• 제목/요약/키워드: Radiation degradation

검색결과 289건 처리시간 0.028초

Synthesis and Characterization of CdSe/graphene Nanocomposites and their Catalytic Reusability Studies under Visible Light Radiation

  • Ali, Asghar;Oh, Won-Chun
    • 한국세라믹학회지
    • /
    • 제52권6호
    • /
    • pp.502-507
    • /
    • 2015
  • We examined the photo catalytic activity and catalytic recyclability of CdSe/graphene nanocomposites fabricated via modified hydrothermal technique. The prepared composites were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) with energy dispersive X-ray (EDX), transmission electron microscopy (TEM), Raman spectroscopic analysis, and X-ray photoelectron spectroscopy (XPS). The photocatalytic behavior was investigated through decomposition of RBB as a standard dye under visible light radiation. Our results indicate that there is significant potential for graphene based semiconductor hybrids materials to be used as photocatalysts under visible light irradiation for the degradation of organic dyes from industry effluents.

Design of Microstrip Array Antenna with Three-Element Sequential-Rotation Subarray for DBS

  • Jin, Kyung-Soo;Shin, Hye-Jung;Park, Byong-Woo
    • Journal of electromagnetic engineering and science
    • /
    • 제2권1호
    • /
    • pp.28-33
    • /
    • 2002
  • The LHCP circularly polarized antenna operating at DBS band is developed by employing the sequential-rotation technique in which each subarray is comprised the three truncated-corner patch square element. Antenna designed with sequentially-related technique whose M=3, p=2 has the effect of improved axial-ratio bandwidth, cross-polarization etc. And it is proved that the degradation of radiation pattern can be reduced significantly by minimizing the radiation loss of feeding line structure. Antenna designed shows extremely low side lobe level of below - 25 dB in the diagonal plane and cross-polarization level of below -20 dB in the all plane. And these performances comply with the array antenna specification for DBS.

Even Harmonic Mixer를 이용한 2.4GHz ISM band용 Direct Conversion방식의 RF Module 설계 및 제작 (Design and Fabrication of Direct Conversion RF Module using Even Harmonic Mixer for 2-4GHz ISM band)

  • 이주갑;윤영섭;최현철
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2001년도 종합학술발표회 논문집 Vol.11 No.1
    • /
    • pp.222-226
    • /
    • 2001
  • In this paper, 2.4GHz RF Module using Even Harmonic Mixer(EHM) was designed and fabricated for Direct conversion(DC) system. By minimizing performance degradation of DC system with DC offset and LO radiation, the capability of minimization and one chip solution in wireless system was proposed. The designed EHM using anti-parallel diode pair represented 9dB conversion loss and about -60dBm 2LO leakage radiation in RF port, and output reflection and reverse transmission characteristic of low noise amplifier was improved. So superior DC offset suppression characteristic is expected. RF Module which consists of EHM, LNA, RF amplifier, Frequency synthesizer and Duplexer was designed and fabricated.

  • PDF

Comparison of tdcA Expression Between Escherichia coli and Salmonella enterica Serovar Typhimurium

  • Kim, Min-Jeong;Lim, Sang-Yong;Ryu, Sang-Ryeol
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권3호
    • /
    • pp.252-255
    • /
    • 2011
  • Both Escherichia coli (E. coli) and Salmonella enterica serovar Typhimurium (S. Typhimurium) have a tdc operon that encodes enzymes involved in a metabolic pathway for the degradation of L-serine and L-threonine. However, S. Typhimurium does not have the tdcR gene, which is a positive regulator in E. coli. In the present study, transcriptional analysis revealed that tdcA expression in E. coli is higher under anaerobic than aerobic growth conditions, but the opposite is true in S. Typhimurium. Interestingly, a tdcR mutant strain of E. coli showed a similar expression pattern to that observed in S. Typhimurium and was also induced by anaerobic shock. These results suggest that the induction of tdcA expression by anaerobic conditions is observable when tdcA expression is low owing to the absence of TdcR.

자외선 노출에 따른 폴리머애자 하우징의 열화특성평가 (Aging Evaluation of Polymer Insulator Housing with UV Exposure)

  • 이병성;한재홍;김찬영;한용희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.214-217
    • /
    • 1999
  • Polymeric composite insulators have been in use for outdoor insulation. However, our knowledge about their long-term performance in a outdoor environment is still very limited. Especially, these insulator are subjected to the environmental stress such as ultraviolet radiation. Hence, in this paper. the influence of UV radiation on the aging of the shed materials was evaluated. For the aging evaluation, these insulators studied by experiment methods such as contact angle measurement. oxidation induced time. SEM/EDX, FTRI-ATR, tracking test for the different insulator samples. With the increased UV exposure time, samples are shown to exhibit degradation comparable to those of new ones

  • PDF

열화에 따른 Polyetheretherketone의 유전완화특성 (Dielectric Relaxation Properties for following the Ageing of Polyetheretherketone)

  • 김기엽;이청;류부형;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.396-403
    • /
    • 2004
  • The dielectric properties of Y-ray irradiated and thermally aged polyetheretherketone (PEEK) have been investigated. Results of the temperature dependency of dielectric properties indicated that the glass transition temperature of aged PEEK increased as radiative and thermal ageing. The frequency dependency of dielectric properties implied that the magnitude of radiation and thermal induced dipoles, ions increased as radiative and thermal ageing. The values of relaxation intensity calculated using Cole-Cole's circular arc can be useful for evaluation of degradation level of PEEK.

