• Title/Summary/Keyword: Radiation tolerance

Search Result 195, Processing Time 0.024 seconds

Frameless Fractionated Stereotactic Radiaton Therapy in Recurrent Head & Neck Cancers (국소재발된 두경부종양의 무고정틀 정위적 분할방사선치료)

  • Kim In-Ah;Choi Ihl-Bhong;Jang Ji-Young;Kang Ki-Mun;Jho Seung-Ho;Kim Hyung-Tae;Lee Kyung-Jin;Choi Chang-Rak
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.156-163
    • /
    • 1998
  • Background & Objectives: Frameless fractionated stereotactic radiotherapy(FFSRT) is a modification of stereotactic radiosurgery(SRS) with radiobiologic advantage of fractionation without losing mechanical accuracy of SRS. Local recurrence of head and neck cancer at or near skull base benefit from reirradiation. Main barrier to successful palliation is dose limitation secondary to normal tissue tolerance. We try to evaluate the efficacy and safety of FFSRT as a new modality of reirradaton in these challenging patients. Materials & Methods: Seven patients with recurrent head & neck cancer involving at or near skull base received FFSRT from September 1995 to November 1997. Six patients with nasopharyngeal cancer had received induction chemotherapy and curative radiation therapy. One patient with maxillary sinus cancer had received total maxillectomy and postoperative radiation therapy as a initial treatment. Follow-up ranged from 11 to 32 months with median of 24 months. Three of 7 patients received hyperfractionated radiation therapy(1.1-1.2Gy/fraction, bid, total 19.8-24Gy) just before FFSRT. All patients received FFSRT(3-5Gy/fraction, total 15-30Gy/5-10fractions). Chemotherapy(cis-platin $100mg/m^2$) were given concurrently with FFSRT in four patients. Second course of FFSRT were given in 4 patients with progression or recurrence after initial FFSRT. Because IF(irregularity factor; ratio of surface area of target to the surface area of sphere with same volume as a target) is too big to use conventional stereotactic RT using multiple arc method for protection of radiation damage to critical normal tissue, all patients received FFSRT with conformal method using irregular static ports. Results: Five of 7 patients showed complete remission in follow-up CT &/or MRI. Three of these five patients who developed marginal, in-field, and out-field recurrences, respectively. Another one of complete responders has been dead of G-I bleeding without evidence of local recurrence. One partial responder who showed progressive disease 15 months after initial FFSRT has received additional FFSRT, and then he is well-being with symptomatic improvement. One minmal responder who showed progression of locoregional disease 9 months after $1^{st}$ FFSRT has received 2nd FFSRT, and then he is alive with stable disease. Five of 7 case had showed direct invasion to skull base and had complaint headache and various symptoms of cranial nerve involvement. Four of these five case showed improvement of neurologic symptoms after FFSRT. No significant neurologic complicaltion related to FFSRT was observed during follow-up periods. Tumor volumes were ranged from 3.9 to 50.7 cc and surface area ranged from 16.1 to $114.9cm^2$. IF ranged from 1.21 to 1.74. The average ratio of volume of prescription isodose shell to target volume was 1.02 that indicated the improvement of target coverage and dose distribution with FFSRT with conformal method compared to target coverage with FFSRT with multiple arc method. Conclusion: Our initial experience suggests that FFSRT with conformal method was relatively effective and safe modality in the treatment of recurrent head and neck cancer involving at or near skull base. Treatment benefit included good palliation of symptoms and reasonable radiographic response. However, more experience and additional follow-up are needed to better assess its ultimate role in treating these challenging patients.

  • PDF

A study on dosimetric comparison of craniospinal irradiation using tomotherpy and reproducibility of position (토모테라피를 이용한 뇌척수조사의 선량적 비교와 자세 재현성에 대한 고찰)

  • Lee, Heejeong;Kim, Jooho;Lee, Sangkyu;Yoon, Jongwon;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.69-76
    • /
    • 2017
  • Purpose: The purpose of this study was to verify dosimetric results and reproducibility of position during craniospinal irradiation (CSI) using tomotherapy (Accuray Incorporated, USA). Also, by comparing with conventional CSI Technique, we confirmed the efficiency of using a Tomotherapy. Materials and Methods: 10 CSI patients who get tomotherapy participate. Patient-specific quality assurances (QA) for each patient are conducted before treatment. When treating, we took Megavoltage Computed Tomography (MVCT) that range of head and neck before treatment, L spine area after treatment. Also we conducted in-vivo dosimetry to check a scalp dose. Finally, we made a 3D conventional radiation therapy(3D-CRT) of those patients to compare dosimetric differences with tomotherapy treatment planning. Results: V107, V95 of brain is 0 %, 97.2 % in tomotherapy, and 0.3 %, 95.1 % in 3D-CRT. In spine, value of V107, V95 is 0.2 %, 18.6 % in tomotherapy and 89.6 %, 69.9 % in 3D-CRT. Except kidney and lung, tomotherapy reduced normal organ doses than 3D-CRT. The maximum positioning error value of X, Y, Z was 10.2 mm, -8.9 mm, -11.9 mm. Through in-vivo dosimetry, the average of scalp dose was 67.8 % of prescription dose. All patient-specific QA were passed by tolerance value. Conclusion: CSI using tomotherapy had a risk of parallel organ such as lung and kidney because of integral dose in low dose area. However, it demonstrated dosimetric superiority at a target and saved normal organ to reduce high dose. Also results of reproducibility were not exceeded margins that estimated treatment planning and invivo dosimetry showed to reduce scalp dose. Therefore, CSI using tomotherapy is considered to efficient method to make up for 3D-CRT.

