• 제목/요약/키워드: Radiation Over-exposure

검색결과 163건 처리시간 0.028초

동종조직에서의 방사선 멸균효과에 대한 연구 (THE EFFECT OF STERILIZATION OF GAMMA IRRADIATION ON ALLOGENEIC TISSUE MATERIALS)

  • 이은영;김성진;박우윤;김경원;엄인웅;류주연
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권6호
    • /
    • pp.523-527
    • /
    • 2005
  • Allograft donations are commonly found to be contaminated. The most of tissue banks has promoted the use of ionizing radiation for the sterilization of biological tissues. The potential for transmission of human infectious diseases and contamination of microorganism has created serious concern for the continued clinical use of hard and soft-tissue allografts. Tissue banks have employed 15-25kGy for sterilization of hard and tendon allografts, which, according to the national standards, approaches the level at which the tissue quality is adversely affected for transplantation. The donations of allogeneic tissues to the Korea Tissue Bank over a 2-year period were reviewed, and the incidence and bacteriology of contamination were detailed. Clinical outcomes were determined for donors who had positive cultures at the time of retrieval and during the processing and they were compared with those of post sterilization. After exposure of the frozen block bone to 25kGy and the processed tissues to 15kGy of gamma irradiation, the authors were able to demonstrate complete inactivation of the bacteria. The aim of this study was to obtain the effects of gamma irradiation and the irradiation dose according to the type of tissue, through conventional microbiologic test without on influence of biocompatibility in allografts. The contamination rate after the final irradiation sterilization is 0% in the processed allografts. This may be due to the fact that the gamma radiation and processing steps are effective to control contamination.

백하수오 에탄올추출물이 방사선조사에 따른 흰쥐의 혈구 및 장기에 미치는 영향 (The Effects of Cynanchi wilfordii Radix Ethanol Extracts upon Irradiated Rat's Blood and Organ)

  • 김장오;최준혁;신지혜;정도영;민병인
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.451-459
    • /
    • 2016
  • 방사선 사고 및 방사선 치료 등 방사선에 의한 과피폭의 피해를 줄이기 위해 방사선방호제 개발연구는 활발히 진행되고 있다. 이에 화학적 합성물이 아닌 항산화, 항암, 면역 증강에 효과적인 것으로 알려진 백하수오를 이용하여 방사선방호효과를 확인하였다. 백하수오 에탄올추출물을 Sprague Dawley Rat (SD Rat)에 14일간 1일 1회 경구 투여하고, 7 Gy X-ray를 조사한 후 1일, 4일, 7일, 21일의 시간 변화에 따른 혈구성분, 비장 지수의 변화 및 간과 자궁의 조직변화를 관찰하였다. 실험결과 백하수오 에탄올추출물을 섭취한 실험군의 백혈구 수치(p < 0.05)와 비장 지수(p < 0.05)가 대조군보다 회복이 빠른 것을 확인하였다. 간 조직에서는 핵의 응축, 세포질의 팽창, 염증세포의 침윤이 감소하였으며, 자궁샘 조직은 세포고사가 감소한 것을 확인하였다. 위의 결과를 토대로 백하수오 에탄올추출물은 방사선 조사에 따른 혈구 및 장기의 피해를 줄일 수 있는 새로운 방사선방호제로써 유용할 것으로 기대되며, 방사선 사고와 같은 비상관리 분야에 적절한 시사점을 제공할 수 있다.

Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구 (A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy)

