• Title/Summary/Keyword: Radiation survey

Search Result 419, Processing Time 0.029 seconds

The survey of the surface doses of the dental x-ray machines (치과 방사선 촬영기의 표면선량 변화)

  • Lee Jae-Seo;Kang Byung-Cheol;Yoon Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.35 no.2
    • /
    • pp.87-90
    • /
    • 2005
  • Purpose : The purpose of this study was to investigate variability of doses with same exposure parameters and evaluate radiographic density according to the variability of doses. Materials and methods Twenty-eight MAX-GLS (Shinhung Co, Seoul, Korea), twenty-one D-60-5 (DongSeo Med, Seoul, Korea), and eleven REX-601 (Yoshida Dental MFG, Tokyo, Japan) dental x-ray machines were selected for this study Surface doses were measured under selected combinations of tube voltage, tube current, exposure time, and constant distance 42 cm from the focal spot to the surface of the Multi-O-meter (Unfors Instruments, Billdal, Sweden). Radiographic densities were measured on the films at maximum, minimum and mean surface doses of each brand of x-ray units. Results With MAX-GLS, the maximum surface doses were thirteen to fourteen times as much as the minimum surface doses. With D-60-S, the maximum surface doses were three to eight times as much as the minimum surface doses. With REX-601, the maximum surface doses were six to ten times as much as the minimum surface doses. The differences in radiographic densities among maximum, mean, and minimum doses were significant (p<0.01). Conclusion : The surface exposure doses of each x-ray machine at the same exposure parameters were different within the same manufacturer's machines.

  • PDF

Optimum Collector Area and Economic Evaluation for the Greenhouse Heating (태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가)

  • Pak, Ee-Tong;Kim, Kyu-In
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF

Establishment of Standard of Property Control for Angiographic Equipments (혈관조영장비의 성능관리 기준개발)

  • 임현수;김부길
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.6
    • /
    • pp.61-66
    • /
    • 2004
  • To make a guide line of property control of angiography equipments, we made standard evaluation sheet forms of facility and management of angiography suite, physical properties of angiography equipments, and image quality of film and then surveyed them at 29 hospital nationwide. Survey and development of standard evaluation sheet form of physical properties of angiography equipments. By using resolution & radiation dose, physical properties of angiography equipments of 49 in number nationwide were evaluated. Most of them (91%) had good performance.

Analysis of health inequality by the type of employment on health among employees - Pathway of the effect via the exposure of hazardous factors - (임금근로자의 고용형태에 따른 건강수준의 차이 분석 - 유해위험요인 노출을 경유한 영향 경로 -)

  • Rhee, Kyung Yong
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.81-90
    • /
    • 2014
  • Flexible production system has been expanded to all sectors of economy with the change of labor market and diversification of employment. The unstable employment with irregular work has replaced stable employment with regular work. This study has investigate the impact pathway of the type of employment on health status especially ill-health symptoms experiences. Among the first Korean Working Conditions Survey data, the employee's response data was used to analyze the path way with multiple regression analysis. The result has shown the direct effect of the type of employment on ill-health symptoms experience. Indirect effect of the type of employment was found the pathway via the exposure to noise, high temperature, low temperature, dust, skin contact to chemicals, painful posture, heavy material handling, standing position, repetitive movement of hands. However the exposure to the other hazardous factors such as organic solvent, wholebody vibration, radiation, lifting people, infectious materials were not influenced by the type of employment.

