• 제목/요약/키워드: Radiation dose

검색결과 4,964건 처리시간 0.032초

THE FACTORS WHICH AFFECT THE EXTERNAL RADIATION DOSE RATE OF PET-CT PATIENTS

  • Cho, Ihn Ho;Kim, Su Jin;Han, Eun Ok
    • Journal of Radiation Protection and Research
    • /
    • 제37권4호
    • /
    • pp.231-236
    • /
    • 2012
  • This study derived measures to reduce exposure doses by identifying factors which affect the external radiation dose rate of patients treated with radiopharmaceuticals for PET-CT tests. The external radiation dose rates were measured on three parts of head, thorax and abdomen at a distance of 50cm from the surface of 60 PET-CT patients. It showed there are changes in factors affecting the external radiation dose rate over time after the administration of F-18 FDG. The external radiation dose rate was lower in the patients with more water intake than those with less water intake before the injection of radiopharmaceuticals at all three points: right after the injection of radiopharmaceuticals (average 4.17 mins), after the pre-PEET-CT urination step (average 77.47 mins), and right after the PET-CT test (average 114.15 mins). The study also found there is a need to increase the amount of water intake before the injection of radiopharmaceuticals in order to maintain a low external radiation dose rate in patients. This strategy is only possible under the assumption that the quality of the video has not changed after conducting this study on the relations between the image and quality. This study also found a need to use radiopharmaceuticals with the minimum amount needed for each patient because F-FDG doses affects the external radiation dose rate at the point right after the injection of radiopharmaceuticals. Urination frequency was the most significant factor to affect the external radiation dose rates at the point right after the PET-CT test and the point after the pre-PET-CT urination step. There is a need to realize the strategy to increase the urination frequency of patients to maintain the external radiation dose rate low (average 77.47 mins) before and after the injection of radiopharmaceuticals. In addition, at this point, there is a need to take advantage of personal strategies because the external radiation dose rate is lower if the fasting time is shorter, the contrast medium is used, and the amount of water intake is increased after the administration of radiopharmaceuticals. Finally this study found the need to be able to generalize these findings through an in-depth research on the factors affecting the external radiation dose rate, which includes radiopharmaceutical dose, urination frequency, the amount of water intake, fasting time and the use of contrast medium.

콘크리트 공동주택과 근린생활 시설의 환경방사선에 관한 연구 (A Study on the Environmental Radiation of Concrete Apartments and Neighborhood Living Facilities)

  • 지태정;곽병준;민병인
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.100-104
    • /
    • 2009
  • In this study, the space gamma dose rates in the apartments structured with concrete were measured in accordance with construction year. In addition, the environmental radiation rates coming from the subway platforms and the road tunnels were analyzed in the equivalent dose by multiplying the absorbed dose with the radiation weighting factors. The space gamma dose rates measured in apartments were higher than those of outdoor which was $0.08{\sim}0.11uSv/h$ in the natural conditions. Especially, the older construction year is, the higher becomes space gamma dose rate. The average gamma dose rates in the subway platforms were measured. In the case of Busan and Daegu subway, the earlier the opening year is, the higher becomes dose rate. However, the dose rates of Seoul subway Lines were high overall, regardless of opening year. Seoul subway Line 6 showed the highest value of 0.21uSv/h. The gamma dose rate in road tunnels was higher than one of the outdoor and increased with opening year like as apartment. In dose rate comparison of the concrete structures with the outdoor, therefore, the space gamma dose rate of indoor is higher than one of the outdoor and the older structures have a higher dose rate.

자궁경부암 강내 방사선 조사장치에 의한 직장 및 방광의 피폭선량 평가 (Dose Distribution of Rectum and Bladder in Intracavitary Irradiation)

  • 추성실;오원용;서창옥;김귀언
    • Radiation Oncology Journal
    • /
    • 제2권2호
    • /
    • pp.261-270
    • /
    • 1984
  • The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The simulation radiation and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct. 1983, were critically analized. The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system. The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer. Followings were summary of study results ; 1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as $4\~7cm$ width and high dose rate system showed as $5\~6cm$. 2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position$64.6\%$, left deviation $19.2\%$and right deviation $16.2\%$. 3. In longitudinal angulation of tandem to body axis, the mid position was $11.8\%$ and anterior angulation $88.2\%$ in low dose rate system but in high dose rate system, anterior angulation was $98.5\%$. 4. Down ward displacement of ovoids below external os was only $3\%$ in low dose rate system and $66.7\%$ in high dose rate system. 5. In radiation source arrangement, the most activities of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system. 6. In low and high dose rate system, the total doses an4 TDF were 50, 70 Gy and 141, 123, including 40 Gy external irradiation. 7. The doses and TDF in interesting points Co, B, were 93, 47 Gy and 230, 73 in high dose rate system but in low doss rate system, 123, 52 Gy and 262, 75 respectively. 8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, $30\%$ and 18, $23\%$ respectively.

