Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Comorbid Conditions in Persons Exposed to Ionizing Radiation and Veterans of the Soviet-Afghan War: A Cohort Study in Kazakhstan

  • Saule Sarkulova;Roza Tatayeva;Dinara Urazalina;Ekaterina Ossadchaya;Venera Rakhmetova
    • Journal of Preventive Medicine and Public Health
    • /
    • 제57권1호
    • /
    • pp.55-64
    • /
    • 2024
  • Objectives: This study investigated the prevalence and characteristics of comorbid conditions in patients exposed to ionizing radiation and those who were involved in the Soviet-Afghan war. Methods: This study analyzed the frequency and spectrum of morbidity and comorbidity in patients over a long-term period (30-35 years) following exposure to ionizing radiation at the Semipalatinsk nuclear test site or the Chornobyl nuclear power plant, and among participants of the Soviet-Afghan war. A cohort study, both prospective and retrospective, was conducted on 675 patients who underwent comprehensive examinations. Results: Numerical data were analyzed using the Statistica 6 program. The results are presented as the mean±standard deviation, median, and interquartile range (25-75th percentiles). The statistical significance of between-group differences was assessed using the Student t-test and Pearson chi-square test. A p-value of less than 0.05 was considered statistically significant. We found a high prevalence of cardiovascular diseases, including hypertension (55.0%) and cardiac ischemia (32.9%); these rates exceeded the average for this age group in the general population. Conclusions: The cumulative impact of causal occupational, environmental, and ultra-high stress factors in the combat zone in participants of the Soviet-Afghan war, along with common conventional factors, contributed to the formation of a specific comorbidity structure. This necessitates a rational approach to identifying early predictors of cardiovascular events and central nervous system disorders, as well as pathognomonic clinical symptoms in this patient cohort. It also underscores the importance of selecting suitable methods and strategies for implementing treatment and prevention measures.

EPID의 적정관리 도구로서의 유용성에 관한 연구 (The useage of the EPID as a QA tools)

  • 조정희;방동완;윤성익;박재일
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF

방사선치료의 다양한 EPID 영상 질평가 (Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 손순룡;최관우;김정민;정회원;권경태;조정희;이제희;정재용;김기원;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.451-461
    • /
    • 2015
  • MV방사선 치료는 둘러싸여 있는 정상조직의 피폭선량을 최소화 하면서, target volume 내에 정확하게 선량을 전달하는데 있어 중요한 요인이다. 본 연구에서는 방사선 치료의 높은 정확성을 유지하기 위하여 megavoltage X-ray imaging (MVI)에서 edge block 을 사용한 digital radiography (DR) system 검출기의 modulation transfer function (MTF: 변조전달함수), the noise power spectrum (NPS: 잡음전력스펙트럼) and the detective quantum efficiency (DQE: 양자검출효율)를 측정하고자 한다. 우리는 텅스텐으로 구성된 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$의 edge block을 사용하였으며, 다음과 같은 setting들로 pre-sampling modulation transfer function (MTF)를 계산하였다: 6-megavolt (MV) energy를 사용하고, 다양한 Radiotherapy장비인 TrueBeamTM (Varian), BEAMVIEWPLUS (Siemens), iViewGT (Elekta), ClinacR iX (Varian) 를 사용하였다. MTF결과에서 Varian TrueBeamTM flattening filter free가 MTF의 50% ($mm^{-1}$)에서 0.46, 10% ($mm^{-1}$) 에서 1.40로 가장 highest value를 보였다. Noise 분포는 Elekta iViewGT가 가장 낮은 분포를 보였다. DQE에서는 E lekt a iViewGT가 peak DQE에서 0.0026 그리고 $1mm^{-1}$ DQE 에서 0.00014로 가장 높았다. 본 연구는 Edge method를 이용하여 MTF와 DQE산출을 재현하였으며, 현재 임상에서 사용되는 DR 시스템 측정의 높은 정확성을 유지할 수 있었으며 이러한 연구는 전통적인 QA 영상화뿐만 아니라 검출기 개발 연구에 있어서 정량적인 MTF, NPS, DQE 측정에 더욱 더 효율적으로 사용될 수 있다는 것을 알 수 있다.

