• 제목/요약/키워드: Radio Therapy

검색결과 116건 처리시간 0.025초

Preventive and Therapeutic Effects of Quercetin on Experimental Radiation Induced Lung Injury in Mice

  • Wang, Juan;Zhang, Yuan-Yuan;Cheng, Jian;Zhang, Jing-Ling;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권7호
    • /
    • pp.2909-2914
    • /
    • 2015
  • Objective: To investigate the protective effect of quercetin on radiation induced lung injury (RILI) and related mechanisms. Materials and Methods: Mice treated with radiation and/or quercetin were sacrificed at 1-8 weeks after irradiation under anesthesia. Lung tissues were collected for histological examination. Immunohistochemistry (IHC) and Western blotting were performed to detect the protein expression of nuclear factor-${\kappa}B$ ($NF-{\kappa}B$) and Mitogen-activated protein kinases (MAPK) pathway. Results: Hematoxylin and eosin (HE) staining showed that radiation controls displayed more severe lung damage than quercetin groups, either high or low dose. Results of IHC and Western blotting demonstrated the expression level of $NF-{\kappa}B$ to be decreased and that of an inhibitor of $NF-{\kappa}B$ ($I{\kappa}b-{\alpha}$) to be increased by the quercetin intervention compared with the radiation control group. Numbers of JNK/SAPK, p38 and p44/p42 positive inflammatory cells were decreased in the radiation+quercetin injection group (P<0.05). Conclusions: Quercetin may play a radio-protective role in mice lung via suppression of $NF-{\kappa}B$ and MAPK pathways.

노인 친화적 감성용 욕조 대안에 대한 노인 소비자의 요구 및 평가 (A Survey on the Aged Consumers' Needs for an Elderly Friendly and Sensitive Bathtub Alternative)

  • 최병숙;권대규
    • 한국주거학회논문집
    • /
    • 제24권6호
    • /
    • pp.41-49
    • /
    • 2013
  • This study finds out the aged consumers' needs on the developing elderly friendly and sensitive bathtub. This bathtub focuses on enhancement of multi-senses and enhancement of health, safety & convenience during bath. The enhancing multi-senses would have four functions; therapy with color and aroma, the massage with micro water bubbles, the visual and auditory with TV & cinema, and the auditory with music and radio. Also, enhancing others of bathtub would have seven functions; emergency bell, blood-pressure check system for health condition, water temperature indicator, keeping water warm, reading a book in that, and controlling of house entrance door and a getting the phone during bath. The aged consumers' needs find throughout a questionnaire survey, and 497 data was analyzed. The main results are as follow. They consider a full bath behavior as a healthcare. They have an intention to purchase or use the elderly and friendly bathtub, and they prefer using it in common facilities to using it at home. They highly need health related function of bathtub, which are massage (64.4%), blood-pressure check system (55.1%) and aroma therapy (45.7%). The emergency bell (67.0%), keeping water warm (62.2%), and water temperature indicator (49.7%), related to safety & information function of bathtub, are needed. Also, they think tolerance for error and low physical effort in bathtub design alternative, opening door and inside sitting support, to be important.

고(高)에너지 전자선(電子線) 치료(治療)를 위(爲)한 선량분포(線量分布) 및 기술적(技術的) 문제(問題)의 연구(硏究) (Studies on Dose Distribution and Treatment Technique of High Energy Electron)

  • 이도행;추성실
    • Journal of Radiation Protection and Research
    • /
    • 제3권1호
    • /
    • pp.6-22
    • /
    • 1978
  • High energy electron beams took effect for tumor radio-therapy, however, had a lot of problems in clinical application because of various conversion factors and complication of physical reactions. Therefor, we had experimentally studied the important properties of high energy electron beams from the linear accelerator, LMR-13, installed in Yonsei Cancer Center. The results of experimental studies on the problems in the 8, 10, 12 Mev electron beam therapy were reported as following. 1. On the measurements of the outputs and absorbed doses, the ionization type dosimeters that had calibrated by $^{90}Sr$ standard source were suitable as under 3% errors for high energy electrons to measure, but measuring doses in small field sizes and the regions of rapid fall off dose with ionization chambers were difficult. 2. The electron energy were measured precisely with energy spectrometer consisted of magnet analyzer and tele-control detector and the practical electron energy was calculated under 5% errors by maximum range of high energy electron beam in the water. 3. The correcting factors of perturbated dose distributions owing to radiation field, energy and material of the treatment cone were checked and described systematically and variation of dose distributions due to inhomogeneous tissues and sloping skin surfaces were completely compensated. 4. The electron beams, using the scatterers; ie., gold, tin, copper, lead, aluminium foils, were adequately diffused and minimizing the bremsstrahlung X-ray induced by the electron energy, irradiation field size and material of scatterers, respectively. 5. Inproving of the dose distribution from the methods of pendulum, slit, grid and focusing irradiations, the therapeutic capacity with limited electron energy could be extended.

