• Title/Summary/Keyword: Radiation spectrum

Search Result 509, Processing Time 0.021 seconds

A Study on Photoneutron Characteristics Generated from Target and Collimator of Electron Linear Accelerator for Container Security Inspection using MCNP6 Code (MCNP6 코드를 이용한 컨테이너 보안 검색용 전자 선형가속기 표적과 조준기에서 발생한 광중성자 특성에 관한 연구)

  • Lee, Chang-Ho;Kim, Jang-Oh;Lee, Yoon-Ji;Jeon, Chan-hee;Lee, Ji-Eun;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.455-465
    • /
    • 2020
  • The purpose of this study is to evaluate the photoneutron characteristics generated by the linear accelerator target and collimator. The computer simulation design firstly, consisted of a target, a single material target and a composite material target. Secondly, it consisted of a cone beam and a fan beam depending on the type of the collimator. Finally, the material of the fan beam collimator is composed of a single material composed of only lead (Pb) and a composite material collimator composed of tungsten (W) and lead (Pb). The research method calculated the photoneutron production rate and energy spectrum using F2 tally from the surface of a virtual sphere at a distance of 100 cm from the target. As a result, firstly the photoneutron production rate was 20% difference, depending on the target. Secondly, depending on the type of the collimator, there was a 10% difference. Finally, depending on the collimator material, there was a 40% difference. In the photoneutron energy spectrum, the average photoneutron flux tended to be similar to the photoneutron production rate. As a result, it was confirmed that the 9 MeV linear accelerator photoneutron are production increased more by the collimator than by the target, and by the material, not the type of the collimator. Selecting and operating targets and collimator with low photoneutron production will be the most active radiation protection. Therefore, it is considered that this research can be a useful data for introducing and operating and radiation protection of a linear accelerator for container security inspection.

A Comparative Study on Effective One-Group Cross-Sections of ORIGEN and FISPACT to Calculate Nuclide Inventory for Decommissioning Nuclear Power Plant

  • Cha, Gilyong;Kim, Soonyoung;Lee, Minhye;Kim, Minchul;Kim, Hyunmin
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.99-106
    • /
    • 2022
  • Background: The radionuclide inventory calculation codes such as ORIGEN and FISPACT collapse neutron reaction libraries with energy spectra and generate an effective one-group cross-section. Since the nuclear cross-section data, energy group (g) structure, and other input details used by the two codes are different, there may be differences in each code's activation inventory calculation results. In this study, the calculation results of neutron-induced activation inventory using ORIGEN and FISPACT were compared and analyzed regarding radioactive waste classification and worker exposure during nuclear decommissioning. Materials and Methods: Two neutron spectra were used to obtain the comparison results: Watt fission spectrum and thermalized energy spectrum. The effective one-group cross-sections were generated for each type of energy group structure provided in ORIGEN and FISPACT. Then, the effective one-group cross-sections were analyzed by focusing on 59Ni, 63Ni, 94Nb, 60Co, 152Eu, and 154Eu, which are the main radionuclides of stainless steel, carbon steel, zircalloy, and concrete for decommissioning nuclear power plant (NPP). Results and Discussion: As a result of the analysis, 154Eu and 59Ni may be overestimated or underestimated depending on the code selection by up to 30%, because the cross-section library used for each code is different. When ORIGEN-44g, -49g, and -238g structures are selected, the differences of the calculation results of effective one-group cross-section according to group structure selection were less than 1% for the six nuclides applied in this study, and when FISPACT-69g, -172g, and -315g were applied, the difference was less than 1%, too. Conclusion: ORIGEN and FISPACT codes can be applied to activation calculations with their own built-in energy group structures for decommissioning NPP. Since the differences in calculation results may occur depending on the selection of codes and energy group structures, it is appropriate to properly select the energy group structure according to the accuracy required in the calculation and the characteristics of the problem.

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.

