• 제목/요약/키워드: Radiation spectrum

검색결과 511건 처리시간 0.031초

방사선 포털 모니터용 대용적 플라스틱 섬광체 내부 빛 수집 효율 평가 (Light Collection Efficiency of Large-volume Plastic Scintillator for Radiation Portal Monitor)

  • 이진형;김종범
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.157-165
    • /
    • 2017
  • In this paper, we calculate the light photons collection efficiency of large-volume plastic scintillation detector mainly used for radiation portal monitor (RPM). A Monte Carlo light photon transport code, DETECT2000, were used to quantitatively evaluate light collection efficiency of plastic scintillation detector. DETECT2000 calculated the placement of light collection efficiency based on the energy spectrum. We calculated the light collection efficiency relative to the position of the energy spectrum that proportional to the placement of the source. The $850{\times}285{\times}65mm^3$ size of polyvinyl toluene (PVT) scintillator was used for measurements. Through DETECT2000 simulation, the light collection efficiency of $5{\times}5$ arrays were calculated and verification was performed by comparing with experimentally measured. And then, the corrected MCNP simulation by applying the light collection efficiency in $21{\times}13$ arrays was compared and analyzed. Comparing the Monte Carlo simulation with measured results, it shows an average difference of 10.1% in $5{\times}5$ arrays. Particularly, about twice of the difference was found in the edge of first column, which coupled with PMT. In whole $5{\times}5$ array, the overall ratio was the same except for the first column. And then comparing the energy spectra of the $21{\times}13$ array with and without the light collection efficiency, it shows a difference of 6.69% in Compton edge area. The DETECT2000 based light collection efficiency simulation showed well agreement with the point source experiment. And comparing with measured energy spectra, we could compare the differences according to whether or not the light collection efficiency was applied. As a results, it is possible to increase the accuracy and reliability of Monte Carlo simulation results by pre-calculating the light collection efficiency according to the PVT geometry by using the DETECT2000.

간접평판형 검출기에서 국제전자기술위원회 기준을 통한 잡음전력스펙트럼 비교 연구 (Comparison of Noise Power Spectrum in Measurements by Using International Electro-technical Commission Standard Devices in Indirect Digital Radiography)

  • 민정환;정회원;김기원;권경태;정재용;손진현;김현수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.457-462
    • /
    • 2018
  • The purpose of this study was to compare image quality of indirect digital radiography (IDR) system using the International Electro-technical Commission standard (IEC 62220-1), and to suggest the analysis of noise power spectrum (NPS) which were applied to IEC 62220-1 in medical imaging. In this study, Pixium 4600 (Trixell, France) which is indirect flat panel detector (FPD) was used. The size of image receptor (IR) is $7{\times}17$ inch (matrix $3001{\times}3001$) which performed 14bit processing and pixel pitch is $143{\mu}m$. In IEC standard, NPS evaluation were applied to RQA3, RQA5, RQA7 and RQA9. Because of different radiation quality, each region of interesting (ROI) were compared. The results of NPS indicated up to $3.5mm^{-1}$ including low Nyquist frequency. RQA5 indicated the lowest NPS and the others indicated higher NPS results relatively. NPS result of ROI a38 was higher than ROI a92 and this result indicated that there are more noise in left (cathode) than right (anode). This study were to evaluate NPS by using different radiation quality and setting the each ROI, and to suggest the quantitative methods of measuring NPS.

전자스핀공명법(ESR)을 이용한 방사선조사 조제유류의 판별 (Detection of Irradiated Milk Formulas using Electron Spin Resonance)

