• Title/Summary/Keyword: Radiation spectrum

Search Result 511, Processing Time 0.028 seconds

Observation of the Cosmic Near-Infrared Background with the CIBER rocket

  • Kim, Min-Gyu;Matsumoto, T.;Lee, Hyung-Mok;Arai, T.;Battle, J.;Bock, J.;Brown, S.;Cooray, A.;Hristov, V.;Keating, B.;Korngut, P.;Lee, Dae-Hee;Levenson, L.R.;Lykke, K.;Mason, P.;Matsuura, S.;Nam, U.W.;Renbarger, T.;Smith, A.;Sullivan, I.;Wada, T.;Zemcov, M.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.42-42
    • /
    • 2012
  • The First stars (Pop.III stars) in the universe are expected to be formed between the recombination era at z - 1100 and the most distant quasar (z - 8). They have never been directly detected due to its faintness so far, but can be observed as a background radiation at around 1${\mu}m$ which is called the Cosmic Near-Infrared Background (CNB). Main part of the CNB is thought to be redshifted Lyman-alpha from gas clouds surrounding the Pop.III stars. Until now, the COBE (COsmic Background Explorer) and the IRTS (Infrared Telescope in Space) observed excess emission over the background due to galaxies. To confirm the COBE and the IRTS results and pursue more observational evidences, we carried out the sounding rocket experiment named the Cosmic Infrared Background ExpeRiment (CIBER). The CIBER is successfully launched on July 10, 2010 at White Sands Missile Range, New Mexico, USA. It consists of three kinds of instruments. We report the results obtained by LRS (Low Resolution Spectrometer) which is developed to fill the uncovered spectrum around 1${\mu}m$. LRS is a refractive telescope of 5.5 cm aperture with spectral resolution of 20 - 30 and wavelength coverage of 0.7 to 2.0${\mu}m$. After subtracting foreground components (zodiacal light, integrated star light and diffuse galactic light) from the sky brightness of observed five fields, there remained significant residual emission (even for the lower limit case) consistent with the IRTS and the COBE results. In addition, there exists a clear gap at 0.7 - 0.8${\mu}m$ in the CNB spectrum over the background due to galaxies according to recent results (Matsuoka et al. 2011; Mattila et al. 2011). The origin of the excess emission could be ascribed to the Pop.III stars with its active era of z = 7 - 10.

  • PDF

The Development of Water Quality Monitoring System and its Application Using Satellite Image Data

  • Jang, Dong-Ho;Jo, Gi-Ho
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.376-381
    • /
    • 1998
  • In this study, we was measured the radiance reflectance by using multi-spectral image of low resolution camera(LRC) which will be loaded in the multi-purpose satellite(KOMPSAT) to use the data in analyzing water pollution. Also we investigated the possibility of extraction of water quality factors in rivers and water body by using high resolution remote sensing data such as Airborne MSS. Especially, we tried to extract the environmental factors related with eutrophication, and also tried to develop the process technique and the radiance feature of reflectance related with eutrophication. The results were summarized as follows: First, the spectrum of sun's rays which reaches the surface of the earth was consistent with visible rays bands of 0.4${\mu}{\textrm}{m}$~0.7${\mu}{\textrm}{m}$ and about 50% of total quantity of radiation were there. And at around 0.5${\mu}{\textrm}{m}$ of green spectral band in visible rays bands, the spectrum was highest. Second, as a result of the radiance reflectance Chlorophyll-a represented high spectral reflectance mainly around 0.52${\mu}{\textrm}{m}$ of green spectral band, and suspended sediments and turbidity represented high spectral reflectance at 0.8${\mu}{\textrm}{m}$ and at 0.57${\mu}{\textrm}{m}$ each. Third, as a result of the water quality analysis by using Airborne MSS, Chlorophyll-a could have a distribution chart when carried out ratio of B3 and BS to B7. And Band 7 was useful for making the distribution chart of suspended sediments. And when we carried out PCA, suspended sediments and turbidity had distributions at PC 1 , PC 4 each similarly to ground truth data. Above results can be changed according to the change of season and time. Therefore, in order to analyze more exactly the environmental factors of water quality by using LRC data, we need to investigate constantly the ground truth data and the radiance feature of reflectance of water body. Afterward in this study, we will constantly analyze the radiance feature of the surface of water in water body by measuring the on-the-spot radiance reflectance and using low resolution satellite image(SeaWiFs). Besides, we will gather the data of water quality analysis in water body and analyze the pattern of water pollution.

