understand which plant was efficient for absorbing radioactivity in this study. Pinus thunbergii Parl. and Viburnum awabuki K. KOCH were analyzed for radioisotope absorption. The samples were collected at three different locations depending on the distance from NPP at the vicinity 10km away, and 30km away. Gamma radionuclide was not detected from the samples, which means that the direct transition into the plant was not significant. Meanwhile, the very low level of radioactive tritium was detected in the samples. One remark was that every plant has different ability for tritium absorption. These results are expected to be applied to propagation and transplanting in radioactively contaminated area or reducing radioactivity in the soil and water near the plants.

Study on HVAC System in Nuclear Facility (원자력시설의 공기조화 시스템 고찰)

  • 백상열;송웅섭;오연우;주용선;홍권표
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.503-508
    • /
    • 2003
  • Heating, Ventilation and hir Conditioning (HVAC) system in nuclear facility should be equipped and constructed more stable and allowable than that in common facility. The purpose of HVAC system is the maintenance of optimum working environment, the protection of worker against a contaminated air and the prevention of atmospheric contamination due to a outward ventilation, etc.. The basic scheme of a safety operation of nuclear facility is to prevent the atmospheric contamination even in low level. The adaptability of HVAC system should be taken into account in the design stage so that it is possible to modify the system which is in operation. In this study, the design requirements of HVAC system in nuclear facility and the HVAC systems in foreign countries are reviewed, and the results can be utilized in the design of HVAC system in nuclear facility.

  • PDF

Development of a real-time gamma camera for high radiation fields

  • Minju Lee;Yoonhee Jung;Sang-Han Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.56-63
    • /
    • 2024
  • In high radiation fields, gamma cameras suffer from pulse pile-up, resulting in poor energy resolution, count losses, and image distortion. To overcome this problem, various methods have been introduced to reduce the size of the aperture or pixel, reject the pile-up events, and correct the pile-up events, but these technologies have limitations in terms of mechanical design and real-time processing. The purpose of this study is to develop a real-time gamma camera to evaluate the radioactive contamination in high radiation fields. The gamma camera is composed of a pinhole collimator, NaI(Tl) scintillator, position sensitive photomultiplier (PSPMT), signal processing board, and data acquisition (DAQ). The pulse pile-up is corrected in real-time with a field programmable gate array (FPGA) using the start time correction (STC) method. The STC method corrects the amplitude of the pile-up event by correcting the time at the start point of the pile-up event. The performance of the gamma camera was evaluated using a high dose rate 137Cs source. For pulse pile-up ratios (PPRs) of 0.45 and 0.30, the energy resolution improved by 61.5 and 20.3%, respectively. In addition, the image artifacts in the 137Cs radioisotope image due to pile-up were reduced.

Development of Automatic Smear Equipment for Measuring Surface Radioactivity Contamination (표면방사선 오염도 측정용 자동 스미어장치의 개발)

  • Tack, Han-Ho;Kang, Shin-Chool
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.4
    • /
    • pp.37-44
    • /
    • 2011
  • This paper was development of surface contamination automatic smear sampling for measuring radioactive contamination in radiation controlled area of nuclear facility. In indirect method a smear paper are used manually. Activity on the smear paper is affected by varying the pressures applied, by the smearing time, by the difference of ares sampled during smearing. By means of these there are erroneous. In the future the apparatus will be developed as a portable apparatus measuring smear activity automatically by adding radiation detection instrument.

Study of Radiation Mapping System for Water Contamination in Water System (방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구)

  • Na, Teresa W.;Kim, Han Soo;Yeon, Jei Won;Lee, Rena;Ha, Jang Ho
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.

Evaluation on the Dismantling Activities of the KRR-2 Radioisotope Production Facilities (연구로 2호기 동위원소생산시설 해체활동 평가)

  • 박승국;천은영;박진호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.671-675
    • /
    • 2003
  • In accordance with the KRR-1 & 2 decommissioning project, the decontamination and dismantling activities of the KRR-2 auxiliary facilities, radioisotope production facilities, were completed from Aug 2001 to Dec 2002. The auxiliary facilities were composed of the concrete hot-cell, lead hot-cells and several laboratories for the radioisotope production. The dismantling objects are home hoods, experimental desks, sinks, and contaminated inner facilities. For the purpose of the safe decommissioning activity, the method statements and working procedures were set up. The manpower of the total 20,933 man-hour was required and several dismantling equipments were also. The maximum surface contamination is: 9.24 Bq/$\textrm{cm}^2$ in removable contamination and 350,000 cpm in fixed contamination. The total amount of 62.146 Ton was raised as dismantled waste with kinds of the concretes, wood, steels, etc. The collective dose was evaluated as 0.33 mam-mSv during this period.

  • PDF