• Title/Summary/Keyword: Radiation spectrum

Search Result 509, Processing Time 0.024 seconds

Supplemental Lighting by HPS and PLS Lamps Affects Growth and Yield of Cucumber during Low Radiation Period (약광기 HPS와 PLS lamp를 이용한 오이의 보광재배효과)

  • Kwon, Joon-Kook;Yu, In-Ho;Park, Kyoung-Sub;Lee, Jae-Han;Kim, Jin-Hyun;Lee, Jung-Sup;Lee, Dong-Soo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.400-406
    • /
    • 2018
  • In this experiment the effect of supplemental lighting on the growth and yield of cucumber (Cucumis sativus L. 'Fresh') plants during low radiation period of winter season were investigated in glasshouses using common high-pressure sodium (HPS) lamps and newly developed plasma lighting system (PLS) lamps. Plants grown without supplemental lighting were considered as a control. Supplemental lighting was provided from November 20th, 2015 to March 15th, 2016 to ensure 14-hour photoperiod (natural+supplemental light), also lamps were operated automatically when the outside sun radiation levels were less than $100W{\cdot}m^{-2}$. Spectral analysis showed that HPS lamp had a discrete spectrum, lacked of the radiation in the 400-550 nm wave band (blue-green light), but had a high output in the orange-red region (550-650 nm). A higher red light output resulted in an increased red to far-red (R/FR) ratio in HPS lamp. PLS had a continuous spectrum and had a peak radiation in green region (490-550 nm). HPS has 12.6% lower output in photosynthetically active radiation (PAR) but 12.6% higher output in near infra-red (NIR) spectral regions compared to PLS. Both HPS and PLS lamps emitted very low levels of ultra-violet radiation (300-400 nm). Supplemental lighting both from HPS and PLS lamps increased plant height, leaf number, internode number and dry weight of cucumber plants compared to control. Photosynthetic activity of cucumber plants grown under two supplemental lighting systems was comparable. Number of fruits per cucumber plant (fruit weight per plant) in control, PLS, and HPS plots were 21.2 (2.9 kg), 38.7 (5.5 kg), and 40.4 (5.6 kg), respectively, thereby increasing yield by 1.8-1.9 times in comparison with control. An analysis of the economic feasibility of supplemental lighting in cucumber cultivation showed that considering lamp installation and electricity costs the income from supplemental lighting increased by 37% and 62% for PLS and HPS lamps, respectively.

LOCAL ANOMALIES AROUND THE THIRD PEAK IN THE CMB ANGULAR POWER SPECTRUM OF WMAP 7-YEAR DATA

  • Ko, Kyeong Yeon;Park, Chan-Gyung;Hwang, Jai-Chan
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.75-91
    • /
    • 2013
  • We estimate the power spectra of the cosmic microwave background radiation (CMB) temperature anisotropy in localized regions of the sky using the Wilkinson Microwave Anisotropy Probe (WMAP) 7-year data. We find that the north and south hat regions at high Galactic latitude ($|b|{\geq}30^{\circ}C$) show an anomaly in the power spectrum amplitude around the third peak, which is statistically significant up to 3. We try to explain the cause of the observed anomaly by analyzing the low Galactic latitude ($|b|$ < $30^{\circ}C$) regions where the galaxy contamination is expected to be stronger, and the regions weakly or strongly dominated byWMAP instrument noise. We also consider the possible effect of unresolved radio point sources. We find another but less statistically significant anomaly in the low Galactic latitude north and south regions whose behavior is opposite to the one at high latitude. Our analysis shows that the observed north-south anomaly at high latitude becomes weaker on regions with high number of observations (weak instrument noise), suggesting that the anomaly is significant at sky regions that are dominated by the WMAP instrument noise. We have checked that the observed north-south anomaly has weak dependences on the bin-width used in the power spectrum estimation, and on the Galactic latitude cut. We also discuss the possibility that the detected anomaly may hinge on the particular choice of the multipole bin around the third peak. We anticipate that the issue of whether or not the anomaly is intrinsic one or due to WMAP instrument noise will be resolved by the forthcoming Planck data.

