Personal Dosimeters Worn by Radiation Workers in Korea: Actual Condition and Consideration of Their Proper Application for Radiation Protection

  • Eunbi Noh;Dalnim Lee;Sunhoo Park;Songwon Seo
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.3
    • /
    • pp.162-166
    • /
    • 2023
  • Background: Assessment of the radiation doses to which workers are exposed can differ depending on the placement of dosimeters on the body. In addition, it is affected by whether the placement is under or over a shielding apron. This study aimed to evaluate the actual positioning of personal dosimeters on the body, with or without shielding aprons, among radiation workers in Korea. Materials and Methods: We analyzed the survey data, which included demographic characteristics, such as sex, age, occupation, work history, and placement of the personal dosimeter being worn, from a cohort study of Korean radiation workers. We assessed the use of personal dosimeters among workers, stratified by sex, age, working period, starting year of work, and occupation. Results and Discussion: Overall, high compliance (89.1% to 99.0%) with the wearing of dosimeters on the chest was observed regardless of workers' characteristics, such as age, sex, occupation, and work history. However, the placement of dosimeters, either under or over the shielding aprons, was inconsistent. Overall, 40.1% of workers wore dosimeters under their aprons, while the others wore dosimeters over their aprons. This inconsistency indicates that radiation doses are possibly measured differently under the same exposure conditions solely owing to variations in the placement of worn dosimeters. Conclusion: Although a lack of uniformity in dosimeter placement when wearing a shielding apron may not cause serious harm in radiation dose management for workers, the development of detailed guidelines for dosimeter placement may improve the accuracy of dose assessment.

OPERATIONAL EXPERIENCE OF A TWO-DOSIMETER ALGORITHM FOR BETTER ESTIMATION OF EFFECTIVE DOSE AT KOREAN NUCLEAR POWER PLANTS

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.165-169
    • /
    • 2009
  • Two dosimeters are provided to radiation workers participating in tasks where high radiation exposure is expected during maintenance at nuclear power plants. At Korean nuclear power plants, two dosimeters are currently provided for tasks where exposure rates exceed 1 mSv/hr, the difference of equivalent dose to specific parts of the body is more than 30% and an exposure of more than 2 mSv is expected in a single task. These conditions for the provisioning of two dosimeters are based on previous field test results, and it is recommended that the dosimeters be worn on the chest and back. It was also found that the workers felt it was more convenient when they wore two dosimeters on chest and back rather than on chest and head. After the application of previous field test results to practice, it was found that the calculated effective dose for workers during radiation work was lower than the maximum dose of chest or back dosimeter by approximately 10%-30%. This performance is regarded not only to meet the international guideline but also to provide convenience for workers during radiation work.

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

Occupational Radiation Exposure of Emergency Medical Technicians in Emergency Medical Centers in Korea (우리나라 응급의료센터 응급구조사의 직업적 방사선 노출)

  • Lee, Hyeongyeong;Park, Jeongim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.3
    • /
    • pp.170-179
    • /
    • 2017
  • Objectives: This study aims to investigate the occupational radiation exposures of emergency medical technicians(EMTs) in emergency medical centers in Korea. The results will provide a basis for developing prevention programs to minimize adverse health effects relating to radiation exposure among emergency medical technicians working in this area. Methods: Radiation exposure doses were measured for twenty-two EMTs working in six emergency medical centers. Thermo Luminescent Dosimeters(TLD) were placed on three representative body parts, including chest, neck, and a finger. Measurements were conducted over the entire working hours of the participants for foor weeks. Dosimeters were analyzed according to a standard method by a KFDA-designated lab. Detection rate, annual radiation exposure dose, and relative levels to dose limit were derived based on the measured doses from the dosimeters. SPSS/Win 18.0 software(IBM, US) was used for statistical analysis. Results: Detection rates were 45.5%, 36.4%, and 45.5% for the dosimeters sampled from chest, neck, and a finger, respectively. The average annual doses were $2.39{\pm}3.44mSv/year$(range 0.38-10.0 mSv/year) for the chest, $2.72{\pm}3.05mSv/year$(2.00-11.34) for the neck, and $20.98{\pm}17.57mSv/year$(1.25-53.50) for the hand dose. The average annual eye dose was estimated to $3.61{\pm}2.37mSv/year$(1.50-8.34). The exposure dose levels of EMTs were comparable to those of radiologists, who showed relatively higher radiation dose among health care workers, as reported in another study. Conclusions: EMTs working in emergency medical centers are considered to be at risk of radiation exposure. Although the radiation exposure dose of EMTs does not exceed the dose limit, it is not negligible comparing to other professionals in health care sectors.

