• Title/Summary/Keyword: Radiation effect

Search Result 3,580, Processing Time 0.032 seconds

Numerical Study on the Attenuation Effect of Water Mist on Thermal Radiation (미세물분무에 의한 열복사 감쇠 효과에 대한 수치해석 연구)

  • Ko, Gwon Hyun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.7-12
    • /
    • 2020
  • A numerical study was conducted to investigate the effects of the spray characteristics of water mist on the attenuation of thermal radiation. The attenuation process of the thermal radiation, generated from a hot surface panel, passing through the water mist was calculated via Fire Dynamics Simulator (FDS), and the effects of the flow rate, droplet mean diameter, and spray injecting angle of the water mist were analyzed. The results indicated that the increase in flowrate and decrease in droplet size led to an increase in the attenuation of thermal radiation. As the thermal radiation passed through the spray droplets, the effect of the spatial distribution of spray droplets was verified by calculating the thermal radiation attenuation at different spray injecting angles. The results indicated that the radiation attenuation increases as the spray angle increases. This implies that a wider distribution of spray droplets, irrespective of the droplet size and flowrate, increases the attenuation effect on thermal radiation.

Minimization of Treatment Time Using Partial-Arc Volumetric Modulated Arc Therapy with Bladder Filling Protocol for Prostate Cancer

  • Hojeong Lee;Dong Woon Kim;Ji Hyeon Joo;Yongkan Ki;Wontaek Kim;Dahl Park;Jiho Nam;Dong Hyeon Kim;Hosang Jeon
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.101-107
    • /
    • 2022
  • Purpose: Radiotherapy after bladder filling protocol (BFP) is known to enhance treatment quality and reduce side effects in prostate cancer, a common male solid cancer globally. However, due to the need to hold back urine during treatment, patients frequently complain of discomfort, and treatment is frequently suspended when patients urinate during treatment and urine penetrates the treatment device, causing malfunction. Therefore, the effect of minimizing treatment time when partial-arc volumetric modulated arc therapy (VMAT) was used instead of full-arc was assessed in this study. Methods: A total of 70 plans were created in 10 patients using 7 different arc sizes, and the treatment time for each plan was calculated. Results: Reduced arc size by half resulted in a 54.4% decrease in mean treatment duration, with a proportional tendency observed. Furthermore, the effect of VMAT arc size reduction on target dose homogeneity was significantly limited, and the effect on surrounding organs at risk (OAR) was negligible. It should be noted, however, that when the arc size decreases by >40%, the dose increases in the area without OAR around the target. Conclusions: The results of this study demonstrated that partial-arc VMAT for enhancing treatment convenience and efficacy of prostate cancer patients undergoing BFP can achieve a considerable reduction in treatment time while preserving treatment quality, and it is expected to be useful for partial-arc VMAT plan design and implementation in practice.

A Numerical Analysis on Acoustic Radiation Efficiency of One Side-Wetted Rectangular Mindlin Plate with Simply Supported Boundaries (Mindlin 판 이론을 적용한 단순지지 단면 접수평판의 음향방사효율 수치해석)

  • Lee, Jong-Ho;Cho, Dae-Seung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.4
    • /
    • pp.281-288
    • /
    • 2018
  • Acoustic radiation efficiency is a crucial factor to estimate Underwater Radiated Noise (URN) of ships accurately. This paper describes a numerical method to analyse acoustic radiation efficiency of one side-wetted rectangular Mindlin plate with simply supported boundaries excited by a harmonic point force. Transverse displacements of plate and acoustic radiation pressures are evaluated by the mode superposition method. The acoustic radiation efficiencies analyzed by both Mindlin and thin plate theories show little differences at monopole and corner modes of low frequency regions but relatively large differences at edge and critical modes of high frequency regions. Especially, the critical frequency with the highest acoustic radiation efficiency evaluated by the Mindlin plate theory is higher than that of thin plate theory. In addition, the acoustic loading effect of fluid also increases bending wave-number of plate and its critical frequency. Finally, the acoustic radiation characteristics of plates with different aspect ratios and thicknesses through numerical analyses are investigated and discussed.

Synthesis of a Novel Compound from Gallic Acid and Linoleic Acid and its Biological Functions

  • Jo, Cheo-Run;Jeong, Ill-Yun;Lee, Na-Young;Kim, Kwan-Soo;Byun, Myung-Woo
    • Food Science and Biotechnology
    • /
    • v.15 no.2
    • /
    • pp.317-320
    • /
    • 2006
  • Octadeca-9,12-dienyl-3,4,5-hydroxybenzoate (GA-LA) was chemically synthesized from gallic acid and linoleic acid ester, and its biological functions were tested. Radical-scavenging activity of GA-LA was comparable to those of gallic and ascorbic acids at 0.24 mM, and tyrosinase inhibition effect was higher than that of ascorbic acid. Gallic and linoleic acids did not show any tyrosinase activity. Results of cyclooxygenase (COX) inhibition effect indicate GA-LA has higher selectivity in COX-1 inhibition. GA-LA from gallic and linoleic acids could be used as functional reagent for antioxidative, skin-whitening, and anti-inflammatory effects in food, pharmaceutrical, and cosmetic industries.