방사선 조사에 따른 저밀도 폴리에틸렌의 유전특성에 관한 연구 (A study on dielectric characteristics of gamma irradiated LDPE)

  • 김기엽;이청;임기조;류부형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 2000
  • In this paper, we evaluated the mechanical and dielectric properties of LDPE depend on $Co_{60}$${\gamma}$-irradiation doses. The chemical analyses for FT-IR, gel content, the mechanical properties for elongation at break and the dielectric parameters for permittivity, tan$\delta$ were discussed as a function of irradiation doses. Test result presented that elongation at break of irradiated LDPE was inversely proportional to gel content. For dielectric analyses, permittivity showed a salient characteristic for various irradiation doses, it was related to polar groups caused radiation degradation and tan$\delta$ of irradiated LDPE increased with irradiation doses.

  • PDF

Modeling and characterization of beryllium reflector elements under irradiation conditions

  • Ahmed H. Elhefnawy;Mohamed A. Gaheen;Hanaa H. Abou Gabal;Mohamed E. Nagy
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4583-4590
    • /
    • 2023
  • This study aims at modeling the beryllium reflector poisoning under neutron irradiation conditions and calculating the impact of beryllium poisoning on the core parameters of ETRR-2 research reactor. The CITVAP code was used to calculate the neutron flux and parameters of ETRR-2 core with beryllium reflector elements. The neutron flux in each reflector element was calculated to solve the modeling equations for the atomic densities of lithium-6 (6Li), tritium-3 (3H), and helium-3 (3He) using the BERYL program. The results are discussed based on CITVAP calculations of the core excess reactivity and cycle length Full Power Days (FPD). Possible solutions to minimize the degradation due to beryllium poisoning are also discussed and compared based on calculations.

Non-iterative pulse tail extrapolation algorithms for correcting nuclear pulse pile-up

  • Mohammad-Reza Mohammadian-Behbahani
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4350-4356
    • /
    • 2023
  • Radiation detection systems working at high count rates suffer from the overlapping of their output electric pulses, known as pulse pile-up phenomenon, resulting in spectrum distortion and degradation of the energy resolution. Pulse tail extrapolation is a pile-up correction method which tries to restore the shifted baseline of a piled-up pulse by extrapolating the overlapped part of its preceding pulse. This needs a mathematical model which is almost always nonlinear, fitted usually by a nonlinear least squares (NLS) technique. NLS is an iterative, potentially time-consuming method. The main idea of the present study is to replace the NLS technique by an integration-based non-iterative method (NIM) for pulse tail extrapolation by an exponential model. The idea of linear extrapolation, as another non-iterative method, is also investigated. Analysis of experimental data of a NaI(Tl) radiation detector shows that the proposed non-iterative method is able to provide a corrected spectrum quite similar with the NLS method, with a dramatically reduced computation time and complexity of the algorithm. The linear extrapolation approach suffers from a poor energy resolution and throughput rate in comparison with NIM and NLS techniques, but provides the shortest computation time.

Head & Neck 환자의 방사선 치료시 Metal Artifact의 감소를 위한 Gantry Tilt Scan의 유용성 평가 (Evaluation of using Gantry Tilt Scan to Head & Neck of Patients during Radiation Therapy for Reduction of Metal Artifact)

  • 이충환;윤인하;홍동기;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.85-95
    • /
    • 2010
  • 목 적: 두경부 환자의 CT simulation시 metal artifact가 발생하여 영상의 질 저하와 선량계산의 오차를 유발 할 수 있어 metal artifact를 줄이기 위한 gantry tilt scan의 유용성을 평가하고자 한다. 대상 및 방법: Metal artifact를 줄이기 위하여 $20^{\circ}$ gantry tilt scan하여 $0^{\circ}$로 재구성한 이미지를 획득하였다. AAPM CT performance Phantom을 이용하여 CT number를 비교 분석하고, 아크릴 팬텀을 이용하여 체적의 일치여부를 확인하였다. Metal artifact에 의한 영향을 평가하기 위해 Intensity volume Histogram (IVH)을 통한 CT number의 균질성 및 Dose Volume histogram (DVH)을 통한 선량평가를 시행하였다. 결 과: CT number와 체적의 비교에서는 차이가 0.5% 이하로 나타났다. IVH를 비교 분석결과 gantry tilt scan에서 artifact에 의한 영향이 감소되어 CT number의 균질도가 향상되고, DVH 비교결과는 양쪽 이하선의 0.2~6%의 평균선량 오차를 감소시켰다. 결 론: Head & Neck 방사선치료 시 metal artifact 때문에 체표윤곽의 구별이 어렵고 선량의 오차가 발생한다. Gantry tilt scan을 이용하면 정확한 조직의 묘사가 가능하고, CT number 균질도가 향상되어 선량의 오차를 줄일 수 있었다. Gantry tilt scan 은 Head & Neck 방사선치료 시 정확한 방사선치료에 매우 유용함을 확인하였다.

  • PDF