  • PDF

Serum Vascular Endothelial Growth Factor-A (VEGF-A) as a Biomarker in Squamous Cell Carcinoma of Head and Neck Patients Undergoing Chemoradiotherapy

  • Srivastava, Vikas Kumar;Gara, Rishi Kumar;Rastogi, Namrata;Mishra, Durga Prasad;Ahmed, Mohd Kaleem;Gupta, Shalini;Goel, Madhu Mati;Bhatt, Madan Lal Brahma
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권7호
    • /
    • pp.3261-3265
    • /
    • 2014
  • Background: To evaluate serum VEGF-A levels in squamous cell carcinoma of head and neck (SCCHN) patients and relationships with response to therapy. Materials and Methods: Serum VEGF-A levels in patients (n=72) treated with radiotherapy (RT) or radio-chemotherapy (RCT) and controls (n=40) were measured by ELISA. Results: Serum VEGF-A levels of the SCCHN cases were significantly higher (p=0.001) than in healthy controls, and in patients with positive as compared to negative lymph node status (p=0.004). Similarly, patients with advanced stage (Stage III-IV) disease had more greatly elevated levels of serum VEGF-A level than their early stage (Stage I-II) counterparts (p=0.001). In contrast, there was no significant difference (p=0.57) in serum level of VEGF-A in patients with advanced T-stage (T3-4) as compared to early stage (T1-2). Similarly, patients with distant metastasis had no significant (p=0.067) elevation in serum VEGF-A level as compared to non-metastatic disease. However, the non-responder patients had significantly higher serum VEGF-A level as compared to responders (p=0.001). Conclusions: Our results suggest that the serum VEGF-A level may be a useful biomarker for the prediction of response to therapy in SCCHN.

Radiolabeling of antibody-mimetic scaffold protein with 99mTc tricarbonyl precursor via hexahistidine (His6)-tag

  • Shim, Ha Eun;Kim, Do Hee;Lee, Chang Heon;Choi, Dae seong;Lee, Dong-Eun
    • 대한방사성의약품학회지
    • /
    • 제5권1호
    • /
    • pp.11-17
    • /
    • 2019
  • Recently, antibody-like scaffold proteins have received a great deal of interest in diagnosis and therapy applications because of their intrinsic features that are often required for tumor imaging and therapy. Intrinsic issues that are associated with therapeutic application of antibody-like scaffold proteins, particularly in cancer treatment, include an efficient and straightforward radiolabeling for understanding in vivo biodistribution and excretion route, and monitoring therapeutic responses. Herein, we report an efficient and straightforward method for radiolabeling of antibody-like scaffold proteins with the $[^{99m}Tc(OH_2)_3(CO)_3]^+$ ($^{99m}Tc$-tricarbonyl) by using a site-specific direct labeling method via hexahistidine-tag, which is a widely used for general purification of recombinant proteins with His-affinity chromatography. Repebody is a new class of antibody-like scaffold protein that consists of highly diverse leucine-rich repeat (LRR) modules. Although all possible biomedical applications with repebody are ongoing, it's in vivo biodistribution and excretion pathway has not yet been explored. In this study, hexahistidine ($His_6$)-tag bearing repebody (rEgH9) was labeled with [$^{99m}Tc$]-tricarbonyl. Repebody protein was radiolabeled with high radiolabeling efficiency (>90%) and radiolabeled compound was more than 99% pure after purification. These results clearly demonstrate that the present radiolabeling method will be useful molecular imaging study.

