• Title/Summary/Keyword: Radiation Usage

Search Result 106, Processing Time 0.029 seconds

Development and Application of Training Program for RI-Biomics Manpower through Analysis of Educational Demands (교육수요 분석을 통한 RI-Biomics 전문인력 양성 프로그램 개발 및 적용)

  • Shin, Woo-Ho;Park, Tai-Jin;Yeom, Yu-Sun
    • Journal of The Korean Association For Science Education
    • /
    • v.35 no.1
    • /
    • pp.159-167
    • /
    • 2015
  • RI-Biomics is a promising radiation convergence technology that combines radiation with bio science as new growth power technology. Many developed countries are focusing active support and constant exertion to dominate the RI-Biomics market in advance. In order to achieve global leadership in the RI-Biomics field, we need more highly advanced technologies and professional manpower. In fact, we have less manpower compared to technology we currently hold. In this study, we established a basic infrastructure to train professional manpower in the RI-Biomics field by developing/operating optimum training program through expert interviews and survey. The developed program has four organized sections to understand overall procedure of RI-Biomics. To evaluate our training program, we performed test operations with eight students who have a major related to RI-Biomics for three weeks in KARA (Seoul) and KAERI (Jung-eup). In detail, radioisotope usage and safety management were conducted for one week as basic course, RI-Biomics application technology was conducted for two weeks as professional course. To verify performance results of training program, we conducted to journal research, daily reports, and survey on participants. The results show a high level of satisfaction with training programs and continuous intention of involvement in our program. We also need to develop an intensive course to train high-quality human resources and to operate training program continuously. This training program will be used as basic materials for the development of RI-Biomics curriculum for university. Hence, we will expect that our training program contributes in training a professional manpower and develop RI-Biomics technology.

Development of the Monte Carlo Simulation Radiation Dose Assessment Procedure for NORM added Consumer Adhere·Non-Adhere Product based on ICRP 103 (ICRP 103 권고기반의 밀착형·비밀착형 가공제품 사용으로 인한 몬테칼로 전산모사 피폭선량 평가체계 개발)

  • Go, Ho-Jung;Noh, Siwan;Lee, Jae-Ho;Yeom, Yeon-Soo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Radiation exposure to humans can be caused by the gamma rays emitted from natural radioactive elements(such as uranium, thorium and potassium and any of their decay products) of Naturally Occurring Radioactive Materials(NORM) or Technologically Enhanced Naturally Occurring Radioactive Materials(TENORM) added consumer products. In this study, assume that activity of radioactive elements is $^{238}U$, $^{235}U$, $^{232}Th$ $1Bq{\cdot}g^{-1}$, $^{40}K$ $10Bq{\cdot}g^{-1}$ and the gamma rays emitted from these natural radioactive elements radioactive equilibrium state. In this study, reflected End-User circumstances and evaluated annual exposure dose for products based on ICRP reference voxel phantoms and ICRP Recommendation 103 using the Monte Carlo Method. The consumer products classified according to the adhere to the skin(bracelet, necklace, belt-wrist, belt-ankle, belt-knee, moxa stone) or not(gypsum board, anion wallpaper, anion paint), and Geometric Modeling was reflected in Republic of Korea "Residential Living Trend-distributions and Design Guidelines For Common Types of Household.", was designed the Room model($3m{\times}4m{\times}2.8m$, a closed room, conservatively) and the ICRP reference phantom's 3D segmentation and modeling. The end-user's usage time assume that "Development and Application of Korean Exposure Factors." or conservatively 24 hours; in case of unknown. In this study, the results of the effective dose were 0.00003 ~ 0.47636 mSv per year and were confirmed the meaning of necessary for geometric modeling to ICRP reference phantoms through the equivalent dose rate of belt products.

Analysis of the Entrance Surface Dose (ESD) and Contrast Usage of Trance Femoral Cerebral Angiography (TFCA) and Cerebral Computed Tomographic Angiography (CCTA) for Cerebrovascular Disease Examining (뇌혈관 질환 검사를 위한 뇌혈관 조영술(TFCA)과 뇌혈관 전산화 단층 촬영 검사(CCTA)의 입사표면선량(ESD) 및 조영제 사용량 분석)