  • 송종남;설광욱;홍성일;최정구
    • 한국방사선학회논문지
    • /
    • 제5권3호
    • /
    • pp.135-141
    • /
    • 2011
  • X선에 대한 피폭을 최소화 하려는 앞치마는 차폐 성능이 좋지 않으면 방사선 작업종사자나 환자에게 불필요한 피폭을 줄 수 있으며 나아가 방사선 만성 장해를 유발시키기도 한다. 이를 방지하기 위하여 제조사에서는 0.25mm이상의 납 당량을 가진 앞치마을 제작한다. 본 논문에서는 앞치마을 제조사별, 납 당량별로 분류하여 차폐성능을 측정, 우수한 앞치마를 구비하는데 기초자료를 제공하고 성능 평가 방법의 접근을 용이하게 하고자 한다. 0.05mm의 Pb과 4개의 제조사(H, X, I, J)에서 제작된 앞치마을 3종류의 납 당량별(0.50mmPb, 0.35mmPb, 0.25mmPb)로 분류하고 Apron은 크게 Clavicle part, Chest part, Abdomen part, Pelvis part로 구분하여 투시촬영장치를 이용, 방사선 투과율, 차폐율과 표준편차를 측정하였다. 0.5mmPb 앞치마의 방사선투과율과 차폐율을 측정한 결과 I사의 앞치마가 가장 우수한 97.96%의 차폐율을 보였으며, J사의 앞치마는 96.25%의 차폐율을 보이며 가장 저조하였다. 0.35mmPb 앞치마의 경우 I사의 Apron이 96.79%의 가장 우수한 차폐율을 보였으며 A사의 앞치마는 가장 저조한 95.81%의 차폐율을 보였다. 0.25mmPb 앞치마의 경우 X사의 앞치마가 가장 우수한 90.91%의 차폐율을 보였으며 H사의 앞치마는 가장 저조한 88.82%의 차폐율을 나타냈다. 또한 0.5mm 납을 함유한 앞치마의 차폐율에 대한 표준편차는 X사(0.125)와 I사(0.190)가 가장 낮게 나타났고 J사(0.447)가 가장 높게 나타났으며, 0.35mm 납을 함유한 앞치마는 I사(0.231)가 가장 낮았다. 0.25mm 납을 함유한 앞치마는 X사(0.364)로 다른 제조업체의 앞치마보다 표준편차가 가장 작았다. 일정한 납 당량이 함유된 앞치마는 지금까지 방사선으로부터 피폭을 방지하는 보편적이며 일반적인 보호 장구이다. 그러므로 환자, 보호자 또는 방사선 관련 작업종사자는 방사선 피폭을 최대한 방지하기 위하여 양질의 앞치마를 사용하여야 할 것이며 이러한 실험적인 방법을 통하여 객관적이며 현실적인 차폐율을 평가해야 할 것이다.

교육용 치과 엑스선 발생장치에 대한 방사선 안전 관리 실태 조사 (Research on the Actual Condition of the radiation Safety Management(RSM) for the Educated Training of the Dental Diagnostics X-ray Generators)

  • 이미현;유윤식;이재승;임인철
    • 한국방사선학회논문지
    • /
    • 제8권7호
    • /
    • pp.467-477
    • /
    • 2014
  • 본 연구의 목적은 교육용 치과 엑스선 발생장치를 설치 및 가동 중인 전국 치위생(학)과를 대상으로 방사선 작업종사자의 방사선 안전 관리 실태를 설문 조사하고 이를 체계적으로 추이 분석하여 교육용 치과 엑스선 발생장치의 안전한 이용 기반을 확립하기 위한 기초 자료로 제공하고자 하였다. 이를 위하여 교육용 치과 엑스선 발생장치의 방사선 안전 관리와 관계되는 원자력 관계 법령 및 국내 방사선 안전성 평가 및 규제 기술 개발 현황에 대한 용역 보고서를 참고하여 포괄적인 문헌 조사를 하였으며 이를 토대로 응답자의 일반적 특성, 방사선안전관리자의 위상, 방사선 안전관리 현황과 지식 및 의식 수준에 대한 설문지를 작성하였다. 본 연구는 국내 교육기관 내 방사선안전관리자와 교육용 치과 엑스선 발생장치를 운전 가능한 학사 및 실습 조교, 전임 교원 224명을 대상으로 설문 조사를 시행하여 설문 응답 누락 및 불충분한 응답을 제외한 95부를 회수하여 분석 자료로 이용하였다. 분석 방법은 일반적 특성 및 방사선안전관리자의 위상은 빈도와 백분율을 구하였으며 방사선 안전 관리 현황과 지식 및 의식 수준은 빈도 분석과 설문 문항별 연관성 분석을 위한 ${\chi}^2$ 검정(chi-square test)과 수준간 연관성을 구하기 위한 피어슨 상관분석(Pearson correlation analysis)을 하였다. 결과적으로 교육용 치과 엑스선 발생장치의 운영은 대부분 대학 이상의 사회적 교육 수준이 높고 치위생학을 전공한 20대에서 40대의 여성이 담당하고 있었으며 남성과 비교하여 방사선 안전 관리에 대한 의식 수준이 높게 나타났으며 통계적으로 유의한 선형적 관계를 보였다(${\chi}^2$ >5, 0.1${\chi}^2$ >5, 0.3${\chi}^2$ >5, 0.3