  • PDF

A Study on the Reduction of Absorbed Dose through the Insertion of a Shielding Material in the Intraoralsensor of Dental Radiography (치과 방사선촬영 시 구내 센서 내 차폐체 삽입을 통한 피폭선량 감소 연구)

  • Kim, A Yeon;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.273-279
    • /
    • 2022
  • In order to reduce the absorbed dose given to the patient during dental radiography, a sensor that inserts a shield into the intraoralsensor was designed. Using the designed sensor, the change in absorbed dose depending on whether or not a shield was used was evaluated. The system used to evaluate the absorbed dose is VEX-S300C from Vatech, and the energy spectrum of X-rays was obtained through SPEKTR simulation based on the irradiation conditions of 65 kV, 3 mA, and 0.15 sec, and the number of photons for each energy was derived. After designing the system through Genat4 Application for Tomographic Emission(GATE) simulation, the energy spectrum obtained was used as a radiation source to calculate the absorbed dose. Lead was used for the shield, and simulations were performed at 0.1 mm thickness intervals from 0.1 mm to 0.5 mm was evaluated. In the case of using an X-ray field with a diameter of 60 mm, the decrease in absorbed dose according to the presence or absence of a shield decreased exponentially as the thickness of the shield increased. In addition, when a 20 mm × 30 mm field was used, the absorbed dose was significantly reduced even when no shield was used, and it was confirmed that the absorbed dose was further reduced when a shield was used.

Machine Learning-based Atmospheric Correction for Sentinel-2 Images Using 6SV2.1 and GK2A AOD (6SV2.1과 GK2A AOD를 이용한 기계학습 기반의 Sentinel-2 영상 대기보정)

  • Seoyeon Kim;Youjeong Youn;Jonggu Kang;Yemin Jeong;Soyeon Choi;Yungyo Im;Youngmin Seo;Chan-Won Park;Kyung-Do Lee;Sang-Il Na;Ho-Yong Ahn;Jae-Hyun Ryu;Yangwon Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_3
    • /
    • pp.1061-1067
    • /
    • 2023
  • In this letter, we simulated an atmospheric correction for Sentinel-2 images, of which spectral bands are similar to Compact Advanced Satellite 500-4 (CAS500-4). Using the second simulation of the satellite signal in the solar spectrum - vector (6SV)2.1 radiation transfer model and random forest (RF), a type of machine learning, we developed an RF-based atmospheric correction model to simulate 6SV2.1. As a result, the similarity between the reflectance calculated by 6SV2.1 and the reflectance predicted by the RF model was very high.

The Study on Design of Customized Radiation Protective Layer for Medical Radiation Dose Reduction (의료방사선 피폭선량 저감을 위한 맞춤형 차폐재 설계에 관한 연구)

  • Kang, Sang-Sik;Kim, Kyo-Tae;Noh, Si-Cheol;Jung, Bong-Jae;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.333-338
    • /
    • 2014
  • The fact is that in addition to an increase in social needs that must be managed systematically unnecessary exposure in the field of medical Recent important that the shield has emerged. However, products that are now in practical use, are not subdivided as compared to various medical radiology. Therefore, in the present study, we tried to present with the help of Monte Carlo simulation the structure of the shielding material that has been optimized. Simulated estimation result, the energy of the mammography for (30 kVp) spectrum, check the shielding rate of 90% or more $30{\mu}mPb$, at 2 mmAl case of shielding material of a single, at design time of 1 mmAl and 0.03 mmPb a double shield structure it is determined that more efficient. Also, check the blocking rate of 90% or more $340{\mu}mPb$, at 30 mmAl energy captured general in (80 kVp) spectra, it is considered that a double shield structure, design 1 mmAl and 0.3 mmPb is useful. These results, be used as basic material for the development of commercialization customized products for dose reduction is expected.

