• 제목/요약/키워드: Radiation Absorbed Dose

검색결과 399건 처리시간 0.026초

177Lu-EDTMP radiation absorbed dose evaluation in man based on biodistribution data in Wistar rats

  • Reza Bagheri
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.254-260
    • /
    • 2023
  • Skeletal metastases are common in patients suffering from various primary cancers. Radiopharmaceuticals are an effective option for bone pain palliation. In this work, the radiation absorbed dose of 177Lu-EDTMP radiopharmaceutical was estimated for adult man based on biodistribution data in Wistar rats. The MIRD dose calculation method and the Sparks and Aydogan methodology were applied. The results shows that about 46% of injected activity is cumulated on the surface of the trabecular and cortical bones. Radiation absorbed doses of red bone marrow and osteogenic cells were estimated to about 1.1 and 6.2 mGy/MBq, respectively. The maximum administrated activity was obtained 27 MBq/kg of body weight with an effective dose of 0.23 mSv/MBq. The results were compared with other available data from literature. This study indicated that 177Lu-EDTMP provides therapeutic efficacy for achieving bone pain palliation with low undesired dose to other normal organs.

Dose Estimation Model for Terminal Buds in Radioactively Contaminated Fir Trees

  • Kawaguchi, Isao;Kido, Hiroko;Watanabe, Yoshito
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.143-151
    • /
    • 2022
  • Background: After the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, biological alterations in the natural biota, including morphological changes of fir trees in forests surrounding the power plant, have been reported. Focusing on the terminal buds involved in the morphological formation of fir trees, this study developed a method for estimating the absorbed radiation dose rate using radionuclide distribution measurements from tree organs. Materials and Methods: A phantom composed of three-dimensional (3D) tree organs was constructed for the three upper whorls of the fir tree. A terminal bud was evaluated using Monte Carlo simulations for the absorbed dose rate of radionuclides in the tree organs of the whorls. Evaluation of the absorbed dose targeted 131I, 134Cs, and 137Cs, the main radionuclides subsequent to the FDNPP accident. The dose contribution from each tree organ was calculated separately using dose coefficients (DC), which express the ratio between the average activity concentration of a radionuclide in each tree organ and the dose rate at the terminal bud. Results and Discussion: The dose estimation indicated that the radionuclides in the terminal bud and bud scale contributed to the absorbed dose rate mainly by beta rays, whereas those in 1-year-old trunk/branches and leaves were contributed by gamma rays. However, the dose contribution from radionuclides in the lower trunk/branches and leaves was negligible. Conclusion: The fir tree model provides organ-specific DC values, which are satisfactory for the practical calculation of the absorbed dose rate of radiation from inside the tree. These calculations are based on the measurement of radionuclide concentrations in tree organs on the 1-year-old leader shoots of fir trees. With the addition of direct gamma ray measurements of the absorbed dose rate from the tree environment, the total absorbed dose rate was estimated in the terminal bud of fir trees in contaminated forests.

Acetaminophen의 감마선 분해에 대한 산화제 영향 (Effect of Oxidants on Decomposition of Acetaminophen by Gamma Irradiation)

  • 이면주;안영덕;이경훤;이오미;김태훈;정인하;유승호
    • 방사선산업학회지
    • /
    • 제5권4호
    • /
    • pp.359-364
    • /
    • 2011
  • This study was aimed to investigate the effect of oxidants on biodegradability and decomposition of acetaminophen (ACT) by gamma ray. Three kinds of chemical, potassium persulfate, hydrogen peroxide and ferrous sulfate were selected as an oxidant. The absorbed dose was ranged from 0.2 to 10 kGy and the concentration of oxidants was from 0.1 to 10 mM and the initial concentration of acetaminophen was $30mg\;l^{-1}$ in this study. The concentration of ACT was gradually decreased corresponding to the increase of the absorbed dose. However, mineralization of ACT was not occurred by the increased of the absorbed dose. When the 10 mM of oxidants applied to the ACT aqueous solution, the concentration of ACT was rapidly decreased according to absorbed dose and the mineralization was observed in potassium persulfate. Biodegradability of ACT with potassium persulfate was higher than that of ACT without potassium persulfate in lower absorbed dose and decreased according to higher absorbed dose.