  • Seo, Young-Hyun;Hong, Cheon-Gi;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.495-502
    • /
    • 2019
  • A typical cerebrovascular disease among cerebrovascular diseases is vascular diseases such as cerebral infarction, cerebral hemorrhage, cerebral aneurysm, cerebrovascular stenosis. If the disease occurs and causes cerebral damage, it may be difficult to recover completely. So that, Must continue to perform health care through examination early. In particular, Because most cerebrovascular disease examining use radiation equipment and Thus this study was to find out how to select about the optimal examining method and X-ray dose decrease method among different examining method though comparison and analysis for the entrance surface dose (ESD) on cerebrovascular examining with Trance Femoral Cerebral angiography (TFCA) and Cerebral Computed Tomographic Angiography (CCTA). Also, want to find out how to select about the optimal examining method for worried patient that contrast medium side effect though measuring and evaluating for contrast usage. Data were collected from 70 patients (43 males and 27 females) who underwent CCTA at Yeosoo region hospital from June 2018 to December 2018 and 61 patients (34 males and 27 females) who underwent TFCA at Pyeongtaek region hospital from June 2018 to November 2018. ESD analysis method collected retrospective data though M-view and PACS PLUS program, Used contrast usage measuring method did reality measuring method. In the analysis using SPSS, the ESD of TFCA was $245.74{\pm}71.91$, which was $32.05{\pm}7.74$ lower than the dose of $277.79{\pm}79.65$ of CCTA ESD, and statistically significant at t = 3.249, p = 0.017 (p<0.05). As a result of the comparison of the total amount of contrast agent, the mean contrast agent used in TFCA was $55.05{\pm}17.68ml$, which was about 14.95 smaller than the amount of contrast agent used in CCTA, and statistically significant t = -4.548, p<0.001. In conclusion, the ESD of TFCA was statistically significantly lower than that of CCTA, and also the used contrast usage was significantly tiny than that of CCTA. Therefore, Select the method to increase the utilization of TFCA for cerebral disease examining, we can consider X-ray dose decrease method at the same time as to decrease side effect of contrast medium.

Radiological Perspectives for Diagnosis of Vasospastic Angina with Coronary Angiography (이형성 협심증 진단 조영 검사의 방사선학적 관점)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.589-595
    • /
    • 2023
  • If complete coronary artery occlusion occurs due to severer coronary spasm, malignant arrhythmias can lead to death. Therefore, early screening for coronary artery spasm angina is essential. Among the test methods, the drug injection test through coronary angiography is generally performed. Therefore, the purpose of this study was to evaluate the advantages of ergonovine drug test for vasospasitc angina examination during coronary angiography, such as the relationship between the procedure time, contrast medium usage, and radiation exposure effects of coronary angiography. Follow-up data of 142 patients who underwent coronary angiography and variant angina examination from september 2021 to february 2023 were used. As a result of analyzing contrast usage dose and dose area product and air kerma dose and number of imaging series and procedure time, variant angina examination was statistically significantly higher than coronary angiography. (p<0.001) In conclusion, variant angina examination other than coronary artery angiography are radiologically negative. Therefore, we think it is better to avoid excessive inspection. Nevertheless, in the case of the provocation test, the longer the examination time, the higher the fluoroscopy time and the amount of contrast medium used, so it is better to conduct the test as quickly as possible or shorten it.

Preliminary Report of Gamma Knife Radiosurgery for the Movement Disorders (운동성 장애에 대한 감마나이프 시술의 초기경험)

  • Hong, Joon Ki;Kim, Moo Seong;Lee, Sun Il;Jung, Yong Tae;Kim, Soo Chun;Sim, Jae Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1024-1029
    • /
    • 2000
  • Objectives : With recent improvements in neuroimaging and the development of third and fourth-generation radiosurgical dose-planning soft ware, came a renewed interest in using radiosurgery for the treatment of movement disorders. Radiosurgery involves no opening of the cranium and no incisions, eliminating both the risk of hemorrhage from passing an electrode to the depths of meningitis from operative infection. It is for these reasons stereotactic radiosurgical treatment of movement disorders has value in a small subgroup of patients. The authors report four cases of Parkinson's disease and one case of dystonia that were treated by Gamma knife. Methods : Radiosurgical nucleus ventralis intermedius thalamotomy using the gamma knife unit was performed to make lesion in two Parkinson's disease patients. A radiation dose of 120Gy was delivered to nucleus using a single 4-mm collimator plug pattern following classic anatomical landmarks. Patients were followed for a median of 10.5 months(range 9-12 months). An independent neurological evaluation of tremor, based on the change in the United Parkinson's Disease Rating Scale tremor score(UPDRS), was correlated with a subjective evaluation. Gamma knife ventrolateral(V.O.P) thalamotomy was performed in one case of dystonia. A central dose of 150Gy was delivered and the patient was followed for 18 months. Gamma knife globus pallidus interna pallidotomy was performed in two Parkinson's disease patients. A radiation dose of 130Gy(range 120-140Gy) was delivered. Patients were followed for a median of 13 months(range 9-14 months). Result : Ventrolateral thalamotomy in dystonia produced regained left hand usage in order to be able to use the telephone. Ventralis intermedius thalamotomy produced an excellent improvement of the tremor in one case, mild improvement of the tremor in the other case of Parkinson's disease. A globus pallidus internalis(GPi) pallidotomy produced improvement of rigidity and dyskinesia : one other showed no change. There were no neurological complications. Conclusion : Gamma Knife thalamotomy considered a safe and effective technique for the treatment of tremor in Parkinson's disease. Although the results from Longer follow-up is not available yet, the short-term results seem to be encouraging.