EFFECTS OF WAVE-PARTICLE INTERACTIONS ON DIFFUSIVE SHOCK ACCELERATION AT SUPERNOVA REMNANTS

  • Kang, Hyesung
    • 천문학회지
    • /
    • 제46권1호
    • /
    • pp.49-63
    • /
    • 2013
  • Nonthermal radiation from supernova remnants (SNRs) provides observational evidence and constraints on the diffusive shock acceleration (DSA) hypothesis for the origins of Galactic cosmic rays (CRs). Recently it has been recognized that a variety of plasma wave-particle interactions operate at astrophysical shocks and the detailed outcomes of DSA are governed by their complex and nonlinear interrelationships. Here we calculate the energy spectra of CR protons and electrons accelerated at Type Ia SNRs, using time-dependent, DSA simulations with phenomenological models for magnetic field amplification due to CR streaming instabilities, Alf$\acute{e}$enic drift, and free escape boundary. We show that, if scattering centers drift with the Alf$\acute{e}$en speed in the amplified magnetic fields, the CR energy spectrum is steepened and the acceleration efficiency is significantly reduced at strong CR modified SNR shocks. Even with fast Afv$\acute{e}$nic drift, DSA can still be efficient enough to develop a substantial shock precursor due to CR pressure feedback and convert about 20-30% of the SN explosion energy into CRs. Since the high energy end of the CR proton spectrum is composed of the particles that are injected in the early stages, in order to predict nonthermal emissions, especially in X-ray and ${\gamma}-ray$ bands, it is important to follow the time dependent evolution of the shock dynamics, CR injection process, magnetic field amplification, and particle escape. Thus it is crucial to understand the details of these plasma interactions associated with collisionless shocks in successful modeling of nonlinear DSA.

GPS QUASARS AS SPECIAL BLAZARS

  • BAI J. M.;LEE MYUNG GYONG
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.125-128
    • /
    • 2005
  • In this paper, we argue that the gigahertz peaked spectrum (GPS) quasars are special blazars, blazars in dense and dusty gas enviornment. The ROSAT detection rate of GPS quasars is similar to that of flat spectrum radio quasars (FSRQs), suggesting that the relativistic jets in GPS quasars are oriented at small angle to the line of sight. Due to strong inverse Compton scattering off infrared photons from dense and dusty nuclear interstellar media in GPS quasars, most of them may have significant soft gamma-ray and X-ray emission, which is consistent with ASCA X-ray observations. Because Compton cooling in GPS quasars is stronger than that in FSRQs, synchrotron emission in GPS quasars may less dominate over thermal emission of the accretion disk and hot dust, hence most GPS quasars show low optical polarization and small variability, consistent with observations. We suggest that it is the significant radio emission of electron/positron pairs produced by the interaction of gamma-rays with the dense gas and dust grains in GPS quasars that makes GPS quasars show steep radio spectra, low radio polarization, and relatively faint VLBI/VLBA cores. Whether GPS quasars are special blazars can be tested by gamma-ray observations with GLAST in the near future, with the detection rate of GPS quasars being similar to that of FSRQs.

Effect of Neutron Energy Spectra on the Formation of the Displacement Cascade in ${\alpha}-Iron$

  • Kwon Junhyun;Seo Chul Gyo;Kwon Sang Chul;Hong Jun-Hwa
    • Nuclear Engineering and Technology
    • /
    • 제35권5호
    • /
    • pp.497-505
    • /
    • 2003
  • This paper describes a computational approach to the quantification of primary damage under irradiation and demonstrates the effect of neutron energy spectra on the formation of the displacement cascade. The development of displacement cascades in ${\alpha}-Iron$ has been simulated using the MOLDY code - a molecular dynamics code for simulating radiation damage. The primary knock-on atom energy, key input to the MOLDY code, was determined from the SPECTER code calculation on two neutron spectra. The two neutron spectra include; (i) neutron spectrum in the instrumented irradiation capsule of the high-flux advanced neutron application reactor (HANARO), and (ii) neutron spectrum at the inner surface of the reactor pressure vessel steel for the Younggwang nuclear power plant No.5 (YG 5). Minor differences in the normalized neutron spectra between the two spectra produce similar values of PKA energy, which are 4.7 keV for HANARO and 5.3 keV for YG 5. This similarity implies that primary damage to the components of the commercial nuclear reactors should be well simulated by irradiation in the HANARO. Moreover, the application of the MD calculations corroborates this statement by comparing cascades simulation results.

