• Title/Summary/Keyword: Radiation indicator

Search Result 115, Processing Time 0.031 seconds

UV-B-Induced Changes in Carbohydrate Content and Antioxidant Activity in Rice Seedling

  • Sung Jwa-Kyung;Lee Su-Yeon;Park So-Hyun;Jang Byoung-Choon;Lee Sang-Min;Lee Yong-Hwan;Choi Du-Hoi;Song Beom-Heon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.2
    • /
    • pp.84-90
    • /
    • 2005
  • The effects of UV-B radiation on the seedling growth, carbohydrate metabolism and antioxidants activities of rice (Oryza sativa L.) were investigated under environmentally controlled chamber. Supplementary UV­B radiation reduced dry matter as well as leaf area, there­fore, relative growth rates (RGR) of seedlings were decreased by up to half compared to control. Photosynthetic products such as soluble sugars and starch were rapidly and significantly reduced by within 1 day of enhanced UV-B radiation due to the inhibition and degradation of photosynthetic processes and thylakoid membrane integrity. In our study, nonstructural carbohydrate levels were proved to be a main indicator on UV-B­induced stress. The behavior of SOD, CAT, APX and POD activities was monitored in the leaves of rice seedlings subjected to UV-B radiation. Under UV-B treatments, SOD activity was initially increased, whereas CAT and POD activities were slowly and slightly increased. However, APX activity showed no presumable results with an increase of UV-B dose. In leaves of rice seedlings, supplementary UV-B radiation caused an increase in free putrescine and spermidine, however spermine remained unaltered, although 24-hrs UV-B treatment slightly increased. This result presumes that an excess UV-B dose may induce ethylene biosynthesis (senescence) rather than polyamine biosynthesis (defense).

Haptic recognition of the palm using ultrasound radiation force and its application (초음파 방사힘을 이용한 손바닥의 촉각 인식과 응용)

  • Kim, Sun Ae;Kim, Tae Yang;Lee, Yeol Eum;Lee, Soo Yeon;Jeong, Mok Kun;Kwon, Sung Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.467-475
    • /
    • 2019
  • A high-intensity ultrasound wave generates acoustic streaming and acoustic radiation forces when propagating through a medium. An acoustic radiation force generated in a three-dimensional space can produce a solid tactile sensation, delivering spatial information directly to the human skin. We placed 154 ultrasound transmit elements with a frequency of 40 kHz on a concave circular dish, and generated an acoustic radiation force at the focal point by transmitting the ultrasound wave. To feel the tactile sensation better, the transmit elements were excited by sine waves whose amplitude was modulated by a 60 Hz square wave. As an application of ultrasonic tactile sensing, a region where tactile sense is formed in the air is used as an indicator for the position of the hand. We confirmed the utility of ultrasonic tactile feedback by implementing a system that provides the number of fingers to a machine by receiving the shape of the hand at the focal point where the tactile sense is detected.

Prognostic Role of Hepatoma-derived Growth Factor in Solid Tumors of Eastern Asia: a Systematic Review and Meta-Analysis

  • Bao, Ci-Hang;Liu, Kun;Wang, Xin-Tong;Ma, Wei;Wang, Jian-Bo;Wang, Cong;Jia, Yi-Bin;Wang, Na-Na;Tan, Bing-Xu;Song, Qing-Xu;Cheng, Yu-Feng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1803-1811
    • /
    • 2015
  • Hepatoma-derived growth factor (HDGF) is a novel jack-of-all-trades in cancer. Here we quantify the prognostic impact of this biomarker and assess how consistent is its expression in solid tumors. A comprehensive search strategy was used to search relevant literature updated on October 3, 2014 in PubMed, EMBASE and WEB of Science. Correlations between HDGF expression and clinicopathological features or cancer prognosis was analyzed. All pooled HRs or ORs were derived from random-effects models. Twenty-six studies, primarily in Eastern Asia, covering 2,803 patients were included in the analysis, all of them published during the past decade. We found that HDGF overexpression was significantly associated with overall survival (OS) ($HR_{OS}=2.35$, 95%CI=2.04-2.71, p<0.001) and disease free survival (DFS) ($HR_{DFS}=2.25$, 95%CI =1.81-2.79, p<0.001) in solid tumors, especially in non-small cell lung cancer, hepatocellular carcinoma and cholangiocarcinoma (CCA). Moreover, multivariate survival analysis showed that HDGF overexpression was an independent predictor of poor prognosis ($HR_{OS}=2.41$, 95%CI: 2.02-2.81, p<0.001; $HR_{DFS}=2.39$, 95%CI: 1.77-3.24, p<0.001). In addition, HDGF overexpression was significantly associated with tumor category (T3-4 versus T1-2, OR=2.12, 95%CI: 1.17-3.83, p=0.013) and lymph node status (N+ versus N-, OR=2.37, 95%CI: 1.31-4.29, p=0.03) in CCA. This study provides a comprehensive examination of the literature available on the association of HDGF overexpression with OS, DFS and some clinicopathological features in solid tumors. Meta-analysis results provide evidence that HDGF may be a new indicator of poor cancer prognosis. Considering the limitations of the eligible studies, other large-scale prospective trials must be conducted to clarify the prognostic value of HDGF in predicting cancer survival.

