• 제목/요약/키워드: Radiation Compensation

검색결과 75건 처리시간 0.028초

표준 감마선 전리함 장치에 의한 방사능 비교 측정 (Comparative Measurement of Radioactivity with Standard Gamma-ray Ionization Chamber System)

  • 박태순;우동호;오필제;황선태
    • Journal of Radiation Protection and Research
    • /
    • 제9권1호
    • /
    • pp.11-18
    • /
    • 1984
  • Well type 전리함과 미세전류 측정희로를 사용하여 표준 감마선 전리함 장치를 개발하였다. 미세전류는 automatic Townsend balance with stepwise compensation방법을 사용하여 측정하였다. $^{226}Ra$을 기준 선원으로 택하여 감마 방출핵종인 $^{241}Am,\;^{133}Ba,\;^{60}Co,\;^{134}Cs,\;^{137}Cs^{22}Na$에 대한 비교 교정인자를 산출하였으며, 감마에너지의 함수로서 검출 효율 곡선을 구하였다.

  • PDF

Reproduction strategy of radiation data with compensation of data loss using a deep learning technique

  • Cho, Woosung;Kim, Hyeonmin;Kim, Duckhyun;Kim, SongHyun;Kwon, Inyong
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2229-2236
    • /
    • 2021
  • In nuclear-related facilities, such as nuclear power plants, research reactors, accelerators, and nuclear waste storage sites, radiation detection, and mapping are required to prevent radiation overexposure. Sensor network systems consisting of radiation sensor interfaces and wxireless communication units have become promising tools that can be used for data collection of radiation detection that can in turn be used to draw a radiation map. During data collection, malfunctions in some of the sensors can occasionally occur due to radiation effects, physical damage, network defects, sensor loss, or other reasons. This paper proposes a reproduction strategy for radiation maps using a U-net model to compensate for the loss of radiation detection data. To perform machine learning and verification, 1,561 simulations and 417 measured data of a sensor network were performed. The reproduction results show an accuracy of over 90%. The proposed strategy can offer an effective method that can be used to resolve the data loss problem for conventional sensor network systems and will specifically contribute to making initial responses with preserved data and without the high cost of radiation leak accidents at nuclear facilities.

열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가 (Evaluation of the Breast plan using the TLD and Mosfet for the skin dose)

  • 김선명;김영범;이상록;백상윤;정세영
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.107-113
    • /
    • 2015
  • 목 적 : 유방암 치료에 있어 피부선량의 측정은 매우 중요하다. 치료계획시에는 처방선량에 비해 초과선량이나 부족선량이 생길 수 있으므로 이에 대한 유방암의 여러 가지 치료계획간 피부선량 평가가 필요하다. 이에 대해 본원에서는 다양한 선량계를 이용하여 선량을 분석하여 유방암치료에 적용하고자 한다. 대상 및 방법 : 유방암은 기본적으로 접선방향 치료계획 시 일어나는 skin dose(Drain site, Scar)의 선량차이를 알아보기 위하여 인체모형팬텀을 이용하였다. 인체모형팬텀을 전산화단층촬영하고 전산화치료계획에서 open과 쐐기필터(Wedge filter)를 이용한 치료계획, Field-in-Field를 이용한 치료계획, 그리고 Dose fluence를 이용한 Irregular compensation 치료계획을 세우고 컴퓨터치료계획 프로그램(Eclipse)으로 선량관심점과 측정점의 선량을 비교하였다. 치료실에서 인체모형팬텀을 위치시키고 선량비교를 위하여 각 치료계획 측정점에 열형광선량계(themoluminesence dosimeter, TLD)와 MOSFET(Metal oxide-silicon field effect transistor)을 이용하여 선량을 측정하여 비교평가 하였다. 결 과 : 피부선량은 치료계획 중심점을 기준으로 위와 아래는 Dose fluence를 이용한 Irregular compensation 치료계획 사용 시 MOSFET을 이용한 선량측정에서 가장 많은 선량이 들어가는 것으로 나타났다. 내측과 외측의 측정선량은 open과 쐐기필터 치료계획에서 TLD와 MOSFET을 이용하여 측정시 5.7%에서 10.3%까지 낮게 나타났다. 반대쪽 유방의 선량은 open 치료계획이 가장 적었고, Dose fluence를 이용한 Irregular compensation 치료계획을 사용 시 가장 많은 선량이 측정되었다. 치료종별 치료계획상에서는 내측과 외측의 선량편차가 가장 컸으며, TLD와 MOSFET 측정시에도 같은 경향을 보였다. 외측은 TLD, 내측은 MOSFET이 가장 편차가 컸다. 결 론 : 치료계획에 따른 피부선량은 전반적으로 Dose fluence를 이용한 Irregular compensation의 치료계획을 사용 시 가장 많이 들어가는 것으로 나타났으며, 이는 많은 MLC의 움직임에 의한 산란선 영향으로 생각된다. 모든 치료계획에서 피부의 위치에 따라 약간의 차이는 있으나 부족선량이 생기는 부분에서는 내측의 내유임파절(Intramammary lymph nodes)선량이나 Scar, Drain site등에서 세심한 주의가 필요하다. 부족선량을 높이기위해서는 Dose fluence를 이용한 Irregular compensation의 치료계획을 사용하는 것이 좋겠으나, 전체적인 선량을 높이기보다는 선택적인 범위내에서 선량을 높이게 되므로 환자의 연령이나 움짐임 등을 고려하여 치료기술을 선택하는 것이 바람직할 것으로 사료된다.