복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향 (Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography)

  • 김유현;권수일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

Non-Hodgkin Lymphoma and Pesticide Exposure in Turkey

  • Yildirim, Mustafa;Karakilinc, Hulya;Yildiz, Mustafa;Kurtoglu, Erdal;Dilli, Utku Donem;Goktas, Sevil;Demirpence, Ozlem;Kaya, Vildan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권6호
    • /
    • pp.3461-3463
    • /
    • 2013
  • Background: Non-Hodgkin lymphoma (NHL) is a solid tumour of lymphocytes, important elements in the immune system. According to 2006 data, in Turkey the incidence was 6.5 per 100,000 in males, and 4.4 in females. The relationship between the use of pesticides and development of NHL has been extensively investigated in many studies, and it has been demonstrated that the risk of NHL is increased by exposure to such compounds. Antalya is a region of intensive agricultural activity. In this study, the relationship between the incidence of lymphoma in Antalya and the amount of pesticides employed was investigated. Materials and Methods: The study used data from 1995 to 2010 on the patients from the databank of TR Ministry of Health, Antalya Provincial Health Directorate, Cancer Registration Center and the patients who were histopathologically diagnosed with NHL during these years. Results: The relationship between the amount of pesticide used and the incidence was studied with the Spearman correlation analysis and the p value was found as 0.05. The correlation coefficient was 0.497. An increase in the NHL incidence over the years was identified, with a 2.42-fold increment found from 1995 to 2005 and a 2.77 fold elevation from 1995 to 2010. The use of pesticides increased 1.89 fold over the same period. Conclusions: Our study investigated the relationship of the pesticides used with NHL patients diagnosed during the same year. Since the time elapsing after exposure to pesticides until the development of cancer is not clear, no comparison can be made at present. We believe that the increase in use of pesticides since 1995 may be associated with the increase in the incidence of NHLand therefore that further studies on the issue including measurements of serum pesticide levels, are required.

자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과 (Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction)

  • 정지상;최병욱;김성호;김영모;심지나;안호식;진덕은;임재식;강성호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.177-185
    • /
    • 2014
  • 자동노출제어를 이용한 X선 흉부촬영에서 AEC 위치를 알 수 있도록 고안 된 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과에 대하여 알아보고자 하였다. 흉부전용 디지털 X선 장비(DRS, LISTEM, Korea)를 이용하여 흉부촬영 검사를 하여야 하는 성인 남녀 880명을 대상으로 하였다. 대상환자 모두에서 자동노출제어(이온 전리조 양측 상단 2개 사용) 사용하여 촬영하였다. 조사야 크기는 $17{\times}17inch$, 관전압은 120kVp, 촬영거리는 180cm로 설정 하였다. 대조군 440명은 Detector 내에 양측 폐가 위치하도록 하여 촬영하였고, 실험군 440명은 이온 전리조 위치를 방사선사가 알 수 있도록 표지자를 만든 후 이온 전리조 위치에 양측 폐를 위치 할 수 있도록하여 촬영하였다. 모든 환자의 나이, 몸무게, 키와 DAP 값을 측정 하였으며, PCXMC2.0을 이용하여 환자의 유효선량 값을 계산 하였다. 대조군 440명(M:F=245:195)의 평균 나이는 53.9세였으며, 평균 BMI는 23.4였다. BMI 분포는 저체중 35명, 정상 279명, 과체중 106명, 비만 20명이었고, 평균 DAP는 $223.56mGycm^2$, 평균유효선량은 0.045mSv 였다. 실험군 440명(M:F=197:243)의 평균 나이는 53.7세 였고, 평균BMI는 22.7이었다. BMI 분포는 저체중 34명, 정상 316명, 과체중 85명, 비만 5명이었고, 평균 DAP는 $207.36mGycm^2$, 평균유효선량은 0.041mSv 였다. 평균유효선량은 실험군이 대조군에 비해 0.004mSv(9.7%) 감소하였다. 실험군 유효선량 표준편차의 2배인 0.056mSv 이상의 과다피폭을 받은 환자는 실험군에 비하여 대조군에서 많았다 (65명(14.7%) 대 19명(4.3%), p=0.006, t-test). 자동노출제어를 이용한 X선 흉부촬영에서 환자에 맞는 정확한 선량을 위해서는 이온 전리조 위치와 검사부위를 일치 시켜야 하며 따라서 이온 전리조 위치를 알 수 있도록 고안한 표시 방법은 환자가 받을 수 있는 불필요한 방사선 피폭을 줄일 수 있는 방법이다.

진단용 X선장치의 성능 실태 조사연구 (A Study on the Test of Efficiency of the Diagnostic X-ray Equipment according to Their Rectifications)

  • 선종률
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.44-48
    • /
    • 1997
  • For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When the equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service.

  • PDF

비전리방사선을 이용한 미생물 균주 멸균효과 (Sterilization Effect of Microbial Strains by using Non-ionizing Radiation)

  • 정경환;서정민
    • 한국방사선학회논문지
    • /
    • 제14권6호
    • /
    • pp.833-839
    • /
    • 2020
  • 전 세계적으로 중증 급성 호흡 증후군 코로나바이러스에 의해 감염예방 및 사회적 인식이 크게 변화되었으며, 그로 인해 의료 원내감염 노출이 높은 환자에 관한 감염관리 지침 및 과정을 더 강화하고 관리감시를 더 철저히 하고 있다. 감염예방을 위해서는 멸균이 최우선으로 시행이 되어야 하며, 저비용, 쉬운 설치와 조작이 쉬운 멸균법을 찾아 적절한 멸균효과를 제시하고자 한다. 본 연구에서는 충치균을 오염시켜 출력 4 W, 조사 시간 60, 150, 300 sec로 자외선 살균기를 이용하였으며, 레이저는 출력 0.8, 1.5 W로 각각 파장 266, 355 nm로 조사하였다. 자외선 살균기는 150 sec 이상에서 감염예방에 안전성을 나타내었으며, 레이저는 1.5 W와 0.8 W, 266 nm에서 예방의 안전성을 나타내었다. 결과에서 출력이 높고 253.7 nm에 가까운 파장일수록 멸균효과는 뛰어났다.

Sun Burn Incidence and Knowledge of Greek Elementary and High School Children about Sun Protection

  • Saridi, Maria Ioannis;Toska, Aikaterini George;Rekleiti, Maria Dimitrios;Tsironi, Maria;Geitona, Maria;Souliotis, Kyriakos
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권4호
    • /
    • pp.1529-1534
    • /
    • 2015
  • Introduction: Overexposure to sun radiation and particularly its accumulation during childhood and adolescence is a significant risk factor for skin cancer development. The sun burn is particularly important. Aim: To estimate sun burn incidence in young pupils in a coastal area of Greece. Materials and Methods: Two surveys were conducted in a school population in the same district in Greece, over different periods of time, in young people 9 to 18 years old (n=2 977). Anonymous questionnaires were completed. Levels of significance were two-tailed and statistical significance was set at p=0.05. SPSS 17.0 software was used for statistical analysis. Results: From the individual characteristics of the participants it was shown that the majority of them had dark hair and fair skin, whereas a significant percentage reported the existence of moles on face and their body (83.4% vs 68.1%). The sun burn incidence was high in adolescents and the younger pupils (41.9% vs 55.6%). The younger aged children who were living in an urban area had significantly higher rates of sun burn than those living in semi-urban areas (33.8% vs 24.8%, p=0.020). As far as the knowledge of pupils about the risks of sun radiation it was shown that the elementary school pupils had better knowledge than those at high school. Finally, those with better knowledge had the fewer sun burns (Mean 2.83 SD 0.87, p<0.001). Conclusions: The contribution of knowledge to the decrease of sun burn incidence is important as long as this is continuous. Therefore, the education should concern not only children but also teachers and parents in the context of continuous and systematic programs of health education.