Classification of Biological Effect of 1,763 MHz Radiofrequency Radiation Based on Gene Expression Profiles

  • Im, Chang-Nim;Kim, Eun-Hye;Park, Ae-Kyung;Park, Woong-Yang
    • Genomics & Informatics
    • /
    • v.8 no.1
    • /
    • pp.34-40
    • /
    • 2010
  • Radiofrequency (RF) radiation might induce the transcription of a certain set of genes as other physical stresses like ionizing radiation and UV. To observe transcriptional changes upon RF radiation, we exposed WI-38, human lung fibroblast cell to 1763 MHz of mobile phone RF radiation at 60 W/kg of specific absorption rate (SAR) for 24h with or without heat control. There were no significant changes in cell numbers and morphology after exposure to RF radiation. Using quantitative RT-PCR, we checked the expression of three heat shock protein (HSP) (HSPA1A, HSPA6 and HSP105) and seven stress-related genes (TNFRSF11B, FGF2, TGFB2, ITGA2, BRIP1, EXO1, and MCM10) in RF only and RF/HS groups of RF-exposed cells. The expressions of three heat shock proteins and seven stress-related genes were selectively changed only in RF/HS groups. Based on the expression of ten genes, we could classify thermal and non-thermal effect of RF-exposure, which genes can be used as biomarkers for RF radiation exposure.

A Study of Real Time Verification System or Radiation Therapy (방사선치료 위치 실시간 검증시스템에 관한 연구)

  • Kim, Y.J.;Ji, Y.H.;Lee, D.H.;Lee, D.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.164-167
    • /
    • 1997
  • The treatment setup of patients during irradiation is an important aspect in relation to the success of radiotherapy. Imaging with the treatment beam is a widely used method or verification of the radiation field position relative to the target area, prior to or during irradiation. In this paper, Real time digital radiography system was implemented or verification of local error between simulation plan and radiation therapy machine. Portal image can be acquired by CCD camera, image board and pentium PC after therapy Radiation was converted into light by a metal/fluorescent Screen. The resulting image quality is comparable to film, so the imaging system represents a promising alternative to film as a method of verifying patient positioning in radiotherapy. Edge detection and field size measurement were also implemented and detected automatically for verification of treatment position. Field edge was added to the original image or checking the anatomical treatment verification by therapy technicians. By means of therapy efficiency improvement and decrease of Radiation side effects with these techniques, Exact Radiation treatments are expected.

  • PDF

Experimental Study of the In-Water Radiation Impedance of the Finite Baffle Cylinder Radiator (유한 배플 원통 진동체의 수중 방사 임피던스에 대한 실험적 연구)

  • Kim, Won-Ho;Yoon, Jong-Rak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.23-29
    • /
    • 1994
  • In this paper, the measured in-water radiation impedance of cylindrical piezoelectric radiator with finite baffle is compared to the existing theoretical result of that with infinite baffle and the effect of baffle on the radiation impedance is examined. Comparision between measurement and theoretical result of radiation impedance shows that the measured radiation impedance tends to be that of the infinite baffle as the baffle length increases. Another finding of the comparision in that the effect of baffle is more dominant in radiation reactance than in radiation resistance. Therefore, for the use of theoretical radiation impedance of infinite baffle on the design of acoustic transducer, the impedance compensation to the baffle length should conducted.

  • PDF

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

Moderating effect of regulatory focus on public acceptance of nuclear energy

  • He, Yanling;Li, Yazhou;Xia, Dongqin;Zhang, Tingting;Wang, Yongliang;Hu, Li;Gu, Jibao;Wu, Yican
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.2034-2041
    • /
    • 2019
  • Public acceptance has become the most critical question for sustainable development of nuclear energy in recent decades. Many researches concentrated on risk and benefit perception, which were deemed as the most influential factors of Public Acceptance of Nuclear Energy (PANE). But few researches focused on psychological factors including regulatory focus. Therefore, this paper aimed to explore the moderating effect of regulatory focus on PANE based on Regulatory Focus Theory in order to find ways to increase/decrease PANE. An Internet-based survey had been carried out in China nationwide. The results indicated that trust in government was positively related to PANE and this relationship was mediated by risk and benefit perception. In addition, the strength of the associations between risk and benefit perception and PANE were moderated by regulatory focus, consisting of prevention focus and promotion focus. Prevention focus strengthened the negative relationship between risk perception and PANE, while promotion focus weakened. Moreover, promotion focus weakened the positive relationship between benefit perception and PANE, but no significant moderating effect of prevention focus was founded on the relationship between benefit perception and PANE. Some policy implications were also proposed on the basis of above-mentioned findings.

Particle capture by radiation drag around a highly luminous compact stars

  • Oh, Jae Sok;Park, Chan;Kim, Hongsu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.77.2-77.2
    • /
    • 2013
  • xIn the present work, we explored the effect of the radiation on the effective impact parameter for capture in a fully general relativistic manner. To summarize our results, evidently due to the radiation drag (the Poynting-Robertson effect), critical impact parameter of point particle gets larger by the factor of two, thus, the effective cross section of the luminous relativistic star becomes 4 times larger than that of the star without radiation emission. In addition, the finite size effect of the star adds up to this growth of the effective cross section.

  • PDF