  • PDF

The variability of 6-D Skull Tracking(6DST) in Cyberknife for Bone metastasis patients (사이버나이프 6-D Skull Tracking의 유용성 평가)

  • Lee, Geon Ho;Bae, Sun Myeong;Song, Heung Kwon;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.41-47
    • /
    • 2018
  • Purpose : The purpose of this study is to evaluate the usefulness of 6 Dimensional Skull Tracking(6DST) in Cyberknife Stereotactic Body Radiation Therapy(SBRT) for the first and second cervical vertebrae(C1 and C2) metastasis. Methode and material : The Computed Tomography (Lightspeed VCT 64, General Electric Co. Waukesha, WI, USA) was used to acquire the CT images of the 9 patients with cervical vertebrae(C1 and C2) metastasis. Treatment plans for Xsight spine tracking and 6 Dimensional skull tracking were established with planning system (Multiplan system Version 4.6, Accuray, US). The results of XST and 6DST for each patient were analyzed with Microsoft Excel 2010. Result : The Maximum offsets of XST for C1 were 0.9 mm in Y(supero-inferior), 0.9 mm in Z(antero-posterior), 0.7 mm in X(left-right) direction, and rotations were and 1.0 degrees roll, 1.0 degrees pitch and 1.2 degrees yaw. The Maximum offsets of 6DST for C1 were 0.7 mm, 0.7 mm, 0.9 mm and $1.0^{\circ}$, $1.0^{\circ}$, $1.2^{\circ}$ for Y, Z, X and Roll, Pitch, Yaw. The Maximum offsets of XST and 6DST for C2 were 0.7 mm, 0.7 mm, 0.8 mm and $0.9^{\circ}$, $1.0^{\circ}$, $1.8^{\circ}$, and 0.9 mm, 0.7 mm, 0.9 mm and $0.9^{\circ}$, $0.9^{\circ}$, $1.0^{\circ}$ for Y, Z, X and Roll, Pitch, Yaw, respectively. Conclusion : XST and 6DST showed identical results for translations and rotations within the tolerance. It is possible to simplify the treatment time and procedure by using the 6DST. Therefore, 6DST is very useful methode with XST among the various tracking methods in Cyberknife for the patients with C1, C2 vertebral metastasis.

  • PDF

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

Evaluation of Dose Distribution of 6 MV X-ray using Optical Dosimetry (광 도시메트리시스템을 이용한 치료용 6 MV X선 선량분포 평가)

  • Kim, Sunghwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.925-932
    • /
    • 2019
  • In this paper, we developed optical dosimetry system with a plastic scintillator, a commercial 50 mm, f1.8 lens, and a commercial high-sensitivity CMOS (complementary metal-oxide semiconductor) camera. And, the correction processors of vignetting, geometrical distortion and scaling were established. Using the developed system, we can measured a percent depth dose, a beam profile and a dose linearity for 6 MV medical LINAC (Linear Accelerator). As results, the optically measured percent depth dose was well matched with the measured percent depth dose by ion-chamber within 2% tolerance. And the determined flatness was 2.8%. We concluded that the optical dosimetry system was sufficient for application of absorbed dose monitoring during radiation therapy.

Fault Tolerant Control of a Servo Manipulator for Teleoperation by Control Allocation to Redundant Joints (여유 자유도에 대한 조종력 배분을 통한 원격작업용 서보 매니퓰레이터의 내고장 제어)

  • 진재현;박병석;안성호;윤지섭
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.4
    • /
    • pp.235-245
    • /
    • 2004
  • In this paper, fault tolerant mechanisms are presented for a servo manipulator system designed to operate in a hot cell. A hot cell is a sealed and shielded room to handle radioactive materials, and it is dangerous for people to work in the hot cell. So, remote operations are necessary to handle the radioactive materials in the hot cell. KAERI has developed a servo manipulator system to perform such remote operations. However, since electric components such as servo motors may fail by radiation, fault tolerant mechanisms have to be considered. For fault tolerance of the servo manipulator system, duplication mechanism increasing the reliability of the transport's driving motors and reconfiguration algorithm accommodating the slave's motor failure have been presented. The reconfiguration algorithm recovering the end effector's motion in spite of one motor's failure is based on control allocation redistributing redundant axes. The constrained optimization method and pseudo inverse method have been adopted for control allocation. Simulation examples and real test results have been presented to verify the Proposed methods.

