• Title/Summary/Keyword: Radiation Quality Factor

Search Result 160, Processing Time 0.035 seconds

A Study on Resonance Properties of a Terahertz Asymmetric Split-Loop Resonator Type Metamaterial for High Quality Factor (테라헤르츠 비대칭 분리고리공진기 메타물질의 높은 품질인자를 위한 공진 특성에 관한 연구)

  • Park, Dae-Jun;Ryu, Han-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.663-669
    • /
    • 2016
  • A terahertz asymmetric split-loop resonator (ASLR) was analyzed for use in high-sensitivity sensing applications. Its structural asymmetricity induces an asymmetric Fano resonance which has a high quality factor compared to the symmetric eigen-resonance. The variations of the resonant frequency, transmission coefficient, and quality factor of the ASLR in the eigen and Fano resonances are analyzed as a function of its structural asymmetricity. Also, the surface current densities on the ASLR in both resonances are calculated to analyze the main cause of the variations of its transmission characteristics. The surface current of the ASLR in the eigen resonance shows a dipole resonance, which increases the radiation loss and reduces the quality factor. On the other hand, the surface current of the ASLR in the Fano resonance shows a trapped or quadrupole mode which has a low radiation loss. Therefore, the ASLR operated in the Fano resonance has a high quality factor. Terahertz, high-performance filters and high sensitivity sensors can be developed based on our analysis results of the ASLR having a high quality factor. These high-performance devices based on terahertz metamaterials could increase the adoption of terahertz industrial applications.

The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography (디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2012
  • In digital mammography, Exposure factor were automatically chosen using by measurement breast thickness and the density of mammary gland. It may cause a increase glandular dose. The purpose of this study was to investigate optimal image quality in digital magnification mammography to decrease radiation exposure of patient dose. Auto mode gives the best image quality however, AGD showed better image quality. Image quality of manual mode passed phantom test and SNR at 55% mAs of auto mode commonly used in the digital magnification mammography. Also it could reduce AGD. According to result, manual mode may reduce the unnecessary radiation exposure in digital magnification mammography.

A Study on the relationship of family support and personality with quality of life in the Patients receiving radiotherapy for breast cancer (방사선 치료를 받는 유방암 환자의 가족지지와 성격이 삶의 질에 미치는 영향)

  • Rhee Dong Soo;Rou Jae Man;Jee Dong Hwa;Kim Jong Deok;Noh Young Hee;Han You Jeong;So Hyang sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.155-164
    • /
    • 2002
  • This descriptive correlation study was undertaken in order to investigate the relationship of family support and personality with quality of life in patients receiving radiotherapy for breast cancer and to provide basic data to help them improve a better quality of life. This subjects for this study were 74 out-patients undergoing a radiation therapy at C hospital in Kwang-Ju. The data were obtained using a convenience sampling technique. The tool of this study were Ro's qualify of life scale, Kang's family support scale and Wallston & others health locus of control scale. The data were analyzed using a SAS program for percentage, mean, standard deviation, Pearson Correlation Coefficient, GLM. The results were as fellows: 1. The total average score of the quality of life of the subjects was 137.22 (minimum score 38-maximum score 227), item mean score(range 1-5) was 3.15. The total average score of the family support of the subjects was 40.38(minimum score 21-maximum score 47), item mean score(range 1-5) was 3.69. The total average score of health locus of control of the subjects was 42.47(minimum score 28-maximum score 59), item mean score(range 1-6 was 3.69. 2. The results of the analysis of the relationship between the quality of life scores and the health locus of control were as follows : the total average score of the qualify of life of internal locus of control scale was 133.50, he total average score of the quality of life of external locus of control scale was 138.41. 3. There was positive correlation between the health locus of control and the quality of life(r=0.0722, p=0.5413). 4. There were significant positive correlation between family support and quality of life(r=0.2328, p=0.0399). The results of the analysis of the relationship between the each factor in the quality of life scores and family support were as fellows : There were significant difference between the self esteem factor(r=0.2974, p=0.0124), relationship with family factor(r=0.2657, p=0.0241)

  • PDF

History of the Photon Beam Dose Calculation Algorithm in Radiation Treatment Planning System

  • Kim, Dong Wook;Park, Kwangwoo;Kim, Hojin;Kim, Jinsung
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.54-62
    • /
    • 2020
  • Dose calculation algorithms play an important role in radiation therapy and are even the basis for optimizing treatment plans, an important feature in the development of complex treatment technologies such as intensity-modulated radiation therapy. We reviewed the past and current status of dose calculation algorithms used in the treatment planning system for radiation therapy. The radiation-calculating dose calculation algorithm can be broadly classified into three main groups based on the mechanisms used: (1) factor-based, (2) model-based, and (3) principle-based. Factor-based algorithms are a type of empirical dose calculation that interpolates or extrapolates the dose in some basic measurements. Model-based algorithms, represented by the pencil beam convolution, analytical anisotropic, and collapse cone convolution algorithms, use a simplified physical process by using a convolution equation that convolutes the primary photon energy fluence with a kernel. Model-based algorithms allowing side scattering when beams are transmitted to the heterogeneous media provide more precise dose calculation results than correction-based algorithms. Principle-based algorithms, represented by Monte Carlo dose calculations, simulate all real physical processes involving beam particles during transportation; therefore, dose calculations are accurate but time consuming. For approximately 70 years, through the development of dose calculation algorithms and computing technology, the accuracy of dose calculation seems close to our clinical needs. Next-generation dose calculation algorithms are expected to include biologically equivalent doses or biologically effective doses, and doctors expect to be able to use them to improve the quality of treatment in the near future.

