• 제목/요약/키워드: Radiation pressure

검색결과 681건 처리시간 0.028초

복사-대류 겸용 하이브리드 냉방기 (Hybrid Air-Conditioner Using Both Radiation and Convection)

  • 변호원;오왕규;김내현;최병남;이상엽;한성필
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.330-333
    • /
    • 2008
  • The hybrid air-conditioner, where air is cooled both by convection and radiation, is developed. The indoor unit of the air-conditioner consists of radiation panel and dehumidification coil, where refrigeration R-134a is supplied by independent refrigeration cycles. Optimum refrigerant charge was 750g for both cycles. Optimum evaporation pressure was 3.7 bar for the radiation panel cycle and 3.9 bar for the dehumidification cycle. The cooling capacity of the radiation panel was 1.01 kW and that of the dehumidification coil was 0.94kW, which yielded COP of 3.3.

  • PDF

일부 남성근로자의 3년간 고혈압 발생률과 위험요인 (The Incidence and Risk Factors of Hypertension that Developed in a Male-workers' Cohort for 3 Years)

  • 서현주;김종순;장윤균;박일근;김수근
    • Journal of Preventive Medicine and Public Health
    • /
    • 제39권3호
    • /
    • pp.229-234
    • /
    • 2006
  • Objectives: Cardiovascular disease is one of the main causes of death and morbidity in Korea. In this study, the prevalence and incidence of developing hypertension in a male-workers' cohort were investigated during 3-years follow-up with a view to find the risk factors that affected the development of hypertension. Methods: Among the 5,374 people who participated in a routine health check up, 3,852 people with normal blood pressure and who had no history of hypertension were prospectively followed up for 3 years. The classification of hypertension was based on the JNC7 report (the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure). Life style factors and underlying diseases that were related to the risk factors of hypertension were collected by using a self-report questionnaires via the internet. Results: The prevalence of hypertension was 28.3% (1,520/5,374) at the first screening (2001). It was found that the incidence in 2004 of hypertension for the follow-up subjects (3,711) who had normal blood pressure in 2001 was 7.6 per 100 person-year. Multiple logistic regression analysis of the variables related to the risk factors of hypertension was carried out. The relative risks were 1.037 (95% CI=1.022-1.053) as the age increased 1 year and 1.039 (95% CI=1.023-1.055) as the body mass index increased $1kg/m^2$. The relative risk for the prehypertensive group was 2.501 (95% CI=1.986-3.149) compared to the normotensive group. These results showed that age, body mass index and the baseline blood pressure were significantly related to the incidence of hypertension. Conclusions: The incidence of hypertension was 7.6 per 100 person-year during follow-up. It was concluded that the risk factors for developing hypertension in the short-term were age, BMI, and prehypertension; Especially, this showed that it is necessary for prehypertensives to manage their body weight and blood pressure to prevent hypertension in middle-age by modifying their life style.

Impact by Estimation Error of Hourly Horizontal Global Solar Radiation Models on Building Energy Performance Analysis on Building Energy Performance Analysis

  • Kim, Kee Han;Oh, John Kie-Whan
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.3-10
    • /
    • 2014
  • Impact by estimation error of hourly horizontal global solar radiation in a weather file on building energy performance was investigated in this study. There are a number of weather parameters in a given weather file, such as dry-bulb, wet-bulb, dew-point temperatures; wind speed and direction; station pressure; and solar radiation. Most of them except for solar radiation can be easily obtained from weather stations located on the sites worldwide. However, most weather stations, also including the ones in South Korea, do not measure solar radiation because the measuring equipment for solar radiation is expensive and difficult to maintain. For this reason, many researchers have studied solar radiation estimation models and suggested to apply them to predict solar radiation for different weather stations in South Korea, where the solar radiation is not measured. However, only a few studies have been conducted to identify the impact caused by estimation errors of various solar radiation models on building energy performance analysis. Therefore, four different weather files using different horizontal global solar radiation data, one using measured global solar radiation, and the other three using estimated global solar radiation models, which are Cloud-cover Radiation Model (CRM), Zhang and Huang Model (ZHM), and Meteorological Radiation Model (MRM) were packed into TRY formatted weather files in this study. These were then used for office building energy simulations to compare their energy consumptions, and the results showed that there were differences in the energy consumptions due to these four different solar radiation data. Additionally, it was found that using hourly solar radiation from the estimation models, which had a similar hourly tendency with the hourly measured solar radiation, was the most important key for precise building energy simulation analysis rather than using the solar models that had the best of the monthly or yearly statistical indices.