Fault tolerant design of a Servo Manipulator System for Hot Cell Operation (핫셀용 서보 매니퓰레이터 시스템의 내고장 설계)

  • Jin, Jae-Hyun;Park, Byung-Suk;Ahn, Sung-Ho;Yoon, Ji-Sup;Jung, Jae-Hoo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1464-1469
    • /
    • 2003
  • In this paper, fault tolerant mechanisms are presented for a servo manipulator system designed to operate in a hot cell. A hot cell is a sealed and shielded room to handle radioactive materials, and it is dangerous for people to work in the hot cell. So, remote operations are necessary to handle the radioactive materials in the hot cell. KAERI has developed a servo manipulator system to perform such remote operations. However, since electric components such as servo motors are weakened with radiation, fault tolerant mechanisms have to be considered. For fault tolerance of the servo manipulator system, hardware and software redundancy has been considered. In the case of hardware, radioactive resistant electric components such as cables and connectors have been adopted and motors driving a transport have been duplicated. In case of software, a reconfiguration algorithm accommodating one motor's failure has been developed. The algorithm uses redundant axes to recover the end effector's motion in spite of one motor's failure.

  • PDF

Development of Underwater Acoustic Performance Measurement System Using Pulse Tubes (펄스 튜브를 이용한 수중 음향 성능 측정 시스템 개발)

  • Seo, Yun-Ho;Kim, SangRyul;Lee, Sung-Min;Byun, Yang-Heon;Seo, Youngsoo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.5
    • /
    • pp.399-406
    • /
    • 2014
  • Underwater acoustic materials are installed in order to reduce reflection, transmission and radiation of an underwater structure. The acoustic performance of the materials should be evaluated in accurately-controlled environment in terms of temperature and static pressure. In this paper, two pulse tubes, which are equipped with temperature and pressure controllers, are designed and developed to evaluate echo reduction(ER) and transmission loss(TL) of underwater acoustic materials. The procedures of the evaluation are suggested and the validation is carried out by comparing theoretical values to experimental results for a simple stainless steel specimen and free surface. In result, it is validated that developed pulse tubes are able to measure ER and TL with 2 dB tolerance.

Verification Experiment and Calculation of Heating Load for a Test Space (시험공간에 대한 난방부하 실증실험 및 계산)

  • 현석균;홍희기;유호선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.153-160
    • /
    • 2002
  • As a way to assess the reliability of programs for building energy analysis, verification experiment and calculation of heating load are simultaneously conducted for a well-defined test space. Experimental conditions are carefully set to minimize uncertainties associated with radiation heating, air change, infiltration, and room-to-room interaction. Dyna- mic load calculations using TRNSYS, which are performed for two different computation domains, rely on the energy rate control that represents inherent load characteristics of a space. The predicted instantaneous heating load favorably simulates the overall behavior the measured one, though the latter fluctuates much more rapidly than the former Comparison of the accumulative load between the experiment and calculations shows a close agreement within an engineering tolerance, regardless of the computation model. It is deduced from such findings that the present experimental results along with weather information can serve as a set of reference data for validating load calculation softwares from the users'standpoint. In order to enhance the completeness of this work, a complementary study on the cooling load for the same test space is highly recommended.

AN EXPERIMENTAL STUDY ON THE RADIOSENSITIVITY AND CHEMOSENSITIVITY OF B16 CELL LINE (B16세포주의 방사선 및 항암제감수성에 관한 실험적 연구)

  • Na Seung-Mog;Koh Kawng-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.331-341
    • /
    • 1995
  • The purpose of this study was to aid in the prediction of tumor cell tolerance to radiotherapy and/or chemotherapy. For this study, cell surviving curves were obtained for murine melanoma Bl6 cell line using semiautomated M1T assay. 2,4,6,8, 10Gy were irradiated at a dose rate of 210cGy/min using /sup 60/Co Irradiator ALOORADO 8. After irradiatior, B16 cell lines(2.5×10⁴ cells/ml) were exposed to bleomycin and cisplatin at concentration of 0.2㎍/㎖, 2㎍/㎖ and 20㎍/㎖ for I hour respectively. The viable cells were determined for each radiation dose and/or each concentration of drug. And they were compared to control values. The obtained results were as follows : 1. There was significant difference of surviving fraction at 4, 6, 8, 10Gy on B16 cell line(P<0.05). 2. There was significant difference of cytotoxicity between bleomycin and cisplatin at concentration of 0.2㎍/㎖ and 2㎍/㎖(P<0.05) on B16 cell line, but there was no significant difference of cytotoxicity at concentration of 20㎍/㎖ on B16 cell line. 3. There was significant difference of cytotoxicity of bleomycin after irradiation of 2Gy and 10Gy on B16 cell line(P<0.01). 4. There was significant difference of cytotoxicity of cisplatin at concentration of 20㎍/㎖ after irradiation on B16 cell line.

  • PDF