• 제목/요약/키워드: Radiation sensor

검색결과 426건 처리시간 0.027초

치과 방사선 발생기의 성능평가에 관한 연구 (Study on Performance Evaluation of Dental X-ray Equipment)

  • 정재은;정재호;강희두;이종웅;나극환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

고속 고정밀 중성자 측정을 위한 하드웨어 설계에 관한 연구 (A Study On Hardware Design for High Speed High Precision Neutron Measurement)

  • 장경욱;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.61-67
    • /
    • 2016
  • 본 논문에서는 중성자 방사선 측정을 위한 고속 고정밀 중성자 측정을 위한 하드웨어 설계방법을 제안한다. 제안된 고속 고정밀 중성자 측정 장치의 하드웨어 설계는 고성능 A/D 변환기를 사용하여 고정밀 고속의 아날로그 신호를 디지털 데이터로 변환할 수 있도록 구성된다. 중성자 센서를 사용하여 입사된 중성자 방사선 입자를 검출하고, 극저전류 정밀 측정 모듈을 통해 검출된 중성자 방사선을 보다 정밀하고 빠르게 측정하는 모듈을 설계한다. 고속 고정밀 중성자 측정을 위한 하드웨어 시스템은 중성자 센서부, 가변 고전압 발생부, 극저전류 정밀 측정부, 임베디드 시스템부, 디스플레이부 등으로 구성 된다. 중성자 센서부는 고밀도 폴리에틸렌을 통해 중성자 방사선을 검출하는 기능을 수행한다. 가변 고전압 발생부는 중성자 센서가 정상적으로 운영되기 위하여 발열 및 잡음 특성에 강인한 0 ~ 2KV 가변 고전압 발생장치의 기능을 수행한다. 극저전류 정밀 측정부는 중성자 센서에서 출력되는 고정밀 고속의 극저전류 신호를 고성능 A/D 변환기를 사용하여 정밀하고 빠르게 측정하고 아날로그 신호를 디지털 신호로 변환하는 기능을 수행한다. 임베디드 시스템부는 고속 고정밀 중성자 측정을 위한 중성자 방사선 측정 기능, 가변 고전압 발생장치 제어 기능, 유무선 통신 제어 기능, 저장 기능 등을 수행한다. 제안된 고속 고정밀 중성자 측정을 위한 하드웨어를 실험한 결과, 불확도, 중성자 측정 속도, 정확도, 중성자 측정 범위 등에서 기존의 장치보다 우수한 성능이 나타남을 확인할 수가 있다.

RF센서 위성시스템용 데이터 전송 컬러게이트 혼 안테나 설계 (Design of Data Transmission Corrugated Horn Antenna for RF Sensor Satellite System)

  • 전정익;최학근;임성빈;장재웅;김태윤
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.1-8
    • /
    • 2011
  • 본 논문에서는 RF센서 위성시스템용 데이터 전송 컬러게이트 혼 안테나를 설계하고 복사 특성을 확인하였다. 설계된 안테나는 8 ~ 8.4 GHz 에서 가장 높은 이득을 약 ${\pm}60^{\circ}$에서 형성하는 복사패턴을 갖도록 설계 제작하고 복사특성을 측정하였다. 설계된 안테나는 반사손실은 -15 dB 이하, 약 ${\pm}60^{\circ}$에서 이득은 5 dBi 이상으로 나타났다. 측정결과로부터 설계된 안테나는 RF센서 위성시스템용 데이터 전송 안테나로 사용될 수 있는 특성을 갖는 안테나로 확인되었다.

섬광검출을 위한 플라스틱광섬유에서의 체렌코프 빛 측정 및 제거 (Measurement and removal of a cerenkov light in a plastic optical fiber to detect a scintillating light)

  • 조동현;장경원;유욱재;신상훈;이봉수;박병기;조효성;김신
    • 센서학회지
    • /
    • 제17권2호
    • /
    • pp.100-105
    • /
    • 2008
  • The objectives of this study are to measure and to remove Cerenkov lights generated in a fiber-optic radiation sensor by a charge-coupled device. we have fabricated a fiber-optic radiation sensor which comprises an organic scintillator, a plastic optical fiber and a charge-coupled device. Charge-coupled device as a light measuring tool has many advantages which are easy in multi-dimensional measurements, high spatial resolution and relatively low cost.

