• 제목/요약/키워드: Radiation therapy Planning

검색결과 499건 처리시간 0.021초

방사성핵종을 이용한 치료에서 흡수선량의 평가 (Internal Radiation Dosimetry in Radionuclide Therapy)

  • 김경민;임상무
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권2호
    • /
    • pp.120-126
    • /
    • 2006
  • Radionuclide therapy has been continued for treatment of incurable diseases for past decades. Relevant evaluation of absorbed dose in radionuclide therapy is important to predict treatment output and essential for making treatment planning to prevent unexpected radiation toxicity. Many scientists in the field related with nuclear medicine have made effort to evolve concept and technique for internal radiation dosimetry in this review, basic concept of internal radiation dosimetry is described and recent progress in method for dosimetry is introduced.

비인강암의 3차원 입체조형치료에서 등가선량분포에 관한 연구 (3-Dimensional Conformal Radiation Therapy in Carcinoma of The Nasopharynx)

  • 금기창;김귀언;이상훈;장세경;임지훈;박원;서창옥
    • Radiation Oncology Journal
    • /
    • 제16권4호
    • /
    • pp.399-408
    • /
    • 1998
  • 목적 : 본 연구는 비인강암 환자의 방사선치료에서 기존의 2차원적 치료계획과 3차원 입체조형 치료계획을 비교 분석하여 3차원적 치료계획의 우월성을 입증하고자 하였다. 대상 및 방법 : 병기가 T4인 환자를 대상으로 하였으며, 두 치료계획 모두 기존의 2차원적 치료방법으로 50.4Gy가 조사된 후 추가조사하는 과정을 2차원적 치료계획과 3차원적 치료계획으로 구분하여 수립하였다. 치료계획의 비교는 선량통계, 선량체적히스토그람, 국소제어율, 그리고 정상조직손상확률을 이용하여 시행하였다. 결과 : 3차원적 치료계획에서 2차원적 치료계획과 비교하여 계획용표적체적의 선량균일성이 더욱 향상되었으며 평균선량도 15.2$\%$의 증가를 보였다. 또한 종양 주위의 정상 장기인 측두엽, 뇌간, 이하선 및 측두하악골관절에 조사되는 평균선량은 3차원적 치료계획에서 낮았다. 종양제어확률은 3차원적 치료계획에서 2차원적 치료계획에서보다도 6$\%$ 증가하였으나 정상조직손상확률은 측두엽, 뇌간, 이하선, 측두하악골관절, 그리고 시신경교차 등 대부분의 정상장기에서 낮았다. 결론 : 3차원 입체조형치료계획은 2차원적 치료계획에 비교하여 종양의 국소제어율을 증가시킬수 있는 우월한 치료법임이 증명되었으나 임상적으로도 같은 결과를 가져올 지는 향후 전향적인 임상 연구가 요구된다.

  • PDF

세기조절방사선치료 시 치료 부위에 따른 치료계획 시스템 간 선량평가 (Dose Evaluation of TPS according to Treatment Sites in IMRT)

  • 김진만;김종식;홍채선;박주영;박수연;주상규
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.181-186
    • /
    • 2013
  • 목 적: 본 연구는 치료계획 시스템인 $Pinnacle^3$ (version 9.2, Philips Medical Systems, USA)과 Eclipse (version 10.0, Varian Medical Systems, USA)을 이용하여 전립선암과 폐암의 세기조절방사선 치료계획시 불균질 부위의 선량 계산 차이를 알고리즘별로 알아보고자 한다. 대상 및 방법: 각 5명의 전립선암 및 폐암 환자를 대상으로, 본원 Protocol에 따른 동일한 조건으로 최적화 계산을 진행하였다. 전립선암 환자의 치료계획은 10 MV, 7Beam을 사용하였으며 2.5 Gy씩 28 fx, 총 70 Gy를 동일 처방하였고, 폐암 환자의 치료계획은 6 MV, 6Beam을 사용하였으며 2 Gy씩 33 fx, 총 66 Gy를 동일 처방하였다. 두 치료계획시스템을 통해 CTV, PTV 및 종양주위의 OAR의 최대선량, 평균선량, 최소선량을 비교하였다. 결 과: 전립선암에서 두 치료계획시스템 모두 CTV와 PTV의 선량변화가 2%이내였으며 종양주변 정상 장기(방광, 대퇴골, 직장)도 선량제약조건을 충족하였다. 폐암에서도 CTV와 PTV는 2%이내의 선량변화를 보였고, 정상 장기(식도, 척수, 양측 폐)도 선량제약 조건을 충족하였다. 하지만, Eclipse 치료계획의 최소선량은 CTV에서 1.9%, PTV에서 3.5% 높았고 양측 폐의 경우 V5 Gy에서 3.0% 높은 차이를 보였다. 결 론: 치료부위에 따른 각각의 치료계획시스템은 본원의 선량제한 조건을 모두 만족하여 임상적 정확성을 확인할 수 있었다. 향후 다양한 부위의 치료계획 연구와 치료계획시스템의 적용은 보다 정확한 치료계획을 위한 방법을 제시할 것이라 사료된다.

