• 제목/요약/키워드: Radiation effect

검색결과 3,596건 처리시간 0.035초

A Noise Re-radiation Calibration Technique in Interferometric Synthetic Aperture Radiometer for Sub-Y-type Array at Ka-Band

  • Seo Seungwon;Kim Sunghyun;Choi Junho;Park Hyuk;Lee Hojin;Kim Yonghoon;Kang Gumsil
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.577-580
    • /
    • 2004
  • To overcome with large size noise source distribution network design difficulty in interferometric radiometer system, especially for sub-Y-type array, a new on-board calibration technique using noise re-radiation is proposed in this paper. The suggested calibration technique is using noise re-radiation effect of center antenna after noise source injection from matched load. This approach is especially proper to sub-Y-type array interferometric synthetic aperture radiometer in mm-wave frequency band. Compared with noise injection network of a conventional synthetic aperture radiometer, the system mass, volume, and hardware complexity is reduced and cost-effective. Only one internal noise source, matched load, is used for injection using noise re-radiation technique a small set of sub-Y receiver channels is calibrated. Detailed calibration scenario is discussed and simulation results about noise re­radiation effect are presented.

  • PDF

Status of Radiation Dose and Radioactive Contamination due to the Fukushima Accident

  • Baba, Mamoru
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.133-140
    • /
    • 2016
  • Backgrounds: The accident at Fukushima Daiichi Nuclear Power Plant (NPP), March 2011, caused serious radioactive contamination over wide area in east Japan. Therefore, it is important to know the effect of the accident and the status of NPP. Materials and Methods: This paper provides a review on the status of radiation dose and radioactive contamination caused by the accident on the basis of publicized information. Results and Discussion: Monitoring of radiation dose and exposure dose of residents has been conducted extensively by the governments and various organizations. The effective dose of general residents due to the accident proved to be less than a mSv both for external and internal dose. The equivalent committed dose of thyroid was evaluated to be a few mSv in mean value and less than 50 mSv even for children. Monitoring of radioactivity concentration has been carried out on food ingredients, milk and tap water, and actual meal. These studies indicated the percentage of foods above the regulation standard was over 10% in 2011 but decreasing steadily with time. The internal dose due to foods proved to be tens of ${\mu}Sv$ and much less than that due to natural $^{40}K$ even in the Fukushima area and decreasing steadily, although high level concentration is still observed in wild plants, wild mushrooms, animals and some kind of fishes. Conclusion: According to extensive studies, not only the effect of the accident but also the pathway and countermeasures against radioactive contamination have been revealed, and they are applied very effectively for restoration of environment and reconstruction of the area.

고에너지 방사선으로 단일조사한 백서위의 병리조직학적 변화에 관한 연구 (The Pathological Changes of Stomach in Experimental Rats following Single Irradiation of Supervoltage)

  • 최명선;서원혁
    • Radiation Oncology Journal
    • /
    • 제2권1호
    • /
    • pp.25-32
    • /
    • 1984
  • The pathological changes of stomach of the rat following 1,000 rad and 1,800 rad single exposure by Cobalt-60 has been made with 50 experimental rats. The dose of 1,000 rad and 1,800 rad single exposure were equivalent of biologic effect of 2,500 rad in 2 1/2 weeks and 6,000 rad in 6 weeks. Following single exposure, the groups of rat were terminated in 1, 2, 4, 8, 12 weeks intervals and the stomach were fixed to formalin solution immediatly after dissection. The pathological changes were as follows : 1. Following 1,000 rad single exposure, the stomach show only mild to moderate submucosal edema in 4,8,12 weeks group. 1 and 2 weeks group show no changes. 2. Following 1,800 rad single exposure, $32\%(8/25)$ of rats were dead by radiation effect and all other groups of stomach revealed variable pathological changes such as submucosal edema, squamous dysplasia, squamous papilloma as well as squamous cell carcinoma. 3. Optimal tolerance dose to the stomach was $4,500\~5,000$rad when irradiation given by supervoltage. The entire stomach was included within the irradiation field, the dose to the stomach should not exceed 6,000 rad. 4. In conclusion, the radiation injury to the stomach were more direct radiation effects to the gastric mucosa rather than secondary changes of radiation injured vessels.