SURFICIAL DISINFECTION OF ESCHERIACHIA COLI-CONTAMINATED PLAYGROUND SOIL BY UV IRRADIATION

  • Kim, Jae-Eun;Kim, Tong-Soo;Cho, Shin-Hyeong;Cho, Min;Yoon, Je-Yong;Shea, Patrick J.;Oh, Byung-Taek
    • Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.64-71
    • /
    • 2007
  • The necessity of disinfecting playground soil is an important issue, because pathogenic protozoa, bacteria, and parasite eggs remain viable for several months and can infect children. UV irradiation has been used to decontaminate water but its effectiveness on soil is unclear. We determined the efficacy of UV radiation for inactivation of an indicator bacteria, E. coli (strain ATCC 8739), on playground soil. While 99% inactivation of E. coli in the soil was readily achieved by UV radiation within 55 min at $0.4\;mW\;cm^{-2}$, complete inactivation was not achieved, even after prolonged treatment at $4\;mW\;cm^{-2}$. This was attributed to the irregular surface of the soil. A small number of E. coli escaped the UV radiation because they were situated in indentations or under small particles on the soil surface. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) confirmed that the surface characteristics of the soil is the major limiting factor in the inactivation of E. coli by UV radiation. Thus UV treatment may not be adequate for disinfecting some soils and should be carefully evaluated before being used on playground soils.

Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System (Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교)

  • Kang, Sang-Mook;Chol, Chang-Il;Lee, Seung-Kyu;Park, Sang-Ki;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.26-33
    • /
    • 2010
  • A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using $^{75}Se$ and $^{192}Ir$ with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of $^{75}Se$ and $^{192}Ir$.

Radiotoxicity flux and concentration as complementary safety indicators for the safety assessment of a rock-cavern type LILW repository

  • Jo, Yongheum;Han, Sol-Chan;Ok, Soon-Il;Choi, Seonggyu;Yun, Jong-Il
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1324-1329
    • /
    • 2018
  • This study presents a practical application of complementary safety indicators, which can be applied in a safety assessment of a radioactive waste repository by excluding a biosphere simulation and comparing the artificial radiation originating from the repository with the background natural radiation. Complementary safety indicators (radiotoxicity flux from geosphere and radiotoxicity concentration in seawater) were applied in the safety assessment of a rock-cavern type low and intermediate level radioactive waste (LILW) repository in the Republic of Korea. The natural radionuclide ($^{40}K$, $^{226,228}Ra$, $^{232}Th$, and $^{234,235,238}U$) concentrations in the groundwater and seawater at the Gyeongju LILW repository site were measured. Based on the analyzed concentrations of natural radionuclides, the levels of natural radiation were determined to be $8.6{\times}10^{-5}$ - $8.0{\times}10^{-4}Sv/m^2/yr$ and $6.95{\times}10^{-5}Sv/m^3$ for radiotoxicity flux from the geosphere and radiotoxicity concentration in seawater, respectively. From simulation results obtained using a Goldsim-based safety assessment model, it was determined that the radiotoxicity of radionuclides released from the repository is lower than that of the natural radionuclides inherently present in the natural waters. The applicability of the complementary safety indicators to the safety case was discussed with regard to reduction of the uncertainty associated with biosphere simulations, and communication with the public.

A Study on the Application of PbI2 Dosimetry for QA in the Electron Beam Therapy (전자선 치료의 선량 측정 QA를 위한 PbI2 선량계 적용 연구)

  • Yang, Seungwoo;Han, Moojae;Jung, Jaehoon;Choi, Yunseon;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.517-522
    • /
    • 2020
  • Electron beam have many factors that affect dose distribution, so even if identical settings are used, they should be identified and used for radiation treatment, and the effects on the structures in the body are sensitive, making it difficult to investigate uniform dose distribution on tumors. In this study, a dosimeter was produced using PbI2 which is a photoelectric material, and electrical characteristics were analyzed for 6, 9, and 12 MeV electronics in linear accelerators. The reproducibility test results showed that RSD were 1.1215%, 1.0160%, and 0.05137% respectively at 6, 9, and 12 MeV energies, indicating that the output signals were stable. The linearity evaluation results showed that the R2 values of the reliability indicator for straight line trend lines were 0.9999, 0.9999, and 0.9994, respectively, at 6, 9, and 12 MeV, to confirm that the output signal was proportional to PbI2 as dose increased. The PbI2 dosimeter in this study is judged to be highly applicable to electromagnet measurement and is thought to be able to be used as a basic study of electron detector through photoelectric material.

