• 제목/요약/키워드: Radiation safety control

검색결과 230건 처리시간 0.028초

방사성 물질 등의 이용 증가에 따른 안전 관리 문제점 고찰 (The Increased Use of Radiation Requires Enhanced Activities Regarding Radiation Safety Control)

  • 이윤종;이진우;정교성
    • 방사선산업학회지
    • /
    • 제9권2호
    • /
    • pp.103-109
    • /
    • 2015
  • More recently, companies that have obtained permission to use radioactive materials or radiation device and registered radiation workers have increased by 10% and 4% respectively. The increased use of radiation could have an effect on radiation safety control. However, there is not nearly enough manpower and budget compared to the number of workers and facilities. This paper will suggest a counteroffer thought analyzing pending issues. The results of this paper indicate that there are 47 and 31.3 workers per radiation protection officer in educational and research institutes, respectively. There are 20.1 persons per RPO in hospitals, even though there are 2 RPOs appointed. Those with a special license as a radioisotope handler were ruled out as possible managers because medical doctors who have a special license for radioisotope handling normally have no experience with radiation safety. The number of staff members and budget have been insufficient for safety control at most educational and research institutes. It is necessary to build an optimized safety control system for effective Radiation Safety Control. This will reduce the risk factor of safety, and a few RPOs can be supplied for efficiency and convenience.

진단용 방사선안전관리 현황에 관한 연구 (A Study on Enforcement Effects of Radiation Safety Control Regulations for Diagnostic X-ray Equipments)

  • 성모일;박명환;권덕문;이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권1호
    • /
    • pp.73-78
    • /
    • 1999
  • The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipments and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of the respondents realized the importance of the radiation safety control system, but about a half of them revealed that the regulations were not well observed in accordance with their purposes. Only 43.9% of the respondents took an active part in quality control and safety control of radiation. And respondents responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Trainings for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipments. And management of organizations using diagnostic X-ray equipments have to understand and stress the importance of radiation safety control system.

  • PDF

Neutronics analysis of JSI TRIGA Mark II reactor benchmark experiments with SuperMC3.3

  • Tan, Wanbin;Long, Pengcheng;Sun, Guangyao;Zou, Jun;Hao, Lijuan
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1715-1720
    • /
    • 2019
  • Jozef Stefan Institute (JSI), TRIGA Mark II reactor employs the homogeneous mixture of uranium and zirconium hydride fuel type. Since its upgrade, a series of fresh fuel steady state experimental benchmarks have been conducted. The benchmark results have provided data for testing computational neutronics codes which are important for reactor design and safety analysis. In this work, we investigated the JSI TRIGA Mark II reactor neutronics characteristics: the effective multiplication factor and two safety parameters, namely the control rod worth and the fuel temperature reactivity coefficient using SuperMC. The modeling and real-time cross section generation methods of SuperMC were evaluated in the investigation. The calculation analysis indicated the following: the effective multiplication factor was influenced by the different cross section data libraries; the control rod worth evaluation was better with Monte Carlo codes; the experimental fuel temperature reactivity coefficient was smaller than calculated results due to change in water temperature. All the results were in good agreement with the experimental values. Hence, SuperMC could be used for the designing and benchmarking of other TRIGA Mark II reactors.

INFORMATION SYSTEM ON INTEGRATED RADIATION SAFETY (ISIRS) AND ORPHAN SOURCES CONTROL IN KOREA

  • Lee, Dewhey
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.255-263
    • /
    • 2001
  • An Orphan Sources Control program controlled by a web based information system in Korea has been developed to satisfy the national demand on a total management of and integrated radiation safety. There are, currently, three approaches going on to control and manage the orphan sources in Korea. First, Korean regulatory authority has been conducting scrutinizing investigation on and thoroughly monitoring the possession of unlicensed radioactive sources from the late 1990s. Second, the regulatory authority will fully operate an information system on radiation safety to effectively trace and monitor all radioactive sources in the country by the mid 2001. Finally, the regulatory authority strongly advises steel mill companies to closely scrutinize and inspect the scrap metals when they attempt to reutilize metals to prevent from being contaminated by uncontrolled sources through the scrap monitoring systems.