  • PDF

Importance of Job Tasks, Job Training Requirement and Work Satisfaction felt by Dental Hygienists (치과위생사의 수행업무의 중요성·업무에 대한 교육훈련의 필요도와 만족도 조사연구)

  • Kang, Yong-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2005
  • The study aimed to estimate the importance of job tasks, job training requirement and work satisfaction felt by dental hygienists to help dental hygienists work efficiently and effectively. A total of 142 dental hygienists working in dental hospitals located in J participated in the study. A SPSS 10.10 for Windows was used for statistical analysis. The statistical significance was defined as ${\alpha}$=.05. The results of the study are summarized as follows: 1. The mean score for the importance of job tasks was 4.09. The respondents considered dental clinic management and assistance to dentists the most important among their job descriptions showing the mean score of 4.44. The need for job training was 4.15 in average. The respondents wanted to have training on how to make a dental health insurance claim to receive payment other than any training with the mean score of 4.42. The work satisfaction of the respondents was 3.65 in average. The respondents were most satisfied with their work in dental assistance. 2. By the category of job tasks, the levels of importance of job tasks, job training requirement and work satisfaction were higher in plague removal with an ultrasonic scaler related to clinical oral prophylaxis, pit and fissure sealants related to preventive dental treatment and instruction in the correct usage of toothbrush related to public dental health education 3. In dealing with dental radiation machines, the radiation protection was considered the most important. While the training for periapical radiography was most needed, the respondents were satisfied with working in the same area. The levels of job importance, training requirement and work satisfaction were high in preventive dental care in the community performed in relation to the public dental health care. 4. In the dental health insurance claim category, the levels of importance of job task, training requirement and work satisfaction were higher in insurance claiming. The levels of job importance and training requirement were high in dental clinic management and assistance to dentists performed for preventive dental treatment. The work satisfaction was higher in maintaining medical chart records. The levels of job importance, training requirement and work satisfaction were higher in dental assistance in relation to dental protection. 5. There was significant relationship between the level of importance and work experience. Those with a longer period of work experience had higher levels of job importance in dental health insurance claim, dental clinic management and assistance to dentists and the overall task(pE0.05). 6. A significant relationship was observed between the need for job training in dental cleaning and preventive dental treatment and work experience. Those with more than 8 years of work experience demonstrated that job training is most needed(pE0.05). 7. The work satisfaction level was higher in the group with more than 8 years of work experience, compared with those in other work experience periods(pE0.05). 8. A positive correlation was seen between the level of importance and the need for job training among three variables.

  • PDF

National Trends in Pediatric CT Scans in South Korea: A Nationwide Cohort Study (소아 전산화단층촬영의 국내 동향: 전국적 코호트 연구)

  • Nak Tscheol Kim;Soon-Sun Kwon;Moon Seok Park;Kyoung Min Lee;Ki Hyuk Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.138-148
    • /
    • 2022
  • Purpose This study evaluated the rates and annual trends of pediatric CT scans in South Korea using a nationwide population-based database. Materials and Methods Data regarding pediatric CT scan usage between 2012 and 2017 were retrieved from the health insurance review and assessment service. Data on the age, sex, diagnosis, and the anatomical area of involved patients were also extracted. Results A total of 576376 CT examinations were performed among 58527528 children aged below 18 years (9.8 scans/1000 children), and the number of CT examinations per 1000 children was noted to have increased by 23.2% from 9.0 in 2012 to 11.0 in 2017. Specifically, the number of CT examinations increased by 32.9% for the 6-12 years of age group (7.4/1000 to 9.8/1000) and by 34.0% for the 13-18 years of age group (11.4/1000 to 15.3/1000). Moreover, majority of the CT scans were limited to the head (39.1%), followed by the extremities (32.5%) and the abdomen (13.7%). Notably, the number of extremity CT scans increased by 83.6% (2.3/1000 to 4.2/1000), and its proportion as compared to other scans increased from 25.3% to 37.7%. Conclusion CT scans in the pediatric population increased continuously from 2012 to 2017 at an annual rate of 4.4%. Therefore, physicians should balance the benefits of CT with its potential harms from associated radiation exposure in pediatric patients.

