• Title/Summary/Keyword: Radiation sensor

Search Result 426, Processing Time 0.024 seconds

A Study on the Noise Emission Characteristics of Turbo Axial Flow Fan by Experimental Method (터보형송풍기의 소음 방사특성에 관한 실험적 연구)

  • 김동규;백종진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.271-277
    • /
    • 2003
  • Recently as the environmental noise getting influential social problem, it is the fact that the demand on noise reduction increases with the advance of the standard of living. Therefore increasing the interest on the noise in common, it is eagerly demanded that the endeavour for reducing the noise of the rotating machinery, especially the machinery related a flowing including the household electric products, which is pointed out the primary noise source in environment. As proceeding study for fan noise, theory of fan noise property is arranged and this control method is shown. Blade passage noise of total noise spectrum. Thus in the aspect of noise reduction, noise source and identification of noise radiation characteristics of axial flow fan are demanded in detail. The sound source is analyzed by using sound pressure and sound intensity. In that time, synchronization of axial flow fan using optical sensor is executed, and to identify the location of exact noise source in the fan profile determination of recording time is proposed. In the rotating of tan, it is explained that the location of noise source exists in and by the directivity, the noise radiation pattern of axial flow fan is determined and the flow of sound is visualized in the figure of contour mapping.

  • PDF

Development of a Wireless Gamma-ray Probe for Diagnosing and Evaluation of its Effectiveness (진단용 무선 감마선 프로브 개발 및 유용성 평가)

  • Park, Hyemin;Joo, Koansik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.173-181
    • /
    • 2015
  • We developed a wireless gamma-ray probe based on radiation photon counting method to diagnose and detect remaining lesions after surgery, and its effectiveness was evaluated using calibration sources and a phantom. The probe was designed and miniaturized using a semi-conductor-based radiation sensor, and a Bluetooth remote communication module was used to implement the wireless diagnosis and detection system. Moreover, a remote monitoring system was implemented to monitor affected areas during diagnosis and surgery. To assess the effectiveness of the developed probe in this study, calibration sources $^{57}Co$, $^{133}Ba$, $^{22}Na$ and $^{137}Cs$ and a chicken breast phantom were used. Furthermore, the probe's detection response to gamma ray was confirmed through evaluation. Its clinical applicability was verified by assessing the response linearity and detection direction according to gamma-ray intensity, as well as the detection efficiency according to the depth of the gamma source in the phantom.

Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application (비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교)

  • Kim, Byung-Hyuk;Jung, Han;Kim, Young-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.

A Study on the Bundle-type Scintillating Fiber and Tapered Scintillator Radiation Sensors for Monitoring of Radioactive Wastes Disposal Sites (방사성폐기물 처분장 감시를 위한 다발형 광섬유 센서 및 Tapered 섬광체 방사선 센서에 관한 연구)

  • 김계홍;박재우
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.233-238
    • /
    • 2003
  • Several types of gamma-ray sensors were constructed by packing different numbers of fibers into aluminum tubes, and tested to detect the $^137Cs$ gamma ray. It has been found from this investigation that tapered fibers can be more efficient to collect the lights produced inside the sensor and transfer them into the transmitting fiber in order to predict the functioning of the tapered fiber, tapered plastic scintillators, composed of polystyrene with minute amount of dPOPOP and PPO or dPBD, were fabricated and tested for the detection of gamma rays from 1.0 1.5 3.0 5.0 ${\mu}Ci$ $^137Cs$ sources, and the pulse hight spectrum and the relationship between the radioactivity and the total counts are analyzed. It has been found from this study that the tapered scintillating optical fiber, if manufactured, can be practically applied to the development of gamma-ray sensors which can be deployed In ${\mu}Ci$-level radiation fields

  • PDF

Analyses of Transpiration and Growth of Paprika (Capsicum annuum L.) as Affected by Moisture Content of Growing Medium in Rockwool Culture

  • Tai, Nguyen Huy;Park, Jong Seok;Shin, Jong Hwa;Ahn, Tae In;Son, Jung Eek
    • Horticultural Science & Technology
    • /
    • v.32 no.3
    • /
    • pp.340-345
    • /
    • 2014
  • Since the moisture content (MC) of growing medium closely related with the crop transpiration, the MC should be included to the environmental factors to be considered for irrigation control in soilless culture. The objective of this study was to analyze the transpiration of paprika plants using daily mean solar radiation (RAD) and vapor pressure deficit (VPD) as well as the growth of the plants at different MCs of rockwool growing media. The starting points of irrigation were controlled by a moisture sensor with minimum set points of 40%, 50%, and 60% of MCs. The canopy transpirations were measured for 80 to 120 days after transplanting and analyzed. The transpirations were well regressed with a combination of both RAD and VPD rather than daily mean RAD only under the controlled MCs. The transpiration at 60% MC was higher than those at 50% and 40% MCs. Leaf area, leaf fresh and dry weights at 60% MC were higher than those at 50% and 40% MCs while the number of leaves had no significant difference among the MCs. There were no significant differences in number of fruits and fruit size among all the MCs, while fruit weight was significantly lower at 40% MC than other treatments. Fresh and dry fruit yields were the highest at 60% MC. Therefore it was concluded that the transpiration was affected by the MC of rockwool growing medium and the minimum set point of 50-60% MC of rockwool growing medium gave better effects on the growth of the paprika plants.