Radiolabeling of 11C-sertraline by fast and easy loop method with [11C]CH3OTf

  • Lee, Hak Jeong;Jeong, Jae Min;Lee, Sang-Yoon;Ido, Tatsuo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • Cis-(1S,4S)-4-(3,4-dichlorophenyl)-1,2,3,4-tertrahydro-N-methyl-1-naphthalenamine (sertraline) hydrochloride from among selective serotonin reuptake inhibitors (SSRIs) is a treatment of major depression. For the differential diagnosis by metabolizing serotonin in a patient with neurological disorders, the radiolabeled $^{11}C$-sertraline was developed for non-invasive positron emission tomography in living brain and use the evaluation of new drug for SSRIs. We release the results of a fast and easy radiolabeling method applied a one-step loop method with $[^{11}C]CH_3OTf$ for routine clinical applications of $^{11}C$-sertraline. 1 mg of a precursor for $^{11}C$-sertraline in 0.1 mL DMF and $5{\mu}L$ of 1N NaOH, were injected into the loop of semi-prep high-performance liquid chromatography (HPLC). $[^{11}C]CH_3OTf$ was passed through the loop at room temperature (RT). The $^{11}C$-sertraline was separated by the semi-preparative HPLC. $^{11}C$-sertraline was eluted at 28.0 min was collected and evaluated by analytical HPLC and mass spectrometer. The total radiolabeling efficiency of $^{11}C$-sertraline was $30.7{\pm}8.7%$. The specific activity was $64.8{\pm}51.4GBq/{\mu}mol$. The radiochemical and chemical purities were higher than 99%. The mass spectrum of the product showed m/z peaks at 307.1 (M+1), indicating the mass of sertraline. By the one-step loop method with $[^{11}C]CH_3OTf$, $^{11}C$-sertraline could be quickly and easily prepared for clinical application.

Peak Analysis of Gamma-ray and X-ray (감마선 및 엑스선의 피이크 분석)

  • Kim, Seung-Kon;Herr, Young-Hoi;Park, Kwang-June
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.33-42
    • /
    • 1984
  • A great variety of nuclear gamma rays emitted from fission and activation products of spent nuclear fuel contains much information that can be elicited without affecting the integrity of the fuel elements. But the extraction of such information from the complex spectrum is difficult and requires computer codes. In the present work, a versatile code 'CAERI' was developed which locates peaks and calculates their areas for X-rays as well as gamma rays using elegant features of some widely used programs for gamma-ray peak fitting. 'CAERI' coded in FORTRAN used infinite series approximation more accurate than other workers various, simple, piecewise series approximations for evaluations of the Voigt function which represents the X-ray peak with non-negligible natural line width. 'CAERI' can handle even a complex multiplet consisting of peaks from X-rays and gamma rays in arbitrary mixture, which one often encounters in the isotopic analysis of heavy elements such as U and Pu. The results of the fitting performed on the test spectra of $^{177m}\;Lu\;{\gamma}-ray\;and\;^{235}U\;K_{\alpha}$X-ray show good agreement with those by previous workers.

  • PDF

Evaluation of the Size of Emergency Planning Zone for the Korean Standard Nuclear Power Plants (한국표준형 원전에 대한 방사선비상계획구역 범위 평가)

  • Jeon, In-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.215-223
    • /
    • 2003
  • Against major release of radioactive material in nuclear power plant, Emergency Planning Zone(EPZ)s are typically established around nuclear power plants to effectively perform the public protective measures. The domestic methodology to determine the size of the EPZ is similar to that of Japan established in 1980, where calculations were based on the conservative accident source term. The objective of this study is to re-evaluate the validity of established EPZ, the area within the radius of $8{\sim}10km$ around domestic nuclear power plants, using the source terms covering full spectrum of accidents obtained from PSA study of ULJIN 3&4. To evaluate the risks of health effects, the computer code MACCS2(MELCOR Accident Consequence Code System2) was used. The result shows that the existing EPZ can reduce the probability of early fatality adequately for most of the source term categories(STCs) except for STC-14 and STC-19. In case of STC-14 and 19, the evacuation distance of 16km and 13km, respectively, are required. These distances can be reduced by improving emergency preparedness since the sensitivity studies for the public protective actions show that the magnitude of early fatality is largely affected by the time delays in notification and evacuation.

