• 제목/요약/키워드: Radiation sensor

검색결과 427건 처리시간 0.023초

고체비적검출기를 이용한 500 MeV/u 철 이온의 선에너지전이 교정 (LET Calibration of Fe 500 MeV/u Ions using SSNTD)

  • 김성환
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.41-45
    • /
    • 2016
  • In this study, LET (Linear Energy Transfer) calibration of CR-39 SSNTD (Solid State Nuclear Track Detector) was performed using 500 MeV/u Fe heavy ions in HIMAC (Heavy Ion Medical Accelerator) for high LET radiation dosimetry. The irradiated CR-39 SSNDT were etched according JAXA (Japan Aerospace Exploration Agency) etching conditions. And the etched SSNTD were analyzed by using Image J. Determined dose-mean lineal energy ($\overline{y_D}$) of 500 MeV/u Fe is about 283.3 keV/um by using the CR-39 SSNTD. This value is very similar result compare to the results calculated by GEANT4 Monte Carlo simulation and measured with TEPC active radiation detector. We confirmed that the CR-39 SSNTD was useful for high LET radiation dosimetry such as heavy iron ions.

Cortex-A9 기반 휴대용 방사선 검출장치에서의 알람 알고리즘 구현 (Realization of alarm algorithm on portable radiation detection device based on Cortex-A9)

  • 남혜진;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.387-390
    • /
    • 2014
  • 본 논문에서는 Cortex-A9을 기반으로 한 휴대용 방사선 검출기에 알람 알고리즘을 적용하여 사용자의 안전을 위한 연구를 제안하고자 한다. 센서의 신호를 아날로그 보드를 통해서 분석에 용이하도록 변형시키고, Cortex-A9 플랫폼에서는 결과를 출력하고, 방사선 검출을 LED와 Buzzer로 알리는 알람기능을 구현하여 사용자의 안전을 보장한다.

  • PDF

방사선 환경에 강인한 CMOS카메라에 관한 연구 (A Study on the CMOS Camera robust to radiation environments)

  • 백동현;김배훈
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권1호
    • /
    • pp.27-34
    • /
    • 2020
  • 방사선원을 이용하는 곳에는 사람의 접근이 제한되나 관측장비는 노출됨으로 방사선에 강하여야 한다. 이에따라 카메라차폐 구조설계에 필요한 물질로 비중과 용융점이 가장 높은 텅스텐과 가장 낮은 납을 선정하여 코발트 60 방사선 소스에 대한 선량을 1/8까지 감소시킬 경우 Tu는 체적 432.6cm3, 두께 2.4cm이었고, Pb는 체적 961cm3, 두께 3.6cm이었다. 이를 적용하여 CMOS Image센서를 적용한 카메라모듈 및 내방사선 차폐구조의 하우징과 방사선에 강한 CMOS카메라를 제작하였다. 최적화된 차폐두께의 선정을 위한 실험에서 생존한 헤드분리형2M AHD형 카메라(①번)를 적용한 결과 카메라 및 아답터등 연관설비에 대한 차폐가 이루어지면 1.88×106rad 이상의 선량에서도 잘 동작함을 확인하였다. 따라서 고방사선에 적용할 수 있는 카메라 기술력확보와 사업성을 기대할 수 있다.

강릉 지역에서 자동 전운량 장비와 GWNU 태양 복사 모델을 이용한 지표면 일사량 분석 (An Analysis of Global Solar Radiation using the GWNU Solar Radiation Model and Automated Total Cloud Cover Instrument in Gangneung Region)

  • 박혜인;조일성;김부요;지준범;이규태
    • 한국지구과학회지
    • /
    • 제38권2호
    • /
    • pp.129-140
    • /
    • 2017
  • 이 연구에서는 지표 관측 자료와 위성 자료 그리고 GWNU 단층 복사 모델을 이용하여 맑은 상태의 전천 일사량을 계산하였으며, 전운량에 따라 관측 및 모델의 일사량 값을 비교 분석하였다. 연구 자료는 2012년 강릉원주대학교 복사 관측소의 전천 일사량, 기온, 기압, 습도, 에어로졸 등의 관측 자료와 OMI 센서의 오존전량 자료 그리고 구름의 유무 및 전운량을 판단하기 위하여 자동 전운량 장비인 Skyview 자료를 이용하였다. 전운량이 0 할인 맑은 날의 경우 관측 값과 모델 값이 0.98로 높은 상관계수를 나타내었으나 RMSE가 $36.62Wm^{-2}$로 비교적 높게 나타났다. 이는 Skyview 장비가 얇은 구름이나 박무 및 연무 등의 기상상태를 판단하지 못하였기 때문이다. 흐린 날의 경우 구름의 영향을 보정하기 위해 전운량과 두 값의 차에 대한 비율을 이용한 회귀식을 복사 모델에 적용하였으며, 장비의 오탐지를 제외한 경우 상관계수가 0.92로 높은 상관성을 보였으나 RMSE가 $99.50Wm^{-2}$으로 높은 값을 보였다. 더 정확한 분석을 위해서는 직달 성분의 차폐 유무 및 구름 광학 두께를 포함한 다양한 구름 요소의 추가적인 분석이 요구된다. 이 연구결과는 분 또는 시간에 따른 일사량을 산출하여 일사량이 관측되지 않는 지역에서 유용하게 사용될 수 있다.

