• Title/Summary/Keyword: Radiation exposure management

Search Result 244, Processing Time 0.028 seconds

Terms Standardization between the Rules of Diagnosis Radiation Equipment Safety Management and Atomic Energy Law : Problems and Suggestions (진단용 방사선발생장치의 안전관리에 관한 규칙과 원자력법의 용어통일 개선 방향)

  • Kim, Hwa-Gon;Kang, Se-Sik;Kim, Chang-Soo;Park, Cheol-Seo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.39-46
    • /
    • 2006
  • The rules and terms are described different meaning, in this results the research is accomplished for preventing practical workers from confusion. Atomic law are kept up modification and development in our situation by the ICRP's recommendation, on the other hand, the rules of diagnosis radiation equipment safety managements are modified partial, then resulted in confusion. The study was comparison between the rules of diagnosis radiation equipment safety management and atomic energy law, and the modification items obtained were as follows. 1. With each other different the terms and units are used. With the exception of special terms for affairs usage, it is needless to say that common term uniformity is standardized. The standardization of rules and guidance have not need to confusion radiological practical workers. 2. The following is omitted. 1) The radiation protection against tile patient and the hospital visitor. 2) Radiation dose limit of the woman patient who is in the process of becoming pregnant. 3) Radiation dose limit of the person who is not regarded as madical madical exposure. 4) The control of the exposure of pregnant of women at work.

  • PDF

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

Knowledge, Attitude, and Practice of Radiation Management among Radiation Generating Device Manufacturers and Medical Personnel (방사선 발생장치 제조업체 및 의료기관 종사자의 방사선 관리에 대한 지식, 태도 및 실천)

  • Kim, Kyu-Hwan;Bae, Seok-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.418-426
    • /
    • 2021
  • This study investigates the perception of radiation safety management in radiation generator manufacturing workers and medical institutions. The basic data obtained is further applied to improve active coping ability and safety levels. The knowledge and attitude practice score of radiation was found to be related to gender, age, marital status, occupation, position, current work period, total work period, radiation related work period, the manual available, defense facility maintenance, number of defense equipment, radiation safety education, special health examination, and recognition of radiation terms. In particular, the knowledge score of radiologists was highest among the radiation-related occupations (<0.05). Radiation safety management requires active defense endeavors to prevent radiation exposure, by both workers of radiation manufacturers and medical institutions. Moreover, institutional devices such as compliance with guidelines, periodic education, facility reinforcement, manual preparation, and special health checkups are required for efficient radiation safety management.

Development of a Portable Device Based Wireless Medical Radiation Monitoring System (휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발)

  • Park, Hye Min;Hong, Hyun Seong;Kim, Jeong Ho;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.150-158
    • /
    • 2014
  • Radiation-related practitioners and radiation-treated patients at medical institutions are inevitably exposed to radiation for diagnosis and treatment. Although standards for maximum doses are recommended by the International Commission on Radiological Protection (ICPR) and the International Atomic Energy Agency (IAEA), more direct and available measurement and analytical methods are necessary for optimal exposure management for potential exposure subjects such as practitioners and patients. Thus, in this study we developed a system for real-time radiation monitoring at a distance that works with existing portable device. The monitoring system comprises three parts for detection, imaging, and transmission. For miniaturization of the detection part, a scintillation detector was designed based on a silicon photomultiplier (SiPM). The imaging part uses a wireless charge-coupled device (CCD) camera module along with the detection part to transmit a radiation image and measured data through the transmission part using a Bluetooth-enabled portable device. To evaluate the performance of the developed system, diagnostic X-ray generators and sources of $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, and $^{90}Sr$ were used. We checked the results for reactivity to gamma, beta, and X-ray radiation and determined that the error range in the response linearity is less than 3% with regard to radiation strength and in the detection accuracy evaluation with regard to measured distance using MCNPX Code. We hope that the results of this study will contribute to cost savings for radiation detection system configuration and to individual exposure management.

A Randomized Controlled Trial about the Levels of Radiation Exposure Depends on the Use of Collimation C-arm Fluoroscopic-guided Medial Branch Block

  • Baek, Seung Woo;Ryu, Jae Sung;Jung, Cheol Hee;Lee, Joo Han;Kwon, Won Kyoung;Woo, Nam Sik;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.26 no.2
    • /
    • pp.148-153
    • /
    • 2013
  • Background: C-arm fluoroscope has been widely used to promote more effective pain management; however, unwanted radiation exposure for operators is inevitable. We prospectively investigated the differences in radiation exposure related to collimation in Medial Branch Block (MBB). Methods: This study was a randomized controlled trial of 62 MBBs at L3, 4 and 5. After the patient was laid in the prone position on the operating table, MBB was conducted and only AP projections of the fluoroscope were used. Based on a concealed random number table, MBB was performed with (collimation group) and without (control group) collimation. The data on the patient's age, height, gender, laterality (right/left), radiation absorbed dose (RAD), exposure time, distance from the center of the field to the operator, and effective dose (ED) at the side of the table and at the operator's chest were collected. The brightness of the fluoroscopic image was evaluated with histogram in Photoshop. Results: There were no significant differences in age, height, weight, male to female ratio, laterality, time, distance and brightness of fluoroscopic image. The area of the fluoroscopic image with collimation was 67% of the conventional image. The RAD ($29.9{\pm}13.0$, P = 0.001) and the ED at the left chest of the operators ($0.53{\pm}0.71$, P = 0.042) and beside the table ($5.69{\pm}4.6$, P = 0.025) in collimation group were lower than that of the control group ($44.6{\pm}19.0$, $0.97{\pm}0.92$, and $9.53{\pm}8.16$), resepectively. Conclusions: Collimation reduced radiation exposure and maintained the image quality. Therefore, the proper use of collimation will be beneficial to both patients and operators.

