• 제목/요약/키워드: Radiation Quality Factor

검색결과 161건 처리시간 0.029초

THE FACTORS WHICH AFFECT THE EXTERNAL RADIATION DOSE RATE OF PET-CT PATIENTS

  • Cho, Ihn Ho;Kim, Su Jin;Han, Eun Ok
    • Journal of Radiation Protection and Research
    • /
    • 제37권4호
    • /
    • pp.231-236
    • /
    • 2012
  • This study derived measures to reduce exposure doses by identifying factors which affect the external radiation dose rate of patients treated with radiopharmaceuticals for PET-CT tests. The external radiation dose rates were measured on three parts of head, thorax and abdomen at a distance of 50cm from the surface of 60 PET-CT patients. It showed there are changes in factors affecting the external radiation dose rate over time after the administration of F-18 FDG. The external radiation dose rate was lower in the patients with more water intake than those with less water intake before the injection of radiopharmaceuticals at all three points: right after the injection of radiopharmaceuticals (average 4.17 mins), after the pre-PEET-CT urination step (average 77.47 mins), and right after the PET-CT test (average 114.15 mins). The study also found there is a need to increase the amount of water intake before the injection of radiopharmaceuticals in order to maintain a low external radiation dose rate in patients. This strategy is only possible under the assumption that the quality of the video has not changed after conducting this study on the relations between the image and quality. This study also found a need to use radiopharmaceuticals with the minimum amount needed for each patient because F-FDG doses affects the external radiation dose rate at the point right after the injection of radiopharmaceuticals. Urination frequency was the most significant factor to affect the external radiation dose rates at the point right after the PET-CT test and the point after the pre-PET-CT urination step. There is a need to realize the strategy to increase the urination frequency of patients to maintain the external radiation dose rate low (average 77.47 mins) before and after the injection of radiopharmaceuticals. In addition, at this point, there is a need to take advantage of personal strategies because the external radiation dose rate is lower if the fasting time is shorter, the contrast medium is used, and the amount of water intake is increased after the administration of radiopharmaceuticals. Finally this study found the need to be able to generalize these findings through an in-depth research on the factors affecting the external radiation dose rate, which includes radiopharmaceutical dose, urination frequency, the amount of water intake, fasting time and the use of contrast medium.

디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가 (The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography)

  • 김미영;김화선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권4호
    • /
    • pp.293-298
    • /
    • 2012
  • 디지털 유방촬영술은 유방의 두께 및 유선조직의 밀도에 따라 노출조건이 자동으로 이루어지는 자동노출제어장치를 사용하고 있는데 이는 피폭선량을 증가시키는 원인이 되기도 한다. 이 연구에서는 디지털 유방확대촬영술에서 영상의 질을 유지하며 불필요한 방사선 피폭을 줄이기 위한 최적의 방사선량 촬영조건을 알아보았다. 자동노출방식을 사용할 경우 가장 좋은 영상화질을 얻을 수 있었으나 평균유선선량 역시 가장 높았다. 수동노출방식의 경우 자동노출방식의 55 % 정도의 mAs 값만으로도 기준 팬텀영상 점수와 신호대잡음비를 얻을 수 있으며 평균유선선량은 55 % 이하로 줄일 수 있었다. 위와 같은 결과를 참고로 하면 디지털 유방확대촬영 시 자동노출방식보다는 수동노출방식을 이용함으로써 불필요한 환자의 피폭선량을 줄일 수 있을 것이라 생각된다.

방사선 치료를 받는 유방암 환자의 가족지지와 성격이 삶의 질에 미치는 영향 (A Study on the relationship of family support and personality with quality of life in the Patients receiving radiotherapy for breast cancer)

  • 이동수;류재만;지동화;김종덕;노영희;한유정;소향숙
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.155-164
    • /
    • 2002
  • This descriptive correlation study was undertaken in order to investigate the relationship of family support and personality with quality of life in patients receiving radiotherapy for breast cancer and to provide basic data to help them improve a better quality of life. This subjects for this study were 74 out-patients undergoing a radiation therapy at C hospital in Kwang-Ju. The data were obtained using a convenience sampling technique. The tool of this study were Ro's qualify of life scale, Kang's family support scale and Wallston & others health locus of control scale. The data were analyzed using a SAS program for percentage, mean, standard deviation, Pearson Correlation Coefficient, GLM. The results were as fellows: 1. The total average score of the quality of life of the subjects was 137.22 (minimum score 38-maximum score 227), item mean score(range 1-5) was 3.15. The total average score of the family support of the subjects was 40.38(minimum score 21-maximum score 47), item mean score(range 1-5) was 3.69. The total average score of health locus of control of the subjects was 42.47(minimum score 28-maximum score 59), item mean score(range 1-6 was 3.69. 2. The results of the analysis of the relationship between the quality of life scores and the health locus of control were as follows : the total average score of the qualify of life of internal locus of control scale was 133.50, he total average score of the quality of life of external locus of control scale was 138.41. 3. There was positive correlation between the health locus of control and the quality of life(r=0.0722, p=0.5413). 4. There were significant positive correlation between family support and quality of life(r=0.2328, p=0.0399). The results of the analysis of the relationship between the each factor in the quality of life scores and family support were as fellows : There were significant difference between the self esteem factor(r=0.2974, p=0.0124), relationship with family factor(r=0.2657, p=0.0241)

  • PDF

History of the Photon Beam Dose Calculation Algorithm in Radiation Treatment Planning System

  • Kim, Dong Wook;Park, Kwangwoo;Kim, Hojin;Kim, Jinsung
    • 한국의학물리학회지:의학물리
    • /
    • 제31권3호
    • /
    • pp.54-62
    • /
    • 2020
  • Dose calculation algorithms play an important role in radiation therapy and are even the basis for optimizing treatment plans, an important feature in the development of complex treatment technologies such as intensity-modulated radiation therapy. We reviewed the past and current status of dose calculation algorithms used in the treatment planning system for radiation therapy. The radiation-calculating dose calculation algorithm can be broadly classified into three main groups based on the mechanisms used: (1) factor-based, (2) model-based, and (3) principle-based. Factor-based algorithms are a type of empirical dose calculation that interpolates or extrapolates the dose in some basic measurements. Model-based algorithms, represented by the pencil beam convolution, analytical anisotropic, and collapse cone convolution algorithms, use a simplified physical process by using a convolution equation that convolutes the primary photon energy fluence with a kernel. Model-based algorithms allowing side scattering when beams are transmitted to the heterogeneous media provide more precise dose calculation results than correction-based algorithms. Principle-based algorithms, represented by Monte Carlo dose calculations, simulate all real physical processes involving beam particles during transportation; therefore, dose calculations are accurate but time consuming. For approximately 70 years, through the development of dose calculation algorithms and computing technology, the accuracy of dose calculation seems close to our clinical needs. Next-generation dose calculation algorithms are expected to include biologically equivalent doses or biologically effective doses, and doctors expect to be able to use them to improve the quality of treatment in the near future.

고 에너지 전자선에서 물등가 고체팬톰을 이용한 물 흡수선량 측정에 관한 연구 (A Study on the absorbed dose to water for high energy electron beams using Water equivalency of plastic phantom)

  • 신동호;신동오;김성훈;박성용;지영훈;안희경;강진오;홍성언
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.166-169
    • /
    • 2004
  • IAEA의TRS-398물 흡수선량 표준 프로토콜에서 고 에너지 전자선의 물 흡수선량 결정에 있어서 10MeV이하의 에너지 에서만 사용하길 권고하고 있다. Plastic Water$^{TM}$ Virtual Water$^{TM}$ 고체 팬톰을 이용하여 전자선에 대한 hpl값을 측정하였다. 측정결과 Plastic Water$^{TM}$의 경우 6 MeV에서 20 MeV가지의 전자선에 대해 평균 0.9964의 값을 나타냈고, Virtual Water$^{TM}$의 경우 1.0156의 값을 나타냈다.

  • PDF

의료 영상 시스템에서 부가 필터를 이용한 산란 열화 인자의 해석에 관한 연구 (The Study on Interpretation of the Scatter Degradation Factor using an additional Filter in a Medical Imaging System)

