• Title/Summary/Keyword: Radiation and Scattering

Search Result 383, Processing Time 0.023 seconds

A study on radiation safety education, knowledge, and practice in using portable intraoral X-ray equipment of dental hygienist's (치과위생사의 이동형 구내방사선 촬영에 관한 방사선 방어 교육, 지식, 수행에 관한 연구)

  • Ryu, Jeong-Min;Kang, Bo-Sun;Kim, Seol-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.6
    • /
    • pp.1053-1065
    • /
    • 2017
  • Objectives: The purpose of this study is to evaluate radiation safety education, knowledge and practice of dental hygienists in using handheld portable intraoral X-ray equipment and to suggest the need for radiation safety education in using handheld portable intraoral X-ray equipment. Methods: We surveyed 223 dental hygienists from July, 2017 to August in the dental clinics of Daejeon, Seoul and Gyeonggi area. Results: Radiation safety educational experience was higher in a year's career (72.9%), than 3 years experience (32.5%) (p<0.05). 82.7% of dental clinic workers took university education for radiation safety education while 55.6% of dental hospital workers took company training (p<0.05). More than 70% of the subjects did not have experience of radiation safety education about using portable intraoral X-ray. Radiation safety knowledge was highest in a year's career (p<0.05). The cumulative dose, radiation sensitivity, and lead defense knowledge were high in all subjects, but knowledge related to scattering radiation and scattering radiation sources was low. Practice of portable intraoral X-ray safety was significantly lower than knowledge. Conclusions: Knowledge of portable intraoral radiography safety is available, but performance is poor. Even with the small amount of radiation exposure, the risk is perceivable. There is a need to actively utilize the provided radiation protection products. In order to do this, efforts should be made to improve knowledge and performance of radiation safety through not only college education but also postemployment training.

Preliminary Study of Performance Evaluation of a Dual-mode Compton Camera by Using Geant4 (Geant4 몬테칼로 전산모사 툴킷을 이용한 이중모드 컴프턴 카메라 최적화 설계 및 성능평가)

  • Park, Jin Hyung;Seo, Hee;Kim, Seoung Hoon;Kim, Young Soo;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.191-196
    • /
    • 2012
  • A double-scattering type Compton camera which is appropriate to imaging a high-energy gamma source has been developed for nuclear material surveillance at Hanyang University. The double-scattering type Compton camera can provide high imaging resolution; however, it has disadvantage of relatively low imaging sensitivity than existing single-scattering type Compton camera. In this study, we introduce a novel concept of a dual-mode Compton camera which incorporates two different types of Compton camera, i.e., single- and double-scattering type. The dual-mode Compton camera can operate high-resolution mode and high-sensitivity mode in a single system. To maximize its performance, the geometrical configuration was optimized by using Geant4 Monte Carlo simulation toolkit. In terms of imaging sensitivity, high-sensitivity mode had higher sensitivity than high-resolution mode up to 100 times while high imaging resolution of the double-scattering Compton camera was maintained.

Scattering characteristics of metal and dielectric optical nano-antennas

  • Ee, Ho-Seok;Lee, Eun-Khwang;Song, Jung-Hwan;Kim, Jinhyung;Seo, Min-Kyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.76.1-76.1
    • /
    • 2015
  • Optical resonances of metallic or dielectric nanoantennas enable to effectively convert free-propagating electromagnetic waves to localized electromagnetic fields and vice versa. Plasmonic resonances of metal nanoantennas extremely modify the local density of optical states beyond the optical diffraction limit and thus facilitate highly-efficient light-emitting, nonlinear signal conversion, photovoltaics, and optical trapping. The leaky-mode resonances, or termed Mie resonances, allow dielectric nanoantennas to have a compact size even less than the wavelength scale. The dielectric nanoantennas exhibiting low optical losses and supporting both electric and magnetic resonances provide an alternative to their metallic counterparts. To extend the utility of metal and dielectric nanoantennas in further applications, e.g. metasurfaces and metamaterials, it is required to understand and engineer their scattering characteristics. At first, we characterize resonant plasmonic antenna radiations of a single-crystalline Ag nanowire over a wide spectral range from visible to near infrared regions. Dark-field optical microscope and direct far-field scanning measurements successfully identify the FP resonances and mode matching conditions of the antenna radiation, and reveal the mutual relation between the SPP dispersion and the far-field antenna radiation. Secondly, we perform a systematical study on resonant scattering properties of high-refractive-index dielectric nanoantennas. In this research, we examined Si nanoblock and electron-beam induced deposition (EBID) carbonaceous nanorod structures. Scattering spectra of the transverse-electric (TE) and transverse-magnetic (TM) leaky-mode resonances are measured by dark-field microscope spectroscopy. The leaky-mode resonances result a large scattering cross section approaching the theoretical single-channel scattering limit, and their wide tuning ranges enable vivid structural color generation over the full visible spectrum range from blue to green, yellow, and red. In particular, the lowest-order TM01 mode overcomes the diffraction limit. The finite-difference time-domain method and modal dispersion model successfully reproduce the experimental results.