Investigation of Personal Dosimeter Loss Case and Measures to Prevent Loss (개인선량계 분실 사례 및 분실 방지 방안 조사)

  • Seong-Woo Park;Hyeon-Sik Park;Yeong-Jae Park;Geong-Jae Lee;Gi-Baek Oh;Seong-Ha Lee;Min-Seok Kim;Ju-Eon Park;Moon-Hui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.66-70
    • /
    • 2023
  • Purpose It is intended to improve the management efficiency of personal dosimeters by analyzing and sharing personal dosimeter loss cases and loss prevention measures. Materials and Methods From 2017 to 2021, data on the number of lost personal dosimeters were collected at large hospitals, and the number of personal dosimeters issued and lost were investigated. Results In order to prevent loss by institution, methods such as the use of auxiliary rings, contact stickers and dosimeter necklaces were implemented. Conclusion Hospitals are a business that frequently changes clothes, such as surgical gowns and work clothes, so there is a lot of loss. In addition, it was confirmed that the loss rate increases as the number of personal dosimeters issued increases.

  • PDF

Measurement of ECF for $CaSO_4:Dy$ Thermoluminescent Dosimeters ($CaSO_4:Dy$ 열형광선량계의 소자보정인자(ECF) 산출)

  • Lim, Kil-Sung;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.4
    • /
    • pp.231-236
    • /
    • 2005
  • Dosimeters are manufactured from same process in the manufacturer but the deviation of TL raw counts exists among the dosimeters. TL raw counts are also gradually degrade due to multiple readings and physical abuse. ECF (Element Correction Factor) correct the degradation and deviation of TL raw counts to the average TL raw counts of reference dosimeters. Procedures for producing ECF of thermoluminescent dosimeters were described In detail. ECFs of 319 reference, control and field dosimeters were measured three times and average of three ECF values was calculated. Also, % CV(Coefficient of Variation) of three ECF values was calculated to verify ECF. ECF & % CV distributions for the field and control dosimeters are presented. TL raw counts of field dosimeters, being used about 6 times for the past 3 years, were almost unchanged, but those of control dosimeters being used more frequently, were degraded about 4.7 %.

Quenching Effect in an Optical Fiber Type Small Size Dosimeter Irradiated with 290 MeV·u-1 Carbon Ions

  • Hirata, Yuho;Watanabe, Kenichi;Uritani, Akira;Yamazaki, Atsushi;Koba, Yusuke;Matsufuji, Naruhiro
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.222-228
    • /
    • 2016
  • Background: We are developing a small size dosimeter for dose estimation in particle therapies. The developed dosimeter is an optical fiber based dosimeter mounting an radiation induced luminescence material, such as an OSL or a scintillator, at a tip. These materials generally suffer from the quenching effect under high LET particle irradiation. Materials and Methods: We fabricated two types of the small size dosimeters. They used an OSL material Eu:BaFBr and a BGO scintillator. Carbon ions were irradiated into the fabricated dosimeters at Heavy Ion Medical Accelerator in Chiba (HIMAC). The small size dosimeters were set behind the water equivalent acrylic phantom. Bragg peak was observed by changing the phantom thickness. An ion chamber was also placed near the small size dosimeters as a reference. Results and Discussion: Eu:BaFBr and BGO dosimeters showed a Bragg peak at the same thickness as the ion chamber. Under high LET particle irradiation, the response of the luminescence-based small size dosimeters deteriorated compared with that of the ion chamber due to the quenching effect. We confirmed the luminescence efficiency of Eu:BaFBr and BGO decrease with the LET. The reduction coefficient of luminescence efficiency was different between the BGO and the Eu:BaFBr. The LET can be determined from the luminescence ratio between Eu:BaFBr and BGO, and the dosimeter response can be corrected. Conclusion: We evaluated the LET dependence of the luminescence efficiency of the BGO and Eu:BaFBr as the quenching effect. We propose and discuss the correction of the quenching effect using the signal intensity ratio of the both materials. Although the correction precision is not sufficient, feasibility of the proposed correction method is proved through basic experiments.