  • PDF

유한 배플 원통 진동체의 수중 방사 임피던스에 대한 실험적 연구 (Experimental Study of the In-Water Radiation Impedance of the Finite Baffle Cylinder Radiator)

  • 김원호;윤종락
    • 한국음향학회지
    • /
    • 제13권2호
    • /
    • pp.23-29
    • /
    • 1994
  • 본 논문에서는 원통형 압전 진동체에 대한 수중 방사 임피던스를 유한 배플 구조에서의 측정 결과와 무한 배플 구조에서의 이론 결과를 비교하여 방사 임피던스에 대한 배플의 영향을 규명하였다. 배플의 길이가 증가할수록 방사 임피던스의 측정치는 무한 배플에서의 이론치에 접하하며, 배플의 영항은 방사저항에서 보다 방사 리액턴스에서 더 지배적 임을 보인다. 따라서 음향 변환기의 설계시 무한 배플 구조에서의 방사 임피던스 이론 결과를 적용하기 위해서는 배플길이에 따른 임피던스의 보상이 수행되어야 한다.

  • PDF

Radiation-hardened-by-design preamplifier with binary weighted current source for radiation detector

  • Minuk Seung;Jong-Gyun Choi ;Woo-young Choi;Inyong Kwon
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.189-194
    • /
    • 2024
  • This paper presents a radiation-hardened-by-design preamplifier that utilizes a self-compensation technique with a charge-sensitive amplifier (CSA) and replica for total ionizing dose (TID) effects. The CSA consists of an operational amplifier (OPAMP) with a 6-bit binary weighted current source (BWCS) and feedback network. The replica circuit is utilized to compensate for the TID effects of the CSA. Two comparators can detect the operating point of the replica OPAMP and generate appropriate signals to control the switches of the BWCS. The proposed preamplifier was fabricated using a general-purpose complementary metal-oxide-silicon field effect transistor 0.18 ㎛ process and verified through a test up to 230 kGy (SiO2) at a rate of 10.46 kGy (SiO2)/h. The code of the BWCS control circuit varied with the total radiation dose. During the verification test, the initial value of the digital code was 39, and a final value of 30 was observed. Furthermore, the preamplifier output exhibited a maximum variation error of 2.39%, while the maximum rise-time error was 1.96%. A minimum signal-to-noise ratio of 49.64 dB was measured.

