• Title/Summary/Keyword: Radiated

Search Result 1,039, Processing Time 0.027 seconds

Heat Sink of LED Lights Using Engineering Plastics (엔지니어링 플라스틱의 LED조명 방열판 적용)

  • Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.61-68
    • /
    • 2013
  • As an advance study for the development of a heat sink for special purpose high power illumination, an investigation was made to find feasibility for the application of copper plated EP to a heat sink of small LED light of less than 10W installed in commercial product. In this study, the plated heat sink with EP copper was fabricated for the conventional LED light. It was used actually for finding heat radiation property and effectiveness of the heat sink accompanied with measurement of luminous intensity. The heat is radiated by transfer and dissipation only through the copper plated surface due to extremely low heat conductivity of EP in case of EP heat sink; however the total area of the plate plays the function of heat transfer as well as heat radiation in case of the aluminum heat sink. It seems that the volume difference of heat radiating material is so big that the temperature $P_1$ is 9.0~12.3% higher in 3W and 42.7~54.0% higher in case of 6W volume difference of heat radiating material is so big that the temperature $P_1$ is 9.0~12.3% higher in 3W and 42.7~54.0% higher in case of 6W even though heat transfer rate of copper is approximately 1.9 times higher than that of aluminum. It was thought that this is useful to utilize for heat sink for low power LED light with the low heating rate. Also, the illumination could be greatly influenced by the surrounding temperature of the place where it is installed. Therefore, it seems that the illumination installation environment must be taken into consideration when selecting illumination. Further study was expected on order to aims at development of an exterior surface itself made into heat radiation plate by application of this technology in future.

Numerical Analysis on the Low Noise Designs of Savonius Wind Turbines by Inducing Phase Difference in Vortex Shedding (와류이탈 위상차를 이용한 사보니우스형 풍력터빈의 소음 저감 설계에 관한 수치적 연구)

  • Kim, Sanghyeon;Cheong, Cheolung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.3
    • /
    • pp.269-274
    • /
    • 2014
  • In this study, low noise designs for a Savonius wind turbine were numerically investigated. As was reported in our previous study, the harmonic components with a fundamental frequency higher than the BPF were identified as being dominant in the noise spectrum of a Savonius wind turbine, and these components were a result of vortex shedding. On a basis of this observation, an S-shaped blade tip is proposed as a means of reducing the noise generated by small vertical(Savonius) wind turbines. This blade induces phase differences in the shedding vortices from the blades, and thus reduces the noise from the wind turbine. The aerodynamic noise characteristics of the conventional and "S-shaped" Savonius turbines were investigated by using the Hybrid CAA method where the flow field around the turbine is computed using the CFD techniques and the radiated noise are predicted by applying acoustic analogy to the computed flow field data. The degree of noise reduction resulting from the proposed design and its reduction mechanism were confirmed by comparing the predicted noise spectrum of these turbines and the flow characteristics around them.

The Change of Blood Flow Velocity of Radial Artery after Linear Polarized Infrared Light Radiation near the Stellate Ganglion: Comparing with the Stellate Ganglion Block (성상신경절 부위의 직선편광 근적외선 조사 후 요골동맥에서의 혈류속도의 변화: 성상신경절 차단술과의 비교)

  • Han, Soung-Moon;Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.14 no.1
    • /
    • pp.37-40
    • /
    • 2001
  • Background: It had been reported by authors that linear polarized infrared light radiation (Superizer: SL) near the stellate ganglion had a similar effect on the change of skin temperature of hand compared with the stellate ganglion block (SGB). We hypothesized that this was due to dilatation of vessels and an increased blood flow. The aim of this study was to measure the velocity of blood flow in peripheral vessels after linear polarized infrared light radiation near the stellate ganglion and to compare the effect of SL with that of SGB using local anesthetics. Methods: Forty patients whose clinical criteria were matched for the symptoms of SGB were selected for study. We radiated the stellate ganglion by linear polarized infrared light radiation and measured the blood flow of radial artery using Ultrasound Doppler blood flow meter before and after 10, 20 and 30 minutes post-radiation. After 3 days, SGB was performed using 8 ml of 1% mepivacaine to the same patient, and the radial artery blood flow was measured in the same manner. Results: The blood flow velocity was increased by 40% and 27% at 10 min and 20 min after SL and by 42% and 41% at 10 min and 20 min after SGB. However, there was no statistically significant difference in blood flow velocity between SGL and SGB. Conclusions: We could conclude that linear polarized radiation is a clinically simple and useful noninvasive therapeutic tool in clinical area.

