• Title/Summary/Keyword: Radiation exchange

Search Result 176, Processing Time 0.032 seconds

Relationship between the DNA content of human chromosome and their contribution to radiation-induced chromosome aberration analysed by fluorescence in situ hybridization(FISH) (방사선에 의한 염색체이상과 DNA 함량과의 관계)

  • Chung, Hai-Won;Kim, Su-Young;Ha, Sung-Whan;Kim, Tae-Hwan;Cho, Chul-Koo
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.101-111
    • /
    • 2001
  • To study the relationship between the DNA content of human chromosomes and their involvement in radiation-induced structural chromosome aberrations, the frequencies of translocations and dicentrics induced in human lymphocytes after in vitro exposure to 2Gy of x-tay were analysed by fluorescence in situ hybridization(FISH). Single whole chromosome probes(WCP), specific for chromosomes 1, 2, 4, 7, 8, 9, and 21 and triple combination of probes tot chromosome 1, 2 & 4 were used separately. A significant deviation of the frequency of symmetrical translocation and dicentrics from a DNA-proportional distribution was observed. Chromosomes 2, 7, 8, 9 and 21 were less frequently involved in the formation of symmetrical translocations and dicentrics than expected, whereas chromosomes 1 and 4 were more frequently involved. Chromosome 2 and 4 showed a higher frequency of acentric fragments. When triple combination probe for chromosome 1, 2 & 4 was used, no differences were found between the observed and expected frequency of exchange type aberrations. The results showed that the frequency of radiation-induced chromosome aberrations was not proportional to DNA contents, suggesting the difference in the susceptibility to specific aberrations among individual chromosomes. The results also indicated that the FISH technique with combination of probes for chromosome 1, 2 & 4 was useful for radiation biodosimetry.

  • PDF

Evaluation of DNA Damage and Repair Kinetics in the Earthworm (Eisenia fetida) Exposed to Radiation and Mercury (방사선과 수은에 의해 유도된 Eisenia fetida 체강세포의 DNA 손상 및 수복 평가)

  • Ryu, Tae-Ho;Nili, Mohammad;An, Kwang-Guk;Kim, Jin-Kyu
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.1
    • /
    • pp.68-73
    • /
    • 2011
  • The single cell gel electrophoresis (SCGE) assay is a microelectrophoretic technique for assessments of DNA damage at the level of the individual eukaryotic cell. The SCGE assay, due to its simplicity, sensitivity and need of a few cells, has advantages compared to other genomic damage assays such as sister chromatid exchange, chromosomal aberration and micronucleus test. In this study, investigated were the levels of DNA damage and the repair kinetics in the coelomocytes of Eisenia fetida treated with HgCl2 and ionizing radiation by means of the SCGE assay. For detecting DNA damage and repair in coelomocytes, earthworms (E. fetida) were irradiated with six doses of ${\gamma}$-rays (0, 2.5, 5, 10, 20 and 50 Gy) and in vivo exposed to mercuric chloride at 0, 80 and 160 mg $kg^{-1}$ for 48 hours. Then the Olive tail moments were measured during 0~12 hours after irradiation and 0~72 hours after Hg treatment. The results showed that the more the oxidative stress was induced by mercury and radiation, the longer the repair time was required. Also, the results suggest that the SCGE assay may be used as an important tool for comparison of the sensitivity of different species to oxidative stresses.

Ion Exchange Phenomena of $Cs^{+1},\;Sr^{+2},\;and\;Th^{+4}$ on Ion Exchange Resin in Loading and Elution Process ($Cs^{+1},\;Sr^{+2}$$Th^{+4}$가 동시에 이온교환수지에 흡착 및 탈착시의 이온교환현상)

  • Park, Chong-M.;Walter, Meyer
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.2
    • /
    • pp.104-113
    • /
    • 1986
  • The ion exchange behaviour of the $Cs^{+1},\;Sr^{+2},\;and\;Th^{+4}$ in the system of $Cs^{+1},\;Sr^{+2},\;Th^{+4},\;and\;7Cl^{-}-H^{+}$ from Dowex HCR-W2, was examined in the loading and elution processes. $Th^{+4}$ was slowly adsorbed through the entire contact time between resin and solution and $Cs^{+1}\;and\;Sr^{2+}$ were adsorbed fast for the first few minutes of contact time. Because of the strong affinity of $Th^{+4}$, the longer contact time was allowed, the less amount of $Cs^{+1}\;and\;Sr^{2+}$ was adsorbed on the resin. The peak concentration of the resin phase $Cs^{+1}$ in the solution concentration of $Cs^{+1}:Sr^{+2}:Th^{+4}$ in the ratio of 2 : 2 : 1 in normality with total normality of 0.1N was produced at about 4 minutes of contact time and the peak time for $Sr^{+2}$ was 20 minutes. The loaded ions were eluted using hydrochloric acid. The loaded $Cs^{+1}$ was eluted at the low eluent concentration of less than 0.1N with less than 5% contamination of $Sr^{+2}$. The loaded $Th^{+4}$ was eluted at the high eluent concentration of greater than 1N. The best eluent concentration for eluting $Th^{+4}$ was 4N.

  • PDF

Prediction of the Apparent Temperature of an Object under the Infrared Waveband (적외선 파장대에서의 물체의 겉보기온도 예측)

  • Jung, Jinsoo;Kauh, S. Ken;Yoo, Hoseon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.352-363
    • /
    • 1999
  • Target detection by the infrared imager depends on the apparent temperature difference between the target and the background, so it is essential to predict apparent temperature variations for this purpose. In this study, thermal analysis program Including conduction, convection and radiation is developed and applied to a representative geometry adequate for examining the apparent temperature characteristics. The results show that the longwave emissivity in association with the background temperature affects the apparent temperature strongly but does not affect the physical temperature. It is revealed that the background temperature plays a role of tuning the apparent temperature. As the longwave emissivity decreases, the apparent temperature decreases when the target is hotter than the background, whereas it increases in the reversed situation. These findings imply that an effective surface treatment, such as painting of a less emissive material, may provide a less detection probability and contribute to preventing the target from being detected at night.

Studies on the Physico-chemical Properties of Mixed Radioactive Waste Glass

  • Kim, C.W.;Choi, J.R.;Ji, P.K.;Park, J.K.;Shin, S.W.;Ha, J.H.;Song, M.J.;Hwang, T.W.;Park, S.J.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.33-39
    • /
    • 2004
  • In order to vitrify the W1 waste (ion-exchange resin(IER), zeolite, and dry active waste(DAW)) generated from Korean Nuclear Power Plants, a glass formulation development based on waste compositions and production rates was performed. A aluminoborosilicate glass, AG8W1, was formulated to vitrify the W1 waste in an induction cold crucible melter(CCM). The processability, product performance, and economics of the candidate glass were calculated using a computer code and were measured experimentally in the laboratory and CCM. The glass viscosity and electrical conductivity as the process parameters were in the desired ranges. Start-up and maintaining glass melt of the candidate glass were favorable in the CCM. The product quality of the glass such as chemical durability, phase stability, etc. was satisfactory. The vitrification process using the candidate glass was also evaluated to be operated as economically as possible.

Analysis and Calculation of Hourly Surface Temperature Based on Typical Meterorological Data for Major Cities in Korea (국내 주요도시의 표준기상자료를 이용한 시간당 표면온도 산출 및 분석)

  • Lee, Kwan-Ho;Cho, Hyun-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.123-128
    • /
    • 2012
  • Computer simulation of buildings and solar energy systems is being used increasingly in energy assessments and design. The purpose of our work is to predict the surface temperature on inclined surfaces based on ISO-TRY typical weather data. To reach this goal, three studies were performed. They consisted of quantifying the accuracy of various well-known three models. The first type of models calculated diffuse horizontal irradiations from global ones and the second type models computed global irradiations on inclined planes from diffuse and global components on a horizontal surface. The third type of model calculated long-wave radiation and surface temperature from ISO-TRY typical weather data. The proposed model can provide an alternative to building designers in estimating the surface temperature and solar irradiation on inclined surfaces where only the typical meteorological data are available.

