• 제목/요약/키워드: Radiation sensor

검색결과 427건 처리시간 0.032초

방사선 치료위치 검증을 위한 다이오드 검출기의 특성에 관한 연구 (A Study on Characteristics of Diode Detecter for Verification of Radiation Therapy)

  • 이동훈;김윤종;지영훈;이동한;홍승홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.106-109
    • /
    • 2000
  • The diode characteristics for therapy radiation sensor have been studied by irradiating therapy radiation from the MM22 microtron accelerator. Signal processing has been performed in the pulse mode which can process the signal fast. We have designed integrator, peak detector and synchronization circuit to detect diode signal in the pulse mode for implementation of portal image. We also read the diode signal by A/D board and displayed the peak value with LabView program. Because the quality of portal image obtained by film in the case of therapy radiation is much worse than that of diagnostic film, Digital radiography system by rectifier diode detector was suggested for portal Image.

  • PDF

방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작 (Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent)

  • 김정호;박혜민;주관식
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

다종 감마선 공간분포 측정을 위한 고감도 검출센서 및 탐지모듈 개발 (Development of High-Sensitivity Detection Sensor and Module for Spatial Distribution Measurement of Multi Gamma Sources)

  • 황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.705-707
    • /
    • 2017
  • 스테레오기반의 공간방사선 탐지장치는 방사선원에 대한 공간분포정보 뿐만 아니라 탐지장치로부터 선원까지의 거리정보를 얻을 수 있어 기존 방사선 영상화 장치보다 선원에 대한 효율적인 정보를 제공한다. 또한 감마선원의 스펙트럼 및 종류에 대한 정보를 고속으로 제공하기 위해서는 감도가 높은 고감도 검출센서가 필요하며 고선량에서의 포화되는 현상을 해소할 수 있는 기법이 필요하다. 본 논문에서는 다종 감마선 공간분포 측정을 위해 고감도 센서를 구성하고, 검출모듈의 기능을 개선하여 고선량에서의 포화상태를 해소함으로써 단일센서로 탐지범위 증대를 위한 연구를 수행하였다. 본 논문의 결과는 향후 스테레오기반의 감마선 탐지장치의 성능개선을 위해 활용될 것이다.

  • PDF

인체 감지용 소형 마이크로파 센서 수신기의 설계 및 제작 (Design and Implementation of the Small Size Microwave Sensor Receiver for Human Body Detection)

  • 손홍민;최현호
    • 한국전자파학회논문지
    • /
    • 제27권4호
    • /
    • pp.403-406
    • /
    • 2016
  • 본 논문에서는 인체 감지용 수동형 마이크로파 센서의 실용화를 위한 소형 수신기의 설계, 제작에 관해 기술한다. 먼저 기존의 5.1 GHz 센서에 의한 인체 감지 측정 실험 데이터를 이용하여 센서 수신기의 요구사항 및 설계 사양을 도출하였으며, 이를 토대로 소형 수신기를 설계, 제작하였다. 제작한 소형 수신기 센서로 실험실에서의 인체 감지 측정 실험 결과, 안테나로부터 4 m 거리에 있는 인체까지 감지가 확인되었다. 제작된 소형 수신기는 기존 수신기에 비해 크기는 약 60 %, 소비전력은 40 % 감소된 소형경량 저소비전력으로 구현함으로써 실용성을 높였다.

In vivo verification of regional hyperthermia in the liver

  • Noh, Jae Myoung;Kim, Hye Young;Park, Hee Chul;Lee, So Hyang;Kim, Young-Sun;Hong, Saet-Byul;Park, Ji Hyun;Jung, Sang Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • 제32권4호
    • /
    • pp.256-261
    • /
    • 2014
  • Purpose: We performed invasive thermometry to verify the elevation of local temperature in the liver during hyperthermia. Materials and Methods: Three 40-kg pigs were used for the experiments. Under general anesthesia with ultrasonography guidance, two glass fiber-optic sensors were placed in the liver, and one was placed in the peritoneal cavity in front of the liver. Another sensor was placed on the skin surface to assess superficial cooling. Six sessions of hyperthermia were delivered using the Celsius TCS electro-hyperthermia system. The energy delivered was increased from 240 kJ to 507 kJ during the 60-minute sessions. The inter-session cooling periods were at least 30 minutes. The temperature was recorded every 5 minutes by the four sensors during hyperthermia, and the increased temperatures recorded during the consecutive sessions were analyzed. Results: As the animals were anesthetized, the baseline temperature at the start of each session decreased by $1.3^{\circ}C$ to $2.8^{\circ}C$ (median, $2.1^{\circ}C$). The mean increases in temperature measured by the intrahepatic sensors were $2.42^{\circ}C$ (95% confidence interval [CI], 1.70-3.13) and $2.67^{\circ}C$ (95% CI, 2.05-3.28) during the fifth and sixth sessions, respectively. The corresponding values for the intraperitoneal sensor were $2.10^{\circ}C$ (95% CI, 0.71-3.49) and $2.87^{\circ}C$ (1.13-4.43), respectively. Conversely, the skin temperature was not increased but rather decreased according to application of the cooling system. Conclusion: We observed mean $2.67^{\circ}C$ and $2.87^{\circ}C$ increases in temperature at the liver and peritoneal cavity, respectively, during hyperthermia. In vivo real-time thermometry is useful for directly measuring internal temperature during hyperthermia.

