Evaluation of Clinical Availability for Shoulder Forced Traction Method to Minimize the Beam Hardening Artifact in Cervical-spine Computed Tomography (CT) (경추부 전산화단층촬영에서 선속 경화 인공물을 최소화하기 위한 견부 강제 견인법에 대한 임상적 유용성 평가)

  • Kim, Moonjeung;Cho, Wonjin;Kang, Suyeon;Lee, Wonseok;Park, Jinwoo;Yu, Yunsik;Im, Inchul;Lee, Jaeseung;Kim, Hyeonjin;Kwak, Byungjoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • In study suggested clinical availability to shoulder forced traction method in term of quality of image, the patient's convenience and stability, according to whether to use of shoulder forced traction bend using computed tomography(CT) that X-ray calibration and various mathematic calibration algorithm application can be applied by AEC. To achieve this, 79 patients is complaining of cervical pain oriented that shoulder forced traction bend use the before and after acquires lateral projection scout image and transverse image. transverse image of a fixed size in concern field of pixel and figure the average HU value compare that quantitative analysis. Artifact and pixel and resolution to qualitative clinical estimation image analysis. the patient feel inconvenience degree that self-diagnosis survey that estimate. As a result, lateral projection scout image if you used shoulder forced traction bend for the depicted has been an increase in the number of a cervical vertebrae. transverse image concern field shoulder forced traction bend use the before and after for pixel and the average HU-value changes was judged to be almost irrelevant. Artifact and resolution and contrast, in qualitative analysis of the results relating the observer to the unusual result. So, the patients of 82.27% complained discomfort that use of shoulder forced traction bend in self-diagnosis survey. No merit of medical image by using of bend from result was analyzed quality of image to quantitative and qualitative method judged. Nowadays, CT is supplied possible revision of quality of radiation by reduction of slice and automatic exposure controller, etc and application of preconditioning filter process due to various mathematic revision algorithm. So, image noise by beam hardening artifact should not be a problem. shoulder forced traction bend of use no longer judged clinically availability because have not influence of image quality and give discomfort, have extra dangerousness.

The Crystal and Molecular Structure of Sodium Sulfisoxazole hexahydrate (Sodium Sulfisoxazole Hexahydrate의 결정 및 분자구조와 수소결합에 관한 연구)

  • Young Ja Park;Chung Hoe Koo
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.1
    • /
    • pp.19-34
    • /
    • 1976
  • The crystal structure of sodium sulfisoxazole hexahydrate, $C_{11}H_{12}N_3O_3SNa{\cdot}6H_2O$,has been determined by X-ray diffraction method. The compound crystallizes in the monoclinic space group $$P2_1}c$$ with a = 15.68(3), b = 7.70(2), c = 17.94(4)${\AA}$, ${\beta}$ = $118(2)^{\circ}$ and Z = 4. A total of 1717 observed reflections were collected by the Weissenberg method with $CuK{\alpha}$ radiation. Structure was solved by heavy atom method and refined by block-diagonal least-squares methods to the R value of 0.14. The conformational angle formed by the S-C(l) bond with that of N(2)-C(7), when the projection in taken along the S-N(2), is $73^{\circ}.$ The benzene ring is planar and makes an angle of $60^{\circ}$ with the plane of the isoxazole ring, which is also planar. The sodium atom has a distorted octahedral coordination of N(l) and five oxygen atoms from hydrate molecules. Sodium sulfisoxazole hexahydrate shows fourteen different hydrogen bondings in the crystal. These are six $O-H{\cdots}O-H bonds, three $O-H{\cdots}O$ bonds, two $O-N{\cdots}N,$ one $N-H{\cdots}O,O-H{\cdots}N,N-H{\cdots}O-H$ bond, with the distances in the range of 2.71 to $3.04{\AA}.$.

  • PDF

Projection of Future Snowfall by Using Climate Change Scenarios (기후변화 시나리오를 이용한 미래의 강설량 예측)