국내 방사선작업종사자에게 발생한 암의 방사선 인과도를 평가하기 위한 인과확률 계산 프로그램 (Program for Estimating the Probability of Causation to Korean Radiation Workers with Cancer)

  • 정미선;진영우;김종순
    • Journal of Radiation Protection and Research
    • /
    • 제29권4호
    • /
    • pp.221-230
    • /
    • 2004
  • 방사선작업종사자에게 발생한 암의 방사선 인과도를 평가하기 위한 통계적 측도로 인과확률(Probability of Causation)이 주로 이용된다. 인과확률의 계산 과정에는 다양한 형태의 불확실성이 존재하며, 따라서 인과확률은 하나의 점추정치(point estimate)가 아니라 여러 불확실성을 반영한 분포 또는 신뢰구간으로 평가되어야 한다. 본 연구에서는 국내 방사선작업종사자에게서 발생한 암의 방사선 인과도를 평가하기 위하여, 한국인의 기저자료를 반영하며 가장 최근에 발표된 NCI-CDC 모형에 근거하여 인과확률의 분포를 계산하도록 개발된 전산 프로그램 RHRI-PEPC를 소개한다. 또한 방사선작업종사자의 가상 피폭시나리오에 대한 모의실험을 통해, 인과확률의 점추정치와 불확실성 분포에 의한 방사선 인과도 평가 결과의 차이를 살펴보고 분포에 의한 평가의 경우 적절한 신뢰도 선택의 필요성을 제시한다.

실리콘 핀 포토다이오드를 이용한 능동형 방사선 피폭 전자선량계의 구현 (Implementation of Electronic Personal Dosimeter Using Silicon PIN Photodiode)

  • 이운근;백광렬;권석근
    • 제어로봇시스템학회논문지
    • /
    • 제9권4호
    • /
    • pp.296-303
    • /
    • 2003
  • A personal portable type electronic dosimeter using silicon PIN photodiode and small GM tube is recently attracting much attention due to its advantages such as an immediate indication function of dose and dose rate, alerting function, and efficient management of radiation exposure history and dose data. We designed and manufactured a semiconductor radiation detector aimed to directly measure X-ray and v-ray irradiated in silicon PIN photodiode, without using high-priced scintillation materials. Using this semiconductor radiation detector, we developed an active electronic dosimeter, which measures the exposure dose using pulse counting method. In this case, it has a shortcoming of over-evaluating the dose that shows the difference between the dose measured with electronic dosimeter and the dose exposed to the human body in a low energy area. We proposed an energy compensation filter and developed a dose conversion algorithm to make both doses indicated on the detector and exposed to the human body proportional to each other, thus enabling a high-precision dose measurement. In order to prove its reliability in conducting personal dose measurement, crucial for protecting against radiation, the implemented electronic dosimeter was evaluated to successfully meet the IEC's criteria, as the KAERI (Korea Atomic Energy Research Institute) conducted test on dose indication accuracy, and linearity, energy and angular dependences.

EXPERIMENTAL STUDY ON MEASUREMENT OF EMISSIVITY FOR ANALYSIS OF SNU-RCCS

  • CHO YUN-JE;KIM MOON OH;PARK GOON-CHERL
    • Nuclear Engineering and Technology
    • /
    • 제38권1호
    • /
    • pp.99-108
    • /
    • 2006
  • SNU-RCCS is a water pool type RCCS (Reactor Cavity Cooling System) developed for VHTR (Very High Temperature Reactor) application by SNU (Seoul National University). Since radiation heat transfer is the major process of passive heat removal in a RCCS, it is important to determine the precise emissivity of the reactor vessel. Review studies have used a constant emissivity in the passive heat removal analysis, even though the emissivity depends on many factors such as temperature, surface roughness, oxidation level, wavelength, direction, atmosphere conditions, etc. Therefore, information on the emissivity of a given material in a real RCCS is essential in order to properly analyze the radiation heat transfer in a VHTR. The objectives of this study are to develop a method for compensation of the factors affecting the emissivity measurement using an infrared thermometer and to estimate the true emissivity from the measured emissivity via the developed method, especially in the SNU-RCCS environment. From this viewpoint, we investigated factors such as the attenuation effect of the window, filling gas, and the effect of background radiation on the emissivity measurements. The emissivity of the vessel surface of the SNU-RCCS facility was then measured using a sight tube. The background radiation was subsequently removed from the measured emissivity by solving a simultaneous equation. Finally, the calculated emissivity was compared with the measured emissivity in a separate emissivity measurement device, yielding good agreement with the emissivity increase with vessel temperature in a range of 0.82 to 0.88.