  • PDF

A Comparative Study on the Ultrastructures of the Egg Envelope in Fertilized Eggs of Fishes, Characidae, Three Species (카라신과 어류 3종의 수정란 난막 미세구조에 대한 비교 연구)

  • Kim, Dong-Heui;Reu, Dong-Suck;Deung, Young-Kun
    • Applied Microscopy
    • /
    • v.26 no.3
    • /
    • pp.277-291
    • /
    • 1996
  • The structures of the egg envelope in fertilized eggs of three species of characidae, head and tail light fish (Hemigrammus ocellifer), black tetra (Gymnocorymbus ternetzi), and buenos aires tetra (Hemigrammus caudovittatus) were studied using light and electron microscopes. The fertilized eggs in all species were colorless, transparent, spherical and non-floted type. The egg envelopes have a single micropyle resembling the pathway of sperm in the area of the animal pole. The micropyle was surrounded by protruded lines of the egg envelope in a radiated form. Egg envelopes of fertilized eggs in both head and tail light fish and buenos aires tetra consisted of three distinct layers; an outer layer, a middle layer and an inner layer. And that of blacktetra consisted of two layers; an outer layer and an inner layer. Also, an outer layers of both head and tail light fish and black tetra were adhesive types but, in that of buenous aires tetra was non-adhesive type. An outer surface of egg envelope in black tetra was arranged by pores regularly. In that of head and tail light fish and buenos aires tetra have a rough side. An inner layer of egg envelope in fertilized eggs consisted of lamellae alternating with interlamellae of lower electron density; an inner layer of fertilized eggs in head and tail light fish consisted of three layers, that of black tetra was four layers, and that of buenos aires tetra was five layers.

  • PDF

A Case of Epidural Blood Patch to Treat Headache Due to Spontaneous Intracranial Hypotension -A case report- (경막외 혈액봉합술을 이용한 자연성 두개내 저압성 두통 환자의 치험 1예 -증례 보고-)

  • Park, Soo-Seog;Jang, Yeon;Cho, Eun-Chung;Jee, Seung-Eun;Song, Ho-Kyung;Jung, Sung-Woo
    • The Korean Journal of Pain
    • /
    • v.11 no.2
    • /
    • pp.338-342
    • /
    • 1998
  • Postural headache due to spontaneous intracranial hypotension occurs without any diagnostic lumbar puncture, myelography, cranial or spinal injury, or spinal anesthesia. The clinical characteristics of the syndrome are disappearance of the headache or a notable decrease in its severity with recumbency, the finding of meningeal enhancement and subdural fluid collection on brain MRI, the pleocytosis and the increased CSF protein concentration. We report a case of a 40-year-old woman who exhibited the signs and symptoms of postural headache due to low CSF pressure. Her headache started suddenly at the occiput and radiated to frontal head. Magnetic resonance imaging (MRI) of her brain showed enhancement of the meninges and subdural fluid collection. Intrathecal radionuclide cisternography showed the delayed appearance of the isotope in the cranium and the minimal CSF leak at the left upper thoracic region. Her headache was relieved completely after a lumbar (L2-L3) epidural injection of 12 ml of autologous blood and remained asymptomatic.

  • PDF

A Study on the Telemetering Results of KSR-III Flight Test (KSR-3 비행시험 원격측정시스템 운용 결과)

  • Lee, Sang-Rae;Lee, Soo-Jin;Kim, Sung-Wan;Lee, Jae-Deuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.6
    • /
    • pp.96-101
    • /
    • 2003
  • Korea Sounding Rocket(KSR)-III onboard telemetry system has acquired various data from subsystems and sensors in the rocket, and radiated PCM/FM data using two S-band antennas during the flight. Simultaneously, it is necessary that the ground receiving systems track the rocket, and receive and decode telemetry data. Also post processed telemetry data are needed to be broadcasted on ethernet network in real time. Range safety display system displays flight trajectory using telemetry data in mission control center, and so flight manager makes a decision for flight termination from the trajectory This paper describes operating technique about telemetry reception, the development for the realtime data processing system, and the results for telemetering reception on fight test. We telemetered, processed, and broadcasted numerous telemetry data during the flight test successfully.