Organ dose reconstruction for the radiation epidemiological study of Korean radiation workers: The first dose evaluation for the Korean Radiation Worker Study (KRWS)

  • Tae-Eun Kwon;Areum Jeong;Wi-Ho Ha;Dalnim Lee;Songwon Seo;Junik Cho;Euidam Kim;Yoonsun Chung;Sunhoo Park
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.725-733
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences has started a radiation epidemiological study, titled "Korean Radiation Worker Study," to evaluate the health effects of occupational exposure to radiation. As a part of this study, we investigated the methodologies and results of reconstructing organ-specific absorbed doses based on personal dose equivalent, Hp(10), reported from 1984 to 2019 for 20,605 Korean radiation workers. For the organ dose reconstruction, representative exposure scenarios (i.e., radiation energy and exposure geometry) were first determined according to occupational groups, and dose coefficients for converting Hp(10) to organ absorbed doses were then appropriately taken based on the exposure scenarios. Individual annual doses and individual cumulative doses were reconstructed for 27 organs, and the highest values were observed in the thyroid doses (on average 0.77 mGy/y and 10.47 mGy, respectively). Mean values of individual cumulative absorbed doses for the red bone marrow, colon, and lungs were 7.83, 8.78, and 8.43 mSv, respectively. Most of the organ doses were maximum for industrial radiographers, followed by nuclear power plant workers, medical workers, and other facility workers. The organ dose database established in this study will be utilized for organ-specific risk estimation in the Korean Radiation Worker Study.

Bias-corrected Hp(10)-to-Organ-Absorbed Dose Conversion Coefficients for the Epidemiological Study of Korean Radiation Workers

  • Jeong, Areum;Kwon, Tae-Eun;Lee, Wonho;Park, Sunhoo
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.158-166
    • /
    • 2022
  • Background: The effects of radiation on the health of radiation workers who are constantly susceptible to occupational exposure must be assessed based on an accurate and reliable reconstruction of organ-absorbed doses that can be calculated using personal dosimeter readings measured as Hp(10) and dose conversion coefficients. However, the data used in the dose reconstruction contain significant biases arising from the lack of reality and could result in an inaccurate measure of organ-absorbed doses. Therefore, this study quantified the biases involved in organ dose reconstruction and calculated the bias-corrected Hp(10)-to-organ-absorbed dose coefficients for the use in epidemiological studies of Korean radiation workers. Materials and Methods: Two major biases were considered: (a) the bias in Hp(10) arising from the difference between the dosimeter calibration geometry and the actual exposure geometry, and (b) the bias in air kerma-to-Hp(10) conversion coefficients resulting from geometric differences between the human body and slab phantom. The biases were quantified by implementing personal dosimeters on the slab and human phantoms coupled with a Monte Carlo method and considered to calculate the bias-corrected Hp(10)-to-organ-absorbed dose conversion coefficients. Results and Discussion: The bias in Hp(10) was significant for large incident angles and low energies (e.g., 0.32 for right lateral at 218 keV), whereas the bias in dose coefficients was significant for the posteroanterior (PA) geometry only (e.g., 0.79 at 218 keV). The bias-corrected Hp(10)-to-organ-absorbed dose conversion coefficients derived in this study were up to 3.09- fold greater than those from the International Commission on Radiological Protection publications without considering the biases. Conclusion: The obtained results will aid future studies in assessing the health effects of occupational exposure of Korean radiation workers. The bias-corrected dose coefficients of this study can be used to calculate organ doses for Korean radiation workers based on personal dose records.

핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰 (A study on Classification of Temporarily Access Group about Sanitation Workers in Nuclear Medicine Department)

  • 유재숙;장정찬;김호성
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.50-56
    • /
    • 2012
  • 일시 출입자로 분류된 핵의학과 출입 환경미화원은 주기적으로 타과와 업무순환을 하고, 또한 작업 시간과 환경 등의 변화가 많기 때문에 관리하기에 어려운 점이 있으며 따라서 이들의 분류를 명확히 할 필요가 있다. 이에 본 논문에서는 핵의학과에서 근무하는 환경미화원의 피폭 상황을 분석하여 일시 출입자로 분류된 조건의 타당성에 대하여 검토해 보고 작업 환경의 변화 및 근무 시간의 조절이 필요한가를 알아보았다. 우선 먼저 PET실과 혈액 검사실에서 근무하는 환경미화원과 감마 카메라실에서 근무하는 환경 미화원 2명을 대상으로 한 달간 근무 시간 중에 OSL을 각각 착용시켜 개인 피폭 선량을 측정하였다. 둘째로 survey meter를 이용하여 두 명의 환경미화원의 작업 환경, 근무 형태에 따라 시간대 별로 핵의학과 내 14개 구역을 선정, 총 10회 공간 선량률을 측정한 결과 이들의 피폭 선량은 연간 1mSv를 초과하지 않았으며, survey meter를 이용하여 조사한 결과 또한 연간 1 mSv를 초과하지 않을 것으로 추정되지만 그 수치가 1 mSv에 근접하였다. 따라서 일시 출입자로써의 분류를 좀 더 명확히 하기 위해서는 PET 안정실과 같은 피폭이 상대적으로 많은 구역에서의 노출 확률을 줄이기 위하여 이들에게 방사선 관리 구역내 교육을 실시하고, 또한 근무시간 및 근무 형태를 적절히 변경한다면 이들의 피폭 선량은 확연히 줄어들 것으로 사료된다.