  • 강상식;김교태;박지군
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.589-596
    • /
    • 2019
  • 진단방사선 영상을 획득하기 위해 이용되는 X-ray는 연속적인 에너지 분포를 가지지만 저에너지 광자의 경우에는 영상 형성 보다는 환자피폭에 더 많은 기여를 하는 것으로 알려져 있다. 이러한 저에너지 광자를 제거하기 위해 임상에서는 알루미늄 필터를 적용하고 있으나 이는 빔 경화 현상으로 인한 영상 품질에 악영향을 미칠 가능성이 있다. 이에 본 연구에서는 알루미늄 필터에 의한 산란 선량이 의료 영상의 품질에 미치는 영향에 대하여 고찰하고자 하였다. 또한, 영상의 대조도 저하를 정량적으로 표현하기 위해 상대 표준 편차 및 산란 열화 인자를 평가 지표로서 활용하였다. 연구 결과, 70 kVp 이상의 전압에서 진단 영상을 확보 시 NCRP에 의해 권장되는 2.5 mmAl를 기준에서 전방산란율 분석 결과 0.69 %, 산란 열화 인자 분석 결과는 0.005, NNPS 분석 결과 3.59 mm2의 변화가 나타났다. 이러한 연구 결과를 바탕으로 알루미늄 필터의 두께가 증가함에 따라 발생하는 산란 선량이 의료 영상의 품질을 저하시키는 것을 정량적으로 검증하였다.

Investigation of 3D Printed Electrically Small Folded Spherical Meander Wire Antenna

  • Kong, Myeongjun;Shin, Geonyeong;Lee, Su-Hyeon;Yoon, Ick-Jae
    • Journal of electromagnetic engineering and science
    • /
    • 제17권4호
    • /
    • pp.228-232
    • /
    • 2017
  • The radiation properties and fabrication precautions of a 3D printed, electrically small folded spherical meander wire monopole antenna are investigated. The antenna is self-resonant and shows sufficiently high radiation efficiency at an electrical size ka of 0.4, with the radiation quality factor Q approaching the lower physical bound. In antenna fabrication, the possible structural deformation due to gravity is examined before the antenna frame is 3D-printed. The required conductivity is achieved by multiple manual paintings of a silver paste. The radiation efficiency and pattern show very good agreement with the computed expectations, whereas the resonant frequency deviates by 11.8%. The method to minimize such a fabrication error when using 3D printing technology for wire antennas is discussed.

선형가속기의 동적쐐기(EDW) 작동에 대한 품질보증 (Quality Assurance of Operation of Enhanced Dynamic Wedges in Linac)

  • 정동혁;김진기;강정구;손광재;이정옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.133-141
    • /
    • 2010
  • 선형가속기의 동적쐐기(enhanced dynamic wedge: EDW)의 품질보증을 위하여 다양한 방법으로 동적쐐기의 특성을 평가하였다. 본 연구에서는 6 MV와 15 MV 엑스선에 대하여 각각 7종(10, 15, 20, 25, 30, 45, 60도)의 EDW를 평가하였다. EDW 작동에 필요한 STT(segmented treatment table)를 계산으로 구하고 로그파일을 통하여 기계적 작동을 평가하였으며, 이차원배열형검출기와 전리함을 사용하여 팬텀속 선량분포를 측정하고 치료계획시스템(RTP)과 비교하였다. EDW의 기계적 작동은 예상과 잘 일치하였으며, 빔측면도를 포함한 이차원선량분포는 근사적으로 RTP 계산과 일치하였다. 선형가속기 조사량 100 MU에 대한 출력선량은 RTP 계산과 2.9% 이내로 일치하였으며, 측정된 쐐기인자는 RTP 계산과 최대 2.6%를 보였다. 이 결과들은 본 선형가속기에 장착된 EDW의 임상적 적용에 문제가 없음을 의미한다.

선질계수에 의한 피부입사선량 계산법 (Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor)

  • 김성철;김종일;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제10권2호
    • /
    • pp.258-267
    • /
    • 2010
  • 방사선피폭에 대한 관심이 높아지면서 X선 검사시에 환자에게 조사되는 피폭선량을 정확히 알고 있다는 것은 환자의 불안을 해소하고 또 방사선사나 의사가 피폭선량 경감의식을 향상시키는 데 중요하지만, 임상에서 측정기를 보유하고 있는 시설은 극소수에 불과하다. 본 연구에서는 bit system 및 NDD-M법의 특징을 살려서 우리나라에 사용되고 있는 진단용 X선장치의 출력선량을 직접 측정하여 도표화 하고, X선 출력선량을 아는 경우 또는 모르는 경우 모두에서 적절히 적용할 수 있게 두 가지 방법을 제시하여 실측선량과 비교 실험을 하였다. 그 결과 bit system 및 NDD-M법보다 정확도가 우수한 결과를 나타내어 임상에서 환자가 받는 선량을 더욱 쉽게 알 수 있게 됨으로 방사선관련 종사자들의 의료피폭에 대한 관심이 더욱 높아지고 의료선량감소에 한층 더 노력하는 계기가 될 것으로 사료된다.