광섬유 브래그 격자 센서의 고선량 방사선 효과 (High Total Dose Radiation Effects on Fiber Bragg Grating Sensors)

  • 김종열;이남호;정현규;김영웅;한원택
    • 한국정보통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.1425-1431
    • /
    • 2013
  • 게르마늄이 도핑된 실리카 코어에 페이즈 마스크를 이용하여 격자를 새긴 광섬유 브래그 격자 센서를 총 선량 23 kGy의 감마선을 조사하여 방사선에 의한 브래그 파장의 변화를 측정하였고, 방사선 조사 후에는 어닐링 특성을 평가하였다. 패키징된 FBG 센서의 경우, 방사선 조사동안 최대 91 pm의 브래그 파장변화가 나타났다. 또한 동일한 조건에서 패키징된 광섬유 브래그 격자 센서가 패키징 되지 않은 센서보다 방사선 민감도가 2배 이상 높게 나타났다.

원전 극한 환경적용을 위한 필드버스 통신망 요건 (Fieldbus Communication Network Requirements for Application of Harsh Environments of Nuclear Power Plant)

  • 조재완;이준구;허섭;구인수;홍석붕
    • 한국IT서비스학회지
    • /
    • 제8권2호
    • /
    • pp.147-156
    • /
    • 2009
  • As the result of the rapid development of IT technology, an on-line diagnostic system using the field bus communication network coupled with a smart sensor module will be widely used at the nuclear power plant in the near future. The smart sensor system is very useful for the prompt understanding of abnormal state of the key equipments installed in the nuclear power plant. In this paper, it is assumed that a smart sensor system based on the fieldbus communication network for the surveillance and diagnostics of safety-critical equipments will be installed in the harsh-environment of the nuclear power plant. It means that the key components of fieldbus communication system including microprocessor, FPGA, and ASIC devices, are to be installed in the RPV (reactor pressure vessel) and the RCS (reactor coolant system) area, which is the area of a high dose-rate gamma irradiation fields. Gamma radiation constraints for the DBA (design basis accident) qualification of the RTD sensor installed in the harsh environment of nuclear power plant, are typically on the order of 4 kGy/h. In order to use a field bus communication network as an ad-hoc diagnostics sensor network in the vicinity of the RCS pump area of the nuclear power plant, the robust survivability of IT-based micro-electronic components in such intense gamma-radiation fields therefore should be verified. An intelligent CCD camera system, which are composed of advanced micro-electronics devices based on IT technology, have been gamma irradiated at the dose rate of about 4.2kGy/h during an hour UP to a total dose of 4kGy. The degradation performance of the gamma irradiated CCD camera system is explained.

광학 필터를 이용한 광섬유 방사선 센서의 체렌코프 빛 제거 (Removal of Cerenkov Light in Fiber-optic Radiation Sensor Using Optical Filters)

  • 장경원;이봉수;조동현;김형식;이정한;이정환;김신;조효성
    • 한국광학회지
    • /
    • 제17권4호
    • /
    • pp.312-316
    • /
    • 2006
  • 본 연구에서는 유기 섬광체와 플라스틱 광섬유를 이용하여 치료용 전자선의 계측을 위한 광섬유 방사선 센서를 제작하였다. 또한, 선형가속기에서 발생되는 고 에너지 전자선에 의해 광섬유 방사선 센서를 이용한 전자선 계측에 있어 방해요소로 존재하는 체렌코프 빛을 감법 및 광학 필터링을 이용하여 제거하였고 두 가지방법들을 비교, 분석하였다.