A Study on the Distribution of Summer Water Temperature in Wando Using Time-Series Analysis and Numerical Experiments (시계열 분석 및 수치실험을 통한 완도의 하계 수온분포)

  • Jang, Chan-Il;Jeong, Da-Woon;Kim, Dong-Sun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.188-195
    • /
    • 2018
  • Time series analysis was conducted to identify the factors affecting short-term variation of water temperature in Wando. Spectrum analysis showed that air temperature peaks at diurnal period, while water temperature and tide level peak at both semi-diurnal and diurnal periods. Coherence between water temperature and the tide level presented 0.92 at semi-diurnal period. Numerical experiment were carried out to understand the spatio-temporal distribution of water temperature in the study area. Average water temperature difference between maximum ebb and flood was $0.3^{\circ}C$ in spring tide, but $0.13^{\circ}C$ in neap tide. The reason for the large difference in spring tide is that relatively cold water entered with strong tidal currents at flood tide and flowed out at ebb tide. Water temperature on coasts was higher than out at sea. This is because the depth in the coast is shallower than at sea, and water temperature increases rapidly due to solar radiation.

DEVELOPMENT OF LEAD SLOWING DOWN SPECTROMETER FOR ISOTOPIC FISSILE ASSAY

  • Lee, YongDeok;Park, Chang Je;Ahn, Sang Joon;Kim, Ho-Dong
    • Nuclear Engineering and Technology
    • /
    • v.46 no.6
    • /
    • pp.837-846
    • /
    • 2014
  • A lead slowing down spectrometer (LSDS) is under development for analysis of isotopic fissile material contents in pyro-processed material, or spent fuel. Many current commercial fissile assay technologies have a limitation in accurate and direct assay of fissile content. However, LSDS is very sensitive in distinguishing fissile fission signals from each isotope. A neutron spectrum analysis was conducted in the spectrometer and the energy resolution was investigated from 0.1eV to 100keV. The spectrum was well shaped in the slowing down energy. The resolution was enough to obtain each fissile from 0.2eV to 1keV. The detector existence in the lead will disturb the source neutron spectrum. It causes a change in resolution and peak amplitude. The intense source neutron production was designed for ~E12 n's/sec to overcome spent fuel background. The detection sensitivity of U238 and Th232 fission chamber was investigated. The first and second layer detectors increase detection efficiency. Thorium also has a threshold property to detect the fast fission neutrons from fissile fission. However, the detection of Th232 is about 76% of that of U238. A linear detection model was set up over the slowing down neutron energy to obtain each fissile material content. The isotopic fissile assay using LSDS is applicable for the optimum design of spent fuel storage to maximize burnup credit and quality assurance of the recycled nuclear material for safety and economics. LSDS technology will contribute to the transparency and credibility of pyro-process using spent fuel, as internationally demanded.

Electroluminescent Properties of White Light-Emitting Device Using Photoconductive Polymer and Anthracene Derivatives (광전도성 고분자와 안트라센 유도체를 이용한 백색 전계발광소자의 발광 특성)

  • Lee Jeong-Hwan;Choi Hee-Lack;Lee Bong
    • Korean Journal of Materials Research
    • /
    • v.15 no.8
    • /
    • pp.543-547
    • /
    • 2005
  • Organic electroluminescence devices were made from 1,4-bis-(9-anthrylvinyl)benzene (AVB) and 1,4-bis-(9-aminoanthryl)benzene (AAB) anthracene derivatives. Device structure was ITO/AVB/PANI(EB)/Al (multi-layer device) and ITO/AAB:DCM/Al(single-layer device). In these devices, AVB, polyaniline(emeraldine base) (PANI(EB)) and AAB were used as the emitting material. 4-(dicyanomethylene)-2-methyl-6-p-(dimethylamino)styryl-4H -pyran(DCM) was used as red fluorescent dopant. We studied change of fluorescence wavelength with concentration of DCM doped in AAB. The ionization potential (IP) and optical band gap (Eg) were measured by cyclic voltammetry and UV-visible spectrum. We compared with difference of emitting wavelength between photoluminescence and electroluminescence spectrum. In case of the multi-layer device, PANI and AVB EL spectra have similar wave pattern to each PL spectrum and when PAM and AVB were used at the same time, and multi-layer device showed that a balanced recombination and radiation kom PANI and AVB. In case of the single-layer device, with the increase of DCM concentration, the blue emission decreases and red emission increases. This indicates that DCM was excited by the energy transfer from AAB to DCM or the direct recombination at the dopant sites due to carrier trapping, or both. The device with $1.0wt\%$ DCM concentration gave white light.