2D Heat Transfer Model for the Prediction of Temperature of Slab in a Direct-Fired Reheating Furnace (가열로 내 슬랩의 온도 예측을 위한 2차원 열전달 모델)

  • Lee Dong-Eun;Park Hae-Doo;Kim Man-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.950-956
    • /
    • 2006
  • A mathematical heat transfer model for the prediction of heat flux on the slab surface and temperature distribution in the slab has been developed by considering the thermal radiation in the furnace and transient conduction governing equations in the slab, respectively. The furnace is modeled as radiating medium with spatially varying temperature and constant absorption coefficient. The slab is moved with constant speed through non-firing, charging, preheating, heating, and soaking zones in the furnace. Radiative heat flux which is calculated from the radiative heat exchange within the furnace modeled using the FVM by considering the effect of furnace wall, slab, and combustion gases is applied as the boundary condition of the transient conduction equation of the slab. Heat transfer characteristics and temperature behavior of the slab is investigated by changing such parameters as absorption coefficient and emissivity of the slab. Comparison with the experimental work shows that the present heat transfer model works well for the prediction of thermal behavior of the slab in the reheating furnace.

Removal of Organic Matter and Nutrient in Swine Wastewater Using a Membrane System

  • Lim, Seung Joo;Kim, Sun Kyong;Lee, Yong-gu;Kim, Tak-Hyun
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.75-82
    • /
    • 2012
  • Swine wastewater was treated using a unique sequence of ion exchange membrane bed system (IEBR). Organic matter and nutrient in swine wastewater was pre-treated by electron beam irradiation. The optimal dose for solubilization of organic matter in swine wastewater ranged from 20 kGy to 75 kGy. The carbohydrates, proteins, and lipids were investigated as the solubilized organic fraction of swine wastewater and proteins and lipids mainly contained of the solubilized organic matter. The solubilization of organic matter in swine wastewater was affected by the combination effect of temperature and a dose. The average chemical oxygen demand (COD) removal efficiency under room temperature conditions was 67.1%, while that under psychrophilic conditions was 54.6%. For removal of ammonia, the removal efficiency decreased from 63.6% at $23^{\circ}C$ to 33.5% $16.8^{\circ}C$. On the other hand, the removal of phosphorus was not a function of temperature. Struvite was one of main mechanisms in anaerobic condition.

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

Therapeutic Feasibility Study and Clinical Trial of Intrahepatic $I^{-131}-Lipiodol$ on Patients with Hepatocellular Carcinoma ($Lipiodol-I^{-131}$의 경간동맥 주입에 의한 간암치료의 가능성에 관한 연구)

  • Yoo, Hyung-Sik;Suh, Jung-Ho;Lee, Jong-Tae;Kim, Dong-Ik;Park, Chang-Yun;Kim, Byung-Soo;Park, Chan-H.;Thakur, M.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.61-71
    • /
    • 1986
  • An iodized oil such as Ethiodol or Lipiodol was selectively retained in the tumor vessels of the large hepatomas as well as in the small daughter hepatomas for long periods following the intra-arterial hepatic injection of such contrast material. The specific aim of the study is to deliver a high internal radiation dose to hepatocellular carcinoma (HCC) in an attempt to control the disease. We were able to replace a small fraction of the stable iodine (I-127) of the 37% iodine in Lipiodol by the $I^{-131}$ with 100% exchange efficiency. $I^{-131}$ labeled Lipiodol was injected through the super-selected tumor feeding artery under superselection or into the proper hepatic arterial level of patients who have malignant hepatomas confirmed by aspiration cytology serum AFP and various imaging modalities. Clinical traial was performed on 43 cases during recent 6 months and follow-up observation was carried out. No severe complications or other adverse reactions were encountered until nowdays. $I^{-131}-Lipiodol$ was stable in vivo and no significant activity was noted in the thyroid, stomach, blood and urine after the injection. Only small fraction of radioisotope activity was noticed in the both side of lungs. Tumor to normal liver radio was very high. Therefore, $I^{-131}-Lipiodol$ (or P-32-Lipiodol) will be effective delivering high internal radiation dose to the tumor while delivering small radiation doses to normal tissues. Labeling, tumor dose calculation and preliminary findings will be presented.

  • PDF