  • PDF

중환자실 간호사를 대상으로 소책자를 활용한 방사선 안전관리 교육의 효과 (Effects of Radiation Safety Management Education with the Use of a Booklet for Intensive Care Unit Nurses)

  • 이정은;김상희
    • 중환자간호학회지
    • /
    • 제10권2호
    • /
    • pp.1-13
    • /
    • 2017
  • Purpose: This study investigated the effects that the use of a booklet for intensive care unit nurses had on radiation safety management education (knowledge about and behaviors in radiation safety management, and awareness of anxiety caused by radiation hazards). Methods: A randomized control group pretest-posttest design was used. A booklet about radiation safety management developed by the authors was used as educational material. Participants (N=42) were intensive care unit nurses of P hospital in B city. Training was provided to the experimental group (N=21). Knowledge about and behaviors in radiation safety management and awareness of anxiety caused by radiation hazards were measured by questionnaires before and after the intervention. Data was analyzed by an $X^2$-test, non-paired t-test, and paired t-test. Results: There was a significant difference between groups in knowledge of (t=-14.932, p<.001) and behaviors in (t=-8.297, p<.001) radiation safety management and awareness of anxiety caused by radiation hazards (t=9.378, p<.001). Conclusion: The levels of knowledge about and behaviors in radiation safety management and awareness of anxiety generated by radiation hazards of intensive care unit nurses increased after receiving one session of radiation safety management education using the booklet. Therefore, providing radiation safety management training is suggested as an effective strategy for improving radiation safety management.

  • PDF

An adaptive deviation-resistant neutron spectrum unfolding method based on transfer learning

  • Cao, Chenglong;Gan, Quan;Song, Jing;Yang, Qi;Hu, Liqin;Wang, Fang;Zhou, Tao
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2452-2459
    • /
    • 2020
  • Neutron spectrum is essential to the safe operation of reactors. Traditional online neutron spectrum measurement methods still have room to improve accuracy for the application cases of wide energy range. From the application of artificial neural network (ANN) algorithm in spectrum unfolding, its accuracy is difficult to be improved for lacking of enough effective training data. In this paper, an adaptive deviation-resistant neutron spectrum unfolding method based on transfer learning was developed. The model of ANN was trained with thousands of neutron spectra generated with Monte Carlo transport calculation to construct a coarse-grained unfolded spectrum. In order to improve the accuracy of the unfolded spectrum, results of the previous ANN model combined with some specific eigenvalues of the current system were put into the dataset for training the deeper ANN model, and fine-grained unfolded spectrum could be achieved through the deeper ANN model. The method could realize accurate spectrum unfolding while maintaining universality, combined with detectors covering wide energy range, it could improve the accuracy of spectrum measurement methods for wide energy range. This method was verified with a fast neutron reactor BN-600. The mean square error (MSE), average relative deviation (ARD) and spectrum quality (Qs) were selected to evaluate the final results and they all demonstrated that the developed method was much more precise than traditional spectrum unfolding methods.

전리방사선 노출과 관리 (Exposure Assessment and Management of Ionizing Radiation)

  • 정은교;김갑배;송세욱
    • 한국산업보건학회지
    • /
    • 제25권1호
    • /
    • pp.27-35
    • /
    • 2015
  • Objectives: To investigate safety and health management, conditions in factories or facilities handling radiation-generating devices and radioactive isotopes were reviewed in terms of regulations of radiation safety control in Korea. Radiation exposure levels generated at those facilities were directly measured and evaluated for establishing an effective safety and health management plan. Methods: Government organizations with laws and systems of radiation safety and health were investigated and compared. There are three laws governing radiation-related employment such as occupational safety and health acts, nuclear safety acts, and medical service acts. We inspected 12 workplaces as research objects:four workplaces that manufacture and assemble semiconductor devices, three non-destructive inspection workplaces that perform inspections on radiation penetration, and five workplaces in textile and tire manufacturing. Monitoring of radiation exposure was performed through two methods. Spatial and surface monitoring using real-time radiation instruments was performed on each site handling radiation generating devices and radioactive isotopes in order to identify radiation leakage. Results: According to the occupational safety and health act, there is no legal obligation to measure ionizing radiation and set dose limits. This can cause confusion in the application of the laws, because the scopes and contents are different from each other. Surface dose rates in radiation generating devices such as implanters, thickness gages and accelerators, which were registered according to nuclear safety acts, using surveymeters, and seven of 36 facilities(19.4%) exceeded the international standards for surface radiation dose of $10{\mu}Sv/hr$. Conclusions: The results showed that occupational health and safety acts require a separate provision for measuring and assessing the radiation exposure of workers performing radiation work. Like noise, ionizing radiation will also periodically be controlled by including it in the object factors of work-environment measurement.

