• 제목/요약/키워드: Radiation-beam

검색결과 1,773건 처리시간 0.024초

고춧가루 오염 미생물의 제어에서 방사선종별 조사 효과 (Comparison of Irradiation Effect of Different Radiation Types on Decontamination of Microorganisms in Red Pepper Powder)

  • 박경숙
    • 방사선산업학회지
    • /
    • 제8권1호
    • /
    • pp.1-5
    • /
    • 2014
  • This study investigated the reduction of microbial population and sensory properties in red pepper powders irradiated by gamma ray, electron beam, and X-ray. Populations of total aerobic bacteria and yeast & molds in red pepper powders were decreased by irradiation treatment in a dose-dependent manner. Gamma ray, electron beam, and X-ray at doses above 8 kGy caused 100% inhibition on growth of aerobic bacteria in red pepper powders. Inhibitory activity of X-ray on sterilization of red pepper powders was significantly equal to or higher compared to gamma ray and electron beam. Color and off flavor in red pepper powders were no significant difference among the control and samples irradiated with gamma ray, electron beam, and X-ray. As a result, the gamma ray, electron beam, and X-ray irradiation can be used to sterilize the microbial growth in red pepper powders without quality loss.

Design, construction, and characterization of a Prompt Gamma Neutron Activation Analysis (PGNAA) system at Isfahan MNSR

  • M.H. Choopan Dastjerdi;J. Mokhtari;M. Toghyani
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4329-4334
    • /
    • 2023
  • In this research, a prompt gamma neutron activation analysis (PGNAA) system is designed and constructed based on the use of a low power research reactor. For this purpose, despite the fact that this reactor did not include beam tubes, a thermal neutron beam line is installed inside the reactor tank. The extraction of the beam line from inside the tank made it possible to provide the neutron flux from the order of 106 n.cm-2.s-1. Also, because the beam line is installed in a tangential position to the reactor core, its gamma level has been minimized. Also, a suitable radiation shield is considered for the detector to minimize the background radiation and prevent radiation damage to the detector. Calculations and measurements are done in order to characterize this system, as well as spectrometry of several samples. The results of evaluations and experiments show that this system is suitable for performing PGNAA.

LID (Lyon Intraoperative Device) 이용한 수술중 방사선치료시 전자선의 선량분포 특성 (The dosimetric Properties of Electron Beam Using Lyon Intraoperative Device for Intraoperative Radiation Therapy)

  • 김계준;박경란;이종영;김희연;성기준;추성실
    • Radiation Oncology Journal
    • /
    • 제10권1호
    • /
    • pp.85-93
    • /
    • 1992
  • 수술중 방사선치료를 환자에 적용하기에 앞서 본원이 보유하고있는 LID를 이용한 전자선의 선량분포 특성을 연구하였다. 이러한 선량 특성에 대한 자료는 적절한 Cone의 모양이나 크기, 에너지를 결정하게하며 빠르고 정확한 계산을 위하여 필요하다. 따라서, 본 저자들은 3-Dimensional Water Phantom Dosimetry System를 이용하여 Cone의 크기, Cone의 모양, 보상필터 사용 유무에 따라 Cone의 출력인자, 조직표면선량, 선축상 최대치 지점, $90\%$의 깊이, 대칭도와 편평도, SSD 보상인자, 선량분포 등을 측정하여 다음과 같은 결과를 얻었다. 1) Cone의 출력인자는 Cone모양에 따라 각각 측정하였으며 Cone의 크기와 에너지가 작을수록 급격하게 감소하는 결과를 보였다. 2) 보상 필터의 하나인 Flattening Filter를 사용한 결과 포면 선량이 6 MeV, 9 MeV, 12 MeV에 대하여 각각 $85.3\%$, $89.2\%$, $93.4\%$였고, 이 보상 필터를 사용하므로 선량률과 beam의 투과율은 감소하지만 치료부위에 따라 beam의 모양을 변형시키며 특히, 표면선량을 $90\%$나 그 이상으로 증가시킬수 있었다. 3) 3차에 걸친 beam의 collimation과 보상 필터를 결합하여 사용한 결과 매우 좋은 beam의 균일성과 편평도 뿐만아니라 $90\%$ 등선량곡선 넓이가 커지는 결과를 보였다. 4) 치료를 위하여 중요한 간격인 SSD 100cm에서 SSD 110cm까지의 출력인자는 측정치와 계산치가 Cone의 크기와 모양, 에너지에 따라 $1\~3\%$의 차이를 보였다.

  • PDF

연속식 흐름 가스상물질의 전자선 분해반응에서 전류 세기가 반응효율 및 kinetics에 미치는 영향 (Effects of Current Intensity on the Reaction Efficiency and Kinetics of Gas Compound Decomposition by Electron Beam in a Continuous Flow System)

  • 김탁현;김동우;조상희;손지은;유승호;김태훈;박종석
    • 방사선산업학회지
    • /
    • 제18권3호
    • /
    • pp.235-240
    • /
    • 2024
  • Electron beam technology has recently attracted attention as one of the powerful air pollution control methods. In this study, methyl mercaptan decomposition by electron beam in a continuous gas flow system was studied. To this, the effect of gas flowrate, which is one of important operating variables in the continuous gas flow electron beam process, on methyl mercaptan treatment efficiency was studied. In particular, the treatment efficiency and the reaction kinetics of methyl mercaptan decomposition were compared when calculated based on the absorbed dose and when calculated based on the current intensity of electron beam. When based on the electron beam absorbed dose, the treatment efficiency and 1st-order reaction constant increased as the gas flowrate was increased, contrary to the trends in general chemical reactions. However, when based on the current intensity, the treatment efficiency and 1st-order reaction constant increased as the gas flowrate was decreased, which can be theoretically explained. This is due to the fact that the current intensity increased as the gas flowrate was increased, resulting in improved the electron beam treatment efficiency. In conclusion, it is necessary to consider not only the absorbed dose but also the current intensity of electron beam in order to explain the results of reaction efficiencies and kinetics in the continuous flow electron beam gas treatment process.

Comparison Study on Changes of Antigenicities of Egg Ovalbumin Irradiated by Electron Beam or X-Ray

  • Kim, Mi-Jung;Lee, Ju-Woon;Sung, Nak-Yoon;Kim, Su-Min;Hwang, Young-Jung;Kim, Jae-Hun;Song, Beom-Seok
    • 한국축산식품학회지
    • /
    • 제34권5호
    • /
    • pp.570-575
    • /
    • 2014
  • This study was conducted to compare the effects of two forms of radiation (electron and X-ray; generated by an electron beam accelerator) on the conformation and antigenic properties of hen's egg albumin, ovalbumin (OVA), which was used as a model protein. OVA solutions (2.0 mg/mL) were individually irradiated by electron beam or X-ray at the absorbed doses of 0 (control), 2, 4, 6, 8, and 10 kGy. No differences between the two forms of radiation on the structural properties of OVA were shown by spectrometric and electrophoretic analyses. The turbidity of OVA solution increased and the main OVA bands on polyacrylamide gels disappeared after irradiation, regardless of the radiation source. In competitive indirect enzyme-linked immunosorbent assay, OVA samples irradiated by electron beam or X-ray showed different immunological responses in reactions with monoclonal and polyclonal antibodies (immunoglobulin G) produced against non-irradiated OVA. The results indicate that electron beam irradiation and X-ray irradiation produced different patterns of structural changes to the OVA molecule.

The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

  • Chung, Kwangzoo;Han, Youngyih;Kim, Jinsung;Ahn, Sung Hwan;Ju, Sang Gyu;Jung, Sang Hoon;Chung, Yoonsun;Cho, Sungkoo;Jo, Kwanghyun;Shin, Eun Hyuk;Hong, Chae-Seon;Shin, Jung Suk;Park, Seyjoon;Kim, Dae-Hyun;Kim, Hye Young;Lee, Boram;Shibagaki, Gantaro;Nonaka, Hideki;Sasai, Kenzo;Koyabu, Yukio;Choi, Changhoon;Huh, Seung Jae;Ahn, Yong Chan;Pyo, Hong Ryull;Lim, Do Hoon;Park, Hee Chul;Park, Won;Oh, Dong Ryul;Noh, Jae Myung;Yu, Jeong Il;Song, Sanghyuk;Lee, Ji Eun;Lee, Bomi;Choi, Doo Ho
    • Radiation Oncology Journal
    • /
    • 제33권4호
    • /
    • pp.337-343
    • /
    • 2015
  • Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.

Dosimetric Comparison of 6 MV Flattening Filter Free and 6 MV Stereotactic Radiosurgery Beam Using 4 mm Conical Collimator for Trigeminal Neuralgia Radiosurgery

  • Mhatre, Vaibhav R;Chadha, Pranav;Kumar, Abhaya P;Talapatra, Kaustav
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.107-113
    • /
    • 2018
  • Background: The purpose of our study was to compare the dosimetric advantages of Flattening filter free (FFF) beams for trigeminal neuralgia patients using 4 mm conical collimators over previously treated patients with 6 MV SRS beam. Materials and Methods: A retrospective study was conducted for 5 TN patients who had been previously treated at our institution using frame-based, LINAC-based stereotactic radiosurgery (SRS) on Novalis Tx using 6 MV SRS beam were replanned on 6X FFF beams on Edge Linear accelerator with same beam angles and dose constraints using 4 mm conical collimator. The total number of monitor units along with the beam on time was compared for both Edge and Novalis Tx by redelivering the plans in QA mode of LINAC to compare the delivery efficiency. Plan quality was evaluated by homogeneity index (HI) and Paddick gradient index (GI) for each plan. We also analyzed the doses to brainstem and organ at risks (OARs). Results and Discussion: A 28% beam-on time reduction was achieved using 6X FFF when compared with 6X SRS beam of Novalis Tx. A sharp dose fall off with gradient index value of $3.4{\pm}0.27$ for 4 mm Varian conical collimator while $4.17{\pm}0.20$ with BrainLab cone. Among the 5 patients treated with a 4 mm cone, average maximum brainstem dose was 10.24 Gy for Edge using 6X FFF and 14.28 Gy for Novalis Tx using 6X SRS beam. Conclusion: The use of FFF beams improves delivery efficiency and conical collimator reduces dose to OAR's for TN radiosurgery. Further investigation is warranted with larger sample patient data.

An Empirical Approach to Dosimetric Effect of Carbon Fiber Couch for Flattening Filter Free Beam of Elekta LINAC

  • Ahn, Sohyun;Park, Kwangwoo;Kim, Jinsung;Lee, Ho;Yoon, Jeongmin;Lee, Eungman;Park, Sohyun;Park, Jeongeun;Kim, Juhye;Keum, Ki Chang
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.220-223
    • /
    • 2016
  • Generally, it is recommended that the dosimetric effect of carbon fiber couch should be considered especially for an intensity-modulated therapy with a large portion of monitor units from posterior angles. Even a flattening filter free (FFF) beam has been used for stereotactic body radiation therapy (SBRT), the effect of carbon fiber couch for FFF beam is not well known. This work is an effort to evaluate the dosimetric effect of carbon fiber couch for flattened and FFF beam of Elekta linac empirically. The absorbed doses were measured with Farmer type chamber and water-equivalent phantoms with and without couch. And differences of the absorbed doses between with and without couch defined as "couch effect". By comparing calculated dose in treatment planning system (TPS) with measured dose, the optimal density of couch was evaluated. Finally, differences on patient's skin dose and target dose by couch were evaluated in TPS. As a result, the couch effect for 6 and 10 MV flattened beam were -2.71% and -2.32%, respectively. These values were agreed with provided data by vendor within 0.5%. The couch effect for 6 and 10 MV FFF beam were -3.75% and -2.80%, respectively. The patient's skin dose was increased as 18.6% and target dose was decreased as 0.87%, respectively. It was realized that the couch effect of FFF beam was more severe than that of flattened beam. Patient's skin dose and target dose were changed by the couch effect.

전자선 조사가 베타글루칸의 항알레르기 활성에 미치는 영향 (Effect of Electron Beam Irradiation on the Anti-allergy Activity of β-Glucan)

  • 박종흠;성낙윤;변의백;송두섭;김재경;송범석;박상현;신미혜;이주운;김재훈;유영춘
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.267-272
    • /
    • 2012
  • This study evaluated the change in anti-allergy activity of ${\beta}-glucan$ by electron beam irradiation. ${\beta}-Glucan$ was irradiated at dose of 50 kGy and then orally pre-treated with electron beam irradiated and non irradiated ${\beta}-Glucan$ for 7 days. After pre-treatment, allergy was induced by injection of ovalbumin (OVA). Serum total immunoglobulin E (IgE) and OVA-specific IgE levels in the allergic mice was significantly increased but the mice pre-treated 50 kGy electron beam irradiated ${\beta}-glucan$ was significantly decreased the levels of total IgE and OVA-specific IgE, respectively. Moreover, cytokine production (interleukin-4) was also decreased in the 50 kGy electron beam irradiated ${\beta}-Glucan$ pre-treated mice. These results indicate that pre-treatment of 50 kGy electron beam irradiated ${\beta}-glucan$ may elevate the anti-allergy activity. Therefore, electron beam-irradiated ${\beta}-glucan$ could be used for nutraceutical foods in food industry.