MASSIVE BLACK HOLE EVOLUTION IN RADIO-LOUD ACTIVE GALACTIC NUCLEI

  • FLETCHER ANDRE B.
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.3
    • /
    • pp.177-187
    • /
    • 2003
  • Active galactic nuclei (AGNs) are distant, powerful sources of radiation over the entire electromagnetic spectrum, from radio waves to gamma-rays. There is much evidence that they are driven by gravitational accretion of stars, dust, and gas, onto central massive black holes (MBHs) imprisoning anywhere from $\~$1 to $\~$10,000 million solar masses; such objects may naturally form in the centers of galaxies during their normal dynamical evolution. A small fraction of AGNs, of the radio-loud type (RLAGNs), are somehow able to generate powerful synchrotron-emitting structures (cores, jets, lobes) with sizes ranging from pc to Mpc. A brief summary of AGN observations and theories is given, with an emphasis on RLAGNs. Preliminary results from the imaging of 10000 extragalactic radio sources observed in the MITVLA snapshot survey, and from a new analytic theory of the time-variable power output from Kerr black hole magnetospheres, are presented. To better understand the complex physical processes within the central engines of AGNs, it is important to confront the observations with theories, from the viewpoint of analyzing the time-variable behaviours of AGNs - which have been recorded over both 'short' human ($10^0-10^9\;s$) and 'long' cosmic ($10^{13} - 10^{17}\;s$) timescales. Some key ingredients of a basic mathematical formalism are outlined, which may help in building detailed Monte-Carlo models of evolving AGN populations; such numerical calculations should be potentially important tools for useful interpretation of the large amounts of statistical data now publicly available for both AGNs and RLAGNs.

A Study on the Required Specification for the Development of Low Earth Orbit Meteorological Satellite Payload (저궤도 기상위성 탑재체 개발을 위한 요구 규격 연구)

  • Eun, Jong Won
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.2
    • /
    • pp.74-79
    • /
    • 2013
  • For the purpose of drawing out a requirements (draft) for the development of low Earth orbit meteorological satellite payload, the present development situation of the foreign low Earth orbit meteorological satellite payload was analyzed, and survey and analysis on the questionnaire of the low Earth orbit meteorological satellite payload users' requirements were carried out. Through this research, some key required performance specifications (draft) were made on the basis of technological requirements such as frequency, radiation measurement, spacial, and antenna efficiency requirements, and the low Earth orbit meteorological satellite payload users' requirements.

Radiative Transfer Modeling of EC 53: An Episodically Accreting Class I Young Stellar Object

  • Baek, Giseon;MacFarlane, Benjamin A.;Lee, Jeong-Eun;Stamatellos, Dimitris;Herczeg, Gregory;Johnstone, Doug;Chen, Huei-Ru Vivien;Kang, Sung-Ju
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.67.1-67.1
    • /
    • 2019
  • We present 2-dimensional continuum radiative transfer modeling for EC53. EC 53 is a Class I YSO, which was brightened at $850{\mu}m$ by a factor of 1.5. This luminosity variation was revealed by the JCMT Transient Survey. The increase in brightness is likely related to the enhanced accretion. We aim to investigate how much increase of protostellar luminosity causes the observed brightness increase at $850{\mu}m$. Thus we modeled the SED of EC 53 both in the quiescence and (small scale) outburst phases, with and without the external heating from the interstellar radiation field (ISRF). We found that the internal protostellar luminosity should increase more to fit the observed flux enhancement if the ISRF is considered in the model.

  • PDF

Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose (유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사)

  • Park, Hye-Suk;Kim, Ye-Seul;Kim, Sang-Tae;Park, Ok-Seob;Jeon, Chang-Woo;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.163-171
    • /
    • 2011
  • The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kVp in 10 kVp increments at the FDD of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at the same effective dose. The results showed that the eDQE was largest at 60 kVp when compares the eDQE at different tube voltage. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF). However, most of major hospitals in Korea employed a short FDD of 100 cm with an anti-scatter grid for the chest radiological examination of a 15 month old infant. As a result, the entrance surface air kerma (ESAK) values for the hospitals of this survey exceeded the Korean DRL (diagnostic reference level) of $100{\mu}Gy$. Therefore, appropriate technical parameters should be established to perform pediatric chest examinations on children of different ages. The results of this study may serve as a baseline to establish detailed reference level of pediatric dose for different ages.