Compare the Clinical Tissue Dose Distributions to the Derived from the Energy Spectrum of 15 MV X Rays Linear Accelerator by Using the Transmitted Dose of Lead Filter (연(鉛)필터의 투과선량을 이용한 15 MV X선의 에너지스펙트럼 결정과 조직선량 비교)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.80-88
    • /
    • 2008
  • Recent radiotherapy dose planning system (RTPS) generally adapted the kernel beam using the convolution method for computation of tissue dose. To get a depth and profile dose in a given depth concerened a given photon beam, the energy spectrum was reconstructed from the attenuation dose of transmission of filter through iterative numerical analysis. The experiments were performed with 15 MV X rays (Oncor, Siemens) and ionization chamber (0.125 cc, PTW) for measurements of filter transmitted dose. The energy spectrum of 15MV X-rays was determined from attenuated dose of lead filter transmission from 0.51 cm to 8.04 cm with energy interval 0.25 MeV. In the results, the peak flux revealed at 3.75 MeV and mean energy of 15 MV X rays was 4.639 MeV in this experiments. The results of transmitted dose of lead filter showed within 0.6% in average but maximum 2.5% discrepancy in a 5 cm thickness of lead filter. Since the tissue dose is highly depend on the its energy, the lateral dose are delivered from the lateral spread of energy fluence through flattening filter shape as tangent 0.075 and 0.125 which showed 4.211 MeV and 3.906 MeV. In this experiments, analyzed the energy spectrum has applied to obtain the percent depth dose of RTPS (XiO, Version 4.3.1, CMS). The generated percent depth dose from $6{\times}6cm^2$ of field to $30{\times}30cm^2$ showed very close to that of experimental measurement within 1 % discrepancy in average. The computed dose profile were within 1% discrepancy to measurement in field size $10{\times}10cm$, however, the large field sizes were obtained within 2% uncertainty. The resulting algorithm produced x-ray spectrum that match both quality and quantity with small discrepancy in this experiments.

  • PDF

Automatic Detection of Type II Solar Radio Burst by Using 1-D Convolution Neutral Network

  • Kyung-Suk Cho;Junyoung Kim;Rok-Soon Kim;Eunsu Park;Yuki Kubo;Kazumasa Iwai
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.213-224
    • /
    • 2023
  • Type II solar radio bursts show frequency drifts from high to low over time. They have been known as a signature of coronal shock associated with Coronal Mass Ejections (CMEs) and/or flares, which cause an abrupt change in the space environment near the Earth (space weather). Therefore, early detection of type II bursts is important for forecasting of space weather. In this study, we develop a deep-learning (DL) model for the automatic detection of type II bursts. For this purpose, we adopted a 1-D Convolution Neutral Network (CNN) as it is well-suited for processing spatiotemporal information within the applied data set. We utilized a total of 286 radio burst spectrum images obtained by Hiraiso Radio Spectrograph (HiRAS) from 1991 and 2012, along with 231 spectrum images without the bursts from 2009 to 2015, to recognizes type II bursts. The burst types were labeled manually according to their spectra features in an answer table. Subsequently, we applied the 1-D CNN technique to the spectrum images using two filter windows with different size along time axis. To develop the DL model, we randomly selected 412 spectrum images (80%) for training and validation. The train history shows that both train and validation losses drop rapidly, while train and validation accuracies increased within approximately 100 epoches. For evaluation of the model's performance, we used 105 test images (20%) and employed a contingence table. It is found that false alarm ratio (FAR) and critical success index (CSI) were 0.14 and 0.83, respectively. Furthermore, we confirmed above result by adopting five-fold cross-validation method, in which we re-sampled five groups randomly. The estimated mean FAR and CSI of the five groups were 0.05 and 0.87, respectively. For experimental purposes, we applied our proposed model to 85 HiRAS type II radio bursts listed in the NGDC catalogue from 2009 to 2016 and 184 quiet (no bursts) spectrum images before and after the type II bursts. As a result, our model successfully detected 79 events (93%) of type II events. This results demonstrates, for the first time, that the 1-D CNN algorithm is useful for detecting type II bursts.