  • PDF

반복 온열료법이 방사선조사효과에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Repeated Hyperthermia on the Radiation Injury)

  • 최 영희;박찬일;한만청
    • Radiation Oncology Journal
    • /
    • 제2권1호
    • /
    • pp.1-9
    • /
    • 1984
  • To evaluate the influence of prior heat treatment on the thermal enhancement of irradiation effect after hyperthermia, an experimental study was carried out using a total of 80 mice. Hyperthermia was carried out at $43^{\circ}C$ for 40 minutes and was repeated with various intervals. A single dose of 3,000 rad was delivered on skin of mouse tail immediately after the second hyperthermia. The skin changes of the irradiated mouse tail were observed from 7th to 35th post-irradiation days, and the skin scores were analyzed. The results are as follows, 1. The radiation damage on mouse skin increased significantly when radiation was combined with hyperthermia. 2. The radiation damage after repeated hyperthermia is significantly less than that after single hyperthermia, when the interval is 1 to 6 days. 3. As a result, thermal tolerance persists from 1 through 6 days after the initial hyperthermia.

  • PDF

과도방사선 조건에서 PN다이오드소자의 방사선 영향분석 (The Study of Latch-up)

  • 오승찬;정상훈;황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.791-794
    • /
    • 2013
  • 본 연구에서는 초기 핵 방사선 조건에서 반도체소자의 과도응답특성을 분석하기 위한 선행연구의 일환으로 반도체 소자의 과도방사선에 의한 영향에 대한 주요원인과 반도체의 물성, 설계구조, 공정방식의 조건에 따라 소자내부에 생성되는 광전류 거동특성에 대한 정략적인 분석을 위한 시뮬레이션 분석을 수행하였으며 결과적으로 반도체소자의 설계조건과 입력되는 과도방사선의 선량율에 따른 비선형 특성을 확인하였다.

  • PDF

날아가는 섬광탄이 연료탱크 수평핀에 미치는 복사열전달 연구 (An Investigation of Radiation Heat Transfer on The Horizontal Fin of An External Fuel Tank by Flame of a Flying Flare)

  • 정대한;강치행;김시태
    • 한국군사과학기술학회지
    • /
    • 제17권2호
    • /
    • pp.197-203
    • /
    • 2014
  • In this paper, the effect of unsteady radiation on the horizontal fin of an external fuel tank by flame of a flying flare was analysed to see the temperature increase of the fin and the thermal impact on the fin. Radiation between two surfaces was calculated using the concept of radiation resistance of surface and space including radiation, irradiation and shape factor for two flying trajectories of a flare, maximum temperature of 2200 K, emissivity of 0.95, flying velocity of 30 m/s, and thermal surface area of $0.01m^2$. The result shows that the temperature increase of the fin is 0.236 K, and the thermal effect on the fin is ignorable. And it was found that temperature is increased a little because small amount of heat energy can be radiated due to the short exposure time to the heat source.

Management of Radiation Injuries by Panax ginseng Extract

  • Verma, Preeti;Jahan, Swafiya;Kim, Tae-Hawn;Goyal, Pradeep Kumar
    • Journal of Ginseng Research
    • /
    • 제35권3호
    • /
    • pp.261-271
    • /
    • 2011
  • Chemical radiation protection is an important strategy to protect living beings against the deleterious effects of radiation. In the present study, the radioprotective effect of hydro-alcoholic extract of Panax ginseng extract (PGR-HAE) was studied on radiation-induced deleterious alterations in Swiss albino mice. Oral administration of such extract (25 mg/kg b wt/day/animal) for 5 consecutive days, half an h. before whole-body exposure to 6 Gy gamma radiation, enhanced the 30 days survival and also inhibited the radiogenic sickness, weight loss and life shortening. PGR-HAE ameliorated radiation induced depletion in blood constituents at different necropsy intervals between 12 h to 30 d, and significantly increased the number of femoral spleen colony forming units that survived after irradiation. Furthermore, it checked depletion of glutathione and antioxidant enzymes (superoxide dismutase, catalase, and glutathione S-transferase) as well as elevation of lipid peroxidation (LPO) level in blood and liver. The significant reduction in the yield of LPO demonstrates that PGR-HAE protects the membranes against radiation-induced oxidative damage. These findings conclude that such plant extract provides significant radioprotection, and it may be potentially valuable in the prevention of injuries caused during planned and unplanned radiation exposure.