  • PDF

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF

몬테칼로 기법을 이용한 CBCT의 인체 내 장기의 흡수선량 평가 (Assesment of Absorbed Dose of Organs in Human Body by Cone Beam Computed Tomography using Monte Carlo Method)

  • 김종보;임인철;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.215-221
    • /
    • 2018
  • Cone beam Computed Tomography(CBCT) is an increasing trend in clinical applications due to its ability to increase the accuracy of radiation therapy. However, this leaded to an increase in exposure dose. In this study, the simulation using Monte Carlo method is performed and the absorbed dose of CBCT is analyzed and standardized data is presented. First, after simulating the CBCT, the photon spectrum was analyzed to secure the reliability and the absorbed dose of the tissue in the human body was evaluated using the MIRD phantom. Compared with SRS-78, the photon spectrum of CBCT showed similar tendency, and the average absorbed dose of MIRD phantom was 8.12 ~ 25.88 mGy depending on the body site. This is about 1% of prescription dose, but dose management will be needed to minimize patient side effects and normal tissue damage.

사지의 방사선 치료에 사용하는 water bolus의 적용 시 치료부위의 위치 변화에 따른 방사선 선량분포의 민감도 연구 (A Study on Dose Sensitivity according to Position Variance in Extremities Radiation Therapy with Water Bolus)

  • 서정민
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.199-206
    • /
    • 2015
  • The purpose of this study was to investigate radiation dose sensitivity due to displacement of human extremities in the water bolus box on radiation therapy. Water bolus box and human thigh with femur bone were constructed in computerized radiation therapy planning system to verify the absorbed dose. Two 6MV X-ray beams were irradiated bilaterally into water bolus box and then radiation dose were calculated each situation at displacement of middle axis of thigh from the center in water bolus box to right and left direction. Absorbed dose of thigh and femur bone increased by the distance of displacement. The maximum dose of thigh even increased 20% over than prescribed dose. This is in contrast to conventional concept of dose distribution in water bolus box. Based on this result, displacement of body site in the water bolus box have to be averted during radiation therapy.

영상유도 방사선 치료(IGRT)에 따른 정상 조직의 추가 피폭에 대한 연구 (A Study on the Additional Absorbed Dose of Normal Tissues by Image Guided Radiation Therapy(IGRT))

  • 김가중;류준민;최준구;홍동희
    • 한국콘텐츠학회논문지
    • /
    • 제16권1호
    • /
    • pp.75-81
    • /
    • 2016
  • 최근 방사선 치료 분야에서는 다양한 영상유도 방사선 치료(IGRT) 장치들을 이용한 환자 셋업으로 고도의 정밀성이 보장된 치료가 가능해 졌다. 그러나 환자의 정상 조직에 받는 추가 선량 또한 더불어 증가되고 있다. 이에 본 연구에서는 영상유도 방사선 치료 장치 중 OBI, CBCT, ExacTrac를 이용한 환자 셋업에 주변 정상 조직에 받는 피폭선량을 측정하였다. 결과 팬텀 중심부의 선량이 CBCT의 경우 두부 12.57 mGy, 흉부 20.82 mGy, 복부 82.93 mGy, 골반부위 52.70 mGy로 측정되었으며 OBI는 0.76 ~ 8.58 mGy, ExacTrac의 경우 0.14 ~ 0.63 mGy로 CBCT의 피폭선량이 다른 장비에 비해 월등히 높게 나타나는 것을 알 수 있었다. 표면 선량의 경우에서도 CBCT가 다른 장비에 비해 높게 나타났으나 입사 피부표면 선량(Enterance skin dose)의 경우 OBI도 CBCT의 피폭선량과 거의 비슷한 흡수선량이 측정 되었다.