Development of High-Sensitivity Detection Sensor and Module for Spatial Distribution Measurement of Multi Gamma Sources (감마선원의 공간분포 가시화 및 3D모델링을 위한 운용환경 개발)

  • Song, Keun-Young;Lim, Ji-Seok;Choi, Jung-Huk;Yuk, Young-Ho;Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.702-704
    • /
    • 2017
  • In case of dismantling of nuclear power generation facility or radiation accident, the accurate information of gammaray source is essential for rapid decontamination. In order to more efficiently represent the position of the gamma ray to be removed, we create a spatial domain based on the real image. And we can perform decontamination of gamma-ray source more quickly by expressing the distribution of radiation source. The developed gamma ray imaging device overlaps with the visible image after gamma - ray detection and provides only two - dimensional image, but it does not show the distance information to the source. In this paper, we have developed a operation environment using the 3D visualization model for reporting effective decontamination operation.

  • PDF

SENSITIVITY ANALYSIS TO EVALUATE THE TRANSPORT PROPERTIES OF CdZnTe DETECTORS USING ALPHA PARTICLES AND LOW-ENERGY GAMMA-RAYS

  • Kim, Kyung-O;Ahn, Woo-Sang;Kwon, Tae-Je;Kim, Soon-Young;Kim, Jong-Kyung;Ha, Jang-Ho
    • Nuclear Engineering and Technology
    • /
    • v.43 no.6
    • /
    • pp.567-572
    • /
    • 2011
  • A sensitivity analysis of the methods used to evaluate the transport properties of a CdZnTe detector was performed using two different radiations (${\alpha}$ particle and gamma-ray) emitted from an $^{241}Am$ source. The mobility-lifetime products of the electron-hole pair in a planar CZT detector ($5{\times}5{\times}2\;mm^3$) were determined by fitting the peak position as a function of biased voltage data to the Hecht equation. To verify the accuracy of these products derived from ${\alpha}$ particles and low-energy gamma-rays, an energy spectrum considering the transport property of the CZT detector was simulated through a combination of the deposited energy and the charge collection efficiency at a specific position. It was found that the shaping time of the amplifier module significantly affects the determination of the (${\mu}{\tau}$) products; the ${\alpha}$ particle method was stabilized with an increase in the shaping time and was less sensitive to this change compared to when the gamma-ray method was used. In the case of the simulated energy spectrum with transport properties evaluated by the ${\alpha}$ particle method, the peak position and tail were slightly different from the measured result, whereas the energy spectrum derived from the low-energy gamma-ray was in good agreement with the experimental results. From these results, it was confirmed that low-energy gamma-rays are more useful when seeking to obtain the transport properties of carriers than ${\alpha}$ particles because the methods that use gamma-rays are less influenced by the surface condition of the CZT detector. Furthermore, the analysis system employed in this study, which was configured by a combination of Monte Carlo simulation and the Hecht model, is expected to be highly applicable to the study of the characteristics of CZT detectors.

The development of th gamma-ray imaging and operation algorithm for the gamma-ray detection system (감마선 탐지장치의 감마선 영상화 및 운용 알고리즘 개발)

  • Song, Kun-young;Hwang, Young-gwan;Lee, Nam-ho;Yuk, Young-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.942-943
    • /
    • 2016
  • Stereo gamma ray detection system generates a two-dimensional image of the gamma ray by using the position values and the gamma ray signal. And the device will overlap with the visible light image shows the actual distribution of the gamma-ray space. The gamma ray detection device is a stereo configuration to a motion controller for controlling the signal measurement unit and the position detection portion for detecting the detection portion and the gamma-ray signal comprising a gamma-ray detection sensor. In this paper, we developed a system operation management algorithm for each module individually configured efficiently. We confirmed the imaged and distribution information output for the gamma rays from gamma-ray irradiation test site by using these results.

  • PDF

Design of accelerated life test on temperature stress of piezoelectric sensor for monitoring high-level nuclear waste repository (고준위방사성폐기물 처분장 모니터링용 피에조센서의 온도 스트레스에 관한 가속수명시험 설계)

  • Hwang, Hyun-Joong;Park, Changhee;Hong, Chang-Ho;Kim, Jin-Seop;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.451-464
    • /
    • 2022
  • The high-level nuclear waste repository is a deep geological disposal system exposed to complex environmental conditions such as high temperature, radiation, and ground-water due to handling spent nuclear fuel. Continuous exposure can lead to cracking and deterioration of the structure over time. On the other hand, the high-level nuclear waste repository requires an ultra-long life expectancy. Thus long-term structural health monitoring is essential. Various sensors such as an accelerometer, earth pressure gauge, and displacement meter can be used to monitor the health of a structure, and a piezoelectric sensor is generally used. Therefore, it is necessary to develop a highly durable sensor based on the durability assessment of the piezoelectric sensor. This study designed an accelerated life test for durability assessment and life prediction of the piezoelectric sensor. Based on the literature review, the number of accelerated stress levels for a single stress factor, and the number of samples for each level were selected. The failure mode and mechanism of the piezoelectric sensor that can occur in the environmental conditions of the high-level waste repository were analyzed. In addition, two methods were proposed to investigate the maximum harsh condition for the temperature stress factor. The reliable operating limit of the piezoelectric sensor was derived, and a reasonable accelerated stress level was set for the accelerated life test. The suggested methods contain economical and practical ideas and can be widely used in designing accelerated life tests of piezoelectric sensors.

Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

  • Yusof, Mohd Yusmiaidil Putera Mohd;Rahman, Nur Liyana Abdul;Asri, Amiza Aqiela Ahmad;Othman, Noor Ilyani;Mokhtar, Ilham Wan
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.233-239
    • /
    • 2017
  • Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor(CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and inter-observer agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients