• 제목/요약/키워드: Radiation sensor

검색결과 426건 처리시간 0.029초

LYSO 섬광체를 이용한 감마선 분광용 광섬유 방사선 센서의 개발 (Development of Fiber-optic Radiation Sensor Using LYSO Scintillator for Gamma-ray Spectroscopy)

  • 한기택;유욱재;신상훈;전다영;박장연;박병기;이봉수
    • 센서학회지
    • /
    • 제21권4호
    • /
    • pp.287-292
    • /
    • 2012
  • A fiber-optic radiation sensor was fabricated using a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer for gamma-ray spectroscopy. As an inorganic scintillator of the sensing probe, a LYSO crystal was used. In this study, we obtained the relationship between the photon counts of the fiber-optic radiation sensor and the activity of the radioactive isotope. In addition, the gamma-ray energy spectra were also measured using a fiber-optic radiation sensor to discriminate species of gamma-ray emitters.

고 선량율 감마선 조사에 따른 렌즈의 열화 (A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation)

  • 조재완;이준구;허섭;구인수;홍석붕
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

CCD 카메라를 이용한 방사선 탐지기의 영상화 기술 연구 (Design and Implementation of an optical wavelength analyzer)

  • 박성훈;박종원;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.811-813
    • /
    • 2013
  • 방사선을 측정하기 위해서는 여러 종류의 센서가 있다. 그 센서들 중에서 콜리메이터와 신틸레이터 통해 CCD 센서에서 감도나 센싱 방법을 사용하였다. 본 연구에서는 해상도가 높은 CCD 센서를 이용하여 방사선을 검출하는데, 신틸레이터 통해 CCD에 들어오는 영상에서 방사선에 반응하여 생기는 가시광선을 처리하여 방사선량을 측정하고 공간상에서 방사선이 가장 많이 나오는 포인터를 제시하는 것이다. 추후 영상을 스테레오 카메라 방식의 구현하여 방사선원까지 거리 산출하고 영상화하는 것이다.

  • PDF

CsI(T1) 방사선센서의 제작 및 분광특성 연구 (A Study on the Fabrication of CsI(T1) Radiation Sensor and its Spectroscopic Characteristics)

  • 권수일;신동호
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.44-50
    • /
    • 2002
  • 실험실에서 성장시킨 CsI(T1)섬광체를 이용하여 검출기를 설계 제작하고 분광 및 출력특성을 조사하여 핵분광과 진단방사선센서로서의 응용가능성을 타진해 보았다. CsI(T1)단결정은 수직 Bridgman성장장치를 이용하여 지름 11mm, 몰농도 0.001mo1%로 성장시키었다. 이 단결정을 광다이오드를 이용하여 방사선 센서로 제작한 후, $^{22}$ Na, /up 137/Cs, $^{30}$ Co 표준감마선원에 대한 에너지 분해능을 각각 측정하였으며 진단 X선 영역에 대한 출력특성도 측정하였다. $^{22}$ Na의 0.511 MeV 의 경우13.2%, $^{137}$Cs의 0.662 MeV의 경우 8.3%, 그리고 $^{60}$Co의 1.17 MeV와 1.332 MeV에 대해서는 각각 6.7%와 5.1%의 에너지 분해능을 얻었다. 또한 관전압 60kVp, 80kVp, 100kVp, 120kVp 에 대하여 5mAs부터 80mAs 까지 진단 X선영역에 대한 출력 선형성을 확인하였다.

  • PDF

광소자에 의한 일사량 측정 (Measurement of Radiation using Photo Diodes)

  • 이남호;백성호;김기복
    • 한국농공학회지
    • /
    • 제43권3호
    • /
    • pp.39-45
    • /
    • 2001
  • The purpose of this study is to develop an economic and practical radiation sensor using photo diodes which is useful for estimating ET in greenhouse environment. An electronic circuit was then designed. Out put signal of photo diode is amplified with a LM318 transistor and is displayed in a LCD with value from zero to 255. The output signal was compared with that of a ready-made pyranometer. The behavior of the photo diode radiation sensor was evaluated by increasing number of photo diodes. The sensor became more reliable with increased number of photo diodes. Developed radiometer was tested with calibrated relation between pyranometer radiation and photo diode output. It was showed that the photo diodes radiometer would be applicable for the greenhouse environment.

  • PDF

마이크로파 라디오미터 기술을 응용한 인체 감지 센서에 관한 연구 (A Study on a Human Body Detection Sensor Using Microwave Radiometer Technologies)

  • 손홍민;박홍균
    • 한국전자통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.333-340
    • /
    • 2015
  • 본 논문에서는 마이크로파 라디오미터의 기술을 응용한 수동형 마이크로파 인체 감지 센서를 제안한다. 제안된 센서는 고정된 배경 물체로부터 수신되는 복사전력의 인체에 의한 미약한 변화를 측정하여 감시 공간내의 인체를 감지한다. C-band 마이크로파 라디오미터를 설계 제작하여 인체에 의한 수신 복사전력의 변화를 측정하고 그 결과를 분석하여 제안한 센서의 유효성을 평가한다.