Trichel Pulse in Negative DC Corona discharge and Its Electromagnetic Radiations

  • Zhang, Yu;Liu, Li-Juan;Miao, Jin-Song;Peng, Zu-Lin;Ouyang, Ji-Ting
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1174-1180
    • /
    • 2015
  • We investigate in this paper the radiated electromagnetic waves together with the discharge characteristics of Trichel pulse of negative DC corona discharge in air in pin-to-plate and wire-to-plate configurations. The feature of the current pulse and the frequency spectrum of the electromagnetic radiations were measured under various pressures and gas gaps. The results show that the repetition frequency and the amplitude of Trichel pulse current depend on the discharge conditions, but the rising time of the pulse relates only to the radius of needle or wire and keeps constant even if the other conditions (including the discharge current, the gas gap and the gas pressure) change. There exists the characterized spectrum of electromagnetic waves from negative corona discharge in Trichel pulse regime. These characterized radiations do not change their frequency at a given cathode geometry even if the averaged current, the gas gap or the air pressure changes, but the amplitude of radiations changes accordingly. The characterized electromagnetic radiations from Trichel pulse corona relate to the formation or the rising edge of current pulse. It confirms that the characterized radiations from Trichel pulse supply information of discharge system and provide a potential method for detecting charged targets.

조명을 위한 인간 자세와 다중 모드 이미지 융합 - 인간의 이상 행동에 대한 강력한 탐지 (Multimodal Image Fusion with Human Pose for Illumination-Robust Detection of Human Abnormal Behaviors)

  • ;공성곤
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 추계학술발표대회
    • /
    • pp.637-640
    • /
    • 2023
  • This paper presents multimodal image fusion with human pose for detecting abnormal human behaviors in low illumination conditions. Detecting human behaviors in low illumination conditions is challenging due to its limited visibility of the objects of interest in the scene. Multimodal image fusion simultaneously combines visual information in the visible spectrum and thermal radiation information in the long-wave infrared spectrum. We propose an abnormal event detection scheme based on the multimodal fused image and the human poses using the keypoints to characterize the action of the human body. Our method assumes that human behaviors are well correlated to body keypoints such as shoulders, elbows, wrists, hips. In detail, we extracted the human keypoint coordinates from human targets in multimodal fused videos. The coordinate values are used as inputs to train a multilayer perceptron network to classify human behaviors as normal or abnormal. Our experiment demonstrates a significant result on multimodal imaging dataset. The proposed model can capture the complex distribution pattern for both normal and abnormal behaviors.

증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가 (Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers)

  • 이춘식;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제24권4호
    • /
    • pp.215-223
    • /
    • 1999
  • PWR 원전 증기발생기 수실의 방사선장 특성과 그곳에서 작업하는 종사자의 유효선량을 몬테칼로 시뮬레이션으로 평가하였다. 선원항으로는 고리1호기 증기발생기 방사화물 분석결과가 사용되었으며 유효선량 평가에는 MCNP4A코드와 MIRD형 성별 수학적 인형 모의피폭체가 사용되었다. 수실 내부 방사선장은 U튜브 영역에서 내려오는 방사선이 지배적이었으며 극각에 대해 근사적으로 코사인 분포를 나타내었다 유효선량률은 표준성인과 체격이 작은 성인(이 목적으로 15세 모의피폭체가 사용되었다.)의 경우 각각 36.22$mSvh^{-1}$와 37.06$mSvh^{-1}$로서 체격의 영향은 경미했다. 한편, 모의피폭체의 머리, 가슴 및 하복부에 해당하는 위치에서 평가된 조사선량률과 에너지스펙트럼에 대해 ICRU47에서 주어진 주위선량당량 환산계수를 이용해 평가한 등가선량률은 각각 119, 71, 및 58 $mSvh^{-1}$로 나타났다. 따라서 개인선량계 판독에서 얻는 심부선량 또는 유효선량은 앞서 계산한 유효선량률의 2배 정도가 될 것으로 보인다. 이 사실은 일반적인 개인선량계의 경사입사 방사선에 대한 과대/과소 평가 특성과 함께 비정규, 고선량률 방사선장에 종사하는 작업자의 선량계측 계획 및 결과의 해석에 매우 신중해야 함을 알려준다.

  • PDF