• Title/Summary/Keyword: Radiation shielding and protection

Search Result 177, Processing Time 0.024 seconds

Measurements and Assessments on Shielding Performance of FCTC10 60Co Transport Container

  • Zhuang, Dajie;Zhang, Guoqing;Li, Guoqiang;Wang, Renze
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.310-314
    • /
    • 2016
  • Background: FCTC10 container is designed to transport $^{60}Co$ radioactive sources used in irradiation industry. It belongs to Type B(U) Category III (yellow) package when being loaded with a $^{60}Co$ source of $1.8{\times}10^5$ Ci. Materials and Methods: The container is constituted of shielding container, basket, protective cover and bracket. Shielding ability is provided mainly by stainless steel shells, tungsten alloy and lead among steel shells. Radiation level around the container has been calculated with both Monte Carlo simulations and measurements. Results and Discussion: It is proven that the shielding performance of the container fulfills the requirements in GB11806-2004 (Regulations for the safe transport of radioactive material, China Standard Press). Exposure doses to workers and to critical groups of public were calculated based on hypothetical exposure scene according to transport practice experience. Conclusion: The results show that doses to workers and public are less than the constraint dose considered in design, and the radiation level would be increased less than a factor of 2 under design basis accidents.

Performance Evaluation of Radiation Protection Apron's (방사선방어 앞치마 성능 평가)

  • Kang, Jong-gu;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.373-377
    • /
    • 2019
  • Radiation exposure is on the rise as the working hours of radiation workers increase. Accordingly, the importance of protection products for decreasing the dose of exposure has risen, and excellent X-ray shielding ability and light weight are required. The purpose of this study is to compare the Pb which use currently and other elements in order to reduce the exposure of workers to the most effective protection products. For experiment, we used the general X-ray equipment and angiography equipment, and obtained the Pb and apron's shielding rate. When the shielding rate of Pb and apron was compared in general X-ray equipment, the shielding rate was 95.1% for Pb 0.5 mm, 96.1% for apron 0.5 mmPb and 95.6% for Bi+W 0.5 mmPb. When compared the shielding rate of each aprons in angiography equipment, 0.5 mmPb apron was the highest as 96.4% and Bi+W 0.25 mmPb apron was the lowest as 90.2% at the 50 cm distance. The shielding rate of 0.5 mmPb apron was the highest as 95.7% and Bi+W 0.25 mmPb apron was the lowest as 85.9% at the 100 cm distance. As a result of evaluating the apron efficiency through this study, 0.5 mmPb apron showed the best shielding rate, but it was the heaviest apron. 0.35 mmPb apron and Bi+W 0.25 mmPb apron weighed light but had low shielding rate. Through the results of this experiment, it is recommended that radiation workers reduce radiation exposure by using more efficient protection products.

Enhancing Gamma-Neutron Shielding Effectiveness of Polyvinylidene Fluoride for Potent Applications in Nuclear Industries: A Study on the Impact of Tungsten Carbide, Trioxide, and Disulfide Using EpiXS, Phy-X/PSD, and MCNP5 Code

  • Ayman Abu Ghazal;Rawand Alakash;Zainab Aljumaili;Ahmed El-Sayed;Hamza Abdel-Rahman
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.184-196
    • /
    • 2023
  • Background: Radiation protection is crucial in various fields due to the harmful effects of radiation. Shielding is used to reduce radiation exposure, but gamma radiation poses challenges due to its high energy and penetration capabilities. Materials and Methods: This work investigates the radiation shielding properties of polyvinylidene fluoride (PVDF) samples containing different weight fraction of tungsten carbide (WC), tungsten trioxide (WO3), and tungsten disulfide (WS2). Parameters such as the mass attenuation coefficient (MAC), half-value layer (HVL), mean free path (MFP), effective atomic number (Zeff), and macroscopic effective removal cross-section for fast neutrons (ΣR) were calculated using the Phy-X/PSD software. EpiXS simulations were conducted for MAC validation. Results and Discussion: Increasing the weight fraction of the additives resulted in higher MAC values, indicating improved radiation shielding. PVDF-xWC showed the highest percentage increase in MAC values. MFP results indicated that PVDF-0.20WC has the lowest values, suggesting superior shielding properties compared to PVDF-0.20WO3 and PVDF-0.20WS2. PVDF-0.20WC also exhibited the highest Zeff values, while PVDF-0.20WS2 showed a slightly higher increase in Zeff at energies of 0.662 and 1.333 MeV. PVDF-0.20WC has demonstrated the highest ΣR value, indicating effective shielding against fast neutrons, while PVDF-0.20WS2 had the lowest ΣR value. The Monte Carlo N-Particle Transport version 5 (MCNP5) simulations showed that PVDF-xWC attenuates gamma radiation more than pure PVDF, significantly decreasing the dose equivalent rate. Conclusion: Overall, this research provides insights into the radiation shielding properties of PVDF mixtures, with PVDF-xWC showing the most promising results.

Evaluation of Tungsten Blended Filament Shields Made by 3D Printer in Radiography (일반촬영분야에서의 3D 프린터로 제작한 텅스텐 혼합 필라멘트 차폐체의 성능평가)

  • Yoon, Joon;Yoon, Myenog-Seong
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.615-621
    • /
    • 2021
  • In the medical field, radiation provides information for the diagnosis and treatment of diseases. As the use of radiation increases and the risk of exposure increases, interest in radiation protection is also rapidly increasing. Lead shielding material is mainly used, which has a risk of lead poisoning and absorption into the body. Tungsten mixed filament shielding sheets were fabricated with a size of 70 × 70 mm and a thickness of 1, 2, and 4 mm by using a 3D printer. In the general shooting experiment, the thickness of the shielding sheet is 1 ~ 5mm, the tube voltage is 60, 80, 100, 120 kVp and the tube current is 20, 40 mAs. In general photography, Tungsten showed better shielding rate compared to Brass, Copper, and Lead protective tools under all irradiation conditions, and in particular, Tungsten 5 mm showed 100% shielding rate. The 3D-printed tungsten mixed filament shielding is expected to be used as a new shield that can replace the existing lead protection tools as it shows a better shielding rate than the existing lead protection tools in Radiography.