The Prediction of Field Strength for DTV Receiver in the VHF and UHF Bands (VHF 및 UHF 대역의 DTV 수신기 전계강도 예측)

  • Suh, Kyoung-Whoan;Jung, Hyuk;Lee, Joo-Hwan
    • Journal of Broadcast Engineering
    • /
    • v.15 no.6
    • /
    • pp.731-741
    • /
    • 2010
  • In this paper, we propose the methodology of prediction of field strength for a digital television (DTV) receiver by virtue of Recommendation ITU-R P.1546. The curves shown in this recommendation represent the point-to area field strength for 1.0 kW effective radiated power in the 30 MHz ~ 3000 MHz. Based upon the procedures described in this Recommendation, computation results are presented here from the derived formulation of field strength for DTV receiver. To show the validity of this method, some results are compared with the analysis by Okumura-Hata model and it was shown that the error of field strength is in the range of 6.9 ~ 11.5 %. The presented method provides not only the predicted values of field strength for DTV receiving area to check the quality of transmitted signal, but also an appropriate site selection for obtaining good propagation environment. In addition, it can be directly used for analyzing the protection ratio or separated distance for frequency sharing in the same band.

An Aortic Dissection in Pregnant Woman -a case report- (임산부에서 발생한 대동맥 박리 (Aortic Dissection) 1례)

  • Lee, Hyeong-Min;Hong, Eun-Pyo;Lee, Dong-Hyup;Lee, Jung-Cheul;Han, Sung-Sae;Sin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.253-259
    • /
    • 1993
  • We have experienced a case of aortic dissecting aneurysm in pregnant woman. She felt initially severe chest pain which was radiated to the neck on the 3days before delivery. Thereafter dyspnea and generalized edema were developed for 1 month after delivery. She was diagnosed as aortic dissection, Debakey typeII. During cardiopulmonary bypass, the selective cerebral perfusion was done through the right and left commom carotid arteries. Aortic replacement with Hemashield vascular graft and reimplantation of innominate artery, resuspension of aortic valve, repair of intimal tear were performed. The postoperative course was uneventful.

  • PDF

A Study on Design and Fabrication of Broad-Band EMC Filter for PC (PC용 광대역 EMC 필터의 설계 및 제작에 관한 연구)

  • 김동일;정상욱;김민정;전중성
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.11-15
    • /
    • 2004
  • This paper deals with EMC filter for a personal computer( PC). A PC contains many sources of noise inside and out, with many connected cables. High noise levels are also emitted from the PC became of high-speed signals. So radiated noise from the computer body may sometimes cause problems. Therefore, we design and fabricate an electromagnetic compatibility (EMC) filter for PC, which is composed of feed-through capacitors and ferrite beads with high permeability. Through extensive test, the proposed EMC filter is shown to have excellent differential-mode and common-mode noises filtering characteristics above 30 dB in the frequency band from 10 MHz to 1.5 GHz. The immunity characteristics are improved more than 10 to 30 dB over the frequency band from DC to 1.8 GHz

  • PDF

A Study on Broad-Band Design of Electromagnetic Wave Absorber in Ferrite Cylinder Insertion Type (페라이트 기둥 삽입형 전파흡수체의 광대역 설계에 관한 연구)

  • 이창우;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.23 no.1
    • /
    • pp.23-28
    • /
    • 1999
  • With a rapid progress in electronic industry we enjoy various conveniences of life. As many kinds of information equipments are supplied even to most of individuals as to be called an information society, we are exchanging much information with one another surprisingly. Consequently the occupation density of microwave frequency band is highly increased, and electromagnetic environment is getting more seriously bad. It often gives fatal blow to even human life and thus becomes serious social problems. Electromagnetic wave absorbers for anechoic chamber are needed to broaden the effective frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve it the alone requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the useful frequency bandwidth by the way of forming air layer(practically use urethane foam, etc.) on the ferrite tile. Therefore, an air layer is formed between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 400 MHz in bandwidth. Accordingly, in this paper, a broadened electromagnetic wave absorber are designed, which has the reflection characteristics less than -20 dB from 30 MHz to 6,000 MHz in the bandwidth. Then we achieved the goal by design the inserting square Ferrite Cylinders with the thickness less than 17.5 mm on existing grid type Ferrite absorber. The purpose of this research is on the development of very wide-band electromagnetic absorber for a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell, wall material for preventing TV ghost, etc.

  • PDF