The Adaptation of Ginseng Production of Semi-arid Environments The Example of British Columbia, Canada

  • Bailey, W.G.
    • Proceedings of the Ginseng society Conference
    • /
    • 1990.06a
    • /
    • pp.155-167
    • /
    • 1990
  • Ginseng Is renowned for both its medicinal and herbal uses and successful cultivation of Panax ginseng in Asia and Panax quinquefolium in North America has until recently taken place in the native geographical ranges of the plants. As a consequence of the potential high capital return and anticipated increases in consumer consumption, commercial cultivation of American ginseng now occurs well outside the native range of the plant in North America. In fact, the region of greatest expansion of cultivation is in the semi-arid interior region of British Columbia, Canada. Linked with this expansion is the potential domination of the ginseng industry by agricultural corporations. In the interior of British Columbia, the native deciduous forest environment of eastern North America is simulated with elevated polypropylene shade and a surface covering of straw mulch. The architecture of these environments is designed to permit maximum machinery usage and to minimize labor requirements. Further, with only a four- years growth cycle, plant densities in the gardens are high. In this hot, semi-arid environment, producers believe they have a competitive advantage over other regions in North America because of the low precipitation rates. This helps to minimize atmospheric humidity such that the conditions for fungal disease development are reduced. If soil moisture level become limited, supplemental water can be provided by irrigation. The nature of the radiation and energy balance regimes of the shade and many environments promotes high soil moisture levels. Also, the modified environment redlines soil heating. This can result in an aerial environment for the plant that is stressful and a rooting zone environment that is suloptimal. The challenge of further refining the man modified environment for enhanced plant growth and health still remains. Keywords Panax ginseng, Panax quinquefolium, cultivation, ginseng production.

  • PDF

Comparison of Marine Insolation Estimating Methods in the Adriatic Sea

  • Byun, Do-Seong;Pinardi, Nadia
    • Ocean Science Journal
    • /
    • v.42 no.4
    • /
    • pp.211-222
    • /
    • 2007
  • We compare insolation results calculated from two well-known empirical formulas (Socket and Beaudry's SB73 formula and the original Smithsonian (SMS) formula) and a radiative transfer model using input data predicted from meteorological weather-forecast models, and review the accuracy of each method. Comparison of annual mean daily irradiance values for clear-sky conditions between the two formulas shows that, relative to the SMS, the SB73 underestimates spring values by 9 W $m^{-2}$ in the northern Adriatic Sea, although overall there is a good agreement between the annual results calculated with the two formulas. We also elucidate the effect on SMS of changing the 'Sun-Earth distance factor (f)', a parameter which is commonly assumed to be constant in the oceanographic context. Results show that the mean daily solar radiation for clear-sky conditions in the northern Adriatic Sea can be reduced as much as 12 W $m^{-2}$ during summer due to a decrease in the f value. Lastly, surface irradiance values calculated from a simple radiative transfer model (GM02) for clear-sky conditions are compared to those from SB73 and SMS. Comparison with iu situ data in the northern Adriatic Sea shows that the GM02 estimate gives more realistic surface irradiance values than SMS, particularly during summer. Additionally, irradiance values calculated by GM02 using the buoy meteorological fields and ECMWF (The European Centre for Medium Range Weather Forecasts) meteorological data show the suitability of the ECMWF data usage. Through tests of GM02 sensitivity to key regional meteorological factors, we explore the main factors contributing significantly to a reduction in summertime solar irradiance in the Adriatic Sea.

Analysis on Patent Trends in Nonthermal Processing Technologies for Medicinal Herbs (한약재 가공 기술의 특허 동향 연구 - 비가열 가공 기술을 중심으로 -)

  • Kim, Kyoung Shin;Kim, Sung Gu;Chae, Suhn Kee;Kim, Byoung Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.4
    • /
    • pp.367-373
    • /
    • 2013
  • The purpose of this study was to analyze the patent application trend in the processing technology for medicinal herbs. Recently, in processing technology for medicinal herbs, experimental researches have frequently been published through papers in journals. However, the research results about the patent area were fewer than the others. We tried to analyze the patent application trend in nonthermal processing technologies for medicinal herbs by country as Korea, Japan, U.S.A. and Europe. The detailed technologies consisted of pulsed electric field, oscillatory magnetic field, intense pulsed light, ultrasonification, high hydrostatic pressure, microwave, radiation, Ohmic heating, and supercritical extraction. As a result we found that patents of nonthermal processing technologies has been growing steadily in quantity from 1980s and growing quickly since 2000s. The number of patent in Korea is larger than others as making up 70% in that whole. The number of patent in ultrasonification field was larger than others in portfolio analysis. Patent application trend in nonthermal processing technologies for ingestion occupies high share compared to other usage applications. In conclusion, patent trends of nonthermal processing technologies for medicinal herbs belong to the period in the development.