Evaluation of Image Quality for Radiographic Positioning using IEC Radiation Quality in the Digital Radiography System (디지털방사선시스템에서 IEC표준을 이용한 방사선 영상 품질의 평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.289-299
    • /
    • 2015
  • The purpose of this study is to evaluate and compare the quality of digital X-ray imaging system. The image quality evaluation was conducted By using Modulation transfer function indicating the quantitative resolution of the image and the noise power spectrum showing the noise characteristics. Using a IEC61267 radiation quality was applied to the geometry to be used in clinical and geometry presented in IEC62220-1 and Additional filter, grid, the clinical dose and the MTF value of edge phantom was measured. Result of the MTF corresponding to each item(Grid, Filter, SID, kVp, mAs), the clinical condition 100cm, 180cm, measurements of the spatial frequency of the MTF IEC62220-1Geometry 150cm became similarly apparent, rather spatial frequency was also the case high in clinical conditions 100cm. NPS results, as the dose(mAs) is increased, NPS showed that reduced. The image quality evaluation using IEC61267 the Radiation quality, Image quality of the video using the clinical conditions Geometry than image quality evaluation using IEC62220-1Geometry was better. It shows that MTF and NPC in IEC and clinical condition were not significantly different. In order to apply the evaluation method of image quality applied with clinical conditions rather than the future method, to be presented evaluation of IEC standard, based on the results of the image characterization studies in this paper, the methods that shows good quality of spatial resolution and decrease NPS value as the least dose, used suitable parameters for whether or not using added filter, grid, change SID and clinical quality(kVp), dose(mAs) etc should be found. then It is believed to be able to properly maintain the actual quality of the image of the digital radiographic imaging system in clinical.

A Measurement of the Exposure Rates by Terrestrial y-rays in Taegu Area (대구지역(大邱地域) 지각(地殼) ${\gamma}$-선(線)의 조사선량율(照射線量率) 측정(測定))

  • Chang, Si-Ho;Jeong, Chun-Gyun;Kang, Hee-Dong;Lee, Mo-Sung;Choi, Mun-Kyu;Kim, Wi-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.2
    • /
    • pp.121-132
    • /
    • 1994
  • This study concerns about the measurement and the investigation of environmental radiation characteristics which the components and the distribution of exposure rates by terrestrial y-rays in Taegu area. $4^{'}{\phi}{\times}4^{'}$ NaI(T1) scintillation detector with a multichannel analyzer was used in the measurement of y-rays as a part of in-situ spectrometry at twenty eight different locations in this area. The conversion into the exposure rate from the measured ${\gamma}-ray$ spectrum has been carried out leading to a net exposure rate and component ones by $^{40}K,\;^{238}U$ series and $^{232}Th$ series products which are known by the major parts in the terrestrial ${\gamma}-rays$ generally. As a result, the average exposure rate by the terrestrial ${\gamma}-rays$ in Taegu area is $9.4{\mu}R/h$ and the distribution of individual exposure rates shows more or less differences between these locations even after the consideration of diurnal and yearly variations which are always involved in these measurements. The component parts of exposure rates are distributed $^{40}K\;2.9{\sim}4.6{\mu}R/h,\;^{238}U$ series $1.2{\sim}3,\;1{\mu}R/h,\;^{232}Th$ series $2.5{\sim}5.0{\mu}R/h$ over the measured locations.

  • PDF

Clinical Application of the Dual Energy Photon Beam Using 6 MV and 10 MV X-ray (6MV 및 10 MV X-ray의 이중에너지를 생성하는 방사선 발생장치의 임상적 이용)

  • Lee, Myung-Za;Han, Hye-Gyeong
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.93-99
    • /
    • 1988
  • Some modern accerelators provide a dual energy for photon beam treatment. The main advantages of dual energy in the treatment of rectosigmoid or rectal cancer are as fellows. 1. Dose in the critical organ such as small intestine, bladder and genital organ are reduced. 2. Presacral and perineal area is fully covered. Dose distribution analysis such as calculation of dose in a target volume, isocenter, $D_{nax}$ and dose spectrum in any region of interest are possible. Examples of plan are given and results are discussed.

  • PDF

Radiation Shielding Analysis on The Spent Fuel Storage Facility for the Extended Fuel Cycle (장주기(長週期) 핵연료(核燃料) 저장시설(貯藏施設)에서의 방사선차폐해석(放射線遮蔽解析))

  • Lee, Tae-Young;Ha, Chung-Woo;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.90-96
    • /
    • 1984
  • Estimated dose rates in spent fuel pool storage with the extended fuel cycle core management were reviewed and compared with design limit after calculation with the aid of DLC-23/CASK(22 n, 18 g) nuclear data and ANISN code. Radioactivity and gamma spectrum within spent fuel assemblies were calculated with ORIGEN code by extended fuel cycle model. In the calculation of dose rate, the fuel pool geometry was assumed to be infinite slab. Also, composition materials and radiation source within assemblies which are being stored in pool storage were assumed to be uniformly distributed throughout all the assemblies. As a result of culculation of dose rate from stored assemblies and waterborne radionuclides in pool water, the calculated dose rates appear to be lower than design basis limit under normal condition as well as abnormal condition.