$^{192}Ir$source를 이용할 자궁경부암 강내치료시 사용하는 packing의 효과에 대한 고찰 (Packing effects on the intracavitary radiation therapy of the utaine lervix cancer)

  • 조정근;이두현;시창근;최윤경;김태윤
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.73-77
    • /
    • 2004
  • 연구목적 : 자궁경부암 환자에게 시행되는 고선량을 강내조사의 경우 선원이 병소 근처에 위치함으로써 주변의 중요 장기에 최소의 선량이 투여될 수 있도록 치료계획이 가능하다. 하지만 해부학적 위치 상 방광과 직장이 병소와 근접하여, 선량을 최소화하고자 Packing을 시행한다. 본 연구에서는 실제 Packing의 효과를 알아보고자 모의치료시 packing을 시행한 것과 packing을 제거한 후의 사진을 얻어 ICRU(International Commission on Radiation Units) 38에 report 된 방광과 직장의 point dose를 비교하였다. 대상 및 방법 : Packing 전, 후의 방광과 직장의 선량변화를 알아보기 위하여 packing을 시행한 후 AP, LAT film을 촬영하고, 또한 동일한 상태에서 packing을 제거한 후 AP, LAT film을 촬영하여 확인하고자 하는 방광과 직장의 reference point를 각각 표시하고 이를 치료계획장치(PLATO BPS v13.7)에 입력한 후 ICRU 38 report에서 권고한대로 A point에 $100\%$ 선량을 prescription하는 치료계획을 시행하였다. 하지만 rectum의 경우 ICRU에서 제시한 point가 rectum point를 정확히 대변하지 못하는 이유로 maximum point를 찾아 비교하였다. 측정한 값들을 윌콕슨의 부호검정(SAS, 통계분석처리프로그램)을 통하여 packing 효과의 유의성에 대하여 분석하였다. 결 과 : packing을 시행하지 않은 상태에서의 방광과 직장 선량은 각각 $80.1{\pm}16.8(\%),\;82.7{\pm}16.3(\%)$이었고, packing을 시행한 경우 각각 $63.0{\pm}16.3(\%),\;67.6{\pm}16.3(\%)$로, 방광선량의 경우 평균선량이 $17.2{\pm}4.0(\%)$ 감소한 것으로 나타났으며, 직장선량의 경우 평균선량이 $15.1{\pm}9.9(\%)$ 감소한 것으로 나타났다. 이를 윌콕슨의 부호검정을 통하여 분석한 결과 방광과 직장 모두 검정통계량 값이 33으로 매우 크고 p 값이 0.001로서 매우 유의한 차이를 보이고 있다. 다시 말해서 $99\%$의 유의수준에서도 모평균(packing 여부에 따른 방광과 직장선량의 평균의 차이가 정량적 수치로 나타나 packing의 효과를 알 수 있다)의 차이가 뚜렷하다고 볼 수 있다. 결 론 : 자궁경부암에 있어 강내치료는 외부치료와 더불어 반드시 시행하여야 하는 치료로 인식되어 있다. 그 이유는 주변 주요장기인 방광과 직장을 피해 원발 병소에만 방사선량을 현저히 많은 양을 부여함으로써 높은 치료효과를 볼 수 있기 때문이다. 하지만 서른에서 언급하였듯이 해부학적으로 주요장기가 너무 인접하여 있기 때문에 이들을 인위적으로 분리시키지 않으면 안된다. 이러한 목적을 달성하기 위하여 packing을 사용하는데, 본 실험을 통하여 자궁경부암 강내치료시 사용하는 packing 방법의 효과가 매우 탁월함을 알 수 있었고 적극적인 packing을 통해 방사선치료시 가장 우려되는 주변의 정상조직의 부작용이 감소할 수 있도록 최선의 노력을 하여야 할 것으로 사료된다.

