• 제목/요약/키워드: Radiation spectrum

검색결과 504건 처리시간 0.023초

Comparison of Environmental Radiation Survey Analysis Results in a High Dose Rate Environment Using CZT, NaI(Tl), and LaBr3(Ce) Detectors

  • Sungyeop Joung;Wanook Ji;Eunjung Lee;Young-Yong Ji;Yoomi Choi
    • 방사성폐기물학회지
    • /
    • 제21권4호
    • /
    • pp.543-558
    • /
    • 2023
  • Currently, Japan is undertaking a nationwide project to measure and map radioactive contamination around Fukushima, as part of the efforts to restore normalcy following the nuclear accident. The Japan Atomic Energy Agency (JAEA) manages the Fukushima Environmental Safety Center, located approximately 20 km north of the Fukushima Daiichi nuclear power plant in Minamisōma City, Fukushima Prefecture. In collaboration with the JAEA, this study involved conducting comparison experiments and analyses with radiation detectors in high radiation environments, a challenging task in Korean environments. Environmental radiation surveys were conducted using three types of detectors: CZT, NaI(Tl), and LaBr3(Ce), across two contaminated areas. Dose rate values were converted using dose rate conversion factors for each detector type, and dose rate maps were subsequently created and compared. The detectors yielded similar results, demonstrating their feasibility and reliability in high radiation environments. The findings of this study are expected to be a crucial reference for enhancing the verification and supplementation of procedures and methods in future radiation measurements and mobile surveys in high-radiation environments, using these three types of radiation instruments.

A Spread Spectrum Clock Generator for SATA II with Rounded Hershey-Kiss Modulation Profile

  • Moon, Yong-Hwan;Lim, Wan-Sik;Kim, Tae-Ho;Kang, Jin-Ku
    • 전기전자학회논문지
    • /
    • 제15권2호
    • /
    • pp.129-133
    • /
    • 2011
  • A spread spectrum clock generation is an efficient way to reduce electro-magnetic interference (EMI) radiation in modern mixed signal chip systems. The proposed circuit generates the spread spectrum clock by directly injecting the modulation voltage into the voltage-controlled oscillator (VCO) current source for SATA II. The resulting 33KHz modulation profile has a Hersey-Kiss shape with a rounded peak. The chip has been fabricated using $0.18{\mu}m$ CMOS process and test results show that the proposed circuit achieves 0.509% (5090ppm) down spreading at 1.5GHz and peak power reduction of 10dB. The active chip area is 0.36mm ${\times}$ 0.49mm and the chip consumes 30mW power at 1.5GHz.

Laplace transform 방법에 의한 x-ray의 에너지 스펙트럼 추정 (Estimated spectrum of a 6MV X-ray)

  • Yoo, Myung-Jin
    • 한국의학물리학회지:의학물리
    • /
    • 제4권2호
    • /
    • pp.37-47
    • /
    • 1993
  • Jones 모델 및 HKB모델을 이용하여 Laplace transform방법으로 6MV X-ray의 대략적인 에너지 스펙트럼을 분석하였다. Jones모델은 투과계수 0.1이하에서는 Laplace transform방법이 적용될 수 없는 심한 제약을 받는다는 것을 알 수 있었다. HKB모델에 의한 에너지 스펙트럼은 대체로 실제의 에너지 스펙트럼과 일치하는 형태를 나타내지만 6MeV에너지 이상의 영역에서 길게 꼬리를 이루는 단점이 있었다.

  • PDF

Angular Spectrum of the Spontaneous Emission from Dye Molecules Near a Boundary

  • Choi, Hyun-Ho;Kim, Hyoung-Joo;Noh, Jae-Woo;Park, Dae-Yoon;Jhe, Won-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제6권1호
    • /
    • pp.1-4
    • /
    • 2002
  • We studied experimentally the angular spectrum of the light emitted from dye Molecules near a plane boundary. It is confirmed that the molecules near the boundary can emit light into the evanescent wave mode, and the light emission with the angle greater than the critical angle is detected with good accuracy. The angular spectrum of the spontaneous radiation is measured, and the spectrum shows contributions from the molecules both near and far away from the boundary. The polarization dependence and the pumping angle dependence are also measured. The experimental results are in good agreement with quantum theory.