  • PDF

가임기 여성의 방사선 치료 시 난소 선량 평가 (Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy)

  • 박성준;이영철;김선명;김영범
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.145-153
    • /
    • 2021
  • 목 적: 본 연구에서는 가임기 여성의 유방암 방사선 치료 시 난소 선량에 대해 실험을 통하여 평가해보고자 한다. 치료기법에 따른 치료계획시스템에서 계산된 선량과 열형광선량계를 이용한 측정선량을 비교·분석하여 난소 선량을 평가하고 납(Pb) 앞치마의 사용유무에 따른 선량 분석을 통해 임상에서의 유용성을 알아보고자 한다. 대상 및 방법: 측정에는 Rando humanoid phantom을 이용하였고, 치료기법으로는 쐐기필터치료기법, 3차원 입체조형치료, 세기변조방사선치료를 사용하였다. CT simulator를 이용하여 얻은 Rando humanoid phantom 3D 영상의 우측 유방에 처방선량의 95%가 전달될 수 있도록 치료계획을 세웠고, TLD를 Rando hunmanoid phantom의 가상 표적의 표면 및 심부에 삽입하고 방사선을 조사하였다. 측정위치는 치료 중심점과 Rando humanoid phantom의 정중앙을 중심으로 반대쪽 유방으로 2cm 이동한 지점과 치료 중심축 및 하방으로 우측 유방의 경계면에서 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm, 우측 난소 위치의 표면과 중심점을 포함하여 총 9개 지점에서 측정하였다. 치료계획시스템의 선량 비교에서는 쐐기필터치료기법 2가지와 3차원 입체조형치료, 세기변조방사선치료 등 총 4개의 치료 계획을 수립하여 비교하였다. 그리고 TLD를 이용한 측정값 비교는 세기변조방사선치료와 쐐기필터를 이용한 치료를 비교하였고, 납 앞치마의 사용유무에 따라서 세기변조방사선치료의 선량차이를 측정하여 비교·분석하였다. 측정값은 각 포인트마다 3개의 TLD값 평균을 내고 TLD 교정값을 이용하여 환산하였으며 이를 Point dose mean값으로 계산하였다. 치료계획값과 실제 측정값을 비교하기 위해 각 지점마다 절대선량값을 측정하여 %Diff 값으로 계산하였다. 결 과: 치료 중심점인 Point A에서는 치료계획시스템에서 최대 201.7cGy가 나왔고, 실제 TLD 측정값은 최대 200.6cGy가 나왔다. 모든 치료계획시스템에서 유방 경계면으로부터 하방으로 17.5cm 떨어진 지점인 Point G 부터는 0cGy로 계산이 되었다. 실제 TLD 측정 결과 Point G에서는 최대 2.6cGy가 나왔고, 난소선량인 Point J에서는 최대 0.9cGy로 나타났으며 %Diff값은 0.3%~1.3%였다. 납 앞치마의 사용유무에 따른 선량 차이는 최대 2.1cGy에서 최소 0.1cGy로 나타났으며 %Diff값은 0.1%~1.1%였다. 결 론: 치료계획시스템에서 3가지 치료계획에 따른 선량차이는 최저 0.85%에서 최고 2.45%로 큰 격차를 보이지 않았다. 난소에서 Rando humanoid phantom의 치료계획과 실제 측정한 선량차이는 0.9% 이내로 나타났으나 실제 측정에서 조금 더 높게 측정되었다. 이는 치료계획시스템에서 산란선의 영향을 정확하게 반영하지 못하였고, 실제 측정에서는 TLD를 삽입한 상태로 CBCT를 촬영한 선량과 산란선량이 반영된 것으로 사료된다. 납 앞치마의 유무에 따른 선량측정에서 납 앞치마를 사용했을 경우에 치료범위에서 가까운 거리일수록 차폐의 효과가 있었으며, 치료범위에서 15cm 이상 거리가 있는 경우에는 거의 영향을 미치지 않는 것으로 나타났다. 임상적으로 방사선 치료 중에는 임신이나 인공수정을 하기에는 적절하지 않지만, 치료 중 난소에 조사된 선량은 방사선 치료 후 가임기 여성의 생식 기능에 크게 영향을 주지 않을 것으로 생각된다. 하지만 가임 여성의 경우에는 지속적인 불안감을 가지고 있으므로 이번 결과를 통한 데이터를 제시함으로써 심리적인 안정을 도모할 수 있을 것으로 사료된다.