An Experimental Study on the Relationship Between Temperature and Pressure Inside the Cup During Cupping Procedures

  • Lee, Ha Lim;An, Soo Kwang;Lee, Jae Yong;Shim, Dong Wook;Lee, Byung Ryul;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • 제38권1호
    • /
    • pp.41-46
    • /
    • 2021
  • Background: Pressure changes related to temperature variation during cupping may lead to dropout. This study aimed to investigate pressure changes related to temperature variations in the cup during the cupping procedure. Methods: Changes in temperature and pressure were measured for 15 minutes after the procedure was performed using the alcohol rub method with glass cups and with the addition of infrared irradiation. Changes in temperature and pressure were also measured for 15 minutes after pumping 3 times using the valve suction method, and with the addition of infrared irradiation. Results: In a comparison between the alcohol rub method with glass cups and with the addition of infrared irradiation, the negative pressure increased over time in the absence of infrared irradiation, whereas it decreased when performed with infrared irradiation p = 0.094. However, in a comparison between pumping 3 times using the valve suction method, and with the addition of infrared irradiation, the negative pressure decreased in both cases, but this was more significant with infrared irradiation p = 0.172. There was a significantly higher temperature in the glass cups (p = 0.004) and the valve cups (p = 0.001) exposed to infrared radiation, compared with no infrared irradiation. Conclusion: The reduction in negative pressure inside the cups exposed to infrared radiation was greater than without infrared irradiation. Temperature increases inside the cup can lead to the risk of dropout.

서로 다른 매질을 갖는 격실사이의 음파전달해석 (An Analysis of the Sound Propagation between Rooms with Different Mediums)

  • 김현실;김재승;이성현;서윤호
    • 한국음향학회지
    • /
    • 제32권5호
    • /
    • pp.402-407
    • /
    • 2013
  • 본 논문은 인접한 두 격실의 매질이 다를 때 공통 벽을 통한 음파의 전파를 해석한 내용을 다루었다. 통계적 에너지해석법(statistical energy energy)을 사용하여 두 격실의 음향에너지와 벽의 진동에너지간의 에너지 평형을 고려하였으며 소음원실의 음압이 벽을 투과하는 성분 외에 벽의 구조소음으로 인한 음의 방사(radiation)가 수음원실의 음압에 미치는 영향을 검토하였다. 예제로 선박의 엔진실과 물탱크가 크기 $8.4{\times}4$ m인 강판을 사이에 두고 접한 경우를 해석하였다. 강판의 임계주파수(critical frequency)가 관심주파수대역보다 큰 경우 63 Hz이하의 저주파수대역을 제외하고 음파의 전달은 강판을 투과하는 성분에 의해 주로 결정되며 강판의 구조소음에 기인한 방사소음은 무시할 정도로 기여도가 작음을 확인하였다.

게이트 심근 SPECT를 이용한 비침습적 심실 수축력 측정방법의 재현성 (Reproducibility of non-invasive measurement for left ventricular contractility using gated myocardial SPECT)

  • 김경민;이동수;김유경;천기정;김석기;정준기;이명철
    • 대한핵의학회지
    • /
    • 제35권3호
    • /
    • pp.152-160
    • /
    • 2001
  • 목적: 게이트 심근 SPECT를 이용하여 좌심실심근의 최대탄성률을 측정하는 방법의 재현성을 조사하고 단일 압력-부피 고리방법과 매개변수 최적화 방법으로 얻었을 때 재현성의 차이를 조사하였다. 대상 및 방법: 관상동맥질환이 의심되는 47명 (남자 42명, 여자 5명, 평균나이 53세, 좌심실구혈률 22-68%)에서 Tc-99m MIBI게이트 심근 SPECT와 동시에 요골동맥 긴장도를 측정하였다. 이 중 11명에서는 누운 자리에서 움직이지 않고 연이어 두번 측정하였다. 최대탄성률과 영점부피를 Lee 등이 제안한 단일 압력-부피 고리 방법과 Yoshizawa 등이 제안한 선형근사에 의한 매개변수 최적화 방법으로 추정하였다. 결과: 최대탄성률(상관계수 0.96)과 영점부피(상관계수 0.99)의 재현성은 단일 압력-부피 고리 방법이 매개변수 최적화 방법(최대탄성률 0.89, 영점부피 0.64)보다 좋았다. 두 방법으로 추정한 최대탄성률의 상관계수는 0.77, 영점부피의 상관계수는 0.65이었다. 결론: 게이트 심근 SPECT와 동맥긴장도 측정법으로 얻어 단일 압력-부피 고리 방법으로 추정한 좌심실 심근의 최대탄성률의 재현성은 매우 우수하였다. 매개변수 최적화 방법으로 얻은 최대탄성률도 우수하나 단일 압력-부피 고리 방법보다 못하였다.

