• Title/Summary/Keyword: Radiation Test

Search Result 1,580, Processing Time 0.03 seconds

Investigation of Knowledge and Awareness of Radiation of University Students - To the Radiation Non-Commissioned Personnel - (대학생의 방사선의 지식 및 인식 조사 - 방사선 비전공자를 대상으로 -)

  • Kang, Yeon-Hee;Park, Cheolwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.233-239
    • /
    • 2019
  • The purpose of this study was to investigate the knowledge and awareness about radiation use among non - radiation undergraduates. This analysis were used based on the collected questionnaires with Frequency, mean and standard deviation, t-test, one-way ANOVA. As a result, there was no significant difference between the groups in terms of gender and age. There were statistical differences in some items in the major field. In addition, the perception of radiation was more negative in women and under 25 years of age (p<0.05). The correlations between the sub - factors showed that the higher the knowledge of radiation, the higher the perception of knowledge and use of radiation. It is believed that university students will have a positive effect of contributing to the development of the radiation industry if they have a correct understanding of radiation because they are more likely to contribute to public opinion by advancing into society.

The awareness and performance towards the dental radiation protection behaviors in Busan and Gyeongnam (부산·경남 일부지역의 치과방사선 인식도와 수행도에 따른 치과방사선 방어행위)

  • Na, Hyeon-Hui;Jin, Hye-Jung;Lee, Min-Kyung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.5
    • /
    • pp.673-680
    • /
    • 2014
  • Objectives : The purpose of this study is to investigate the awareness and performance towards the dental radiation protection behaviors in dental institutions in Busan and Gyeongnam. Methods : Two hundred and one dental medical institutions in Busan and Gyeongnam participated in the survey from March 10 to April 4, 2014. The data were analyzed using SPSS 19.0 for ${\chi}^2$ test, t-test, ANOVA, and multiple regression analysis. Results : There were significant differences in the awareness and performance towards the radiation protection behaviors according to age, monthly income, and type of hospital(p<0.05). Protective equipment influenced on the awareness and performance of dental staff and patients(p<0.001). The important variables on dental radiation protection included protection facility and education of protective equipment. It is found the variable to affect the performance of dental radiation protection was protection facility, wearing of protective device staff and patients, education on RSM. Conclusions : These results can provide the basic data for the effective dental radiation safety management and improvement for the dental institutions.

The Improvement of China's Nuclear Safety Supervision Technical Support Ability

  • Han Wu;Guoxin Yu;Xiangyang Zheng;Keyan Teng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.4
    • /
    • pp.523-531
    • /
    • 2022
  • The International Atomic Energy Agency (IAEA) entails independent decision-making for the safety supervision of civil nuclear facilities. To evaluate and review the safety of nuclear facilities, the national regulatory body usually consults independent institutions or external committees. Technical Support Organizations (TSOs) include national laboratories, research institutions, and consulting organizations. Support from professional organizations in other countries may also be required occasionally. Most of the world's major nuclear power countries adopt an independent nuclear safety supervision model. Accordingly, China has continuously improved upon the construction of such a system by establishing the National Nuclear Safety Administration (NNSA) as the decision-making department for nuclear and radiation safety supervision, six regional safety supervision stations, the Nuclear and Radiation Safety Center (NSC), a nuclear safety expert committee, and the National Nuclear and Radiation Safety Supervision Technology R&D Base, which serves as the test, verification, and R&D platform for providing consultation and technical support. An R&D system, however, remains to be formed. Future endeavors must focus on improving the technical support capacity of these systems. As an enhancement from institutional independence to capability independence is necessary for ensuring the independence of China's nuclear safety regulatory institution, its regulatory capacity must be improved in the future.

구조 변경 기법을 이용한 로타리 컴프레서의 방사소음특성 분석 및 소음저감

  • 박상영;이상현;이수일;이승갑;박윤서
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.778-781
    • /
    • 1995
  • In this paper, sound radiation of a rotary compressor used in room air-conditioner is investigated. structural eigenmodes are identified through modal test. Since accumulator is found important factor of sound radiation, damping material was added around accumulator to reduce sound radiation level of rotary compressor. As result, sound radiation was reduced to 3 dB.

  • PDF

Radiation Effects of Proton Particles in Memory Devices

  • Lho, Young-Hwan;Kim, Ki-Yup
    • ETRI Journal
    • /
    • v.29 no.1
    • /
    • pp.124-126
    • /
    • 2007
  • In this letter, we study the impact of single event upsets (SEUs) in space or defense electronic systems which use memory devices such as EEPROM, and SRAM. We built a microcontroller test board to measure the effects of protons on electronic devices at various radiation levels. We tested radiation hardening at beam current, and energy levels, measured the phenomenon of SEUs, and addressed possible reasons for SEUs.