A Study on the absorbed dose to water for high energy electron beams using Water equivalency of plastic phantom (고 에너지 전자선에서 물등가 고체팬톰을 이용한 물 흡수선량 측정에 관한 연구)

  • Sin, Dong-Ho;Sin, Dong-Oh;Kim, Sung-Hoon;Park, Sung-Yong;Ji, Young-Hoon;Ahn, Hee-Kyung;Kang, Jin-Oh;Hong, Seong-Eon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.166-169
    • /
    • 2004
  • In the International Code of Practice for dosimetry TRS-398 published by International Atomic Energy Agency(IAEA), water equivalency plastic phantom may be used under certain circumstances for electron beam dosimetry for beam quality E0${\leq}$ 10 MeV. In this study, Palstic Water$^{TM}$ and Virtual Water$^{TM}$ were evaluated in order to determine fluence scaling factor hpl. Plastic phantom was evaluated for five electron energy from 6 MeV to 20 MeV. From the measured data of Palstic Water$^{TM}$, the fluence scaling factor hpl was found to be average 0.9964 and Virtual Water$^{TM}$ fluence scaling factor was 1.0156.

  • PDF

The Study on Interpretation of the Scatter Degradation Factor using an additional Filter in a Medical Imaging System (의료 영상 시스템에서 부가 필터를 이용한 산란 열화 인자의 해석에 관한 연구)

  • Kang, Sang Sik;Kim, Kyo Tae;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.589-596
    • /
    • 2019
  • X-rays used for diagnosis have a continuous energy distribution. However, photons with low energy not only reduce image contrast, but also contribute to the patient's radiation exposure. Therefore, clinics currently use filters made of aluminum. Such filters are advantageous because they can reduce the exposure of the patient to radiation. However, they may have negative effects on imaging quality, as they lead to increases in the scattered dose. In this study, we investigated the effects of the scattered dose generated by an aluminum filter on medical image quality. We used the relative standard deviation and the scatter degradation factor as evaluation indices, as they can be used to quantitatively express the decrease in the degree of contrast in imaging. We verified that the scattered dose generated by the increase in the thickness of the aluminum filter causes degradation of the quality of medical images.

Investigation of 3D Printed Electrically Small Folded Spherical Meander Wire Antenna

  • Kong, Myeongjun;Shin, Geonyeong;Lee, Su-Hyeon;Yoon, Ick-Jae
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.4
    • /
    • pp.228-232
    • /
    • 2017
  • The radiation properties and fabrication precautions of a 3D printed, electrically small folded spherical meander wire monopole antenna are investigated. The antenna is self-resonant and shows sufficiently high radiation efficiency at an electrical size ka of 0.4, with the radiation quality factor Q approaching the lower physical bound. In antenna fabrication, the possible structural deformation due to gravity is examined before the antenna frame is 3D-printed. The required conductivity is achieved by multiple manual paintings of a silver paste. The radiation efficiency and pattern show very good agreement with the computed expectations, whereas the resonant frequency deviates by 11.8%. The method to minimize such a fabrication error when using 3D printing technology for wire antennas is discussed.

Quality Assurance of Operation of Enhanced Dynamic Wedges in Linac (선형가속기의 동적쐐기(EDW) 작동에 대한 품질보증)

  • Jeong, Dong-Hyeok;Kim, Jhin-Kee;Kang, Jeong-Ku;Son, Kwang-Jae;Lee, Jeong-Ok
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.133-141
    • /
    • 2010
  • The evaluation of Varian enhanced dynamic wedges (EDW) were performed in terms of quality assurance in external radiotherapy. The seven (10, 15, 20, 25, 30, 45, 60 deg.) EDW angles were evaluated for 6 and 15 MV x-rays in Varian Linac. The STT (segmented treatment table) for a field were calculated and compared with actual movement of the jaw using Dynalog files in order to evaluate mechanical operation. Two dimensional array detector and an ionization chamber were used to measure dose distributions in phantom from Linac. The mechanical movement of jaw was agreed with its expectation and two dimensional dose distributions including beam profiles were in agreement with RTP data approximately. In comparison with RTP calculations the percentage difference of output dose values for 100 MU irradiation was less than 2.9% and measured wedge factor was less than 2.6%. These results are shown that there is no problem in clinical applications of EDW equipped on this linac.

Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor (선질계수에 의한 피부입사선량 계산법)

  • Kim, Sung-Chul;Kim, Chong-Yeal;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.258-267
    • /
    • 2010
  • This interest in radiation exposure makes increasing doctor's awareness and knowledge of radiation dose in patients during X-ray test important in reducing patient's uneasiness. However, very few facilities are equipped with measurement instruments. Therefore, an intensive study to find out patient dose using computational method has been initiated. This study used special features of the bit system and NDD-M and directly measured the output dose of diagnostic X-ray instruments used in Korea to create tables. Two different methods were found to be adequate when applied to cases when X-ray outputs were both known and unknown, and comparative experiments with real measurement doses were carried out. Presented methods were found to provide more accurate results compared to the bit system and NDD-M. Therefore, patient dose during clinical trials were found to be more easily acceptable to medical personnel in the radiation field in terms of radiation exposure and reduction of medical X ray dose.