치과위생사의 방사선 안전관리 실태 및 피폭 불안감에 영향을 미치는 요인 (Factors affecting radiation safety management of dental hygienist and anxiety of radiation exposure)

  • 이혜경
    • 한국산학기술학회논문지
    • /
    • 제19권6호
    • /
    • pp.432-439
    • /
    • 2018
  • 본 연구는 치과위생사를 대상으로 방사선 관리에 대한 지식, 태도, 안전관리 행위, 방사선 피폭 불안감을 분석하고 이에 영향을 미치는 요인들을 분석함으로써 방사선 안전 관리 수준을 향상하고 방사선 취급에 대한 올바른 인식 전환과 불안감을 줄이는 방안을 도출하고자 연구하였다. 연구기간은 2017년 9월 10일부터 10월 31일까지 전라북도에 근무하는 치과위생사 280명을 대상으로 SPSS 12.0 프로그램을 사용하여 빈도, 기술통계, 다중회귀분석을 실시하여 분석하여 다음과 같은 결과를 얻었다. 방사선 질 관리에 대한 지식 정도의 평균은 8.07 였고, 정답률은 75.3% 였다. 태도 정도는 96.1%가 긍정적인 태도를 보였으며, 방사선 안전관리 행위는 촬영자는 4.11 였고, '방사선 촬영 시 항상 TLD(개인선량계)를 착용한다'는 4.58 로 가장 높았다. 환자 방사선 안전관리 행위는 3.86 였고, '방사선촬영 전 가임기 여성의 임신 여부를 확인한다'는 4.69 로 가장 높았다. 방사선 피복 뷸안감은 3.86 였고, '임신 중 일 때 태아의 건강 문제로 염려된다'는 4.13로 가장 높았다. 방사선 피폭 불안감에 영향을 미치는 요인으로는 방사선 안전관리 행위가 낮을수록, 연령이 낮을수록, 방사선 촬영경력이 낮을수록, 최종학력이 높을수록, 월 소득이 많을수록, 직위가 높을수록 유의한 영향을 미치는 것으로 나타났다(p<0.05). 이상의 연구결과를 토대로 치과위생사는 방사선 질 관리에 대한 지식, 태도, 안전관리 행위는 높았으나, 방사선 피폭 불안감은 높은 불안감을 가지고 있어 방사선 안전 관리 수준을 향상시켜 방사선 피폭 불안감을 줄일 수 있는 방안 마련이 이루어져야 할 것으로 사료된다.

방사선 영상 매핑 장치 (Radiation image mapping system)

  • 최영수;박순용;이종민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1884-1887
    • /
    • 1997
  • The increasing concern over radiation exposure in the nuclear industry has fostered agrressive efforts to reduce the levels of radiation exposure. One area of the effot to reduce the radiation exposure is the development of a remote radiation monitoring system. Remote radiation monitoring can serve many benificaial functions reduce exposure to radiation by plant personnel, impruve the quality of the data that is collected and recognize the radiation environment easily. Radiation mapping system gives a good information that represents radiation level distribution. The system we have developed consists of a data acquistion parts, mobile robot and remote control parts. Data acquisition parts consist of radiation detection module and vision acquistion module which collect radiation data, visiion data and distance information. In remote control parts, the acquision data are processed and displayed. We have constructed radiation mapping image by overlaying the vision and radiation data. The radiation mapping techniques for displaying the results of the survey in an easily comprehendable form will facilitate a better understanding of the radiation environment in the facility. This system can reduce workers radiation exposure and aid to help work plan, so it has significant benifits in cost and safety.

  • PDF

원자력안전법에 대한 방사선학과 학생들의 학습권 보장에 관한 연구 (A Study on the Guarantee of Learning Rights of Radiology Students in Nuclear Safety Act)

  • 이보우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.159-164
    • /
    • 2022
  • The study developed a radiation dose measurement program in the radiology laboratory to measure how much exposure the students are exposed to during the radiology class, to request for the improvement and the revision of the current Nuclear Safety Act. The experimental program is shown in the following figure, and experiments were conducted to determine the degree of radiation exposure in the control room with a lead gown at a distance of 1 m, 2 m, and 1 m, and in a control room with a radiographic lead glass wall. The duration of the experiment was 3 months from April to June, when radiation imaging practice classes were conducted, and 128 hours of imaging practice per month were conducted. In order to find out the dose of radiation dose during radiology imaging practice class, the experiment was carried out from April to June for 3 months, and according to the program, the results of exposure dose were 0.34 mSv at 1 m distance, 0.01 mSv at shielding of lead gown at 1 m distance, 0.16 mSv at 2 m distance, and 0.01 mSv at control room with radiation lead glass wall. The exposure dose from the test results was much below the annual general public limit dose of 1 mSv. The restriction on the operation of the radiation equipment in the practice of the students is a regulation that infringes the right of students to learn, and amendments or exemptions of Nuclear Safety Act should be enacted to ensure that it does not violate the fundamental right to learn for students in radiology.