  • PDF

Development and evaluation of modified lead gloves to reduce hand radiation dose during interventional radiological procedures

  • Hyun-Jun Park;Byungdu Jo;Seung-Jae Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2781-2789
    • /
    • 2024
  • We developed lead gloves that minimize radiation dose to the operator's hands during interventional radiological procedures and that do not impede the operator's surgical capabilities. Existing lead gloves can protect the operator's hands by shielding radiation, but use of such gloves may impair preception sensitivity, resulting in a reduction in the operator's surgical ability. Accordingly, in this study, we developed modified lead gloves that can reduce radiation dose while maintaining operator sensitivity during procedures by modifying the operator's main surgical finger area in existing lead gloves. To evaluate the performance of developed modified lead gloves, radiation was applied in surgical conditions without gloves and with surgical gloves, lead gloves, and modified lead gloves. The radiation dose was evaluated for each condition. When the modified lead gloves were worn, the degree of shielding was similar to when conventional lead gloves were worn. Based on these results, if the operator wears modified lead gloves during interventional radiological procedures, they will protect the hands from radiation while maintaining physical sensitivity in the hands.

THE SHORT-TERM EFFECTS OF LOW-DOSE-RATE RADIATION ON EL4 LYMPHOMA CELL

  • Bong, Jin-Jong;Kang, Yu-Mi;Shin, Suk-Chul;Choi, Moo-Hyun;Choi, Seung-Jin;Lee, Kyung-Mi;Kim, Hee-Sun
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.56-62
    • /
    • 2012
  • To determine the biological effects of low-dose-rate radiation ($^{137}Cs$, 2.95 mGy/h) on EL4 lymphoma cells during 24 h, we investigated the expression of genes related to apoptosis, cell cycle arrest, DNA repair, iron transport, and ribonucleotide reductase. EL4 cells were continuously exposed to low-dose-rate radiation (total dose: 70.8 mGy) for 24 h. We analyzed cell proliferation and apoptosis by trypan blue exclusion and flow cytometry, gene expression by real-time PCR, and protein levels with the apoptosis ELISA kit. Apoptosis increased in the Low-dose-rate irradiated cells, but cell number did not differ between non- (Non-IR) and Low-dose-rate irradiated (LDR-IR) cells. In concordance with apoptotic rate, the transcriptional activity of ATM, p53, p21, and Parp was upregulated in the LDR-IR cells. Similarly, Phospho-p53 (Ser15), cleaved caspase 3 (Asp175), and cleaved Parp (Asp214) expression was upregulated in the LDR-IR cells. No difference was observed in the mRNA expression of DNA repair-related genes (Msh2, Msh3, Wrn, Lig4, Neil3, ERCC8, and ERCC6) between Non-IR and LDR-IR cells. Interestingly, the mRNA of Trfc was upregulated in the LDR-IR cells. Therefore, we suggest that short-term Low-dose-rate radiation activates apoptosis in EL4 lymphoma cells.

Evaluating the Effects of Dose Rate on Dynamic Intensity-Modulated Radiation Therapy Quality Assurance

  • Kim, Kwon Hee;Back, Tae Seong;Chung, Eun Ji;Suh, Tae Suk;Sung, Wonmo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.116-121
    • /
    • 2021
  • Purpose: To investigate the effects of dose rate on intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods: We performed gamma tests using portal dose image prediction and log files of a multileaf collimator. Thirty treatment plans were randomly selected for the IMRT QA plan, and three verification plans for each treatment plan were generated with different dose rates (200, 400, and 600 monitor units [MU]/min). These verification plans were delivered to an electronic portal imager attached to a Varian medical linear accelerator, which recorded and compared with the planned dose. Root-mean-square (RMS) error values of the log files were also compared. Results: With an increase in dose rate, the 2%/2-mm gamma passing rate decreased from 90.9% to 85.5%, indicating that a higher dose rate was associated with lower radiation delivery accuracy. Accordingly, the average RMS error value increased from 0.0170 to 0.0381 cm as dose rate increased. In contrast, the radiation delivery time reduced from 3.83 to 1.49 minutes as the dose rate increased from 200 to 600 MU/min. Conclusions: Our results indicated that radiation delivery accuracy was lower at higher dose rates; however, the accuracy was still clinically acceptable at dose rates of up to 600 MU/min.

엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성 (Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray)

  • 권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권5호
    • /
    • pp.256-263
    • /
    • 2017
  • By using the buildup characteristics of the radiophotoluminescence glass dosimeter(RPLGD), it is aimed to help the measurement of the accurate dose by measuring the radiation dose according to the time of the glass element. Five glass elements were arranged on the table and the source to image receptor distance(SID) was set to 100 cm for the build-up radiation dose measurement of the fluorescent glass dosimeter glass element(GD-352M). Radiation doses and saturation rates were measured over time according to irradiation time, with the tube voltage (30, 60, 90 kVp) and tube current (50, 100 mAs) Repeatability test was repeated ten times to measure the coefficient of variation. The radiation dose increased from 0.182 mGy to 12.902 mGy and the saturation rate increased from 58.3% with increasing exposure condition and time. The coefficient of variation of the glass elements of the fluorescent glass dosimeter was ranged from 0.2 to 0.77 according to the X - ray exposure conditions. X - ray exposure showed that the radiation dose and saturation rate were increased with buildup characteristics, and degeneration of glass elements was not observed. The reproducibility of the variation coefficient of the radiation generator was included within the error range and the reproducibility of the radiation dose was excellent.

Radiation Exposure Dose of Handlers Using 18F-FDG in Small Animal Image Acquisition Experiments

  • Ik Soo Kim;Sun Young Yoon;Hwa Yeon Yeo
    • 방사선산업학회지
    • /
    • 제17권3호
    • /
    • pp.233-238
    • /
    • 2023
  • This study was conducted to confirm the safety of the operator's radiation exposure in the micro PET-CT image acquisition experiment using the 18F-FDG. The usage of 18F-FDG and the exposure dose of handlers were measured at University B in Metropolitan City A, which uses 18F-FDG for micro PET-CT image acquisition. As a result of the measurement, the exposure dose is far below the effective dose limit of radiation workers, 50 mSv per year, and the equivalent dose limit of 500 mSv per year for hands, feet, and skin. has been measured Since these exposure doses can be further increased according to the number of times of use of 18F-FDG, it is judged that the exposure dose compared to the handling amount of 18F-FDG shown in this study can be used as reference data. In addition, as changed environments such as the use of materials other than unopened RI are occurring in education and research environments, such as the use of 18F-FDG at University B, radiation exposure with more interest in safety management by checking the factors of radiation exposure of the handler concerned We will always do our best to reduce it.

Low-Dose Radiation Stimulates the Proliferation of Normal Human Lung Fibroblasts Via a Transient Activation of Raf and Akt

  • Kim, Cha Soon;Kim, Jin Kyoung;Nam, Seon Young;Yang, Kwang Hee;Jeong, Meeseon;Kim, Hee Sun;Kim, Chong Soon;Jin, Young-Woo;Kim, Joon
    • Molecules and Cells
    • /
    • 제24권3호
    • /
    • pp.424-430
    • /
    • 2007
  • The biological effects of low-dose radiation have been investigated and debated for more than a century, but its cellular effects and regulatory mechanisms remain poorly understood. This study shows the human cellular responses to low-dose radiation in CCD-18 Lu cells, which are derived from normal human lung fibroblasts. We examined a colony-forming assay for cell survival by ionizing radiation. Live cell counting and cell cycle analysis were measured for cell proliferation and cell cycle progression following low-dose irradiation. We examined Raf and Akt phosphorylation to determine the proliferation mechanism resulting from low-dose radiation. We also observed that p53 and p21 were related to cell cycle response. We found that 0.05 Gy of ionizing radiation enhanced cell proliferation and did not change the progression of the cell cycle. In addition, 0.05 Gy of ionizing radiation transiently activated Raf and Akt, but did not change phospho-p53, p53 and p21 in CCD-18 Lu cells. However, 2 Gy of ionizing radiation induced cell cycle arrest, phosphorylation of p53, and expression of p53 and p21. The phosphorylation of Raf and Akt proteins induced by 0.05 Gy of ionizing radiation was abolished by pre-treatment with an EGFR inhibitor, AG1478, or a PI3k inhibitor, LY294002. Cell proliferation stimulated by 0.05 Gy of ionizing radiation was blocked by the suppression of Raf and Akt phosphorylation with these inhibitors. These results suggest that 0.05 Gy of ionizing radiation stimulates cell proliferation through the transient activation of Raf and Akt in CCD-18 Lu cells.