Effect of Heat Treatment on Radiation Shielding Properties of Concretes

  • Singh, Vishwanath P.;Tekin, Huseyin O.;Badiger, Nagappa M.;Manici, Tubga;Altunsoy, Elif E.
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.20-28
    • /
    • 2018
  • Background: Heat energy produced in nuclear reactors and nuclear fuel cycle facilities interactions modifies the physical properties of the shielding materials containing water content. Therefore, in the present paper, effect of the heat on shielding effectiveness of the concretes is investigated for gamma and neutron. The mass attenuation coefficients, effective atomic numbers, fast neutron removal cross-section and exposure buildup factors. Materials and Methods: The mass attenuation coefficients, effective atomic numbers, fast neutron removal cross-section and exposure buildup factors of ordinary and heavy concretes were investigated using NIST data of XCOM program and Geometric Progression method. Results and Discussion: The improvement in shielding effectiveness for photon and reduction in fast neutron for ordinary concrete was observed. The change in the neutron shielding effectiveness was insignificant. Conclusion: The present investigation on interaction of gamma and neutron radiation would be very useful for assessment of shielding efficiency of the concrete used in high temperature applications such as reactors.

Personal Dosimeters Worn by Radiation Workers in Korea: Actual Condition and Consideration of Their Proper Application for Radiation Protection

  • Eunbi Noh;Dalnim Lee;Sunhoo Park;Songwon Seo
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.3
    • /
    • pp.162-166
    • /
    • 2023
  • Background: Assessment of the radiation doses to which workers are exposed can differ depending on the placement of dosimeters on the body. In addition, it is affected by whether the placement is under or over a shielding apron. This study aimed to evaluate the actual positioning of personal dosimeters on the body, with or without shielding aprons, among radiation workers in Korea. Materials and Methods: We analyzed the survey data, which included demographic characteristics, such as sex, age, occupation, work history, and placement of the personal dosimeter being worn, from a cohort study of Korean radiation workers. We assessed the use of personal dosimeters among workers, stratified by sex, age, working period, starting year of work, and occupation. Results and Discussion: Overall, high compliance (89.1% to 99.0%) with the wearing of dosimeters on the chest was observed regardless of workers' characteristics, such as age, sex, occupation, and work history. However, the placement of dosimeters, either under or over the shielding aprons, was inconsistent. Overall, 40.1% of workers wore dosimeters under their aprons, while the others wore dosimeters over their aprons. This inconsistency indicates that radiation doses are possibly measured differently under the same exposure conditions solely owing to variations in the placement of worn dosimeters. Conclusion: Although a lack of uniformity in dosimeter placement when wearing a shielding apron may not cause serious harm in radiation dose management for workers, the development of detailed guidelines for dosimeter placement may improve the accuracy of dose assessment.

Calculation of Shielding Rate of Radiation Protective Equipment Using the X-ray Spectrum of IPEM Report-78 (IPEM Report-78의 엑스선 스펙트럼을 이용한 방사선 방호장비의 차폐율 계산)

  • Han, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.755-760
    • /
    • 2021
  • In this study, the shielding rate of major X-ray protective equipment used in the medical environment was calculated using X-ray spectrum data emitted from the diagnostic X-ray generator of The Institute of Physics and Engineering(IPEM) Report-78, and the applicability of radiation protection was investigated. Radiation shielding rates were calculated through reduction rates of air-kerma and total intensity for lead apron (0.3 mmPb), thyroid shield (0.5 mmPb), lead goggles (0.5 mmPb), and lead glass (1.8, 2.7, 3.3 mmPb) used for diagnostic X-ray protection. As a result, the shielding rate calculated as the air kerma reduction rate ranged from 96.31 to 100% at 80 kV, and 90.35 to 100% at 120 kV. In addition, the results of this calculation were well matched with the results of previous studies measuring the actual shielding rate, and it is expected that the X-ray spectrum data of IPEM Report-78 can be used for radiation protection.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.

Radiation protective qualities of some selected lead and bismuth salts in the wide gamma energy region

  • Sayyed, M.I.;Akman, F.;Kacal, M.R.;Kumar, A.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.860-866
    • /
    • 2019
  • The lead element or its salts are good radiation shielding materials. However, their toxic effects are high. Due to less toxicity of bismuth salts, the radiation shielding properties of the bismuth salts have been investigated and compared to that of lead salts to establish them as a better alternative to radiation shielding material to the lead element or its salts. The transmission geometry was utilized to measure the mass attenuation coefficient (${\mu}/{\rho}$) of different salts containing lead and bismuth using a high-resolution HPGe detector and different energies (between 81 and 1333 keV) emitted from point sources of $^{133}Ba$, $^{57}Co$, $^{22}Na$, $^{54}Mn$, $^{137}Cs$, and $^{60}Co$. The experimental ${\mu}/{\rho}$ results are compared with the theoretical values obtained through WinXCOM program. The theoretical calculations are in good agreement with their experimental ones. The radiation protection efficiencies, mean free paths, effective atomic numbers and electron densities for the present compounds were determined. The bismuth fluoride ($BiF_3$) is found to have maximum radiation protection efficiency among the selected salts. The results showed that present salts are more effective for reducing the intensity of gamma photons at low energy region.