Prognostic value of neutrophil-to-lymphocyte ratio in locally advanced non-small cell lung cancer treated with concurrent chemoradiotherapy

  • Park, Eun Young;Kim, Yeon-Sil;Choi, Kyu Hye;Song, Jin Ho;Lee, Hyo Chun;Hong, Sook-Hee;Kang, Jin-Hyoung
    • Radiation Oncology Journal
    • /
    • v.37 no.3
    • /
    • pp.166-175
    • /
    • 2019
  • Purpose: This study aimed to investigate neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) as prognostic factors in patients with locally advanced non-small cell lung cancer (NSCLC) who received concurrent chemoradiotherapy (CCRT). Materials and Methods: We retrospectively analyzed 66 patients with locally advanced NSCLC treated with definitive CCRT. Among these patients, 95% received paclitaxel/carboplatin or docetaxel/cisplatin. The median radiation dose was 66 Gy in 33 fractions. The NLR and PLR before/after CCRT were evaluated. The maximally selected log-rank test was used to obtain the cutoff values related to the overall survival (OS). Results: Patients with high post-CCRT NLR (>3.12) showed worse OS, locoregional progression-free survival (LRPFS), and distant metastasis-free survival (DMFS) than those with low NLR (2-year OS: 25.8% vs. 68.2%, p < 0.001; 2-year LRPFS: 12.9% vs. 33.8%, p = 0.010; 2-year DMFS: 22.6% vs. 38.2%, p = 0.030). Patients with high post-CCRT PLR (>141) showed worse OS and LRPFS than those with low PLR (2-year OS: 37.5% vs. 71.1%, p = 0.004; 2-year LRPFS: 16.5% vs. 40.3%, p = 0.040). Patients with high NLR change (>1.61) showed worse OS and LRPFS than those with low NLR change (2-year OS: 26.0% vs. 59.0%, p < 0.001; 2-year LRPFS: 6.8% vs. 31.8%, p = 0.004). The planning target volume (hazard ration [HR] = 2.05, p = 0.028) and NLR change (HR = 3.17, p = 0.025) were the significant factors for OS in the multivariate analysis. Conclusion: NLR change after CCRT was associated with poor prognosis of survival in patients with locally advanced NSCLC. An elevated NLR after CCRT might be an indicator of an increased treatment failure risk.

A Sensitivity Analysis of Accuracy for COMS Outgoing Longwave Radiation Product

  • Kim, Hyunji;Han, Kyung-Soo;Lee, Chang Suk;Shin, Inchul
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • Outgoing Longwave Radiation (OLR) is emitted energy from the Earth that is an important indicator of cooling effect in global scale and meteorological events in regional scale. Satellite-driven OLR products have its advantages overcoming spatially limited representation. The Korean geostationary satellite, Communication, Ocean and Meteorological Satellite (COMS), has been producing OLR product in accordance with its own algorithm since Apr. 2011. This study introduces Spatio-Temporally Equalized Match-up (STEM) approach to evaluate the COMS OLR products. We have tested a number of cases of thresholds set by standard deviations of a subpixel $10.8{\mu}m$ to find optimal representation of OLR in the selective match-up. Each case was then validated with broadband reference data, Clouds and the Earth's Radiant Energy System (CERES). We found that selective STEM approach was useful to validate OLR product especially its distribution in homogeneous grids.

Change in radiation characteristics outside the SNF storage container as an indicator of fuel rod cladding destruction

  • Rudychev, V.G.;Azarenkov, N.A.;Girka, I.O.;Rudychev, Y.V.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3704-3710
    • /
    • 2021
  • The characteristics of the external radiation on the surface of the casks for spent nuclear fuel (SNF) storage by dry method are investigated for the case when the spatial distribution of SNF in the basket changes due to the destruction of the fuel rod claddings. The surface areas are determined, where the changes in fluxes of neutrons, produced by 244Cm actinide, and γ-quanta, produced by long-lived isotopes, are maximum in the result of the decrease in the height of the SNF area. Concrete (VSC-24) and metal (SC-21) casks are considered as examples. The procedure of periodic measurement of the dose rate of neutrons or γ-quanta at the specified points of the cask surface is proposed for identifying the fuel rod cladding destruction. Under normal operation, the decrease in the dose rate produced by neutrons as the function of SNF storage duration is determined by the half-life of 244Cm, and for γ-quanta - by the half-lives of long-lived SNF isotopes. Consequently, a stepwise change in the dose rate of neutrons or γ-quanta, detected by the measurements, as compared to the previous one, would indicate the destruction of the fuel rod claddings.