  • 운재호;박병룡;최병국;김나영;정홍점;정기수;김희선;김창섭
    • Journal of Dairy Science and Biotechnology
    • /
    • 제28권2호
    • /
    • pp.13-18
    • /
    • 2010
  • 방사선 조사된 완제품 조제분유를 포함한 시료 4종의 ESR 스펙트럼 특성을 측정하였다. 조제분유와 전지분유의 비조사 시료는 g=2.0050의 아주 약한 singlet 형태의 스펙트럼을 나타내었다. 조사 시료에서 전지분유는 g=2.0050의 singlet 형태의 스펙트럼, 조제분유는 전지분유와 같은 중심 피크 옆에 g=2.0006의 작은 피크를 가진 비대칭 형태의 스펙트럼을 나타내었고, 두 시료 모두 비조사 시료와 조사 시료의 신호 세기 차이가 명확하여 조사유무 판별이 가능하였다. 포도당과 유당의 비조사 시료는 아무런 시그널을 나타내지 않았으며, 조사 시료는 이미 알려져 있는 결정형 당 유래의 다형 피크를 가진 스펙트럼을 나타내었다. 선량이 증가함에 따라 신호 세기도 증가하였고, 회귀방정식의 상관계수는 0.95 이상의 높은 값을 나타내었다. 감마선과 전자선 조사에 의한 ESR 스팩트럼 간의 유의성 있는 차이는 없는 것으로 확인되었다. 결론적으로 본 실험을 통하여 ESR 분석은 방사선 조사된 조제분유 및 원료의 판별에 유용한 방법으로 적용될 수 있는 것으로 판단되었으며, 온도, 습도 및 전처리 조건 등의 요인에 의한 변화 가능성과 식품 생산 및 장기유통 기간 등을 고려할 때 이에 대한 지속적인 연구와 자료 축적이 요구된다고 할 것이다.

  • PDF

EUV 리소그라피 광원용 레이저 생성 Xe 가스 플라즈마의 가시화 (Visualization of Laser-Produced, Xe Gas Plasma in EUV Light Sources for the Lithography)

  • Jin Yun-Sik;Jeong Sun-Sin;Kim Jong-Uk;Kim Chang-Beom;Kim Yong-Ju
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 하계학술발표회
    • /
    • pp.106-107
    • /
    • 2002
  • Extreme ultraviolet (EUV) radiation of wavelength $\lambda$~10 nm or photon energy hv~100 eV is presently a blank region in the electromagnetic spectrum where applications are concerned. This is because no powerful sources were available until when intense-laser-produced plasmas are available. Both a new laboratory-sized source of EUV radiation and its new applications in lithography of semiconductor devices have been developed. (omitted)

  • PDF

Optimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation

  • Ju, Eun Bin;Ahn, So Hyun;Choi, Sang Gyu;Lee, Rena
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.125-130
    • /
    • 2016
  • Dual energy computed tomography (DECT) is used to classify two materials and quantify the mass density of each material in the human body. An energy modulation filter based DECT could acquire two images, which are generated by the low- and high-energy photon spectra, in one scan, with one tube and detector. In the case of DECT using the energy modulation filter, the filter should perform the optimization process for the type of materials and thicknesses for generating two photon spectra. In this study, Geant4 Monte-Carlo simulation toolkit was used to execute the optimization process for determining the property of the energy modulation filter. In the process, various materials used for the energy modulation filter are copper (Cu, $8.96g/cm^3$), niobium (Nb, $8.57g/cm^3$), stannum (Sn, $7.31g/cm^3$), gold (Au, $19.32g/cm^3$), and lead (Pb, $11.34g/cm^3$). The thickness of the modulation filter varied from 0.1 mm to 1.0 mm. To evaluate the overlap region of the low- and high-energy spectrum, Geant4 Monte-Carlo simulation is used. The variation of the photon flux and the mean energy of photon spectrum that passes through the energy modulation filter are evaluated. In the primary photon spectrum of 80 kVp, the optimal modulation filter is a 0.1 mm lead filter that can acquire the same mean energy of 140 kVp photon spectrum. The lead filter of 0.1 mm based dual energy CBCT is required to increase the tube current 4.37 times than the original tube current owing to the 77.1% attenuation in the filter.