  • PDF

Feasibility Study of a Custom-made Film for End-to-End Quality Assurance Test of Robotic Intensity Modulated Radiation Therapy System

  • Kim, Juhye;Park, Kwangwoo;Yoon, Jeongmin;Lee, Eungman;Cho, Samju;Ahn, Sohyun;Park, Jeongeun;Choi, Wonhoon;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.189-195
    • /
    • 2016
  • This paper aims to verify the clinical feasibility of a custom-made film created by a laser cutting tool for End-to-End (E2E) quality assurance in robotic intensity modulated radiation therapy system. The custom-made film was fabricated from the Gafchromic EBT3 film with the size of $8^{{\prime}{\prime}}{\times}10^{{\prime}{\prime}}$ using a drawing that is identical to the shape and scale of the original E2E film. The drawing was created by using a computer aided design program with the image file, which is obtained by scanning original E2E film. Beam delivery and evaluations were respectively performed with the original film and the custom-made film using fixed-cone collimator on three tracking modes: 6D skull (6DS), Xsight spine (XS), and Xsight lung (XL). The differences between total targeting errors of the original and custom-made films were recorded as 0.17 mm, 0.3 mm, and 0.17 mm at 6DS, XS, and XL tracking modes, respectively. This indicates that the custom-made film could yield nearly equivalent results to those of the original E2E film, given the uncertainties caused by distortions during film scanning and vibrations associated with film cutting. By confirming the clinical feasibility of a custom-made film for E2E testing, it can be expected that economic efficiency of the testing will increase accordingly.

Proficiency Test for the Dosimetry Audit Service Provider

  • Chul-Young Yi;In Jung Kim;Jong In Park;Yun Ho Kim;Young Min Seong
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.72-79
    • /
    • 2022
  • Purpose: The proficiency test was conducted to assess the performance of the dosimetry audit service provider in the readout practice of the dose delivered to patients in medical institutions. Methods: A certain amount of the absorbed dose to water for the high-energy X-ray from the medical linear accelerator (LINAC) installed in the Korea Research Institute of Standards and Science (KRISS) was delivered to the postal dose audit package given by the dosimetry audit service provider, in which the radio-photoluminescence (RPL) glass dosimeters were mounted. The dosimetry audit service provider read the RPL glass dosimeters and sent the readout dose value with its uncertainty to KRISS. The performance of the dosimetry audit service provider was evaluated based on the En number given in ISO/IEC 17043:2010. Results: The evaluated En number was -0.954. Based on the ISO/IEC 17043, the performance of the dosimetry service provider is "satisfactory." Conclusions: As part of the conformity assessment, the KRISS performed the proficiency test over the postal dose audit practice run by the dosimetry audit service provider. The proficiency test is in line with confirming the traceability of the medical institutions to the primary standard of absorbed dose to the water of the KRISS and ensuring the confidence of the dosimetry audit service provider.

Effects of radiation therapy on the dislocation resistance of root canal sealers applied to dentin and the sealer-dentin interface: a pilot study

  • Pallavi Yaduka;Rubi Kataki;Debosmita Roy;Lima Das;Shachindra Goswami
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.22.1-22.12
    • /
    • 2021
  • Objectives: This study evaluated and compared the effects of radiation therapy on the dislocation resistance of AH Plus and BioRoot RCS applied to dentin and the sealer-dentin interface. Materials and Methods: Thirty single-rooted teeth were randomly assigned to 2 groups (n = 15 each): AH Plus (Dentsply DeTrey) and BioRoot RCS (Septodont). Each group was subdivided into control and experimental groups. The experimental group was subjected to a total radiation dose of 60 Gy. The root canals of all samples were cleaned, shaped, and obturated using the single-cone technique. Dentin slices (1 mm) were sectioned from each root third for the push-out test and scanning electron microscopy (SEM) was done to examine the sealer-dentin interface. The failure mode was determined using stereomicroscopy. Bond strength data were analyzed by the independent t-test, 1-way analysis of variance, and the Tukey post hoc test (α = 0.05). Results: Significantly lower bond strength was observed in irradiated teeth than non-irradiated teeth in the AH Plus group (p < 0.05). The BioRoot RCS group showed no significant reduction in bond strength after irradiation (p > 0.05) and showed a higher post-irradiation bond strength (209.92 ± 172.26 MPa) than the AH Plus group. SEM revealed slightly larger gap-containing regions in irradiated specimens from both groups. Conclusions: The dislocation resistance of BioRoot RCS was not significantly changed by irradiation and was higher than that of AH Plus. BioRoot RCS may be the sealer of choice for root canal treatment in patients undergoing radiation therapy.

Effect of Radiation Resistance by Chitosan through Micronuclei Test after X-ray Irradiation (키토산의 방사선 저항 효과에 관한 연구)

  • Kim Jung-Sam
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.28 no.1
    • /
    • pp.34-38
    • /
    • 2002
  • As the radiation is widely used in atomic power generation and medical parts. If it was not very carefully treated, Especially, to consideration of the perspicacity ability of radiation or radionuclide will be caused cytogenetic damages. To evaluation of

  • PDF