Web-based Personal Dose Management System for Data Recording on Dosimeter Usage: A Case of Tanzania Atomic Energy Commission

  • Mseke, Angela;Ngatunga, John Ben;Sam, Anael;Nyambo, Devotha G.
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.2
    • /
    • pp.15-22
    • /
    • 2022
  • Modern technology drives the world, increasing performance while reducing labor and time expenses. Tanzania Atomic Energy Commission (TAEC) tracks employee's levels of exposure to radiation sources using dosimeters. According to legal compliance, workers wear dosimeters for three months and one month at the workplace. However, TAEC has problems in tracking, issuing and returning dosimeters because the existing tracking is done manually. The study intended to develop a Personal Dose Management System (PDMS) that processes and manages the data collected by dosimeters for easy and accurate records. During the requirements elicitation process, the study looked at the existing system. PDMS' requirement gathering included document reviews, user interviews, and focused group discussions. Development and testing of the system were implemented by applying the evolutionary prototyping technique. The system provides a login interface for system administrators, radiation officers, and Occupational Exposed Workers. The PDMS grants TAEC Staff access to monitor individual exposed workers, prints individual and institutional reports and manages workers' information. The system reminds the users when to return dosimeters to TAEC, generate reports, and facilitates dispatching and receiving dosimeters effectively. PDMS increases efficiency and effectiveness while minimizing workload, paperwork, and inaccurate records. Therefore, based on the results obtained from the system, it is recommended to use the system to improve dosimeter data management at the institution.

APPLICATION OF ALANINE/ESR SPECTRUM SHAPE CHANGE IN GAMMA DOSIMETRY

  • Choi, Hoon;Kim, Jeong-In;Lee, Byung-Ill;Lim, Young-Ki
    • Nuclear Engineering and Technology
    • /
    • v.42 no.3
    • /
    • pp.313-318
    • /
    • 2010
  • Alnine pellets were installed in a nuclear power plant for one or two operation cycles and measured by electron spin resonance (ESR) spectrometers for dosimetry. Dose and "x/y ratio", i.e., satellite peak over main center peak ratio, were measured for the returned alanine dosimeters from the nuclear power plant and compared to the values of reference alanine dosimeters exposed only to gamma rays. The variation of the x/y ratio change depended on the population of radicals from each radiation component with different LET. The gamma dose in a mixed radiation field was estimated by an additive gamma ray irradiation experiment and the measured dose rate at specified locations in the containment building.

How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

  • Kim, Ah Na;Chang, Young Jae;Cheon, Bo Kyung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.27 no.2
    • /
    • pp.145-151
    • /
    • 2014
  • Background: The physician's hands are close to the X-ray field in C-arm fluoroscopy-guided pain interventions. We prospectively investigated the radiation attenuation of Proguard RR-2 gloves. Methods: In 100 cases, the effective doses (EDs) of two dosimeters without a radiation-reducing glove were collected. EDs from the two dosimeters-one dosimeter wrapped with a glove and the other dosimeter without a glove-were also measured at the side of the table (Group 1, 140 cases) and at a location 20 cm away from the side of the table (Group 2, 120 cases). Mean differences such as age, height, weight, radiation absorbed dose (RAD), exposure time, ED, and ratio of EDs were analyzed. Results: In the EDs of two dosimeters without gloves, there were no significant differences ($39.0{\pm}36.3{\mu}Sv$ vs. $38.8{\pm}36.4{\mu}Sv$) (P = 0.578). The RAD ($192.0{\pm}182.0radcm^2$) in Group 2 was higher than that ($132.3{\pm}103.5radcm^2$) in Group 1 (P = 0.002). The ED ($33.3{\pm}30.9{\mu}Sv$) of the dosimeter without a glove in Group 1 was higher than that ($12.3{\pm}8.8{\mu}Sv$) in Group 2 (P < 0.001). The ED ($24.4{\pm}22.4{\mu}Sv$) of the dosimeter wrapped with a glove in Group 1 was higher than that ($9.2{\pm}6.8{\mu}Sv$) in Group 2 (P < 0.001). No significant differences were noted in the ratio of EDs ($73.5{\pm}6.7%$ vs. $74.2{\pm}9.3%$, P = 0.469) between Group 1 and Group 2. Conclusions: Proguard RR-2 gloves have a radiation attenuation effect of 25.8-26.5%. The radiation attenuation is not significantly different by intensity of scatter radiation or the different RADs of C-arm fluoroscopy.