The Development of Gamma Energy Identifying Algorithm for Compact Radiation Sensors Using Stepwise Refinement Technique

  • Yoo, Hyunjun;Kim, Yewon;Kim, Hyunduk;Yi, Yun;Cho, Gyuseong
    • Journal of Radiation Protection and Research
    • /
    • 제42권2호
    • /
    • pp.91-97
    • /
    • 2017
  • Background: A gamma energy identifying algorithm using spectral decomposition combined with smoothing method was suggested to confirm the existence of the artificial radio isotopes. The algorithm is composed by original pattern recognition method and smoothing method to enhance the performance to identify gamma energy of radiation sensors that have low energy resolution. Materials and Methods: The gamma energy identifying algorithm for the compact radiation sensor is a three-step of refinement process. Firstly, the magnitude set is calculated by the original spectral decomposition. Secondly, the magnitude of modeling error in the magnitude set is reduced by the smoothing method. Thirdly, the expected gamma energy is finally decided based on the enhanced magnitude set as a result of the spectral decomposition with the smoothing method. The algorithm was optimized for the designed radiation sensor composed of a CsI (Tl) scintillator and a silicon pin diode. Results and Discussion: The two performance parameters used to estimate the algorithm are the accuracy of expected gamma energy and the number of repeated calculations. The original gamma energy was accurately identified with the single energy of gamma radiation by adapting this modeling error reduction method. Also the average error decreased by half with the multi energies of gamma radiation in comparison to the original spectral decomposition. In addition, the number of repeated calculations also decreased by half even in low fluence conditions under $10^4$ ($/0.09cm^2$ of the scintillator surface). Conclusion: Through the development of this algorithm, we have confirmed the possibility of developing a product that can identify artificial radionuclides nearby using inexpensive radiation sensors that are easy to use by the public. Therefore, it can contribute to reduce the anxiety of the public exposure by determining the presence of artificial radionuclides in the vicinity.

고감도 보급형 방사선 측정센서 모듈 개발 (Development of High-Sensitivity and Entry-Level Radiation Measuring Sensor Module)

  • 오승진;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.510-514
    • /
    • 2022
  • 본 논문에서는 고감도 보급형 방사선 측정센서 모듈 개발을 제안한다. 제안하는 측정센서 모듈은 섬광체+광증배소자(SiPM) 센서 최적화 구조설계, 센서 드라이버용 증폭과 필터 및 제어회로 설계, 근거리 통신을 포함한 제어회로 설계, 센서 기구설계 및 제작, 시제품에 적용되는 GUI 개발 등으로 구성된다. 섬광체+광증배소자(SiPM) 센서 최적화 구조 설계는 센서 구조 설계를 위한 섬광체와 광증배소자(SiPM)의 특성을 확인하여 설계한다. 센서 드라이버용 증폭과 필터 및 제어회로 설계는 SiPM을 이용하여 섬광체로 방사선에 의해 발생하는 미세 섬광신호를 처리하도록 설계한다. 근거리 통신을 포함한 제어회로 설계는 근거리 무선통신 기능을 지원하기 위한 MCU 설계 및 유선 통신 지원을 통해 데이터 전송이 가능하도록 설계를 수행한다. 센서 기구설계 및 제작은 플라스틱 섬광체에서 발생한 미세 섬광 신호를 광증배소자(SiPM)에 전달하기 위해 플라스틱 섬광체 외부에 반사지(미러링)를 감싸 발생한 섬광이 반사되어 효율을 높이도록 설계한다. 시제품에 적용되는 GUI 개발은 각 화면에 따라 상단에 날짜와 시간을 표현하며, 측정단위 및 시간, 초, 알람 레벨, 통신상태, 배터리 용량 등이 표현되도록 한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 방사선량 측정 범위가 30𝜇Sv/h ~ 10mSv/h로 측정되어서, 현재 국내외에서 상용으로 판매되는 제품들 중에서 최고수준 범위와 같은 결과가 산출되었다. 또한, ±7.4%의 측정 불확도가 측정되어서 국제 표준인 ±15% 이하에서 정상동작 됨이 확인되었다

주간 활용 별센서의 별 감지가능성 분석 (Star Detectability Analysis of Daytime Star Sensor)

  • 나자경;이유;김용하
    • 한국항공우주학회지
    • /
    • 제33권9호
    • /
    • pp.89-96
    • /
    • 2005
  • 이 논문에서는 주간 항법용 별센서의 실제 활용을 목적으로 주간 대기 조건과 주간 별 감지 가능성을 논한다. 주간동안의 대기 자료를 구하기 위해 표준 대기 모델(LOWTRAN 7)을 사용했으며 그 모델로부터 배경하늘에 대한 복사와 대기투과도를 구하였다. 대기 복사량을 감소시키기 위해 광학 필터를 장착한 별센서를 가정했으며 태양 복사 효과를 나타내기 위해 별센서와 태양 사이의 다양한 분리각을 설정하였다. 별센서의 FOV에 대한 고려로서, 하늘 배경 복사의 변화와 감지가능한 별의 개수 밀도를 분석하였다. 또한 요구되는 신호 대 잡음비를 얻기 위한 노출시간과 별센서의 주간 활용 한계로서 작용하는 CCD의 복사에 의한 전자 수를 계산하였다.

유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의 상대 깊이 선량율 측정 (Measurements of relative depth dose rates for a brachytherapy Ir-192 sourceusing an organic scintillator fiber-optic radiation sensor)

  • 신상훈;장경원;조동현;유욱재;서정기;이봉수;문주현;김신;박병기
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.462-469
    • /
    • 2008
  • In this study, we have fabricated a fiber-optic radiation sensor using an organic scintillator and plastic optical fiber for brachytherapy dosimetry. Also, we have measured relative depth dose rates of Ir-192 source using a fiber-optic sensor and compared them with the results obtained using a conventional EBT film. Cerenkov lights which can be a noise in measuring scintillating light with a fiber-optic sensor are measured and eliminated by using of a background optical fiber. It is expected that a fiber-optic radiation sensor can be used in brachytherapy dosimetry due to its advantages such as a low cost, simple usage and a small volume.