A Study on the Exposure Dose of Workers and Frequent Workers in the Radiology Department (방사선(학)과의 작업종사자와 수시출입자의 교내 실습에 따른 피폭선량에 대한 고찰)

  • Jeon, Seong-Min;Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.355-359
    • /
    • 2021
  • In this study, the purpose of this study was to analyze the degree of exposure of radiation workers assigned to the Department of Radiology and frequent visitors during on-campus practice, and to conduct a basic study on the feasibility and optimization of the radiation protection of the Nuclear Safety Act for the Department of Radiology. . The average exposure dose of occupational workers by year was 0.01 mSv, the lowest in 2014 and 2016. The highest figure was 0.12 mSv in 2018. The average exposure dose of frequent visitors by year was the lowest at 0.013 mSv in 2018, and the highest at 0.022 mSv in 2016. According to this study, the annual exposure dose received by professors, practical assistants, and students in the department of radiology (department) who use only radiation generators in the course of in-school practice is less than 1 mSv, which is the dose limit for the general public. Therefore, at the time when the radiation dose of students in the Department of Radiology is lower than the dose limit of the general public, the current safety regulation of the Nuclear Safety law is judged to be excessive regulation. Therefore, it is considered necessary to revise the regulations for radiation generators in the current Nuclear Safety law or to revise the radiation safety management system for university students.

Literature Review on Cosmic Radiation Exposure to Air Craft Cabin Crew (항공기 객실승무원의 우주방사선 노출에 관한 고찰)

  • Jang, Ryeo-Jin
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.643-649
    • /
    • 2018
  • Recently, together with advancement of domestic aviation industry, overseas tourists using planes have been soared. This study aimed to investigate the risk of diseases for the passengers and flight attendants from the exposed cosmic radiation during the flight by domestic and international literature reviews, as follows. Airliners should develop the program to measure the actual radiation dose and prepare the portable devices for radiation measurement in flight to lower the accumulated dose of cosmic radiation by the attendants. Regulation should be prepared to check the exposed dose during the flight for the passengers by announcement of individual exposed radiation dose which has been provided only to the flight attendants. Passengers and flight attendants should recognize they are exposed to excessive cosmic radiation during the flight and civilians should be protected by the cosmic radiation when they use the flights, which should be prepared by the regulations.

Relationship between Thoughts and Anxiety about Nuclear Power among Busan Residents (일부 부산지역 주민의 원자력에 대한 생각과 불안감의 관계)

  • Park, Jee Eun;Lee, Samyol;Baek, Cheol-Ha;Kim, Soo Jeong
    • The Korean Journal of Health Service Management
    • /
    • v.13 no.3
    • /
    • pp.137-147
    • /
    • 2019
  • Objectives: This study aimed to identify the relationship between thoughts and psychological anxiety about nuclear power among Busan residents. Methods: Convenience sampling was used for this cross-sectional survey conducted from February 13 to 14, 2016. A total of 520 residents participated in the study and completed a self-administered questionnaire. Results: We found a significant association between negative thoughts and psychological anxiety about nuclear power. People older than 60 years (odds ratio (OR) 2.53, 95% confidence interval (CI) 1.41-4.54), who feared the possibility of radiation accidents (OR 1.75, 95% CI 1.17-2.62), considered nuclear power plants unsafe (OR 1.94, 95% CI 1.10-3.40), and believed the Gori nuclear power plant in Busan must be shut down (OR 1.84, 95% CI 1.22-2.79), had the highest anxiety about radiation exposure. Conclusions: The authors suggest the need for the formulation of a policy to provide people with precise information on nuclear power to increase their understanding and help eliminate unfounded negative thoughts. Furthermore, policy decisions about nuclear power must be based on social consensus.

Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode (실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현)

  • 이운근;백광렬;권석근
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.4
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.

Set Up and Operation for Medical Radiation Exposure Quality Control System of Health Promotion Center (건강검진센터의 의료방사선 피폭 품질관리 시스템 구축 운영 경험 보고)

  • Kim, Jung-Su;Jung, Hae-Kyoung;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT $357.9mGy{\cdot}cm$ in abdomen and pelvic CT, $572.4mGy{\cdot}cm$ in brain without CT, $55.9mGy{\cdot}cm$ in calcium score/heart CT, screening CT at $54mGy{\cdot}cm$ in chest screening CT(low dose screening CT scan), $284.99mGy{\cdot}cm$ in C-spine CT and $341.85mGy{\cdot}cm$ in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows $274.0mGy{\cdot}cm2$ and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.