  • PDF

Neutron fluence measurement at HANARO using fluence monitor method (Fluence Monitor를 이용한 HANARO 노심 내 중성자 플루언스 측정)

  • Lee, Seung-Kyu;Jo, Kwang-Ho;Choo, Kee-Nam;Park, Jin-Suk;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.200-208
    • /
    • 2011
  • The neutron fluence measurement and evaluation technology is very important for material irradiation test. The most essential technology in this study is the neutron irradiation evaluation method using a fluence monitor. The fluence monitors were fabricated with metal wires of the purity ${\geq}$ 99.9%, whose dimensions were 0.1mm diameter, about 3 mm length, and around 150-200 ${\mu}g$ mass range. Three wire samples (Fe, Ni, Ti) were prepared for one irradiation aluminum capsule. Five capsules were irradiated in the OR5 hole of the HANARO reactor at 30 MW power for about 25 days. After irradiation tests, radiation activities were measured with the high purity germanium (HPGe) detector. The reaction rates were calculated by using the measured radiation activity data, and then neutron fluence were obtained from the reaction rates and the weighted neutron cross section with calculated neutron spectrum at the fluence monitor position.

Diagnostic X-ray Spectra Detection by Monte Carlo Simulation (진단용 X-선 스펙트럼의 몬테칼로 전산모사 측정)

  • Baek, Cheol-Ha;Lee, Seung-Jae;Kim, Daehong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.289-295
    • /
    • 2018
  • Most diagnostic devices in the medical field use X-ray sources, which emit energy spectra. In radiological diagnosis, the quantitative and qualitative analyses of X-rays are essential for maintaining the image quality and minimizing the radiation dose to patients. This work aims to obtain the X-ray energy spectra used in diagnostic imaging by Monte Carlo simulation. Various X-ray spectra are simulated using a Monte Carlo simulation tool. These spectra are then compared to the reference data obtained with a tungsten anode spectral model using the interpolating polynomial (TASMIP) code. The X-ray tube voltages used are 50, 60, 80, 100, and 110 kV, respectively. CdTe and a-Se detector are used as the detectors for obtaining the X-ray spectra. Simulation results demonstrate that the various X-ray spectra are well matched with the reference data. Based on the simulation results, an appropriate X-ray spectrum, in accordance with the tube voltage, can be selected when generating an image for diagnostic imaging. The dose to be delivered to the patient can be predicted prior to examination in the diagnostic field.

Slat Noise Source Modeling of Multi-element Airfoil in High-lift Configuration

  • Hwang, Seung Tae;Han, Chang Kyun;Im, Yong Taek;Kim, Jong Rok;Bae, Youngmin;Moon, Young J.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.2
    • /
    • pp.197-205
    • /
    • 2017
  • We investigate the slat noise generation mechanism by using large-eddy simulation (LES) and simple source modeling based on linearized Euler equations. An incompressible LES of an MD 30P30N three-element airfoil in the high-lift configuration is conducted at $Re_c=1.7{\times}10^6$. Using the total derivative of the hydrodynamic pressure (DP/Dt) acquired from the incompressible LES, representative noise sources in the slat cove region are characterized in terms of simple sources such as frequency-specific monopoles and dipoles. Acoustic radiation around the 30P30N multi-element airfoil is effectively computed using the Brinkman penalization method incorporated with the linearized Euler equation. The directivity pattern of $p^{\prime}_{rms}$ at $r=20c_{slat}$ in the multiple sources is closely compared to that obtained by the application of the LES/Ffowcs-Williams and Hawking's methods to the entire flow field. The power spectrum of p' at ${\theta}=290^{\circ}$ is in good agreement with the data reported in BANC-III, especially the broadband part of the spectrum with a decaying slope ${\propto}f^{-3}$.