  • Joh, Hyung-Kyung;Kim, Saet-Byul;Cheong, Hyuk;Shin, Hyung-Jin;Kim, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.3
    • /
    • pp.188-202
    • /
    • 2011
  • Due to emissions of greenhouse gases caused by increased use of fossil fuels, the climate change has been detected and this phenomenon would affect even larger changes in temperature and precipitation of South Korea. Especially, the increase of temperature by climate change can affect the amount and pattern of snowfall. Accordingly, we tried to predict future snowfall and the snowfall pattern changes by using the downscaled GCM (general circulation model) scenarios. Causes of snow varies greatly, but the information provided by GCM are maximum / minimum temperature, rainfall, solar radiation. In this study, the possibility of snow was focused on correlation between minimum temperatures and future precipitation. First, we collected the newest fresh snow depth offered by KMA (Korea meteorological administration), then we estimate the temperature of snow falling conditions. These estimated temperature conditions were distributed spatially and regionally by IDW (Inverse Distance Weight) interpolation. Finally, the distributed temperature conditions (or boundaries) were applied to GCM, and the future snowfall was predicted. The results showed a wide range of variation for each scenario. Our models predict that snowfall will decrease in the study region. This may be caused by global warming. Temperature rise caused by global warming highlights the effectiveness of these mechanisms that concerned with the temporal and spatial changes in snow, and would affect the spring water resources.

Breast Cancer Trend in Iran from 2000 to 2009 and Prediction till 2020 using a Trend Analysis Method

  • Zahmatkesh, Bibihajar;Keramat, Afsaneh;Alavi, Nasrinossadat;Khosravi, Ahmad;Kousha, Ahmad;Motlagh, Ali Ghanbari;Darman, Mahboobeh;Partovipour, Elham;Chaman, Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1493-1498
    • /
    • 2016
  • Background: Breast cancer is the most common cancer in women worldwide with a rising incidence rate in most countries. Considering the increase in life expectancy and change in lifestyle of Iranian women, this study investigated the age-adjusted trend of breast cancer incidence during 2000-2009 and predicted its incidence to 2020. Materials and Methods: The 1997 and 2006 census results were used for the projection of female population by age through the cohort-component method over the studied years. Data from the Iranian cancer registration system were used to calculate the annual incidence rate of breast cancer. The age-adjusted incidence rate was then calculated using the WHO standard population distribution. The five-year-age-specific incidence rates were also obtained for each year and future incidence was determined using the trend analysis method. Annual percentage change (APC) was calculated through the joinpoint regression method. Results: The bias adjusted incidence rate of breast cancer increased from 16.7 per 100,000 women in 2000 to 33.6 per 100,000 women in 2009. The incidence of breast cancer had a growing trend in almost all age groups above 30 years over the studied years. In this period, the age groups of 45-65 years had the highest incidence. Investigation into the joinpoint curve showed that the curve had a steep slope with an APC of 23.4% before the first joinpoint, but became milder after this. From 2005 to 2009, the APC was calculated as 2.7%, through which the incidence of breast cancer in 2020 was predicted as 63.0 per 100,000 women. Conclusions: The age-adjusted incidence rate of breast cancer continues to increas in Iranian women. It is predicted that this trend will continue until 2020. Therefore, it seems necessary to prioritize the prevention, control and care for breast cancer in Iran.

Analysis of the cause by Pre Exposure Tube Voltage and Actual Exposure Tube Voltage deviation in Mammography Examination (유방 촬영검사에서 사전조사 관전압과 실제조사 관전압 편차에 따른 원인 분석)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this study is to investigate the cause analysis according to the difference between the pre exposure tube voltage and actual exposure tube voltage in mammography in connection with breast pressure thickness, breast size and body mass index and to find the improvement. The study tracked 377 women age 40 and older among the mammography examiners conducted by the National Health Insurance Corporation. It was analyzed that breast pressure thickness, breast size and body mass index according to the difference between the pre exposure tube voltage and actual exposure tube voltage among the parameters of dose report been sent to the picture archiving communication system with reference to the image with cranio-caudal projection in mammography. As are result, it shows that the thicker the breast thickness, smaller the breast size and lower body mass index, the higher the difference of tube voltage. In conclusion, the minimum tube voltage of mammography machine should be reset in order to set the tube voltage according to breast pressure thickness and breast size that are suitable for our country in mammography, in addition, it was considered that radiologist should make an effort to reduce radiation exposure and make a good quality image with reducing the difference of mammography condition by making a correct exposure condition in case of examining the patients with thin breast pressure and small breast size.