동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발 (Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study)

  • 이석;이상훈;신동호;양대식;최명선;김철용
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.122-125
    • /
    • 2004
  • 폐, 간 등의 상 복부에 위치한 종양의 방사선 조사 체적은 호흡에 의한 종양의 이동을 포함하기 때문에 방사선 조사체적이 증가되어 방사선 독성 및 정상조직 선량이 증가하게 된다. 이러한 문제점을 극복하기 위해 동 팬텀과 초음파센서를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득하고, 획득한 데이터의 역 값을 이용해 환자침대를 조절해줄 수 있는 호흡운동 조절 방사선치료 기술을 개발하고자 한다. 호흡운동에 의한 환자 체표면의 움직임을 평가하기 위해 제작한 팬텀은 조정기(BS II, 20 Mhz, 8K Byte), 센서(Ultra-Sonic, range 3 cm${\sim}$3 m), Computer(RS232C), Servo Motor (Torque 2.3 Kg)등으로 구성하였고, 제어와 구동을 위한 획득-보정-분석 프로그램을 작성하였다. 최대 2 cm 범위 내에서 팬텀을 움직이게 하였고, 팬텀의 움직임과 보정이 순차적으로 일어나도록 프로그램 하였으며, x, y, z가 연속적으로 움직이도록 구성하였다. 임의의 움직임 데이터(유격이 2 cm이 되도록 하여 3차원 데이터 형태)를 입력하여 동 팬텀을 조정하고, 동시에 팬텀 움직임을 초음파 센서를 이용하여 획득한 후, 두 데이터 간의 비교, 분석을 시행하였다. 이후 쥐(Guinea-pig, about 500g)를 이용하여 호흡운동에 의한 환자 체표면의 움직임을 획득한 후 획득한 데이터의 역 값으로 팬텀을 구동시킴으로써 실시간 호흡운동 조절 방사선치료 기술을 평가하였다. 팬텀 실험에서 3 차원 입력데이터에 대한 팬텀 보정 데이터 간의 정확성을 시간에 대한 거리 값으로 비교한 결과 ${\pm}$1% 이내의 정확성을 알 수 있었고, 이에 필요한 보정시간은 2.34 ${\times}$ 10-4 초임을 알 수 있었다. 또한 동물 실험에서도 동일한 방법으로 시간에 대한 거리 그래프와 획득-보정 간의 지연 시간 등을 분석한 결과 팬텀 데이터와 같은 결과를 얻을 수 있었다. 팬텀, 동물 실험 모두에서 시간에 대한 거리 값과 각각의 경우에 획득-보정 간의 지연 시간을 분석한 결과 데이터 값은 ${\pm}$1%이내에서 일치하였으며, 데이터 획득-보정 지연 시간은 2.34 ${\times}$ 10-4 초 이내 즉, 실시간으로 얻을 수 있어 새로운 호흡운동 조절 방사선치료 기술의 임상적용에의 가능성을 확인할 수 있었다.

  • PDF

반도체에 대한 과도방사선 방호기술연구 (Study of a Protection Technology to the Transient Radiation for the Semiconductors)

  • 이남호;오승찬;정상훈;황영관;김종열
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.1023-1026
    • /
    • 2013
  • 위 펄스형 방사선에 노출된 전자장비는 전자소자 내부에서 발생되는 전자-정공쌍(EHP)과 이들이 형성한 순간 광전류로 Upset, Latchup, Burn out 과 같은 다양한 피해를 입게 된다. 이와같은 손상은 군무기체계나 우주항공 장비의 경우 군전력 손실이나 장비의 기능정지로 나타나 국가적으로 큰 손실을 초래할 수 있다. 본 연구에서는 펄스형 감마방사선으로 부터 전자장비/소자를 보호하기 위한 방호기술개발의 일환으로 '방사선 감지 및 제어장치'를 구현하고 대표적으로 군장비에 사용되는 전자소자에 대한 기능검증을 시도하였다. 펄스 방사선에 Latchup 및 Burn out 손상특성을 나타내는 LM118 소자에 개발한 '방사선 감지 및 제어장치'를 적용하여 펄스방사선 조사시험을 수행한 결과 LM118이 안전하게 보호됨을 확인하였다.

  • PDF

방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구 (Study of Radiation Mapping System for Water Contamination in Water System)

  • 나원경;김한수;연제원;이레나;하장호
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.