Korean Practice Guidelines for Gastric Cancer 2022: An Evidence-based, Multidisciplinary Approach

  • Tae-Han Kim;In-Ho Kim;Seung Joo Kang;Miyoung Choi;Baek-Hui Kim;Bang Wool Eom;Bum Jun Kim;Byung-Hoon Min;Chang In Choi;Cheol Min Shin;Chung Hyun Tae;Chung sik Gong;Dong Jin Kim;Arthur Eung-Hyuck Cho;Eun Jeong Gong;Geum Jong Song;Hyeon-Su Im;Hye Seong Ahn;Hyun Lim;Hyung-Don Kim;Jae-Joon Kim;Jeong Il Yu;Jeong Won Lee;Ji Yeon Park;Jwa Hoon Kim;Kyoung Doo Song;Minkyu Jung;Mi Ran Jung;Sang-Yong Son;Shin-Hoo Park;Soo Jin Kim;Sung Hak Lee;Tae-Yong Kim;Woo Kyun Bae;Woong Sub Koom;Yeseob Jee;Yoo Min Kim;Yoonjin Kwak;Young Suk Park;Hye Sook Han;Su Youn Nam;Seong-Ho Kong;The Development Working Group for the Korean Practice Guidelines for Gastric Cancer 2022 Task Force Team
    • Journal of Gastric Cancer
    • /
    • v.23 no.1
    • /
    • pp.3-106
    • /
    • 2023
  • Gastric cancer is one of the most common cancers in Korea and the world. Since 2004, this is the 4th gastric cancer guideline published in Korea which is the revised version of previous evidence-based approach in 2018. Current guideline is a collaborative work of the interdisciplinary working group including experts in the field of gastric surgery, gastroenterology, endoscopy, medical oncology, abdominal radiology, pathology, nuclear medicine, radiation oncology and guideline development methodology. Total of 33 key questions were updated or proposed after a collaborative review by the working group and 40 statements were developed according to the systematic review using the MEDLINE, Embase, Cochrane Library and KoreaMed database. The level of evidence and the grading of recommendations were categorized according to the Grading of Recommendations, Assessment, Development and Evaluation proposition. Evidence level, benefit, harm, and clinical applicability was considered as the significant factors for recommendation. The working group reviewed recommendations and discussed for consensus. In the earlier part, general consideration discusses screening, diagnosis and staging of endoscopy, pathology, radiology, and nuclear medicine. Flowchart is depicted with statements which is supported by meta-analysis and references. Since clinical trial and systematic review was not suitable for postoperative oncologic and nutritional follow-up, working group agreed to conduct a nationwide survey investigating the clinical practice of all tertiary or general hospitals in Korea. The purpose of this survey was to provide baseline information on follow up. Herein we present a multidisciplinary-evidence based gastric cancer guideline.

Analysis of the Necessity of Medical Records Related to Radiological Examination (방사선검사의 의무기록에 관한 요구도 분석)

  • Hong, Dong-Hee;Lim, Cheong-Hwan;Lim, Woo-Taek;Joo, Young-Cheol;Jung, Hong-Ryang;Kim, Eun-Hye;Yoon, Yong-Su;Jung, Young-Jin;Choi, Ji-Won;Jeong, Sung-Hun;Park, Myeong-Hwan;Yang, Oh-Nam;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.513-523
    • /
    • 2021
  • The purpose of this study was to discuss the required items and feasibility of medical records of radiological examinations performed by radiological technologists at medical institutions. An online survey was conducted to a total of 10,000 radiation-related workers, of which 1,026 (10.3%) responded. As a research method, self-made questionnaires were used. The online survey was conducted from September 10 to September 20, 2021 for the survey period. For response data, a Chi-square test was performed according to demographic characteristics using SPSS 27.0 version (IBM Inc., Chicago, Ill, USA), and it was judged to be significant when the P value was less than 0.05. The reliability of the questionnaire response was found to be Chronbach α=0.933. More than 90% of the medical records related to radiological examinations are necessary, and they answered that a curriculum, remuneration curriculum, and legal system for medical records should be prepared. More than 90% of the respondents agreed with the proposal of the Radiological Technologist Independent Act for legal preparation, and most of the information required for medical records is currently recorded in DICOM images. According to the demographic characteristics, the medical record requirement for radiological examination, curriculum, continuing education, and legislation were found to be higher with higher education and higher with longer working experience. In addition, most of the radiology departments showed a high demand for medical records, so most of them responded positively to the medical records requirements for radiological examinations. This study analyzed the medical record requirements for radiological examinations, and as shown in the results, medical record requirements for radiological examinations was found that most radiological technologists felt need for the new law and supported it. In addition, if the information recorded in the DICOM image is used, it is considered that medical records could be easily prepared without additional work by the radiological technologists.