Image Evaluation of Projection Method in Chest Radiography (흉부 엑스선 촬영 시 촬영기법에 따른 영상 평가)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.217-223
    • /
    • 2022
  • In this study, images taken using a grid and images taken using Air Gap Technique were evaluated in X-ray chest radiography. Subjective Evaluation The ROC (Receiver Operating Characteristic) evaluation was evaluated by 5 radiologists who had worked for more than 10 years in the radiology department of a university hospital. Objective evaluation SNR (Signal to noise ratio) was evaluated. As a result of the analysis, the Cronbach Alpha value was 0.714, which was significantly higher. In the Air Gap Technique, the distance between the phantom and the subject was set at 20 cm, and the image was taken with a tube voltage of 100 kVp, a tube current and a recording time of 8 mAs. In the ROC (Receiver Operating Characteristic) evaluation, the highest score was obtained with 18 score and an objective evaluation SNR (signal to noise ratio) of 6,149 scored. Also, in the imaging method using a grid, when the distance between the phantom and the constant receptor is 15 cm apart, and the tube voltage is 110 kVp, the tube current and the recording time are taken at 8 mAs, the ROC evaluation score is 19 and the objective evaluation SNR (Signal to noise ratio) is the highest with 6.622 scored. Therefore, if the Air Gap Technique imaging method is used, which overcomes the shortcomings such as delay in reading, increase in patient's exposure dose, and shortening of mechanical lifespan, as well as re-radiography due to the cut-off phenomenon of the grid that appears using the grid, the It is thought that it will be very helpful for chest imaging, including the case of using a portable X-ray imaging device.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

A Survey on Radiation Exposure of Patient in Mammography (유방 X선촬영 시 피폭선량에 대한 조사 연구)

  • Kim, Hyung-Chul;Cho, Pyung-Gon;Kim, Sung-Soo;Choi, Jong-Hak;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.55-60
    • /
    • 2004
  • The purpose of this study was to examine both patient exposure dose during mammography and the utility status of mammograpy equipments. The data of this study were collected through questionnaire survey for 278 medical facilities registered at Korean Hospital Association and finally 161 medical facilities's data were analyzed. According to data analysis, medical facilities of 14.9% used the average glandular dose of less than 0.5 mGy, $0.51{\sim}1.0\;mGy$ 8.6%, $1.01{\sim}1.5\;mGy$ 14.9%, $1.51{\sim}2.0\;mGy$ 11.1%, $2.01{\sim}2.5\;mGy$ 9.8%, $2.51{\sim}3.0\;mGy$ 33.3%, and 7.4% more than 3.01 mGy. It was found that medical facilities of 92.6% used less than 3 mGy, showing that this figure is similar to the limit value of 3 mGy recommended by Korea Food & Drug Administration(KFDA). Recently, international organizations such as ICRP associated with radiation protection suggests that less than 3 mGy of average mammary gland dose be used during mammography in case of using Mo target+Mo filter, film/screen system and craniocaudal projection with the breast pressed to 4.2 cm. The standard dose is being strictly observed and that of the limits is going down to 2 mGy or 1.5 mGy. The major results of this study indicate that interests and a counterplan to reduce patient dose during mammography should be considered. Based on this study, the authors of this study will continue to measure exposure dose to set a new standard for patient exposure dose during mammography.

  • PDF

A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination (경추 정면 검사에서 방사선 입사각에 관한 연구)

  • Jeung, Seung-Woon;Lim, Cheong-Hwan;Han, Beom-Hee;Jung, Hong-Ryang;Joo, Yeong-Cheol;Park, Mi-Ja
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.83-92
    • /
    • 2012
  • In anteroposterior projection for cervical vertebra, it is general that the incidence angle of X-ray is $15^{\circ}$ to $20^{\circ}$ degrees to head in order to prevent overlap of mandible and occipital bone and to observe array of cervical interbody and shapes of joints. However, the angle is appropriate for foreigners that was determined by foreign literature review long ago, and there have been few researches of incidence angle for Koreans' body type. The purpose of in this study are to identify the incidence angle appropriate for Koreans and to present methodology. In order to measure the incidence angle, 1,044 patients who visited S Hospital located in Seosan were selected and measured of average length of cervical vertebra, OID, axis angle, and FID. The incidence angle was calculated from the applied formula by measuring average values per age groups and sex (see Formula 1 and 2). The average length of cervical vertebra was 6cm: the length was increased from teenagers to twenties but was decreased since thirties. The difference between males and females was around 1cm (p<.01). The OID was almost the same regardless of age groups and sex. As for axis angle, the slope was increased in teenagers and twenties, but was decreased since thirties. The difference between males and females was around 2 degrees (p<.01). The FID measurements were almost the same regardless of age groups and sex, and when the incidence angle was measured from these values, the teenagers were $15.9^{\circ}$, the twenties were $16.9^{\circ}$, the thirties were $16.6^{\circ}$, the forties were $16.2^{\circ}$, the fifties were $15.9^{\circ}$, and the sixties were $14.5^{\circ}$, indicating that the angle was increased from teenagers to the twenties but decreased since the thirties. While the angles of males and females were measured to be the same in the teenagers, the angle was different between males and females by $2^{\circ}$. When the incidence angle statistically analyzed with measurement of average length of cervical vertebra, OID, axis angle, and FID, all of them were shown to have correlations with the incidence angle (p<.01). Conclusively, it was shown that the incidence angle was measured differently from average length of cervical vertebra, OID, FID, and axis slope, as well as from age and sex. Therefore, it can be suggested that the anteroposterior radiation test for cervical vertebra should be conducted by different incidence angles based on age and sex. The data of this study may be used as reference in determining the incidence angle of cervical vertebra tests for the future.