방사성 물질 등의 이용 증가에 따른 안전 관리 문제점 고찰 (The Increased Use of Radiation Requires Enhanced Activities Regarding Radiation Safety Control)

  • 이윤종;이진우;정교성
    • 방사선산업학회지
    • /
    • 제9권2호
    • /
    • pp.103-109
    • /
    • 2015
  • More recently, companies that have obtained permission to use radioactive materials or radiation device and registered radiation workers have increased by 10% and 4% respectively. The increased use of radiation could have an effect on radiation safety control. However, there is not nearly enough manpower and budget compared to the number of workers and facilities. This paper will suggest a counteroffer thought analyzing pending issues. The results of this paper indicate that there are 47 and 31.3 workers per radiation protection officer in educational and research institutes, respectively. There are 20.1 persons per RPO in hospitals, even though there are 2 RPOs appointed. Those with a special license as a radioisotope handler were ruled out as possible managers because medical doctors who have a special license for radioisotope handling normally have no experience with radiation safety. The number of staff members and budget have been insufficient for safety control at most educational and research institutes. It is necessary to build an optimized safety control system for effective Radiation Safety Control. This will reduce the risk factor of safety, and a few RPOs can be supplied for efficiency and convenience.

Adaptive Response Induced by Low Dose Ionizing Raditation in Human Cervical Carcinoma Cells

  • Kim, Jeong -Hee;Lee, Kyung -Jong;Cho, Chul -Koo;Yoo, Seong -Yul;Kim, Tae -Hwan;Ji, Young -Hoon;Kim, Sung -Ho
    • Archives of Pharmacal Research
    • /
    • 제18권6호
    • /
    • pp.410-414
    • /
    • 1995
  • Adaptive response induced by low dese .gamma.-ray irradiation in human cervical carcinoma cells was examined. Cells were exposured to low dose of .gamma.-ray irradiation in human cervical carcinoma cells was examined. Cells were exposured to low dose of .gamma.-ray (1-cGy) followed by high doses of r-ray irradiation (0,1,2,3,5,7 and 9Gy for chlnogenic assay or 1.5Gy for micronucleus assay) with various time intervals. Survival fractions of cells in both low dose-irradiated and unirrated groups were analyzed by clonogenic assay. Surviva fractions of low dose-irradiated in cell survival was maximum when low and high dose irradiation time interval was 4 hr. Frequencies of micronuclei which is an indicative of chromosome aberration were also enutained from survival fractions analyzed by clonogenic assay, maximum when low and high dose irradiation time interval was 4hr. Frequencies of micronuclei which is an indicative of chromosome aberration were also enumerated in both low dose-irradiated and unirradiated groups. In consiststent with the result obtained from survival fractions analyzed by clonogenic assay, maximum reduction in frquencies of micronuclei was observed when low dose radiation was given 4 hr prior to high response to subsequent high dose .gamma.-ray irradiation in human cervical carcinomal cells. Our data suggest that one of the possible mechanisms of adaptive response induced by low dose rediation is the increase in repair of DNA double strand breaks in low dose radiation-adapted cells.

  • PDF

다목적 방사선 조사장치 개발 및 선량분포특성 (The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution)

  • 이동훈;지영훈;이동한;김윤종;홍승홍
    • 전자공학회논문지SC
    • /
    • 제39권6호
    • /
    • pp.42-48
    • /
    • 2002
  • 다목적 방사선 조사장치의 설계, 제작 및 성능검사에 대해 기술하였다. 세슘-137을 사용한 다목적 방사선조사장치는 생물학에서 저선량 방사선에 대한 영향연구, 혹은 TLD(Thermo Luminescent dosimeter)의 교정을 위해 사용되어진다. 본 조사장치는 방사선 동위원소를 안전한곳에 저장하고 있다가 방사선조사시에만 조사실로 180도 회전하여 설정된 시간만큼 시료에 방사선 조사가 이루어 진 후, 사용이 끝나면 다시 차폐된 저장위치로 복귀하게된다. 제어시스템은 PLC 기반으로 구축하여 저선량율 조사장치의 시제품을 제작하였으며, 또한 컴퓨터를 통해 방사선 조사장치의 제어 및 세부 동작 상태 등을 실시간 검색, 원격제어 및 관리 할 수 있는 종합 관리 프로그램을 개발하였다. 조사실 내부 구성은 시료의 종류에 따라 최대 20RPM까지 다양하게 회전하면서 균일 조사될 수 있도록 조사실 및 챔버를 설계 제작하였으며, 조사실내 넣을 수 있는 조사체 최대 용량은 4.5리터이다. 조사실내의 방사선량의 분포도는 가프크로믹 필름을 사용하여 측정한 결과 2Ci 범위내에서 세슘-137의 경우 공기중에서 0.13cGy/min이었고 일반 물질과 등가인 물에서는 0.11cGy/min로 나타났으며, 오차는 약 ${\pm}$7%의 한도내에서 균일한 분포를 보였다. 또한 실제 누설선량은 조사실 밖 표면에서 최대 0.35mR/hr이였으며 1m 떨어진곳에서는 최대 0.03mR/hr로 허용치 이내였다.