X-선 스펙트럼 변조 기술 연구 (X-Ray Spectrum Modulation for Mammography)

  • 김광현;김경락;오창현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.600-603
    • /
    • 2003
  • Energy spectrum modulation of X-ray source in digital mammography has been studied. In this study, we calculated various filtered spectra using the scattering data. Primary spectra were generated by Molybdenum (Mo) and Tungsten (W) targets. The materials of added filters are Molybdenum and Rhodium (Rh) for 40 kVp Mo. primary spectrum, the amounts of photons over whole energy ranges are attenuated to 0.43 with 0.03 mm Mo filter and 0.38 with 0.06 mm Mo filter while the photons of energy ranged from 17 keV to 20 keV. The photons of low energy ranged below 17 keV are considerably attenuated. This effect brings out reducing the scattered radiation and dose to the patient, and enhancing subject contrast in the image. The results show that filtered spectra are not seriously affected by X-ray tube loadability. Because the energy range from 17 keV to 20 keV is directly transmitted although low and high energies are mainly filtered.

  • PDF

Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator

  • Lee, Hyun Cheol;Koo, Bon Tack;Choi, Chang Il;Park, Chang Su;Kwon, Jeongwan;Kim, Hong-Suk;Chung, Heejun;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • 제45권3호
    • /
    • pp.117-129
    • /
    • 2020
  • Background: Radiation portal monitors (RPMs) involving plastic scintillators installed at the border inspection sites can detect illicit trafficking of radioactive sources in cargo containers within seconds. However, RPMs may generate false alarms because of the naturally occurring radioactive materials. To manage these false alarms, we previously suggested an energy-weighted algorithm that emphasizes the Compton-edge area as an outstanding peak. This study intends to evaluate the identification of radioactive sources using an improved energy-weighted algorithm. Materials and Methods: The algorithm was modified by increasing the energy weighting factor, and different peak combinations of the energy-weighted spectra were tested for source identification. A commercialized RPM system was used to measure the energy-weighted spectra. The RPM comprised two large plastic scintillators with dimensions of 174 × 29 × 7 ㎤ facing each other at a distance of 4.6 m. In addition, the in-house-fabricated signal processing boards were connected to collect the signal converted into a spectrum. Further, the spectra from eight radioactive sources, including special nuclear materials (SNMs), which were set in motion using a linear motion system (LMS) and a cargo truck, were estimated to identify the source identification rate. Results and Discussion: Each energy-weighted spectrum exhibited a specific peak location, although high statistical fluctuation errors could be observed in the spectrum with the increasing source speed. In particular, 137Cs and 60Co in motion were identified completely (100%) at speeds of 5 and 10 km/hr. Further, SNMs, which trigger the RPM alarm, were identified approximately 80% of the time at both the aforementioned speeds. Conclusion: Using the modified energy-weighted algorithm, several characteristics of the energy weighted spectra could be observed when the used sources were in motion and when the geometric efficiency was low. In particular, the discrimination between 60Co and 40K, which triggers false alarms at the primary inspection sites, can be improved using the proposed algorithm.

기준 베타선장의 에너지 스펙트럼 측정 (The Measurement of National Standard ${\beta}$-Rays Energy Spectrum)

  • 김철항;이철영;김현문;하석호;전국진
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.285-291
    • /
    • 2012
  • Si(Li) 검출기를 이용해 한국표준과학연구원에서 보유한 베타선 선원인 $^{147}Pm$, $^{85}Kr$, $^{90}Sr+^{90}Y$ 선원의 순수 베타선 에너지 스펙트럼을 측정하였고 이 측정 스펙트럼에 대한 잔여에너지와 질량충돌저지능비를 산출하였다. 베타선의 잔여에너지는 $^{147}Pm$, $^{85}Kr$, $^{90}Sr+^{90}Y$ 선원에 대하여 각각 0.14, 0.57, 0.93 MeV으로 평가되었고 질량충돌저지능비는 각각 1.123, 1.120, 1.109이었다.

방사선 포털 모니터용 대용적 플라스틱 섬광체 내부 빛 수집 효율 평가 (Light Collection Efficiency of Large-volume Plastic Scintillator for Radiation Portal Monitor)