Oxide perovskite crystals type ABCO4:application and growth

  • Pajaczkowska, A.
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.258-292
    • /
    • 1996
  • In the last year great interest appears to YBCO thin films preparation on different substrate materials. Preparation of epitaxial film is a very difficult problem. There are many requirements to substrate materials that must be fullfilled. Main problems are lattice mismatch (misfit) and similarity of structure. From paper [1] or follows that difference in interatomic distances and angles of substrate and film is mire important problem than similarity of structure. In this work we present interatomic distances and angle relations between substrate materials belonging to ABCO4 group (where A-Sr or Ca, B-rare earth element, C-Al or Ga) of different orientations and YBCO thin films. There are many materials used as substrates for HTsC thin films. ABCO4 group of compounds is characterized by small dielectric constants (it is necessary for microwave applications of HTsC films), absence of twins and small misfit [2]. There most interesting compounds CaNdAlO4, SrLaAlO4 and SrLaGaO4 were investigated. All these compounds are of pseudo-perovskite structure with space group 14/mmm. This structure is very similar to structure of YBCO. SLG substrate has the lowest misfit (0.3%) and dielectric constant. For preparation of then films of substrates of this group of compound plane of <100> orientation are mainly used. Good quality films of <001> orientations are obtained [3]. In this case not only a-a misfit play role, but c-3b misfit is very important too. Sometimes, for preparation of thin films substrates of <001> and <110> orientations were manufactured [3]. Different misfits for different YBCO faces have been analyzed. It has been found that the mismatching factor for (100) face is very similar to that for (001) face so there is possibility of preparation of thin films on both orientations. SrLaAlO4(SLA) and SrLaGaO4(SLG) crystals of general formula ABCO4 have been grown by the Czochralski method. The quality of SLA and SLG crystals strongly depends on axial gradient of temperature and growth and rotation rates. High quality crystals were obtained at axial gradient of temperature near crystal-melt interface lower than 50℃/cm, growth rate 1-3 mm/h and the rotation rate changing from 10-20pm[4]. Strong anisotropy in morphology of SLA and SLG single crystals grown by the Czochralski method is clearly visible. On the basics of our considerations for ABCO4 type of the tetragonal crystals there can appear {001}, {101}, and {110} faces for ionic type model [5]. Morphology of these crystals depend on ionic-covalent character of bonding and crystal growth parameters. Point defects are observed in crystals and they are reflected in color changes (colorless, yellow, green). Point defects are detected in directions perpendicular to oxide planes and are connected with instability of oxygen position in lattice. To investigate facets formations crystals were doped with Cr3+, Er3+, Pr3+, Ba2+. Chromium greater size ion which is substituted for Al3+ clearly induces faceting. There appear easy {110} faces and SLA crystals crack even then the amount of Cr is below 0.3at.% SLG single crystals are not so sensitive to the content of chromium ions. It was also found that if {110} face appears at the beginning of growth process the crystal changes its color on the plane {110} but it happens only on the shoulder part. The projection of {110} face has a great amount of oxygen positions which can be easy defected. Pure and doped SLA and SLG crystals measured by EPR in the<110> direction show more intensive lines than in other directions which allows to suggest that the amount of oxygen defects on the {110} plane is higher. In order to find the origin of colors and their relation with the crystal stability, a set of SLA and SLG crystals were investigated using optical spectroscopy. The colored samples exhibit an absorption band stretching from the UV absorption edge of the crystal, from about 240 nm to about 550 m. In the case of colorless sample, the absorption spectrum consists of a relatively weak band in the UV region. The spectral position and intensities of absorption bands of SLA are typical for imperfection similar to color centers which may be created in most of oxide crystals by UV and X-radiation. It is pointed out that crystal growth process of polycomponent oxide crystals by Czochralski method depends on the preparation of melt and its stoichiometry, orientation of seed, gradient of temperature at crystal-melt interface, parameters of growth (rotation and pulling rate) and control of red-ox atmosphere during seeding and growth (rotation and pulling rate) and control of red-ox atmosphere during seeding and growth. Growth parameters have an influence on the morphology of crystal-melt interface, type and concentration of defects.