A Study on the Nuclear Structure through the Multipurpose Coincidence Measurement System Development (II) - Double ionization of the K-shell in $^{125}I$- (다목적 동시측정 장치 개발에 의한 원자핵 구조 연구 (II) - $^{125}I$ 붕괴시 K 각 이중 이온화 현상 -)

  • Chung, Won-Mo;Chung, Kap-Soo;Joo, Koan-Sik;Nam, Kie-Yong;Choi, Hey-Jin;Jeon, Woo-Ju;Na, Sang-Kyun;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.63-70
    • /
    • 1993
  • Double ionization of the K- shell accompanying K- shell electron capture of the 0.035 MeV transition of $^{125}I$ has been studied by counting coincidences between $K_{\alpha}$ hypersatellite X-rays and Ka satellite X-rays emitted when double vacancies are filled. The $^{125}I\;and\;^{125}Te^m$ source materials were used in the measurement. We obtained the coincidence spectrum using two NaI(T1) detectors and a Ge(Li) detector and TAC(Time-to-Amplitude Converter), and then analysed the measured coincidence number $N(K_{\alpha}^{II},\;K_{\alpha}^s)$, the total number $N(K_{\alpha})$ of K X-ray. The probability per K-shell electron capture that a double vacancy is formed, $P_{KK}$ is formed, $P_{KK}$ is found to be $2.15{\times}10^{-4}$.

  • PDF

Retrospective Analysis on 76 Cases of Cerebral Arteriovenous Malformations Treated by Gamma Knife Radiosurgery

  • Choe, Jae-Gyun;Im, Yong-Seok;Kim, Jong-Soo;Hong, Seung-Chyul;Shin, Hyung-Jin;Lee, Jung-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.6
    • /
    • pp.265-269
    • /
    • 2008
  • Objective : Outcome of gamma knife radiosurgery (GKS) in the consecutive 100 cases with cerebral arteriovenous malformations (AVMs) was analyzed. Methods : Data from initial 100 patients treated with GKS in the authors' institute were reviewed retrospectively. Spetzler-Martin grade at diagnosis were I in 18 patients, II in 27, III in 36, IV in 11, and V in 8. Thirty-five patients had experienced previous bleeding, 27 patients presented with seizure, and 31 patients presented with headache. The mean volume of the lesion was $4.3\;cm^3\;(0.1-29.3\;cm^3)$. The median radiation dose delivered to the margin was 20.0Gy (13-32Gy). Mean follow-up period was 37.5 months (5-63 months). Results : Angiographic follow-up was performed in 48 patients at least 2 years after GKS. Sixteen patients were lost in follow up following 2 years from GKS. Twenty-eight of 48 patients (58%) showed complete obliteration and 20 patients (42%) showed partial obliteration. Seven patients presented with post-GKS hemorrhage. Adverse radiation effect (ARE) was observed at follow-up MRI in 25 of 76 patients, and it was symptomatic in 5 patients. Complete obliteration was confirmed in 24 of 31 (77%) patients with volume less than $4\;cm^3$, meanwhile only 4 of 17 (24%) patients with volume of $4\;cm^3$ or more showed complete obliteration. Complete obliteration rate was 67% with 20Gy or higher marginal dose, 63% with 15-20 Gy, and 17% with less than 15Gy. Conclusion : GKS can provide high rates of obliteration with acceptable risk of morbidity in a subgroup of small AVMs. However, overall outcome in whole spectrum of AVMs, in which large proportion of cases have unfavorable characteristics for radiosurgery, is much worse. More effective therapeutic strategy needs to be developed for large AVMs that are difficult to be managed with current available treatment modalities.