Chalcogenide 광섬유를 이용한 호흡측정 센서 개발을 위한 기초 연구 (Feasibility study on the development of respiration sensor using a chalcogenide optical fiber)

  • 유욱재;조동현;장경원;오정은;이봉수;탁계래
    • 센서학회지
    • /
    • 제16권5호
    • /
    • pp.331-336
    • /
    • 2007
  • In this study, we have fabricated an infrared optical fiber based sensor which can monitor the respiration of a patient. The design of a chalcogenide optical fiber based sensor is suitable for insertion into a high electro-magnetic field environment because the sensor consists of low cost and compact mid-infrared components such as an infrared light source, a chalcogenide optical fiber and a thermopile sensor. A fiber-optic respiration sensor is capable of detecting carbon dioxide ($CO_{2}$) in exhalation of a patient using the infrared absorption characteristics of carbon gases. The modulated infrared radiation due to the presence of carbon dioxide is guided to the thermopile sensor via a chalcogenide receiving fiber. It is expected that a mid-infrared fiber-optic respiration sensor which can be developed based on the results of this study would be highly suitable for respiration measurements of a patient during the procedure of an MRI.

Environmental Monitoring Using Comfort Sensing System

  • Na, Dae-Suk;Kang, Jeong-Ho;Park, Se-Kwang
    • 센서학회지
    • /
    • 제12권1호
    • /
    • pp.24-33
    • /
    • 2003
  • This research is about a comfort sensing system for human environmental monitoring using a one-bodied humidity and temperature sensor and an air flow sensor. The thermal comfort that a human being feels in indoor environment has been known to be influenced mostly by six parameters, i.e. air temperature, radiation, air flow, humidity, activity level and clothing thermal resistance. Considering an environmental monitoring, we have designed and fabricated a one-bodied humidity and temperature sensor and an air flow sensor that detect air relative humidity, temperature and air flow in human environment using surface micromachining technologies. Micro-controller calculates a PMV (predicted mean vote) and CSV (comfort sensing vote) with sensing signals and display a PMV on LCD (liquid crystal display) for human comfort on indoor climate. Our work has demonstrated that a comfort sensing system can provide an effective means of measuring and monitoring the indoor comfort sensing index of a human being. Experimental results with simulated environment clearly suggest that our comfort sensing system can be used in many applications such as air conditioning system, feedback controlling in automobile, home and hospital etc..

주변 온도 영향에 따른 비분산 적외선 가스센서의 출력 특성 해석 (Analysis of Output Voltage Properties of Non-dispersive Infrared Gas Sensors According to Ambient Temperatures)

  • 박한길;이승환
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.294-299
    • /
    • 2018
  • This article describes the output properties of non-dispersive infrared carbon dioxide($CO_2$) sensors resulting from the changes in ambient temperatures. After the developed sensor module was installed inside the gas chamber, the temperature was set to 267 K, 277 K, 300 K, and 314 K, and the concentrations of $CO_2$ gas were increased from 0 to 5,000 ppm. Then, the output voltage at each concentration was obtained. Through these experimental results, two observations were made. First, both the $CO_2$ sensor and the reference sensor showed an increase in the output voltages as the temperature rose from 0 ppm, Second, the full scale outputs of the $CO_2$ sensor grew as the temperature increased. The output characteristics were analyzed based on two factors: change in the radiant energy of the infrared light source and change in the absorptivity of $CO_2$ gas according to the ambient temperature. Additionally, temperature compensation methods were discussed.

Packet-Level Scheduling for Implant Communications Using Forward Error Correction in an Erasure Correction Mode for Reliable U-Healthcare Service

  • Lee, Ki-Dong;Kim, Sang-G.;Yi, Byung-K.
    • Journal of Communications and Networks
    • /
    • 제13권2호
    • /
    • pp.160-166
    • /
    • 2011
  • In u-healthcare services based on wireless body sensor networks, reliable connection is very important as many types of information, including vital signals, are transmitted through the networks. The transmit power requirements are very stringent in the case of in-body networks for implant communication. Furthermore, the wireless link in an in-body environment has a high degree of path loss (e.g., the path loss exponent is around 6.2 for deep tissue). Because of such inherently bad settings of the communication nodes, a multi-hop network topology is preferred in order to meet the transmit power requirements and to increase the battery lifetime of sensor nodes. This will ensure that the live body of a patient receiving the healthcare service has a reduced level of specific absorption ratio (SAR) when exposed to long-lasting radiation. We propose an efficientmethod for delivering delay-intolerant data packets over multiple hops. We consider forward error correction (FEC) in an erasure correction mode and develop a mathematical formulation for packet-level scheduling of delay-intolerant FEC packets over multiple hops. The proposed method can be used as a simple guideline for applications to setting up a topology for a medical body sensor network of each individual patient, which is connected to a remote server for u-healthcare service applications.

광섬유 센서를 이용한 초음파 검출 (A Fiber-Optic Sensor for Ultrasonic Measurement)

  • 심승환;이광식;이동인;이상훈;김달우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1715-1717
    • /
    • 2001
  • The partial-discharge(PD) is accompanied by physical and chemical phenomena, such as heat, light, noise gas, chemical transformation, electric current, and electromagnetic radiation. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Now, a fiber-optic sensor for detecting ultrasonics is suggested for the on line measurement system with high accuracy. This paper describes the basic principles fiber-optic sensor for ultrasonic measurement.

  • PDF