고 에너지 광자선 계측용 2차원 광섬유 방사선 센서의 제작 및 특성분석 (Fabrication and Characterization of Two-dimensional Fiber-optic Radiation Sensor for High Energy Photon Beam Therapy Dosimetry)

  • 장경원;조동현;신상훈;김형식;이정한;이봉수;김신;조효성
    • 한국광학회지
    • /
    • 제18권4호
    • /
    • pp.241-245
    • /
    • 2007
  • 본 연구에서는 유기 섬광체와 플라스틱 광섬유를 이용하여 치료용 광자선의 계측을 위한 2차원 광섬유 방사선 센서를 제작하였다. 제작된 센서를 사용하여 광자선 조사야(Field size)와 에너지에 따른 선형가속기의 빔 분포도를 2차원적으로 측정하였으며 polymethylmethacrylate(PMMA)팬텀 내에서 깊이에 따른 섬광체의 광량을 측정하여 깊이선량 분포(Percent Depth Dose, PDD) 또한 2차원으로 측정하였다. 본 연구를 통하여 개발된 2차원 광섬유 방사선 센서는 고 분해능, 실시간 측정, 쉬운 보정 등 많은 장점을 가지고 있다.

플라스틱 광섬유를 이용한 초소형 의료용 방사선 센서 제작 (Fabrication of Miniature Radiation Sensor Using Plastic Optical Fiber for Medical Usage)

  • 황영묵;조동현;조효성;김신;이봉수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권1호
    • /
    • pp.9-12
    • /
    • 2005
  • 본 연구에서는 엑스선 또는 감마선 원거리 측정용 초소형 방사선 센서를 개발하기 위해서 발광 스펙트럼이 다른 여러 종류의 무기 섬광체를 이용하여 필름형태의 센서부를 제작하였고, 방사선으로부터 발생되는 섬광량을 광검출기 및 광파워미터로 측정하였다. 본 연구 결과, 개발 가능한 방사선 센서는 직경 1 mm의 플라스틱 광섬유를 사용하여 전자기파 장애로부터 간섭을 받지 않음과 동시에 원거리 측정 및 신속, 정확한 방사선 계측이 가능하고 초소형, 초경량의 특성을 지니기 때문에 방사선 치료 시 고 분해능의 방사선 계측이 가능할 것으로 기대된다.

  • PDF

범용 실리콘 방사선 센서를 이용한 우주방사선 선량계 개발 (Developments of Space Radiation Dosimeter using Commercial Si Radiation Sensor)

  • 천종규;김성환
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.367-373
    • /
    • 2023
  • 비행시 승무원이나 승객은 우주방사선과 공기나 비행기 기체와 반응하여 발생한 2차 산란선 등에 의해 피폭을 받게 된다. 항공기 승무원의 경우 우주기상 환경 시뮬레이션을 이용하여 계산된 피폭선량으로 방사선 안전관리를 적용받고 있다. 하지만, 태양활동이나 고도, 비행경로 등에 따라 피폭선량이 가변적이어서 계산법보다는 항로별 측정하는 것이 권고되고 있다. 본 연구에서는 범용 Si 센서와 다중채널파고분석기를 이용하여 우주방사선 선량을 측정할 수 있는 선량계를 개발하였다. 선량계산은 미우주항공국의 우주방사선 측정장비인 CRaTER(Cosmic Ray Telescope for the Effects of Radiation)의 알고리즘을 적용하였다. 표준교정시설에서 Cs-137 662 keV 감마선으로 에너지 및 선량교정을 시행하였으며, 실험 범위에서 선량률 의존성이 없음을 확인하였다. 제작된 선량계를 이용하여 2023년 5월 두바이 인천 구간의 국제선에서 직접 선량을 측정한 결과 국내 우주방사선 선량평가코드(KREAM; Korean Radiation Exposure Assessment Model for Aviation Route Dose)로 계산된 결과와 12% 이내로 비슷하게 나타났으며, 고도와 위도가 높아짐에 따라 계산 결과와 동일하게 선량이 증가하는 것을 확인하였다. 좀 더 많은 실증적 검증 실험이 요구되는 제한점은 있지만, 항공기 내 또는 개인 피폭선량 모니터링에 가성비가 우수한 선량계로 충분한 활용 가능성을 확인하였다.