  • PDF

우수방사성의약품 생산시설 개발 (Development of Good Manufacturing facility for Radiopharmaceuticals)

  • 신병철;정원명;박상현;이규일;박경배;박진호
    • Journal of Pharmaceutical Investigation
    • /
    • 제33권2호
    • /
    • pp.145-149
    • /
    • 2003
  • Manufacturing facilities of the pharmaceuticals must meet certain level of the cleanness required so that foreign substances such as dust, moisture, heat, microorganism, or virus do not contaminate the product. In case of radiopharmaceuticals for medical treatment and diagnosis, not only should the operators and environment be protected from radiation but also need to be isolated from the foreign contaminant. Therefore, manufacturing facilities for radiopharmaceuticals must satisfy the design standards of both hot cell and clean room which are specified by GMP. However, standards of maintaining negative pressure for preventing spread of radioactive contaminant in isolated facilities conflict with the standards of maintaining positive pressure for keeping cleanness. To solve this problem, air pressure of hot cell was designed lower than in the adjacent area to meet standards of the radiation safety. To keep higher cleanness in certain part of the hot cell for filling, minimal relative positive pressure allows. In order to effectively maintain the cleanness that is required for production of Tc-99m generator, which takes 70% of whole demand of radiopharmaceuticals, the rooms placed in each side of production room are used as a buffer area and three lead hot cells are installed in production room. In this research, we established the appropriate engineered design concept for Tc-99m generator manufacturing facility, which satisfies both GMP cleanness standard for preventing particles, bacteria, other contaminants and the regulations of radiation safety for supervising and controlling the amount of radiation exposure and exhausted radioactivity. And the concept of multi-barrier buffer zones is introduced to apply negative air pressure for hot cell with first priority and to continue relative positive air pressure for clean room.

적외선 검출기용 극저온 챔버에서 복사 차폐막을 고려한 열해석 (Thermal Analysis of a Cryochamber for an Infrared Detector Considering a Radiation Shield)

  • 김영민;강병하
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.672-677
    • /
    • 2006
  • The steady cooling characteristics of a cryochamber for infrared (IR) detector have been investigated analytically, considering radiation shields. The thermal modeling considers the conduction heat transfer through cold finger, the gaseous conduction due to out-gassing, and the radiation heat transfer. The cooling load of the cryochamber is obtained by using a fin equation. The results obtained indicate that the gaseous conduction plays an important role in determining the steady cooling load. The steady cooling load is increased as the gas pressure is increased. It is also found that the cooling load is substantially decreased with a radiation shield. The most thermal load of a cryochamber occurs through the cold finger.

가스차단기내 아크의 복사에너지 측정에 관한 연구 (Study on the Measurement of Radiation Energy of the Arc in GCBs)

  • 송기동;오연호;정진교;조용성
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2122-2126
    • /
    • 2007
  • A special PM-Tube(Photo Multiplier Tube) that is using the photoelectric effect has been designed and manufactured to measure the radiation energy of arc in a gas circuit breaker(GCB). The PM-Tube, LLG(liquid light guides), ND(neutral density) filter, and a model gas circuit breaker have been combined for the reception and the transmission of the light and a simplified synthetic test facility with the arc energy measuring system has been established. In the case of $SF_6$ gas pressure $5kg.f/cm^2$ and arc length 20mm, the radiation energy increases with the arc current but it tend to be saturated in the above 20kA. Under the arc current 20kA, the total radiation energy has the biggest value around 8kA and was not exceeded 40% of the total arc energy.