Management for locally advanced cervical cancer: new trends and controversial issues

  • Cho, Oyeon;Chun, Mison
    • Radiation Oncology Journal
    • /
    • 제36권4호
    • /
    • pp.254-264
    • /
    • 2018
  • This article reviewed new trends and controversial issues, including the intensification of chemotherapy and recent brachytherapy (BT) advances, and also reviewed recent consensuses from different societies on the management of locally advanced cervical cancer (LACC). Intensive chemotherapy during and after radiation therapy (RT) was not recommended as a standard treatment due to severe toxicities reported by several studies. The use of positron emission tomography-computed tomography (PET-CT) and magnetic resonance imaging (MRI) for pelvic RT planning has increased the clinical utilization of intensity-modulated radiation therapy (IMRT) for the evaluation of pelvic lymph node metastasis and pelvic bone marrow. Recent RT techniques for LACC patients mainly aim to minimize toxicities by sparing the normal bladder and rectum tissues and shortening the overall treatment time by administering a simultaneous integrated boost for metastatic pelvic lymph node in pelvic IMRT followed by MRI-based image guided adaptive BT.

Radiation Induced Lung Injury: Prediction, Assessment and Management

  • Giridhar, Prashanth;Mallick, Supriya;Rath, Goura Kishore;Julka, Pramod Kumar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권7호
    • /
    • pp.2613-2617
    • /
    • 2015
  • Radiation induced lung injury has long been considered a treatment limiting factor for patients requiring thoracic radiation. This radiation induced lung injury happens early as well as late. Radiation induced lung injury can occur in two phases viz. early (< 6 months) when it is called radiation pneumonitis and late (>6 months) when it is called radiation induced lung fibrosis. There are multiple factors that can be patient, disease or treatment related that predict the incidence and severity of radiation pneumonitis. Radiation induced damage to the type I pneumocytes is the triggering factor to initiate such reactions. Over the years, radiation therapy has witnessed a paradigm shift in radiation planning and delivery and successfully reduced the incidence of lung injury. Radiation pneumonitis is usually a diagnosis of exclusion. Steroids, ACE inhibitors and pentoxyphylline constitute the cornerstone of therapy. Radiation induced lung fibrosis is another challenging aspect. The pathophysiology of radiation fibrosis includes continuing inflammation and microvascular changes due to pro-angiogenic and profibrogenic stimuli resembling those in adult bronchiectasis. General supportive management, mobilization of airway secretions, anti-inflammatory therapy and management of acute exacerbations remains the treatment option. Radiation induced lung injury is an inevitable accompaniment of thoracic radiation.

Discrepancies in Dose-volume Histograms Generated from Different Treatment Planning Systems

  • Kim, Jung-in;Han, Ji Hye;Choi, Chang Heon;An, Hyun Joon;Wu, Hong-Gyun;Park, Jong Min
    • Journal of Radiation Protection and Research
    • /
    • 제43권2호
    • /
    • pp.59-65
    • /
    • 2018
  • Background: We analyzed changes in the doses, structure volumes, and dose-volume histograms (DVHs) when data were transferred from one commercial treatment planning system (TPS) to another commercial TPS. Materials and Methods: A total of 22 volumetric modulated arc therapy (VMAT) plans for nasopharyngeal cancer were generated with the Eclipse system using 6-MV photon beams. The computed tomography (CT) images, dose distributions, and structure information, including the planning target volume (PTV) and organs at risk (OARs), were transferred from the Eclipse to the MRIdian system in digital imaging and communications in medicine (DICOM) format. Thereafter, DVHs of the OARs and PTVs were generated in the MRIdian system. The structure volumes, dose distributions, and DVHs were compared between the MRIdian and Eclipse systems. Results and Discussion: The dose differences between the two systems were negligible (average matching ratio for every voxel with a 0.1% dose difference criterion = $100.0{\pm}0.0%$). However, the structure volumes significantly differed between the MRIdian and Eclipse systems (volume differences of $743.21{\pm}461.91%$ for the optic chiasm and $8.98{\pm}1.98%$ for the PTV). Compared to the Eclipse system, the MRIdian system generally overestimated the structure volumes (all, p < 0.001). The DVHs that were plotted using the relative structure volumes exhibited small differences between the MRIdian and Eclipse systems. In contrast, the DVHs that were plotted using the absolute structure volumes showed large differences between the two TPSs. Conclusion: DVH interpretation between two TPSs should be performed using DVHs plotted with the absolute dose and absolute volume, rather than the relative values.

코발트60 원격치료기에 대한 Semiuniversal Wedge Filter의 제작과 임상응용 (Construction of Semi-universal Wedge Filter and Clinical Application for Co-60 Teletherapy Unit)

  • 김명호;윤석록;신동오
    • 대한방사선치료학회지
    • /
    • 제3권1호
    • /
    • pp.45-50
    • /
    • 1989
  • 고 에너지 방사선으로 용적이 적은 표재성 종양 및 부정형의 체표면과 경사진 조사야에 대한 방사선 치료시 종양 용적내에 균등한 선량분포를 얻기 위해서 Wedge filter 기법이 많이 사용되고 있다. 본 연구의 목적은 코발트 $60{\Gamma}$선 치료를 위한 Semi-Universal Wedge filter의 제작과 임의의 조사야에 대한 최적한 출력 및 정확한 조작방법을 기술하고 방사선 치료계획의 최적화를 기하기 위해서 Wedge filter의 임상응용 방법을 제시하고자 한다.

  • PDF