  • PDF

Monte Carlo Simulation of Small Photon Beam Measurements by Beam Intensity Scanner System(BISS)

  • Park, Kwangyl;Vahc, Young-Woo;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.282-284
    • /
    • 2002
  • We have developed and used BISS as a radiation detector to verify patient dose and determine the physical characteristics of beams used in Stereotatic Radio Surgery(SRS) and Intensity Modulated Radiation Therapy(IMRT). In order to confirm the function and accuracy of our BISS, we simulate our measurements by BISS under the radiation of 6MV photons from a Varian Clinac 21EX equipped with a 60 leaf pairs MLC. For the simulation based on the Monte Carlo algorithm, which remains the most comprehensive and accurate theoretical method to verify beam profiles, we use the BEAM code. Compared with the measurements by BISS, our simulation of variously shaped phantom measurements show good agreements. Our simulation results can be used as a theoretical standard to compare and confirm measurements by BISS and other dosimeters such as ultramicro cylindrical ionization chamber(UCIC) and radiographic film.

  • PDF

Monte Carlo Calculation of the Dose Profiles for a 6 MeV Electron Beam with Longitudinal Magnetic Fields

  • Jeong, Dong-Hyeok;Oh, Young-Kee;Kim, Jhin-Kee;Kim, Jeung-Kee;Shin, Kyo-Chul;Kim, Ki-Hwan;Lee, Jeong-Ok;Kang, Jeong-Ku;Moon, Sun-Rock
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.109-112
    • /
    • 2002
  • Using Monte Carlo calculations the effects of longitudinal magnetic fields on the beam profiles produced by clinical electron beam were studied. The Monte Carlo calculations were performed using the EGS4 code system modified to account for external magnetic fields. The beam profiles for a 6 MeV electron beam with longitudinal magnetic fields of 0.5-3.0 T were calculated. As a result of these calculations we found that the penumbra widths can be reduced with increased magnetic fields. This means that the electron therapy benefits from the external magnetic fields.

  • PDF

Meta Analysis of Treatment for Stage IE~IIE Extranodal Natural Killer /T Cell Lymphomas in China

  • Li, Hui;Wang, Chun-Sen;Wang, Xiao-Dong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권5호
    • /
    • pp.2297-2302
    • /
    • 2014
  • Objective: To evaluate early treatment for extranodal natural killer/T cell lymphoma (ENK/TCL) in China and provide reference for clinical treatment of these patients. Methods: Computer-based retrieval was performed in PubMed, CNKI, CBM, VIP and WanFang Data to search for randomized controlled trials (RCTs) of treatment for early ENK/TCL, and a meta-analysis was conducted with RevMan 5.0 software. Results: A total of 11 RCTs, including 871 patients, were selected, of which the first radiotherapy had a higher complete response (CR) than the first chemotherapy [OR=14.16, 95%CI (8.68, 23.10), P<0.00001] and CR was not different between combined treatment group and radiotherapy group [OR=1.86, 95%CI (0.47, 3.58), P=0.61], but long-term survival rate was higher with combined treatment[OR=1.88, 95%CI (1.09, 3.19), P=0.02]. No difference in survival rate was observed between radio-chemotherapy and chemo-radiotherapy groups [OR=1.11, 95%CI (0.73, 1.69), P=0.63]. Conclusions: Radiotherapy is of great significance in the treatment of early ENK/TCL, but combined therapy could further enhance long-term survival rate of patients. This conclusion still requires further confirmation using RCTs with high quality and large sample size.

The ways for ginsenoside Rh2 to fight against cancer: the molecular evidences in vitro and in vivo.

  • Qi-rui Hu;Yao Pan;Han-cheng Wu;Zhen-zhen Dai;Qing-xin Huang;Ting Luo;Jing Li;Ze-yuan Deng;Fang Chen
    • Journal of Ginseng Research
    • /
    • 제47권2호
    • /
    • pp.173-182
    • /
    • 2023
  • Cancer is a global public health issue that becomes the second primary cause of death globally. Considering the side effects of radio- or chemo-therapy, natural phytochemicals are promising alternatives for therapeutic interventions to alleviate the side effects and complications. Ginsenoside Rh2 (GRh2) is the main phytochemical extracted from Panax ginseng C.A. Meyer with anticancer activity. GRh2 could induce apoptosis and autophagy of cancer cells and inhibit proliferation, metastasis, invasion, and angiogenesis in vitro and in vivo. In addition, GRh2 could be used as an adjuvant to chemotherapeutics to enhance the anticancer effect and reverse the adverse effects. Here we summarized the understanding of the molecular mechanisms underlying the anticancer effects of GRh2 and proposed future directions to promote the development and application of GRh2.