  • PDF

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

Collimator Design and Manufacture for $M{\ddot{o}}ssbauer$ Source ($M{\ddot{o}}ssbauer$ 선원용 콜리메이터 설계 및 제작)

  • Park, Sung-Ho;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.183-187
    • /
    • 2003
  • Collimator for $M{\ddot{o}}ssbauer$ source was manufactured for compton scattering experiment. Exposure dose rate was calculated and measured using GM counter for radiation evaluation. These results were well agreed to each other and used for collimator design. SUS303 was used for collimator material because exposure dose rate at 10 cm is about 2 mR/h. The radiation emited from the 35 mm, 65 mm hole was measured using gamma camera which have 4' diameter. 2-D radiation image was acquired and analyzed. The radiation size at Gamma Camera was 8.0 mm and 5.8 mm respectively.

Numerical study of a coating with pigment to selectively reflect the thermal radiation from fire (화염 열복사의 파장별 선택적 반사를 위한 도료 코팅에 대한 수치적 연구)

  • Byeon, Do-Yeong;Baek, Seung-Uk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.399-407
    • /
    • 1998
  • The infrared reflection coatings with pigment can be used to protect the surfaces of combustible materials exposed to fire. To obtain high reflectivities in the infrared range (0.5-10.mu.m) important to fire, several dielectric pigments, such as titanium dioxide, iron oxide, and silicon, can be synthesized to polymer coatings. The theoretical analysis shows that the coating design with particles diameter in the 1.5 to 2.5.mu.m range and volume fraction in the 0.1 to 0.2 range is estimated to be optimal. In the analysis of the radiation, the dependent scattering, absorption by polymeric binder, and the internal interface reflection are considered. In addition, the temperature distribution in the semi-transparent coating layer and an opaque substrate (PMMA) is also presented.

STaRS Gen 2: Sejong Radiative Transfer through Raman and Rayleigh Scattering in Dusty Medium

  • Chang, Seok-Jun;Lee, Hee-Won;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.81.2-81.2
    • /
    • 2021
  • Emission features formed through Raman scattering with atomic hydrogen provide unique and crucial information to probe the distribution and kinematics of a thick neutral region illuminated by a strong far-ultraviolet radiation source. We introduce a new 3-dimensional Monte-Carlo code to describe the radiative transfer of line photons subject to Raman and Rayleigh scattering with atomic hydrogen. In our Sejong Radiative Transfer through Raman and Rayleigh Scattering (STaRS) code, the position, direction, wavelength, and polarization of each photon is traced until escape. The thick neutral scattering region is divided into multiple cells. Each cell is characterized by its velocity and density, which ensures flexibility of the code in analyzing Raman-scattered features formed in a neutral region with complicated kinematics and density distribution. We are continuously developing STaRS to adopt the absorption and scattering effect by dust. This presentation introduces STaRS and its current state and study.

  • PDF

Dielectric Cylinder Optical Amplifier (원통형 유전체 광 증폭기에 대한 연구)

  • 이성수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.146-147
    • /
    • 2000
  • The electromagnetic wave scattering from active objects has only recently attracted attention.$^{(1).(3)}$ Theoretical studies have considered normal-incidence plane-wave interactions with active dielectric cylinders with the prediction of large enhancements in the scattered field for bound mode structures. According to the theory of the electromagnetic wave scattering from a dielectric cylinder, the eigenvector solutions are discrete and have both guided (non-radiative) and leaky (radiative) mode solutions. By using an anti-guiding (leaky) structure instead of a guided structure and scattering at oblique incident angles near critical angle, the scattering resonances predicted by theoretical studies were obtained for the first time. A fine-grained scan of the plane-wave incident angle a reveals the existence of discrete scattering resonances. The diameter and real part of the index of refraction determine the resonant conditions and the imaginary part of the refractive index has a threshold value to make mode up for its radiation loss. The cross coupling between transverse electric (TE) and transverse magnetic (TM) modes is clearly detected for both active and passive scattering as theoretically expected. (omitted)

  • PDF

MATRIX ELEMENTS AND CROSS SECTION OF RAMAN SCATTERING BY ATOMIC HYDROGEN

  • Lee, Hee-Won
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.1
    • /
    • pp.21-33
    • /
    • 2007
  • Ever since the identification of 6830 and 7088 features as the Raman scattered O VI 1032, 1038 resonance doublets in symbiotic stars by Schmid (1989), Raman scattering by atomic hydrogen has been a very unique tool to investigate the mass transfer processes in symbiotic stars. Discovery of Raman scattered He II in young planetary nebulae (NGC 7027, NGC 6302, IC 5117) allow one to expect that Raman scattering can be an extremely useful tool to look into the mass loss processes in these objects. Because hydrogen is a single electron atom, their wavefunctions are known in closed form, so that exact calculations of cross sections are feasible. In this paper, I review some basic properties of Raman scattered features and present detailed and explicit matrix elements for computation of the scattering cross section of radiation with atomic hydrogen. Some astrophysical objects for which Raman scattering may be observationally pertinent are briefly mentioned.

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.