  • 이진형;김종범
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.157-165
    • /
    • 2017
  • In this paper, we calculate the light photons collection efficiency of large-volume plastic scintillation detector mainly used for radiation portal monitor (RPM). A Monte Carlo light photon transport code, DETECT2000, were used to quantitatively evaluate light collection efficiency of plastic scintillation detector. DETECT2000 calculated the placement of light collection efficiency based on the energy spectrum. We calculated the light collection efficiency relative to the position of the energy spectrum that proportional to the placement of the source. The $850{\times}285{\times}65mm^3$ size of polyvinyl toluene (PVT) scintillator was used for measurements. Through DETECT2000 simulation, the light collection efficiency of $5{\times}5$ arrays were calculated and verification was performed by comparing with experimentally measured. And then, the corrected MCNP simulation by applying the light collection efficiency in $21{\times}13$ arrays was compared and analyzed. Comparing the Monte Carlo simulation with measured results, it shows an average difference of 10.1% in $5{\times}5$ arrays. Particularly, about twice of the difference was found in the edge of first column, which coupled with PMT. In whole $5{\times}5$ array, the overall ratio was the same except for the first column. And then comparing the energy spectra of the $21{\times}13$ array with and without the light collection efficiency, it shows a difference of 6.69% in Compton edge area. The DETECT2000 based light collection efficiency simulation showed well agreement with the point source experiment. And comparing with measured energy spectra, we could compare the differences according to whether or not the light collection efficiency was applied. As a results, it is possible to increase the accuracy and reliability of Monte Carlo simulation results by pre-calculating the light collection efficiency according to the PVT geometry by using the DETECT2000.

간접평판형 검출기에서 국제전자기술위원회 기준을 통한 잡음전력스펙트럼 비교 연구 (Comparison of Noise Power Spectrum in Measurements by Using International Electro-technical Commission Standard Devices in Indirect Digital Radiography)

  • 민정환;정회원;김기원;권경태;정재용;손진현;김현수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.457-462
    • /
    • 2018
  • The purpose of this study was to compare image quality of indirect digital radiography (IDR) system using the International Electro-technical Commission standard (IEC 62220-1), and to suggest the analysis of noise power spectrum (NPS) which were applied to IEC 62220-1 in medical imaging. In this study, Pixium 4600 (Trixell, France) which is indirect flat panel detector (FPD) was used. The size of image receptor (IR) is $7{\times}17$ inch (matrix $3001{\times}3001$) which performed 14bit processing and pixel pitch is $143{\mu}m$. In IEC standard, NPS evaluation were applied to RQA3, RQA5, RQA7 and RQA9. Because of different radiation quality, each region of interesting (ROI) were compared. The results of NPS indicated up to $3.5mm^{-1}$ including low Nyquist frequency. RQA5 indicated the lowest NPS and the others indicated higher NPS results relatively. NPS result of ROI a38 was higher than ROI a92 and this result indicated that there are more noise in left (cathode) than right (anode). This study were to evaluate NPS by using different radiation quality and setting the each ROI, and to suggest the quantitative methods of measuring NPS.

전자스핀공명법(ESR)을 이용한 방사선조사 조제유류의 판별 (Detection of Irradiated Milk Formulas using Electron Spin Resonance)

  • 운재호;박병룡;최병국;김나영;정홍점;정기수;김희선;김창섭
    • Journal of Dairy Science and Biotechnology
    • /
    • 제28권2호
    • /
    • pp.13-18
    • /
    • 2010
  • 방사선 조사된 완제품 조제분유를 포함한 시료 4종의 ESR 스펙트럼 특성을 측정하였다. 조제분유와 전지분유의 비조사 시료는 g=2.0050의 아주 약한 singlet 형태의 스펙트럼을 나타내었다. 조사 시료에서 전지분유는 g=2.0050의 singlet 형태의 스펙트럼, 조제분유는 전지분유와 같은 중심 피크 옆에 g=2.0006의 작은 피크를 가진 비대칭 형태의 스펙트럼을 나타내었고, 두 시료 모두 비조사 시료와 조사 시료의 신호 세기 차이가 명확하여 조사유무 판별이 가능하였다. 포도당과 유당의 비조사 시료는 아무런 시그널을 나타내지 않았으며, 조사 시료는 이미 알려져 있는 결정형 당 유래의 다형 피크를 가진 스펙트럼을 나타내었다. 선량이 증가함에 따라 신호 세기도 증가하였고, 회귀방정식의 상관계수는 0.95 이상의 높은 값을 나타내었다. 감마선과 전자선 조사에 의한 ESR 스팩트럼 간의 유의성 있는 차이는 없는 것으로 확인되었다. 결론적으로 본 실험을 통하여 ESR 분석은 방사선 조사된 조제분유 및 원료의 판별에 유용한 방법으로 적용될 수 있는 것으로 판단되었으며, 온도, 습도 및 전처리 조건 등의 요인에 의한 변화 가능성과 식품 생산 및 장기유통 기간 등을 고려할 때 이에 대한 지속적인 연구와 자료 축적이 요구된다고 할 것이다.

  • PDF