Dosimetrical Analysis of Reactor Leakage Gamma-rays by Means of Scintillation Spectrometry

  • Jun, Jae-Shik
    • Nuclear Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.291-309
    • /
    • 1973
  • TRIGA Mark II와 III 원자로의 여러가지 가동조건에 있어서 노벽으로 부터의 누설 ${\gamma}$선에 의한 조사선양률을 3"$\times$3"원통형 NaI(T1) 섬광계수기와 400 channel파 고분석장치로 측정하였는데 측정된 spectrum으로부터 조사선양률을 산출하는데는 실제적면에서 복잡하기 짝이 없는 response matrix 방법대신 정도가 좋으면서도 비교적 그 과정이 단순한 Moriuchi의 specturm -조사선양률 환산 이론을 적용하였다. 연구결과에 따르면 노심에서 발생된 누설 ${\gamma}$선의 기본적인 spectrum 형태는 원자로의 열출력이나 차장벽에 의한 강도의 감쇠에 별로 영향을 받지 않고 있으며 원자로 누설${\gamma}$선에 의란 전조사선양률의 공기중에서의 감쇠는 폭 넓은 energy분포에도 불구하고 지수함수적 감쇠를 하고 있음이 판명되있다. 이 전조사선양률은 원자로의 열출력에 대체로 비례하고 있으나 TRIGA Mark III과 같은 가동형노심의 경우는 측정된 spectrum이 매우 다양한바, 그로부터 산출된 전조사선양률의 크기에는 관계없이, spectrum 분해방법을 적용하여 노심에서 발생된 누설 ${\gamma}$선과 원자로가동중 발생되는 여지 ${\gamma}$선의 기여를 판별 해석하는데 성공하였다.

  • PDF

Action Spectra of Apoptosis Induction and Reproductive Cell Death in L5178Y cells in UV-B Region

  • Mizuho Aoki;Yoshiya Furusawa;Higashi, Sho-ichi;Masakatsu Watanabe
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.454-456
    • /
    • 2002
  • It is important to determine the action spectrum of UV-B radiation contained in the sunlight to estimate the risk of skin cancer. We have investigated action spectra for induction of apoptosis and reproductive cell death in L5178Y cells using the Okazaki Large Spectrograph at NIBB. L5178Y cells were exposed to light at different wavelengths in UV-B or UV-A region. Frequencies of apoptosis induction and reproductive cell death were determined by counting cells with chromatin condensation, and by the colony formation assay, respectively. The measured sensitivity spectra for the two end-points were in very good agreement. Sensitivity decreased steeply with increase of wavelength in UV-B region and remains nearly constant in UV-A region. The action spectra were also slightly steeper than that for the minimum erythematic dose (MED), but very similar to the light absorption spectrum of DNA in UV-B region. On the other hand, the spectra for both endpoints were similar to MED spectrum but not DNA spectrum in the UV-A region. Also different time-course and morphological difference of apoptosis were found between UV-B (long time, fragmentation) and UV-A (short time, shrinkage) region. These results suggest that DNA damage induced by UV-B light triggers apoptosis and reproductive cell death, but other damaged targets (membrane, protein and so on) trigger these effects in UV-A region.

  • PDF

Probing Gamma-ray Emission of Geminga and Vela with Non-stationary Models

  • Chai, Yating;Cheng, Kwong-Sang;Takata, Jumpei
    • Journal of Astronomy and Space Sciences
    • /
    • 제33권2호
    • /
    • pp.75-92
    • /
    • 2016
  • It is generally believed that the high energy emissions from isolated pulsars are emitted from relativistic electrons/positrons accelerated in outer magnetospheric accelerators (outergaps) via a curvature radiation mechanism, which has a simple exponential cut-off spectrum. However, many gamma-ray pulsars detected by the Fermi LAT (Large Area Telescope) cannot be fitted by simple exponential cut-off spectrum, and instead a sub-exponential is more appropriate. It is proposed that the realistic outergaps are non-stationary, and that the observed spectrum is a superposition of different stationary states that are controlled by the currents injected from the inner and outer boundaries. The Vela and Geminga pulsars have the largest fluxes among all targets observed, which allows us to carry out very detailed phase-resolved spectral analysis. We have divided the Vela and Geminga pulsars into 19 (the off pulse of Vela was not included) and 33 phase bins, respectively. We find that most phase resolved spectra still cannot be fitted by a simple exponential spectrum: in fact, a sub-exponential spectrum is necessary. We conclude that non-stationary states exist even down to the very fine phase bins.