Change in Trend in Various Clinico-Pathological Factors and Treatment Profile of Breast Cancer Patients: a Tertiary Cancer Centre Experience

  • Shankar, Abhishek;Roy, Shubham;Rath, GK;Kamal, Vineet Kumar;Bhandari, Menal;Kulshrestha, Rashi;Prasad, Neelam;Sachdev, Jaineet;Jeyaraj, Pamela
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.3897-3901
    • /
    • 2016
  • Background: Breast cancer is by far the most frequent cancer of women (23% of all cancers), ranking second overall when both sexes are considered together. Since there has been change in clinico-pathological factors and treatment profiles for breast cancer patients over the years, the present study to evaluate the change trends in India. Materials and Methods: A detailed analysis was carried out with respect to age, menopausal status, family history, disease stage, surgery performed, histopathology, hormone receptor status, and use of chemotherapy or hormonal therapy. Change in various clinico-pathological factors and treatments of breast cancer cases was recorded and analysed. Results: Mean age at presentation was found to be earlier in 2005-2006 compared with 1997-98 (p value: 0.046). More premenopausal women were diagnosed with breast cancer in 2005-2006 when this was compared with initial years of assessment (p value ${\leq}0.001$). When change in the receptor status was evaluated, we observed that there was a decrease in cases of ER and PR receptor positivity which was significant (p value: 0.007). Over the period of time, more f patients were not offered surgery initially in view of advanced disease when the two time periods were compared (p value: ${\leq}0.001$). There was a significant increase in patients who were initially offered neo-adjuvant chemotherapy in view of advanced disease at presentation (p value: ${\leq}0.001$). There was increasing number of patients who received palliative treatment for symptoms in 2005-2006 when compared to patients treated in 1997-98((p value: ${\leq}0.001$). Conclusions: Changes in mean age at presentation, premenopausal status, and stage at presentation have occurred over the years. More aggressive patterns of disease have become more common with early age at presentation and aggressive biological behaviour with receptor negative tumours.

Quality Correction for Ir-192 Gamma Rays in Air Kerma Strength Dosimetry Using Cylindrical Ionization Chambers (원통형 전리함을 이용한 Ir-192 선원에 대한 공기커마세기 측정 시 선질보정에 관한 연구)

  • Jeong, Dong-Hyeok;Kim, Jhin-Kee;Kim, Ki-Hwan;Oh, Young-Kee;Kim, Soo-Kon;Lee, Kang-Kyoo;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.30-36
    • /
    • 2009
  • The quality correction in the air kerma dosimetry for Ir-192 using farmer type ionization chambers calibrated by Co-60 quality is required. In this study we determined quality factor ($k_u$) of two ionization chambers of PTW-N30001 and N23333 for Ir-192 source using dosimetric method. The quality factors for energy spectrum of microSelectron were determined as $k_u$=1.016 and 1.017 for PTW-N30001 and N23333 ionization chambers respectively. We applied quality factors in air kerma dosimetry for microSelectron source and compared with reference values. As a results we found that the differences between reference air kerma rate and measured it with and without quality correction were about -0.5% and -2.0% respectively.

  • PDF

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.